• Title/Summary/Keyword: Field Reduction Factor

Search Result 228, Processing Time 0.022 seconds

Analysis of ELF Magnetic Field Reduction Factor of Electric Power Transmission Line (송전 선로 극저주파 자기장 저감지수(FRF) 특성 해석)

  • Myung, Sung-Ho;Cho, Yeon-Gyu;Lee, Dong-Il;Lim, Yun-Seok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.11 s.114
    • /
    • pp.1132-1142
    • /
    • 2006
  • This paper examined electric power transmission line models of reducing ELF(Extremely Low Frequency) magnetic field and analyzed the effects about models. In this research, FRF(Field Reduction Factor) of various models reducing magnetic field were analyzed compared to the horizontal 154 kV transmission line. As a result, the reduction ratio of magnetic field was almost proportioned to the compaction of phase-to-phase distance, and in case of diamond model and transposed model, magnetic field was able to be reduced nearly 50 %. It was analyzed that the magnetic field reduction ratio of triangle model was about 33 % and the magnetic field reduction ratio of split model was able to be reduced to 50 %. Especially, the magnetic field reduction ratio of multi split model could be reduced to 80 %.

Analysis on Magnetic Field Reduction Factor of Transmission Lines (송전선로 전자계 저감 Field Reduction Factor 분석)

  • Myung, S.H.;Cho, Y.G.;Jung, Y.H.;Lee, D.I.;Sin, G.Y.;Yoo, Y.P.
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.12-14
    • /
    • 2003
  • 본 연구에서는 우리나라의 송전선로에 주로 적용하고 있는 역상수직 2회선 배열을 기본 모델로 하여 다양한 저감 설계기술 적용시의 FRF(Field Reduction Factor)를 구하는데 중점을 두었다. 검토한 결과로는 신규선로 저감기술로서는 송전선로의 경우 지상고 증가, Compact Tower개발, Diamond Tower의 채용, 일부 구간의 Transposed 선로배치 등이 우리나라에서 적용 가능한 후보군으로 분석되었다.

  • PDF

Evaluation of Installation Damage Factor for Geogrid with Particle Size (입도에 따른 지오그리드의 시공손상계수 산정)

  • Lim, Seong-Yoon;Song, Chang-Seop
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.3
    • /
    • pp.113-120
    • /
    • 2010
  • Reduction factor for installation damage required to calculate design strength of geogrid used in MSEW(mechanically stabilized earth wall) design is usually obtained in the field test simulating real construction condition. However, damages occurred in geogrid during backfill work are influenced by many factors such as polymer types, unit weight per area, backfill construction method and gradation of backfill material and field test considering these factors demand lots of time and costs. In this study, factors affecting installation damage are analyzed and empirical method to evaluate reduction factor for installation damage using maximum particle size in backfill material is suggested.

Relationships between Methane Production and Sulfate Reduction in Reclaimed Rice Field Soils

  • Lee, Ju-Hwan;Cho, Kang-Hyun
    • Animal cells and systems
    • /
    • v.8 no.4
    • /
    • pp.281-288
    • /
    • 2004
  • The change in relationships between methane production and sulfate reduction was investigated in reclaimed rice field soils at different time points after reclamation of tidal flat in Korea. Sulfate concentrations of soils in the ca. 60-year-old and 26-year-old reclaimed rice fields were much lower than that in a natural tidal flat. During 60 d of anaerobic incubation, total methane production and sulfate consumption of the soil slurries were 7.0 ${\mu}$mol $CH_4$/g and 8.2 ${\mu}$mol $SO_4^{2-}$/g in the 60-year-old rice field, 5.6 ${\mu}$mol $CH_4$/g and 12.7 mmol $SO_4^{2-}$/g in the 26-year-old rice field, and ca. 0 mmol $CH_4$/g and 22.4 ${\mu}$mol $SO_4^{2-}$/g in a natural tidal flat. Relative percent electron flow through sulfate reduction in the 60-year-old rice field was much lower (50.8%) compared with the 26-year-old rice field (69.3%) and the tidal flat (99.9%). The addition of an inhibitor of methanogenesis (2-bromoethanesulfonate) had no effect on sulfate reduction in the soil slurries of the reclaimed rice fields. However, instant stimulation of methane production was achieved with addition of an inhibitor of sulfate reduction (molybdate) in the soil slurries from the 26-year-old reclaimed rice field. The specific inhibitor experiments suggest that the relationship of methanogenesis and sulfate reduction might become mutually exclusive or syntrophic depending on sulfate content in the soil after reclamation. Sulfate, thus sulfate reduction activity of sulfate-reducing bacteria, would be an important environmental factor that inhibits methane production and determines the major pathway of electron and carbon flow in anaerobic carbon mineralization of reclaimed rice field soils.

Evaluation of Installation Damage Factor for Geogrid using Maximum Particle Size of Backfill Material (뒤채움 최대입도를 이용한 지오그리드 보강재의 시공손상계수 산정 방법)

  • Kim, Kyung-Suk;Choi, Young-Chul;Kim, Tae-Soo;Lim, Seoung-Yoon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.6 no.4
    • /
    • pp.29-37
    • /
    • 2007
  • Reduction Factor for Installation Damage required for calculation of design strength of geogrid used in MSEW(mechanically stabilized earth wall) design is usually obtained in the field test simulating real construction condition. However, damages occurred in geogrid during backfill work are influenced by many factors such as polymer types, unit weight per area, backfill construction method and gradation of backfill material and field test considering these factors demands lots of time and costs. In this study, factors affecting installation damage are analyzed and empirical method for evaluating reduction factor for installation damage using maximum particle size in backfill material is suggested.

  • PDF

Reduction of Hexavalent Chromium Collected on PVC Filters in Field Electroplating Process (현장 도금 공정에서 PVC 여과지에 채취된 6가 크롬의 환원)

  • Shin Yong Chul;Paik Nam Won;Yi Gwang Yong;Lee Byung Kyu;Lee Ji Tae
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.1
    • /
    • pp.41-49
    • /
    • 2002
  • Recently, pilot studies showed an evidence of reduction of airborne hexavalent chromium, Cr(VI), on PVC filter during air sampling and storage. However, the information on this in the field was limited. Thus, we studied the reduction behaviors of airborne Cr(VI) on PVC filters during sampling and storage at three field electroplating operations. Regression between sampling time and the reduction (ratio of Cr(VI) to total Cr concentrations) was not statistically significant (p>0.05). However, the reductions in samples collected for 240 ~ 340 minutes were significantly higher than those for 30 - 60 minutes. On the other hand, another experiment showed a good correlation (r=0.96) between sampling time and the reduction without an exceptional value. Storage temperature was not a factor affecting the reduction of Cr(VI) collected on PVC filter. The loss of Cr(VI) samples stored in alkali solution (2% NaOH/3% Na$_2$CO$_3$) was significantly lower than that stored in vial according to NIOSH method (p<0.05). Thus, dipping Cr(VI) samples into alkali solution was a storage method to minimize tile reduction.

Analysis of ELF Magnetic Field Reduction Ratio on Passive Loop Using Scale Down Model of Transmission Line (축소 모델을 이용한 수동 루프 송전선 자기장 저감율 분석)

  • Cho, Yeun-Gyu;Myung, Sung-Ho;Lee, Jae-Bok;Chang, Sug-Hun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.12 s.115
    • /
    • pp.1231-1239
    • /
    • 2006
  • In this research magnetic field reduction effect of each passive loop was analyzed by using the scale down models of transmission lines. This paper examined magnetic field reduction effect of the passive loop that will be applied to actual facility through the experiment, which is about double vertical transmission line and horizontal transmission line. Consequently, by confirming the fact that magnetic field reduction effect can be obtained to 50 % by passive loop without reactive compensation, we insured technology about application of passive loop. And the case of 3 turns of loop showed two times reduction effect than that of 1 turns of loop in reducing magnetic field. Vertical passive loop is more efficient than horizontal passive loop in the aspect of reducing magnetic field on double vertical transmission lines. What is more, vertical passive loop showed good effect of reducing magnetic field in a far distance as well as in a short distance.

Installation Damage Reduction Factor for Geosynthetics Reinforcements Based on Various Full-Scale Field Installation Tests (다양한 현장내시공성시험에 근거한 토목섬유 보강재의 시공성 감소계수 평가)

  • Cho, Sam-Deok;Lee, Kwang-Wu
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.4
    • /
    • pp.225-238
    • /
    • 2018
  • In this paper, to investigate the influence of installation damage, a variety of full-scale field installation tests with 15 geosynthetics reinforcements and fill materials of various grain size distribution have been performed. The full-scale field installation test was conducted with reference to the FHWA (2009) guidelines. The tensile strength tests were performed by sampling up to 20 specimens randomly from the excavated geosynthetics reinforcements after compaction of fill material, and the degree of decrease in tensile strength of reinforcements due to compaction was analyzed based on the experiment results. It was found that the degree of tensile strength reduction of geosynthetics reinforcements due to the compaction of fill material is greatly influenced by the type of reinforcement and the maximum diameter of fill material. In addition, it was found that the strength reduction ratio of PET geogrid (PVC coating) with relatively small stiffness was greatest, and that the larger the maximum grain size of the fill material, the greater the strength reduction ratio. And also, a more reasonable evaluation method for the installation damage reduction factor of geosynthetics reinforcements is proposed based on the results of full-scale field installation tests in present study and the existing test results.

Filamentation and α-factor of broad area laser diodes (대면적 레이저 다이오드의 필라멘테이션과 α-factor)

  • Han, Il-Ki;Her, Du-Chang;Lee, Jung-Il;Lee, Joo-In
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.4
    • /
    • pp.319-323
    • /
    • 2002
  • 1.55 ${\mu}m$multi-quantum well (MQW) broad area laser diodes with different linewidth enhancement factors ($\alpha{-factor}$) of 2 and 4 were fabricated. The far-fields of the laser diodes were measured. It was observed that the full width at half maximum (FWHM) of the far-fields and the filamentations were reduced in the laser diodes for which the value of the $\alpha{-factor}$ was small. As injection current increased, the FWHM of the far-field also increased regardless of the a-factor. This phenomenon was explained by reduction of filament spacing as injection current increased.

The Effect of Construction Safety Supervision System on Risk Control and Reduction (건설안전감리제도가 위험제어 및 절감에 미치는 영향)

  • Lim, Jin-Sang;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.20 no.3
    • /
    • pp.1-9
    • /
    • 2018
  • This study is intended to look into the effect of construction safety supervision system on risk control and reduction. To achieve this, a survey was carried out to 114 companies in construction, ordering, contract and management. The overall findings were as follows. The effect of construction safety supervision system on risk control and reduction showed that factors of supervision system, supervision cost and supervision method had a positive effect on risk control and reduction. And their perception of the introduction of safety supervision system in construction sites according to process showed that there was a difference between them according to the field of ordering, contract and supervision. There was the biggest difference between owner and contractor in double supervision system, but no difference between them in the perception of risk reduction. These results show that all ordering, contract and supervision are positively needed for the introduction of construction safety supervision. This means that there is a difference between owner and contractor in the perception of process according to system operation. All companies agree to system improvement by the settlement of safety supervision system for the prevention of safety accidents and safe construction, but the systematic complement of safety supervision is the burden of contractor. And there is a big difference between owner and contractor in the perception of responsibility and concern for cost burden.