A Numerical Study on Evaporation of Sludge Particles in a Sludge Dryer (열건조기내에서 슬러지 입자의 증발현상에 관한 수치해석 연구)

  • Ku, Bon-Ki;Kim, Sang-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.8
    • /
    • pp.1064-1072
    • /
    • 1998
  • The evaporation of sludge particles in a sludge dryer has been numerically investigated with commercial CFX4.1 code. Gas flow field, gas temperature field, sludge particle trajectories, and the moisture content variation of sludge particles are calculated fort various influencing factors, i. e., gas swirl velocity, initial particle distribution, gas temperature. Evaporation of sludge particles increases with gas swirl velocity, several supplying positions, and gas temperature, respectively due to increased residence time, increased contacting surface area, and increased temperature difference between gas and particle.

Angular dependence of critical current of SmBCO coated conductor fabricated by co-evaporation method

  • Kim, Ho-Sup;Ha, Hong-Soo;Oh, Sang-Soo;Song, Kyu-Jeong;Ko, Rock-Kil;Ha, Dong-Woo;Kim, Tae-Hyung;Youm, Do-Jun;Lee, Nam-Jin;Moon, Seung-Hyun;Yoo, Sang-Im;Park, Chan
    • Progress in Superconductivity and Cryogenics
    • /
    • v.10 no.2
    • /
    • pp.16-19
    • /
    • 2008
  • Angular dependence of critical current density of SmBCO coated conductor fabricated by co-evaporation method was investigated. For comparison, three samples were fabricated by a co-evaporation method and one sample was fabricated by a pulsed laser deposition process. The deposition system, named EDDC (Evaporation using Drum in Dual Chambers), is a batch type co-evaporation system, which is composed of reaction chamber and evaporation chamber. The normalized critical current density ratio ($I_c/I_c$(H//ab-plane)) of EDDC-SmBCO samples was found to be higher than that of PLD-YBCO sample in the whole range of angle. While the EDDC-SmBCO samples evidently had a peak at the angle of H//c-axis in the plot of the angular dependence of critical current, the normalized critical current of PLD-YBCO sample decreased monotonically without any peak as angle increased. The field dependence of critical current under the magnetic field parallel to the normal direction of those samples showed similar aspect in the range of $0\;G{\sim}5000\;G$.

Magnetically Driven Assemblies of γ-Fe3O4 Nanoparticles into Well-Ordered Permanent Structures

  • Byun, Myunghwan
    • Journal of Powder Materials
    • /
    • v.24 no.3
    • /
    • pp.229-234
    • /
    • 2017
  • We report on a simple and robust route to the spontaneous assembly of well-ordered magnetic nanoparticle superstructures by irreversible evaporation of a sessile single droplet of a mixture of a ferrofluid (FF) and a nonmagnetic fluid (NF). The resulting assembled superstructures are seen to form well-packed, vertically arranged columns with diameters of $5{\sim}0.7{\mu}m$, interparticle spacings of $9{\sim}2{\mu}m$, and heights of $1.3{\sim}3{\mu}m$ The assembled superstructures are strongly dependent on both the magnitude of magnetic field and the mixing ratio of the mixture. As the magnitude of the externally applied magnetic field and the mixing ratio of the mixture increase gradually, the size and interspacing of the magnetic nanoparticle aggregations decrease. Without an externally applied magnetic field, featureless patterns are observed for the ${\gamma}-Fe_3O_4$ nanoparticle aggregations. The proposed approach may lead to a versatile, cost-effective, fast, and scalable fabrication process based on the field-induced self-assembly of magnetic nanoparticles.

Analysis of the Statistical and Time-Series Characteristics for Pan Evaporation (증발계 증발량의 시계예 및 통계적 특성 분석)

  • 구자웅
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.19 no.3
    • /
    • pp.4472-4482
    • /
    • 1977
  • In order to estimate furture consumtive use, some statistical characteristics of 22-year pan evaporation data at four selected stations were calculated in this study. Districal distribution, trend analysis and time-series, statistical and periodic analysis for annual, monethly and ten-day values were performed in the statistical analysis. The stations are Seoul, Taeku, Jeonju and Mokpo for monthly data, and Suweon data are compared to the reported Penman values. The results are as followed: 1. Annual evaporation ranged to 990-1,375mm varying with the locations of the stations. The Districal distribution of evaporation in the Republic is shown in Fig. 1. 2. The trend analysis for annual evaporation resulted in detail in Table 2 and Fig. 2, through simple moving average methods. The results show relatively short-period data of about 10 years would be acceptable for field use. 3. The means and dispersions of monthly evaporation at four stations are detailed in Table 3. 4. The monthly evaporation approached to the trend of normal distribution Fig. 3 showed the examples of normal distribution for each typical monthly data. 5. The correlograms detailed in Fig. 4, shows the time-series characteristics of monthly evaporation, whose periodic term should be twelve months. 6. The periodic analysis for monthly evapolation results in Table 4. Fig. 5 shows the comparison of estimated values to actual and the trend approaches Shuster's periodic trend. 7. A periodic description of days after March 1 for irrigation periods was developed to predict ten-day evaporation in Fig. 6. The ten-day etraporation is different in the distribution form and occurence period of maximum values from the reported Penman's man's evapotranspiration.

  • PDF

Numerical Analysis on Removal Efficiency of Water Droplets in a Curved Vane Mist Eliminator with Consideration of Evaporation and Condensation at Surface of Droplets (액적 표면에서 증발 및 응축을 고려한 곡면 형상 액적 제거장치의 제거 효율에 대한 수치 해석)

  • Song, Dong Keun
    • Particle and aerosol research
    • /
    • v.12 no.4
    • /
    • pp.135-143
    • /
    • 2016
  • Removal of water contents in a gas is needed in industrial field of gas processing related on energy production/conversion, and environmental treatment. Inertial separators are economic devices for separating droplets from the gas stream. For accurate understanding of removal process in a curved vane mist eliminator, a numerical model including turbulent dispersion, evaporation and condensation of water vapor at surface of droplets is required. A two-stage curved vane mist eliminator has been modeled, and fluid flow of mixture of air and water vapor and droplet trajectories were solved simultaneously with taking into account two-way coupling. Removal efficiency of droplets with various inlet condition of relative humidities (RH, 40%, 90%, and 100%) were compared. As RH increased, the effect of evaporation decreased and inertial separation efficiencies of droplets obtained increased especially for droplets of diameter below 10 micrometers.

CENTRALLY PEAKED X-RAY SNRS : CLOUD EVAPORATION AND THERMAL CONDUCTION (X-선 중심 가광 초신성 잔해 : 성간운 증발과 열전도 모델)

  • CHOE SEUNG-URN;JUNG HYUN-CHUL;PARK BYEONG-GEON
    • Publications of The Korean Astronomical Society
    • /
    • v.14 no.2
    • /
    • pp.69-78
    • /
    • 1999
  • We present the results of one-dimensional numerical simulations of SNR evolution in the in­homogeneous medium considering the effects of the evaporation of the cloud and the thermal conduction. We have included the effects of changing evaporation rate as a function of cloud size and the ambient temperature so that the clouds could be evaporated completely before they reach the center of the SNR. The heat conduction markedly changes the density distribution in the remnant interior. To explain the observed morphologies of the centrally peaked X-ray SNRs(for example W44), the maximal thermal conduction is required. However, this is unlikely due to the magnetic field and the turbulent motion. The effects of the evaporation of the cloud and the thermal conduction described here may explain the class of remnants observed to have centrally peaked X-ray emmision.

  • PDF

Effect of Moisture Loss on Development of Distresses in Concrete Pavements

  • Jeong Jin-Hoon
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.4 s.88
    • /
    • pp.655-662
    • /
    • 2005
  • Evaporation of concrete influences the development of both initial transverse cracking and delamination in the concrete slab. It was suggested that spatting distress might develop in the slab where the initial transverse cracking occurred by theoretical equations and a field investigation. Thus, efforts to prevent the evaporation of concrete using proper curing methods are required to minimize the distresses of the slabs. Effective curing thickness (ECT) concept was used in this paper to evaluate various curing methods used to prevent the evaporation from concrete. Curing effectiveness quantified by the ECT of different types and amounts of curing compound under various curing conditions was investigated based on the results of laboratory tests. According to the test results, the wind speed is inferred to be a significant factor of the magnitude and continuance duration of the curing effectiveness.

A Study on the Method for Estimating Evapotranspiration from Paddy Fields (수도의 증발산량 추정방법에 관한 연구)

  • 허재석;정하우
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.25 no.2
    • /
    • pp.86-95
    • /
    • 1983
  • Evapotranspiration is a major factor determining the water consumption in the rice fields. Therefore, realistic evapotranspiration estimates are important to the agricultural water resources planning. In Korea, however, the Blaney-Criddle formula, which was developed under the meteorological condition of western arid United States and the upland cultivation, has been widely used to estimate evapotranspiration from paddy fields. Hence, it has considered that the Blaney-Criddle formula would not be the proper method for the Korean paddy condition. The purpose of this study is to select the most appropriate and realistic method for estimating evapotranspiraion from paddy field in Korea and to derive crop coefficients using the chosen method. The results are summerized as follows. 1. Total seasonal-average evapotranspiration by the field observation was 660mm for Tongil and 621. Ornm for the Japonica variety of rice. The amount of evapotranspiration for Tongil variety was 6% larger than that of the Japonica variety. 2. There was no significant differences in the amount of evapotranspiration among early, middle and late mature varieties, that is, early 638mm, middle 627mm and late 630mm for the whole growing season. 3. The rate of peak evapotranspiration appeared at the beginning of August and was in the range of 7.7-8. Omm/day according to the different mature varieties. 4. The correlation between pan evaporation data and the calculated evapotranspiration using related meteorological data from various methods suggested such as Radiation (FAO), Hargreaves, Christiansen, Hargreaves-Christiansen, Jensen-Haise, showed high statistic significance. Therefore, it seemed to use those formulars in estimating evapotranspiration inste4 of using pan evaporation data. 5. It was concluded from the analysis of field data that the evapotranspiration estimate for Blaney-Criddle method might not be appropriate in Korea. On the other hand, Penman equation showed more accurate estimation at the flourishing stage of rice than the pan evaporation method. 6. The crop coefficients for the Penman and pan-evaporation method were obtained by graphical representation.

  • PDF

Organic field-effect transistors with step-edge structure

  • Kudo, Kazuhiro
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.91-93
    • /
    • 2008
  • The organic field-effect transistors with step-edge structure were fabricated. Source and drain electrodes were obliquely deposited by vacuum evaporation. The step-edge of the gate electrode serve as a shadow mask, and the short channel is formed at the step-edge. The excellent device performances were obtained.

  • PDF

Evaluation of Passive Cooling Effect on Roof Pond through Field Observation (관측에 의한 옥상 수공간의 자연냉각효과 평가)

  • Jeong, Seong-Jin;Choi, Dong-Ho;Lee, Bu-Yong
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.85-89
    • /
    • 2008
  • This study carried out field observations of measuring thermal environment, especially evaluating amount of water evaporation at roof Pond by field observations during the summer. Thermal environment measuring was categorized as air temperature, water temperature of roof pond, surface temperature, globe temperature, short and long wave radiation, net radiation, and amount of water evaporation by water level measurement. Results from this study could be used as fundamental for reducing heat Island phenomena.

  • PDF