• 제목/요약/키워드: Field Measured

검색결과 7,161건 처리시간 0.031초

YBCO CC 적층 및 BSCCO tape 적층선재에서 수직자화 손실 값을 이용한 임의 방향 자화손실 평가 (Magnetization Loss Characteristics at Arbitrary Directional Magnetic Field by Perpendicular Magnetization Loss in YBCO CC and BSCCO Stacked Conductors)

  • 이지광;임형우;박명진;차귀수
    • 전기학회논문지
    • /
    • 제56권2호
    • /
    • pp.282-288
    • /
    • 2007
  • Magnetization loss of high temperature superconductoring BSCCO tape and YBCO coated conductor(YBCOCC) is most important issue in the development of superconducting power devices. In this paper, the measured results of magnetization losses under various angles of external magnetic field in BSCCO tape stacked conductors and YBCO CC stacked conductors are presented and compared with each other. Also, we present the compared results of magnetization losses measured at arbitrary reaction magnetic fields and analyzed with perpendicular magnetic field components of those. The results show that magnetization losses of YBCO CC single and stacked conductors agree well with the analyzed value by it's perpendicular magnetic field component, but BSCCO single and stacked conductors are not.

Development of an environment field monitoring system to measure crop growth

  • Kim, Yeon-Soo;Kim, Du-Han;Chung, Sun-Ok;Choi, Chang-Hyun;Choi, Tae-Hyun;Kim, Yong-Joo
    • 농업과학연구
    • /
    • 제46권1호
    • /
    • pp.57-65
    • /
    • 2019
  • The purpose of this study was to develop an environment field monitoring system to measure crop growth. The environment field monitoring system consisted of sensors, a data acquisition system, and GPS. The sensors used in the environment field monitoring system consisted of an ambient sensor, a soil sensor, and an intensity sensor. The temperature and humidity of the atmosphere were measured with the ambient sensor. The temperature, humidity, and EC of the soil were measured with the soil sensor. The data acquisition system was developed using the Arduino controller. The field monitoring data were collected before a rainy day, on a rainy day, and after the rainy day. The measured data using the environment field monitoring system were compared with the Daejeon regional meteorological office data. The correlation between the data from the environment field monitoring system and the data from the Daejeon regional meteorological office was analyzed for performance evaluation. The correlation of the temperature and humidity of the atmosphere was analyzed because the Daejeon regional meteorological office only provided data for the temperature and humidity of the atmosphere. The correlation coefficients were 0.86 and 0.90, respectively. The result showed a good correlation between the data from the environment field monitoring system and the data from the Daejeon regional meteorological office. Therefore, the developed system could be applied to monitoring the field environment of agricultural crops.

근거리장에서 NFS를 사용한 차폐효율 평가방법에 관한 연구 (A Study on the Evaluation Method of Shielding Effectiveness using NFS in Near-Field Tests)

  • 박정열;송인채;김부균;김은하
    • 전자공학회논문지
    • /
    • 제53권8호
    • /
    • pp.76-82
    • /
    • 2016
  • 본 논문에서는 근거리장에서 NFS(near field scanning)를 사용한 차폐효율 평가 방법을 통해 CNT(carbon nanotube) 필름의 차폐 특성을 분석하였다. 차폐 특성 평가는 농도 5%와 1mm의 두께를 가지는 CNT 필름과 실제 IC package를 모사한 테스트쿠폰을 사용하여 CNT 필름과 테스트쿠폰과의 거리에 따른 전자파 차폐효율 및 측정 위치에 따른 차폐효율을 측정하였다. 그 결과 근거리장에서 측정된 차폐효율은 주파수에 따라 차폐효율이 달랐다. 테스트쿠폰의 중심에서 측정된 전기장 차폐효율은 fringing effect의 영향을 받는 패턴경계보다 전기장 차폐효율이 좋은 것으로 측정되었다. 이는 근거리장에서 측정된 차폐효율은 주파수뿐만 아니라 CNT 필름과 측정 프로브의 높이, 측정 위치와 같은 측정 환경에 영향을 받는 것을 보여준다. 결론적으로 근거리장에서 제안된 방법을 사용하여 측정한 차폐효율과 ASTM D 4935-10에 의해 측정된 차폐효율은 연관성을 찾기 어렵기 때문에 전장 시스템의 거리 영역에 따라 적절한 측정 방법을 고려하여 측정해야 한다.

Design and fabrication of race-track type field coil for the high temperature superconduction generator

  • Baik, S.K.;Jo, Y.S.;Ha, H.S.;Lee, E.Y.;Jeong, D.Y.;Kwon, Y.K.;Ryu, K.S.;Sohn, M.H.
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 2000년도 High Temperature Superconductivity Vol.X
    • /
    • pp.248-251
    • /
    • 2000
  • The fabrication and characteristics of HTS race-track type field coil for generators was carried out. Field coils are composed of 3 pancake coils wound by 37-filamental Bi-2223/Ag-alloy tapes. The winding machine is horizontal type. The critical currents (I$_c$) of the superconducting tapes were measured with variation of bending strain and external magnetic fields. I$_c$ of both whole field coils and 3 pancake coils were measured as a function of temperature. At 77K under the self-field, I$_c$ of whole field coils was 12A, while in the case of middle pancake coil, I$_c$ was 15A. The distribution of magnetic field B was obtained, using 3-D FEM. Our simulation showed that maximums of B${\bot}$A in x-y plane were locally distributed in both the upper and the lower coils. In addition, the fabrication processes and the characteristics of field coil are described.

  • PDF

Field distribution factors and dynamic load allowance for simply supported double-tee girder bridges

  • Kidd, Brian;Rimal, Sandip;Seo, Junwon;Tazarv, Mostafa;Wehbe, Nadim
    • Structural Engineering and Mechanics
    • /
    • 제82권1호
    • /
    • pp.69-79
    • /
    • 2022
  • This paper discusses the field testing of two single-span double-tee girder (DTG) bridges in South Dakota to determine live load distribution factors (LLDFs) and the dynamic load allowance (IM). One bridge had seven girders and another had eight girders. The longitudinal girder-to-girder joints of both bridges were deteriorated in a way that water could penetrate and the joint steel members were corroded. A truck traveled across each of the two bridges at five transverse paths. The paths were tested twice with a crawl speed load test and twice with a dynamic load. The LLDFs and IM were determined using strain data measured during the field tests. These results were compared with those determined according to the AASHTO Standard and the AASHTO LRFD specifications. Nearly all the measured LLDFs were below the AASHTO LRFD design LLDFs, with the exception of two instances: 1) An exterior DTG on the seven-girder bridge and 2) An interior DTG on the eight-girder bridge. The LLDFs specified in the AASHTO Standard were conservative compared with the measured LLDFs. It was also found that both AASHTO LRFD and AASHTO Standard specifications were conservative when estimating IM, compared to the field test results for both bridges.

비파괴 밀도시험을 통한 아스팔트 콘크리트의 공극률 추정 연구 (Estimation of Air Voids of Asphalt Concrete Using Non-destructive Density Testing)

  • 나일호;이성진;윤지현;김광우
    • 한국농공학회논문집
    • /
    • 제60권6호
    • /
    • pp.111-119
    • /
    • 2018
  • The air-void is known to be one of the influencing factors for estimating long-term performance of asphalt concrete. Most of all, confirming air void or density of pavement layer is important for quality control of field compaction level of asphalt concrete pavement. In this study, a non-nuclear type non-destructive density gage (NDDG) was used to estimate compacted air-voids of asphalt pavement as a non-destructive test method. Asphalt concrete slab specimens were prepared using 6 types of asphalt mixes in laboratory (lab) for lab NDDG test. Four different base structure materials were used to find out if there were any differences due to the type of base structure materials. The actual air-voids and NDDG air-voids were measured from 6 asphalt concrete slabs. Four sections of field asphalt pavements were tested using the NDDG, and actual air voids were also measured from field cores taken from the site where the NDDG air-void was measured. From lab and field experimental tests, it was found that the air-voids obtained by NDDG were not the same as the actual air-voids measured from the asphalt concrete specimen. However, it was possible to estimate air voids based on the relationship obtained from regression analysis between actual and NDDG air voids. The predicted air-voids based on the NDDG air-voids obtained from 50mm depth were found to be reliable levels with $R^2{\fallingdotseq}0.9$. Therefore, it was concluded that the air-voids obtained from NDDG could be used to estimate actual air-voids in the field asphalt pavement with a relatively high coefficient of determination.

CTL cell에서의 우세장 발생과 특성 (The generation and characteristics of the dominant field in CTL cell)

  • 박웅희
    • 한국정보통신학회논문지
    • /
    • 제17권5호
    • /
    • pp.1055-1063
    • /
    • 2013
  • 전자파 내성 및 전자파 장해 측정을 위한 표준 전자파 발생 장치 중 하나인 CTL cell에서 두 개의 입력 단자에 동일 신호와 역위상 신호 입력에 따른 다양한 전계와 자계 발생에 대해 살펴보았다. 기본 공진주파수 TE011이 2.20GHz인 CTL cell을 이용하여 우세 전계장과 우세 자계장 조건에서 입력 전력의 변화에 따른 전계 특성, 측정 위치에 따른 전계 특성, 주파수 변화에 따른 전계 특성을 측정하였고, 이를 이용하여 CTL cell의 측정 영역에서의 동작 특성과 공진주파수의 영향을 받지 않고 사용 가능한 주파수 대역을 살펴보았다.

아동의 인지양식과 대인 문제 해결력 - 5세, 7세, 및 9세 아동을 대상으로 - (Cognitive Style and Interpersonal Problem Solving Ability among 5-, 7-, and 9-year-olds)

  • 정윤주;이순형
    • 아동학회지
    • /
    • 제14권1호
    • /
    • pp.77-89
    • /
    • 1993
  • The purpose of this study was to investigate (1) children's field dependence by age and sex, (2) children's interpersonal problem solving ability by age, sex, and contextual factors, (3) children's interpersonal problem solving ability by field dependence. The subjects were 120 five-, seven-, and nine-year-olds. Children's field-dependence was measured with the Children's Embedded Figures Test (CEFT). Children's interpersonal problem solving ability was measured with the Preschool Interpersonal Problem Solving Test (PIPS Test). Statistical methods adopted for data analysis were frequencies, percentiles, means, standard deviation, t-test, oneway ANOVA. $Scheff{\acute{e}}$ test and Pearson's correlations. Major findings were that (1) The older children were more field-independent than the younger ones (2) The older children suggested more problem solving methods and higher-level problem solving strategies than the younger ones. (3) Children suggested higher-level problem solving strategies in contexts involving familiar as opposed to unfamiliar participants and contexts involving children as opposed to adults. (4) 9-year-olds' field-independence was positively associated with interpersonal problem solving ability.

  • PDF

고기압 $SF_{6}$가스에서 전극표면 상태가 절열파괴 강도에 미치는 영향 (Influence of electrode surface conditions on breakdown field strength in pressurized $SF_{6}$)

  • 이동인
    • 전기의세계
    • /
    • 제30권3호
    • /
    • pp.172-176
    • /
    • 1981
  • The reduction in the breakdown field strength due to electrode surface roughness was calculated by applying the streamer breakdown criterion and the surface roughness factor, and measurements of static breakdown voltage for a gap with an artificial protrusion were made under the uniform field at pressures up to 4 bar in pressurized $SF_{6}$. The effect of polarity of highly stressed electrode on the breakdown field strength was also investigated. The measurements have shown that the measured breakdown levels for a protrusion located on the cathode agree with those calculated and the values measured with an identical anode protrusion are substantially higher and more scattered. This may be explained if it assumed that a high rate of production of initiatory electrons is maintained at the tip of a cathode protrusion by field emission. In practical point of view, the breakdown levels in pressurized $SF_{6}$ can be bereliably estimated from the values calculated.

  • PDF

자계하의 DC 코로나 방전에 의한 NOx 제거 (NOx Removal Using DC Corona Discharge Under Magetic Field)

  • 김건호;김종달;이덕출;고희석;박재윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.462-464
    • /
    • 1995
  • In this paper, experiments were carried out to study the decrease of NOx in simulated flue gases (initial concentration of NO 1000, 750, 400 ppm, : $N_2$ balance gas). Characteristics of NOx reduction are measured and analysed in corona discharge of multi needles to plane electrode structure and magnetic field. The best characteristics of NO reduction is measured when electric and magnetic field were supplied to reactor, at same time. Consumption power applied electric and magnetic field were higher than that of discharge applied only electric field.

  • PDF