• Title/Summary/Keyword: Field Intensity

Search Result 1,928, Processing Time 0.036 seconds

Analysis of Cable Protection of Duct in Lightning and HIRF Environment of UAM Aircraft and a Proposal for Certification Guidance (UAM 항공기 낙뢰 및 HIRF 환경에서 덕트의 케이블 보호 성능 분석 및 인증기술에 관한 연구)

  • Kim, Dong-Hyeon;Jo, Jae-Hyeon;Kim, Yun-Gon;Lee, Hakjin;Myong, Rho-Shin
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.3
    • /
    • pp.23-34
    • /
    • 2022
  • Cities around the world are increasing their demand for Urban Air Mobility (UAM) aircraft due to traffic congestion with population concentration. Aircraft with various shapes depending on fixed-wing and propulsion systems, are being prepared for commercialization. Airworthiness certification is required as it is a manned transportation vehicle that flies in the city center and transports people on board. UAM aircraft are vulnerable to lightning and HIRF environments due to the increasing use of composite materials, the use of electric motors, and use of electronic equipment. Currently, the development of certification technology, guidelines, and requirements in lightning and HIRF environments for UAM aircraft is incomplete. In this study, the certification procedures for lightning and HIRF indirect impacts of rotorcraft shown in AC 20-136B and AC 20-158A issued by the Federal Aviation Administration (FAA), were verified and applied to the computerized simulation of UAM aircraft. The impact of lightning and HIRF on ducted fan UAM aircraft was analyzed through computerized simulation, and the basis for establishing practical guidelines for certification of UAM aircraft to be operated in the future is presented.

Reliability of Non-invasive Sonic Tomography for the Detection of Internal Defects in Old, Large Trees of Pinus densiflora Siebold & Zucc. and Ginkgo biloba L. (노거수 내부결함 탐지를 위한 비파괴 음파단층촬영의 신뢰성 분석(소나무·은행나무를 중심으로))

  • Son, Ji-Won;Lee, Gwang-Gyu;An, Yoo-Jin;Shin, Jin-Ho
    • Korean Journal of Environment and Ecology
    • /
    • v.36 no.5
    • /
    • pp.535-549
    • /
    • 2022
  • Damage to forests, such as broken or falling trees, has increased due to the increased intensity and frequency of abnormal climate events, such as strong winds and heavy rains. However, it is difficult to respond to them in advance based on prediction since structural defects such as cavities and bumps inside trees are difficult to identify with a visual inspection. Non-invasive sonic tomography (SoT) is a method of estimating internal defects while minimizing physical damage to trees. Although SoT is effective in diagnosing internal defects, its accuracy varies depending on the species. Therefore, it is necessary to analyze the reliability of its measurement results before applying it in the field. In this study, we measured internal defects in wood by cross-applying destructive resistance micro drilling on old Pinus densifloraSiebold & Zucc. and Ginkgo bilobaL., which are representative tree species in Korea, to verify the reliability of SoT and compared the evaluation results. The t-test for the mean values of the defect measurement between the two groups showed no statistically significant difference in pine trees and some difference in ginkgo trees. Linear regression analysis results showed a positive correlation with an increase in defects in SoT images when the defects in the drill resistance graph increased in both species.

Demystifying an Appropriate Use of a Performer's 'Energy' Where the Performer's Body Becomes 'Real'

  • Son, Bong-Hee
    • International Journal of Advanced Culture Technology
    • /
    • v.10 no.2
    • /
    • pp.148-153
    • /
    • 2022
  • This thesis investigates the meaning of a performer's energy taking into an account of the full bodily engagement as the flow of energy and/or psychophysical readiness focusing specifically on the significance of qualitative bodily transformation. In this contemporary era, the dominance of performer training and its approaches to acting/training has very frequently meant that how to play a character in a textual based approach by emphasizing on interpreting and impersonating the role as real as possible. In this sense, as a performer trainer, from my observation and research findings shows that it is common for the term energy is not to be motivated by what a performer's body needs within a specific moment in specific performance which they are working on. To address the problematic issues, this thesis begins by interrogating the practical meaning of transformation with addressing the principle and process of movement by means of the flow of energy on stage. For a performer, inhabiting/integrating his/her body and mind as oneness and/or unity means s/he sincerely encounter, confront, and therefore listen to his/her body in here and now. Because since the performer's physical appearance completely defined his/her psychological state, no one can play either the past or the future in the moment. In this manner, an appropriate use of energy synonymous with the flow of energy correspondence with the given time and space in which the performer's body informs and initiates movement as necessary action. To be precise, the performer's bodily movement either visible or invisible in a sense of training and rehearsal is perceived as attaining or achieving psychophysical involvement as the full body engagement which enable to make the event happen in the right moment. Here, this thesis argues that the significance of a performer's inner intensity reminds us of the necessity of qualitative transformation on which the performer could discover his/her own mode of awareness as well as a way his/her body function in the given circumstance. From this point of view, this research finding would advocates that the performer's body maintains in the field of energy flow where his/her conscious effort and/or mindfulness disappear. The performer's movement is a manifestation of the whole bodily engagement by means of being as real in that moment rather than representing reality.

Helmholtz Coil and Performance of Magnetic Compass (인공자장발생장치와 자기 컴퍼스의 성능)

  • Ahn, Young-wha;Jeong, Kong-heun;Ahn, Jang-young;Sin, Hyeong-il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.19 no.2
    • /
    • pp.111-116
    • /
    • 1983
  • In order to furnish the fundamental data for the domestic production of magnetic compass and the prescription of standardization about it in Korea, authors made the helmholtz coil and investigated the characteristics of them. Subsequently, the damping curves of T190 and T165 compasses in the helmholtz coil were measured and analyzed the performance of those compass. The results obtained are as follows; 1. The relation between electric current (I sub I) to flow in the helmholtz coils, that the thickness of coil is 1mm, diameter 1m, winding number 117, and intensity of magnetic field is presented as follows. Vertical magnetic force: Z(Gauss)=0.34+1.506 I sub(i) Horizontal magnetic force: H(Gauss)=0.183+1.506 I sub(i) 2. Period of T190 compass is longer than T165 compass in all horizontal magnetic force. In the amplitude, the former is larger than the latter above 0.08 Gauss, but this phenomenon is opposed to that below 0.08 Gauss. 3. As the porizontal magnetic force is intensive, period of magnetic compass is short, amplitude is large, and damping degree and damping factor are small. The time elapsed to the principal points of damping curve is proportional to the -0.65 power of the horizontal magnetic force.

  • PDF

Finite element analysis for acoustic and temperature characteristics of a piezoelectric HIFU transducer at 10 MHz (10 MHz용 압전 HIFU 트랜스듀서의 음향 및 온도 특성에 대한 유한요소해석)

  • Jong-Ho Kim;Il-Gok Hong;Ho-Yong Shin;Hyo-Jun Ahn;Jong-In Im
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.33 no.3
    • /
    • pp.116-123
    • /
    • 2023
  • A high intensity focuses ultrasound (HIFU) is one of the emerging technologies in the biomedical field. The piezoelectric HIFU transducer is a device that utilizes the thermal energy generated by high ultrasound energy. Recently an operating frequency of the HIFU transducer is to expand above a 7 MHz. In this study, the acoustic pressures and temperature distributions in the tissue that generated by the HIFU transducer at 10 MHz were calculated with the finite element method. In addition, the pressure focusing characteristics of the device were analyzed. The geometrical variables are the piezomaterial thickness, lens shape, water height, and film thickness. The results shown that the acoustic pressure increased and saturated gradually when the height/radius (HL/RL) ratio of the lens increased. Moreover, the focal area was gradually decreases with HL/RL ratio of the lens. In case of the optimized HIFU transducer, the maximum pressure and temperature were analyzed about 19 MPa and 65℃ respectively. And the -3 dB focused distances in the axial and lateral direction are around 2.3 mm and 0.23 mm respectively.

Estimation of 3-D Hydraulic Conductivity Tensor for a Cretaceous Granitic Rock Mass: A Case Study of the Gyeongsang Basin, Korea (경상분지 백악기 화강암 암반에 대한 삼차원 수리전도텐서 추정사례)

  • Um, Jeong-Gi;Lee, Dahye
    • The Journal of Engineering Geology
    • /
    • v.32 no.1
    • /
    • pp.41-57
    • /
    • 2022
  • A workflow is presented to estimate the size of a representative elementary volume and 3-D hydraulic conductivity tensor based on fluid flow analysis for a discrete fracture network (DFN). A case study is considered for a Cretaceous granitic rock mass at Gijang in Busan, Korea. The intensity and size of joints were calibrated using the first invariant of the fracture tensor for the 2-D DFN of the study area. Effective hydraulic apertures were obtained by analyzing the results of field packer tests. The representative elementary volume of the 2-D DFN was determined to be 20 m square by investigating the variations in the directional hydraulic conductivity for blocks of different sizes. The directional hydraulic conductivities calculated from the 2-D DFN exhibited strong anisotropy related to the hydraulic behavior of the study area. The 3-D hydraulic conductivity tensor for the fractured rock mass of the study area was estimated from the directional block conductivities of the 2-D DFN blocks generated for various directions in 3-D. The orientations of the principal components of the 3-D hydraulic conductivity tensor were found to be identical to those of delineated joint sets in the study area.

Development and Verification of Muscle Strength Effectiveness Based on Fitsig® (EMG Prototype)

  • Changjin Ji;Yong-hyun Byun;Sangho Kim
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.5
    • /
    • pp.111-121
    • /
    • 2024
  • With strength training comes the risk of injury and the benefits of exercise. Lack of knowledge and experience or repetitions at excessive intensity can lead to injury. Adequate feedback on an exercise's progress can increase the exercise's effectiveness and reduce injuries by providing scientific data and psychological motivation. This study aimed to validate EMG equipment and examine the effects of 8 weeks of biofeedback training with wireless electromyography. A correlation analysis between the Noraxon device and Fitsig®(EMG Prototype), a well-known instrument in the field of research, showed a moderate correlation. Statistically significant differences in humeral circumference, humeral muscle mass, and biceps and triceps strength were found between the left and right sides of the body over time, with no differences in the type of exercise. Feedback training with real-time EMG was found to be favorable for hypertrophic growth and strength improvement. Future studies should be conducted to investigate its application in sports activities further.

Throughfall, Stemflow and Interception Loss at Pinus taeda and Pinus densiflora stands (테다소나무림과 소나무림에서의 수관통과우량(樹冠通過雨量), 수간유하우량(樹幹流下雨量) 및 차단손실우량(遮斷損失雨量))

  • Min, Hong-Jin;Woo, Bo-Myeong
    • Journal of Korean Society of Forest Science
    • /
    • v.84 no.4
    • /
    • pp.502-516
    • /
    • 1995
  • The objective of this study was to estimate throughfall, stemflow, interception loss and net rainfall in relation to rainfall interception, and to understand the factors affecting interception process at Pinus taeda stand and Pinus densiflora stand in the Research Forests of Seoul National University, located in Choosan, Kwangyang, Chollanamdo. 1. The gross rainfall during the period of field observation was 3,107.6mm(average 1,035.9mm/year). Most of the daily rainfall intensity was under 30mm, which was 90% in 1992, 81% in 1993 and 88% in 1994. 2. In this study the throughfall, stemflow, interception loss and net rainfall were expressed separately as a function of gross rainfall. The overall throughfall collected during the period of field observation was 2,432.5mm(78.3%) at Pinus taeda stand and 2,699.6mm at Pinus densiflora stand, out of total rainfall of 3107.6mm. The canopy storage capacity, which was determined by the prediction equation between gross rainfall and throughfall was 1.1mm at Pinus taeda stand and 1.3mm at Pinus densiflora stand. 3. The sums of stemflow from measurement of total rainfall at Pinus taeda stand and Pinus densiflora stand was 227.3mm(7.3%) and 62.7mm(2.0%), respectively. The minimum rainfall causing stemflow was estimated as 7.2mm at Pinus taeda stand and 1.9mm at Pinus densiflora stand. 4. Interception loss accounted for 447.8mm(14.4%) at Pinus taeda stand and 345.3mm(11.1%) at Pinus densiflorra stand. 5. Net rainfall was 2,659.8mm(85.6%) at Pinus taeda stand and 2,762.3mm(88.9%) at Pinus densiflora stand. 6. The rates of throughfall and stemflow increased with increasing the gross rainfall. However, the amounts of throughfall and the stemflow were constant above 30mm at Pinus taeda stand and 50mm at Pinus densiflora stand. The rates of interception loss decreased with increasing the gross rainfall. However, the amount of interception loss was constant above 50mm at Pinus taeda stand and Pinus densiflora stand.

  • PDF

Enhancement of Exchange Coupling Field and Thermal Stability by an Ultra-thin Mn Inserted layer on NiFe/[FeMn/Mn]80/NiFe Multilayers (NiFe/[FeMn/Mn]80/NiFe 다층박막에서 극-초박막 Mn 삽입에 의한 교환결합세기와 열적 안정성 향상)

  • Kim, Bo-Kyung;Lee, Jin-Yong;Ham, Sang-Hee;Lee, Sang-Suk;Hwang, Do-Guwn
    • Journal of the Korean Magnetics Society
    • /
    • v.13 no.2
    • /
    • pp.53-58
    • /
    • 2003
  • Annealing effects of exchange bias fields ($H_{2ex}$(top), $H_{lex}$ (bottom)) on composite type NiFe/[FeMn/Mn]$_{80}$/NiFe multilayers have been studied. Three samples with ultra-thin Mn inserted layers on glass/Ta(50 $\AA$)/NiFe(150 $\AA$)/[F $e_{53}$M $n_{47}$(1.25 $\AA$)/Mn(0 $\AA$, 0.11 $\AA$, 0.3 $\AA$)]$_{80}$/NiFe(90 $\AA$)/Ta(50 $\AA$) were prepared by ion beam sputtering. The average x-ray diffraction peak ratios NiFe(111) of FeMn (111) fcc textures for the Mn inserted total thicknesses of 0 $\AA$, 9 $\AA$, and 24 $\AA$ were about 0.65, 0.90, and 1.5, respectively. For the sample without Mn inserted layer, the $H_{2ex}$ of 260 Oe up to 300 $^{\circ}C$ disappeared at 350 $^{\circ}C$. For two multilayer samples with ultra-thin Mn layers of 0.11 $\AA$ and 0.3 $\AA$, the $H_{2exs}$ of 310 Oe and 180 Oe up to 300 $^{\circ}C$ endured of 215 Oe and 180 Oe at 350 $^{\circ}C$, respectively. The $H_{ex}$ (bottom)s of three samples decreased from 100 Oe to 70 Oe up to 250 $^{\circ}C$, while these values increased beyond 300 $^{\circ}C$. This observation can be attributed to less diffusive path of Mn atoms in bottom NiFe than top NiFe layer. The top and bottom coercive fields slightly varied about 5 Oe∼10 Oe. From these results, we could obtain the enhancement of exchange coupling intensity and thermal stability by an ultra-thin Mn inserted layer on NiFe/[FeMn/Mn]$_{80}$/NiFe Multilayers.

A survey on the EMF Levels of Study and Electric Appliances in Korea (국내 전철 및 가전제품을 대상으로 한 전자장 수준 실태조사)

  • Jang, Seong Ki;Cho, Yong Sung;Lee, Seok Jo;Yoo, Seong Wha;Jung, Kyung Mi;Lim, Jun Ho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.1
    • /
    • pp.71-81
    • /
    • 2005
  • The purposes of this study was to collect, analyze, and describe the MF exposure levels from subways in Korea and to measure and evaluate the MF levels generated from electric appliances used at general homes. The target subway lines were Seoul Metropolitan Line 1 to Line 8, Bundang Line, Incheon Line, Daegu Line, Gwangju Line, and Busan Line 1 and Line 2. We measured at each station in those subway lines and, all the train types (pantograph-equipped, motor-equipped, and common), and platform types(facing and isolating) were investigated by the distance(80, 200, 400 cm) from the train on 19 targeted subway lines using 3 magnetic field measuring devices (EMDEXII, Enertech Co.) during the survey from January till October, 2004. On the other hand, the levels of the 60Hz magnetic fields generated from 14 items of home electric appliances such as electric blankets, hair dryers, electric razors, etc. were measured at 10 general homes using 5 EMDEXII meters with a sampling interval of 1.5 second by the distance(surface, 30, 50, 100, 300cm ) from the target electric appliances. The survey results in the whole subway lines examined in this study were as follows; Seoul Metropolitan Line 4 using AC(alternating current) power source showed the highest mean value of $2.85{\mu}T$, followed by Seoul Metropolitan Line 1 running between Seoul and Incheon using AC($2.78{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Uijongbu using AC($2.73{\mu}T$), Bundang Line using AC($1.79{\mu}T$), Seoul Metropolitan Line 1 connected from Yongsan using AC($1.67{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Suwon using AC($0.79{\mu}T$), and so on. In general, the intensity of the magnetic field in the subway systems in Korea was significantly higher when using AC($2.14{\pm}0.91{\mu}T$) than when using DC($0.29{\pm}0.44{\mu}T$) power source. Among the home electric appliances examined, microwave ovens showed the highest mean value of $7.69{\mu}T$, followed by hair dryers($6.47{\mu}T$), vacuum cleaners($5.27{\mu}T$), televisions ($2.26{\mu}T$), electric blankets($1.38{\mu}T$), personal computers ($0.81{\mu}T$), and so on. Two items of electric appliances showed the excess value of $0.2{\mu}T$ at the distance of 30cm in the MF exposure level; electric razors $1.58{\pm}2.13{\mu}T$ and vacuum cleaners $0.48{\pm}0.44{\mu}T$. As a whole, this study showed a tendency that the shift of the MF levels according to the increase of distance from the electric appliances was lower than those of the results surveyed in UK and USA. As a result, this study is expected to suggest meaningful data for the future study in exposure assessment of magnetic fields and for the establishment of guidelines for subways and electric appliances in Korea. More detailed and large scaled exposure assessment studies should be performed continuously to get the various and useful information on health risk assessment of MFs in Korea.