• Title/Summary/Keyword: Field Installation

Search Result 1,194, Processing Time 0.025 seconds

Calculation of Load on Jacket Leg during Float-over Installation of Dual Topsides using Single Vessel (단일 설치선을 사용한 2기 해양플랜트 Topside Float Over 설치 시 Jacket Leg의 하중 계산)

  • Bae, Dong-Yeol;Lee, Seung-Jae;Lee, Jaeyong
    • Journal of Ocean Engineering and Technology
    • /
    • v.29 no.2
    • /
    • pp.135-142
    • /
    • 2015
  • The float over method is the most preferred method for installing heavy topside onto a jacket platform. A very complex platform with multiple jacket structures on a specific field requires multiple installation procedures. This study validated the installation of two topsides using a single installation barge to reduce the operation and installation cost. The hydrodynamic properties of the installation barge during the installation of two topsides were calculated. The tension and fender forces during docking were investigated to show the validity of the proposed dual topside installation method. In conclusion, the operational safety of the proposed procedure was validated through the calculation of the motion of the installation vessel and loads on the jacket legs.

The field-test of Power Quality Meter and Power Management System in order to verify the performance (PQM 및 PQMS 성능검증을 위한 실증시험)

  • Choi, Sun-Kyu;Song, Il-Keun;Kwon, Tae-Ho;Han, Jae-Wook
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.235-239
    • /
    • 2005
  • This paper gives a field-test method and result of PQM(Power Quality Meter) and PQMS(Power Quality Management System). The field-test was carried out as our own method. So, the test method has several kinds of improvement in this paper because it is first time to try the field-test of the equipment. However, we expect that the test result of PQM & PQMS has been used as a reference data which makes a scheme of evaluating performance of the equipment that has been used or is developed.

  • PDF

EDUCATION OF ELECTROMAGNETIC PENETRATION THROUGH NARROW SLOTS IN CONDUCTING SCREEN BY PARALLEL PLATE LOADING (평행평판 장하에 의한 슬릿 침투 전자파의 저감 특성)

  • Park, Eun-Jung;Ju, Chang-Hyun;Kim, Ki-Chai
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.66-68
    • /
    • 2005
  • This paper presents the reduction characteristics of penetrated electromagnetic fields through a narrow slot aperture in a planar conducting screen of infinite extent. When a plane wave is excited to the narrow slot, the aperture electric field is controlled by the parallel plate connected on the slot. The magnitude of penetrated electromagnetic fields through a narrow slot is controlled by electric field distributions on the slot aperture. An integral equation for the aperture electric field on narrow slots is derived and solved by applying Galerkin's method of moments. The results show that the magnitude of the penetrated electromagnetic field can be effectively reduced by installing the parallel plate on the slot aperture.

  • PDF

Performance Improvement of Synchronous Generator using Exciter Control with Field Coils Parameter Estimation Technique (계자코일 파라메터추정 기법을 이용한 동기발전기의 성능개선)

  • Kang, Seong-Hyun;Park, Seong-Mi;Lee, Hwa-Chun;Park, Sung-Jun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.4
    • /
    • pp.31-40
    • /
    • 2013
  • This paper proposes a performance improvement of synchronous generator using exciter control with field coils parameter estimation technique. In general, the generator excitation system controller uses the PID controller. When the Field winding impedance changed, the PID gains must be changed. General method is difficult to apply varying capacity of the synchronous generator. The proposed control method determine automatically measure the internal impedance of the synchronous generator's exciter and configure the controller. This method can be applied regardless of the generator capacity. So it is possible to apply a variety of synchronous generator systems. The validity of the proposed algorithm is verified by simulations and experiments.

Vector Control of an Induction Motor for the Field Weakening Region Considering the Variation of Magnetizing Inductance (자화인덕턴스 변화를 고려한 약계자 영역에서의 유도전동기 벡터제어)

  • ;李宅基
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.171-171
    • /
    • 1999
  • In case of field weakening region torque is directly affected by flux. In this region the flux reference is decreased inversely proportional to the rotor speed. As the flux is decreased the magnetizing inductance is normally increased. The increased magnetizing inductance limited voltage for controlling current. In this paper, measuring q axis voltage in field weakening region magnetizing inductance in flux calculating can be readjusted. Computer simulation and experiment results demonstrate the efficacy of the proposed method. Proposed algorithm is expected to the application of the adjustable drive system in the spinning and weaving field.

The Effects of Electric Field Variation by The Third Electrode on Water Electrophysicochemical Characteristics (제3전극에 의한 전계변화가 수중 전기물리화학적 특성에 미치는 영향)

  • Kim, Jin-Gyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.136-141
    • /
    • 2010
  • In this paper, after the third electrode type oxidant generator which could format non-uniform electric field in water had been manufactured and installed, by direct electrolysis, the effects of the hydrogen potential and oxidation reduction potential characteristics attendant upon electric field change on a higher concentration oxidant generation characteristics were investigated. Consequently, as the third electrode was installed in the middle of two slit electrodes and the polarity of applied power was changed, it was observed that the third electrode system with the positive electrode can generate a higher concentration oxidant, hydrogen potential and oxidation reduction potential as compared with that of the negative electrode. It is because the positive electrode was bombarded mostly energetic electrons and the negative electrode was bombarded mainly by less energetic positive ions.

A field trial of helically wrapping fiber optic cable onto existing 154KV Phase conductor. (전력선을 이용한 광케이블 현장 실증 시험)

  • Shin, Keon-Hak;Lee, Won-Bin;Cho, Hong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.143-146
    • /
    • 1987
  • Fiber optics provide a solution to the problems at interference, capacity and reliability in communication. Approximately 20 kilometera of a six-fiber, multimode, longwave($1.3{\mu}m$), graded index silica glass fiber optic cable was helically wrapped around a phase conductor at a Korea Electric Power Corporation(KEPCO) 154KV transmission line. This paper presents an economic comparison of several fiber optic cable installation alternative and discusses the characteristics at the helically wrapped fiber cable, as well as the entire installation, including high voltage phase-to-ground (PTG) end termination, and splicing. The fiber link was installed for the field trial and practical use with overhead composite optical fiber cable which installation performed a few years earlier some other location and is intended to accommodate not only telephone but also supervisory Control and Data Acquisition(SCADA), protective relaying, and telemetry functions.

  • PDF

The Performance Evaluation of Photovoltaic-integrated Lightshelf Systems (PV 일체형 태양광발전 광선반시스템의 성능평가)

  • Park, Hoon;Chung, Yu-Gun;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.12 no.6
    • /
    • pp.129-134
    • /
    • 2012
  • The lightshelf system, a daylighting device, has been applied to improve the visual environment by optimal light distributions and intense illumination levels of a interior. Also, The photovoltaic is one of the most important sustainable technologies appliable to architectures. This study aims to evaluate the performance of photovoltaic integrated lightshelf system. For the study, the 1/5 scaled office models were made and the field tests were experimented under clear sky conditions. The power ratio has been analyzed to evaluate the performance of photovoltaic integrated lightshelf system. As results, the power performance was high on photovoltaic lightshelf installation angle $0^{\circ}$. And the performance was reduced on 23(%) by installation angle $15^{\circ}$ and 63(%) by installation angle $30^{\circ}$.

A Research on the Actual Operating Condition of Guardlamps in Korea (국내 보안등 운용실태 조사)

  • Jung, Jong-Wook;Jung, Jin-Soo;Kim, Sun-Gu
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.212-215
    • /
    • 2008
  • In this paper, the recent technologies of a guardlamp are surveyed and the research on the actual condition of the management and maintenance is carried out. In addition, this paper intends to arouse people's attention to the electrical disasters caused by neglecting the installation, operation, management and maintenance of the guardlamp. In the process of the research, a field survey, a meeting of interested persons and manufacturers were performed and their opinions were reflected.

  • PDF