디지털시대의 대형사고의 전기적 영향 고찰 (Electric power system effect investigation of large size digital signal accident thought in digital age)

  • 강태근
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.575-580
    • /
    • 2004
  • The latest equipment automatic Intelligence of digital base done large size equipment appear in succession. That run by voltage electric current(mA, mV, ${\mu}A,\;{\mu}V$) that outline is microscopic of action of accuracy large size equipment of this digital base is bulk. Have received influence that is great in river electric field by installment that use computer. Most of domestic working voltage from service entrance extra-high voltage and working voltage of commercial frequency 60Hz working voltage 220V that use our country outside 1 country in interior of 22.900V for semiconductor use computer use digital installment of appliance as well as various smalls of digital base, middle, large size that safety is these fine voltage electric current that is not enough direct admonition hundred vast damage give can. Also, already act in surge circle and impulse transient phenomena such as several thousands, myriads, strong bit error more than billions time to digital fine electronic circuit by mistake use of using electric facility system of system electric power.

  • PDF

송전용 애자의 인공오손시험 기법과 누설전류 특성 (Artificial contaminated test method and leakage current characteristics of EHV insulators)

  • 최인혁;정윤환;최장현;이동일
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.386-391
    • /
    • 2004
  • To find out the reason of accident by being stained of insulators, this paper researched and analyzed the result of electrical characteristic test and field test of EHV insulator through artificial contaminated method. The best way to evaluate contaminated level of insulator surface is getting a contamination data by regional groups continually. But it is needed a lot of time and manpower. To overcome those difficulties, this research introduced ESDD(equivalent salt deposit density) measurement method which is adapted to the international codes of IEC and compared the relation between experimental test results which contaminated insulators by going through stain procedure and electrical measurement results.

  • PDF

빌딩시스템용 CAN 필드버스 모듈개발 및 적용에 관한 연구 (Application Technology and Development of CAN Fieldbus Modules for Building Automation System)

  • 이훈재;윤충섭;홍원표;이정훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.397-403
    • /
    • 2004
  • The controller area network(CAN) was originally developed to support cheap and rather simple automative applications, However, because of the its performance and low cost, it is also being considered in automated manufacturing and process control environments to interconnect intelligent devices, such as modem sensors and actuators. This paper presents a new application technology of the developed CAN control modules for the automated doors in building automation system. Key pad and RF methods are used to open and close the automated door by the slave CAN module with CAN protocol. BAS application technology of CAN field bus modules is also presented firstly in our nation.

  • PDF

오염물질에 따른 변압기부싱 모델의 기중 코로나 방전 특성 (Corona Discharge Characteristics of Transformer Bushing Model with Contaminnations in Air)

  • 방만식;김우진;김영석;김상현
    • 조명전기설비학회논문지
    • /
    • 제26권5호
    • /
    • pp.91-96
    • /
    • 2012
  • The surface of bushing is contaminated with rain, dust, salt and others. A bushing with contaminations in air is serious problem in insulation. Therefore, it is important to understand the inspection and diagnoses of the safety. The ultra-violet rays(UV) camera has attracted interest from the view point of easy judgement. In this paper, we will report on the corona discharge characteristics of surface flashover model with contaminations in air. Also, UV images of discharge and corona pulse count in air are analyzed using prototype UV camera of Korea and a UV sensor with an optic lens. These results are studied at both AC and DC voltage under a non-uniform field.

Design of Multi-protocol IED for Networked Control System of Multi-Induction Motor in Industrial Fields

  • Hong, Won-Pyo
    • 조명전기설비학회논문지
    • /
    • 제26권10호
    • /
    • pp.60-71
    • /
    • 2012
  • This paper proposes a new design and implementation of multi-protocol IED for networked control system of multi-induction motor in industrial fields. The experimental multi-induction motor based multi-protocol IED of Modbus/LonTalks/TCP/IP module is designed and fabricated. This article addresses issues in architecture of LonWorks/Ethernet sever, embedded processors architecture for converting Modbus protocol to LonTalks protocol, integrating preconfigured software, and Internet technologies. It is also verified that the multi-induction motor control and monitoring system using LonWorks/Ethernet server have available, interoperable, reliable performance characteristics from the experimental results, especially, the seamless integration of TCP/IP networks with control networks allows access to any control point from anywhere. Thus, the results provide available technical data for remote distributed motor control system of industrial field or building microgrid with LonWorks BAS.

부하변동에 따른 유도전동기 전류와 전력 특성 (Characteristics for Current and Power of Induction Motor by Load Variation)

  • 김종겸
    • 조명전기설비학회논문지
    • /
    • 제25권8호
    • /
    • pp.82-87
    • /
    • 2011
  • Induction motor is most widely used as the driving power in the industrial site. Induction motor current is composed of two parts, magnetizing current and load current. Load current uses energy what is doing the work. Load current varies with load variance but magnetizing current is constant, regardless of load variation. Magnetizing current needs for establishing the rotating magnetic field of induction motor and lags behind the voltage. Generally capacitor is used for power-factor compensation of inductive load. Self-excitation occurs when the capacitive reactive current from the capacitor is greater than the magnetizing current of the induction motor. When this occurs, excessive voltages can result on the terminals of the motor. This excessive voltage can cause insulation degradation and ultimately result in motor insulation failure. In this paper, we analyzed that how the magnetizing current and condenser current is operating at the allowable limit by the load variation. Condenser current is below allowable limit of magnetizing current but magnetizing current is above allowable limit at the lower load operation condition.

22.9[kV] 다중접지 배전계통에서 고장전류의 접지저항 영향 분석 (The Effect by Grounding Resistance of the ground Fault in the 22.9[kV] Multi-ground Distribution System)

  • 정금영;최선규;심건보;김경철
    • 조명전기설비학회논문지
    • /
    • 제24권10호
    • /
    • pp.85-89
    • /
    • 2010
  • During a ground fault the maximum fault current and neutral to ground voltage will appear at the pole nearest to the fault. Distribution lines are consisted of three phase conductors, an overhead ground wire and a multi-grounded neutral line. In this paper phase to neutral faults were staged at the specified concrete pole along the distribution line and measured the ground fault current distribution in the ground fault current, three poles nearest to the fault point, overhead ground wire and neutral line. A effect by grounding resistance of poles of ground fault current in the 22.9[kV] multi-ground distribution system. by field tests.

현장 시험에 의한 편력계통 안정화장치의 적정 파라메타 설정에 관한 연구 (A Study on the Optimal Parameter Selection of a Power System Stabilizer by Field Tests)

  • 김경철;임익헌
    • 조명전기설비학회논문지
    • /
    • 제15권3호
    • /
    • pp.83-90
    • /
    • 2001
  • 본 논문은 전력계통에 저주파수 동요현상을 제거하기 위한 목적으로 쓰이고 있는 전력계통 안정화 장치의 적정 파라메타 선정에 관한 알고리즘을 다루었다. 실측에 의한 발전기 시스템의 모델로부터 시스템 제 정수를 구하고, 극좌표 이동법으로 적절한 전력계통 안정화 장치의 파라메타를 Matlab으로 작성하여 구했다. 이 기법으로 선정된 전력계통 안정화 장치의 파라메타로 1기 무한대 계통에 적용한 시뮬레이션 결과는 만족한 만큼의 댐핑 효과를 보았다.

  • PDF

고효율 반사갓을 이용한 등기구 저감효과 (Effect of Lighting Saving Using High Efficiency Reflector)

  • 조현경;김재철;정승복;임상국
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.148-153
    • /
    • 2006
  • This paper analyzes the effect of the energy saving and evaluates the economics using High Efficiency lighting. About 18 percent (17,000GWh) of total power demands in Korea m consumed i]l the lighting field. There isa lot of energy potential that can be saved because the power demand isolwer relatively than the others parts. The existing lighting that its length and electric energy are 32[mm] and 40[w] can alternate with high efficiency lighting which its length and electric energy are 26[mm] and 32[w]. Two Lightings is measuring the illumination and the electric energy and then are analyzed into the effect of the lighting saving by measurement.

  • PDF

현장실증시험에 의한 대지저항률별 접지저항 보정계수의 결정 (The Determination of Corrective Coefficient for Ground Resistance about Variation of Soil Resistivity by Field Test)

  • 심건보;김경철;이형수;박재덕;박상만
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.288-292
    • /
    • 2006
  • Usually, equations that calculate ground resistance of earth electrode was already informed well by form of earth electrode. But, when apply on the spot because general expressions are very insufficient at point that calculate exact ground resistance value by variation of earth electrode, and constant value that corrective coefficient for ground resistance calculation is fixed regardless of change of the earth resistivity specially is presented, it is actuality that difficulty is. Therefore, in this study, about these problem, proposed corrective coefficient for calculation of ground resistance according to change of the earth resistivity.

  • PDF