• Title/Summary/Keyword: Field

Search Result 75,298, Processing Time 0.079 seconds

Effect of near and far-field earthquakes on RC bridge with and without damper

  • Soureshjani, Omid Karimzade;Massumi, Ali
    • Earthquakes and Structures
    • /
    • v.17 no.6
    • /
    • pp.533-543
    • /
    • 2019
  • This paper presents a study on the behavior of an RC bridge under near-field and far-field ground motions. For this purpose, a dynamic nonlinear finite element time history analysis has been conducted. The near-field and far-field records are chosen pairwise from the same events which are fits to the seismic design of the bridge. In order to perform an accurate seismic evaluation, the model has been analyzed under two vertical and horizontal components of ground motions. Parameters of relative displacement, residual displacement, and maximum plastic strain have been considered and compared in terms of near-field and far-field ground motions. In the following, in order to decrease the undesirable effects of near-field ground motions, a viscous damper is suggested and its effects have been studied. In this case, the results show that the near-field ground motions increase maximum relative and residual displacement respectively up to three and twice times. Significant seismic improvements were achieved by using viscous dampers on the bridge model. Somehow under the considered near-field ground motion, parameters of residual and relative displacement decrease dramatically even less than the model without damper under the far-field record of the same ground motion.

A Study of Image Quality and Exposed Dose by Field Size Changing on CBCT (CBCT 촬영 시 조사야 조절에 따른 영상의 최적화 및 피폭선량에 관한 고찰)

  • Bang, Seung Jae;Kim, Young Yeon;Jeong, Il Seon;Kim, Jeong Soo;Kim, Young Gon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.175-180
    • /
    • 2013
  • Purpose: Modern radiation therapy technique such as IGRT has become a routine clinical practice on LINAC for decrease patient's set-up error. CBCT can be used to adjust patient set-up error and treat patient more accurately. The Purpose of this study is to evaluate field size of CBCT for improving Image quality and suggest reference date of CBCT field size. Materials and Methods: Image date were acquired using KV CBCT and Catphan phantom (Half fan and full fan mode were scanned from 2 ~16 cm, at intervals of 2 cm). Field size were categorized by Small field size (2 cm, 4 cm), Medium field size (8 cm, 10 cm), Large field size (more than 14 cm) and evaluate. To estimated the CTDi using CTDi phantom and Ion chamber. Results: CT number linearity of Small and Large field size are greater than Medium field size. Spatial resolution are not significantly different without Small field size. But half fan mode is more different than full fan mode. In full fan, except Medium field size, all field size exceed recommendation for HU uniformity. But half pan has stability for all field except Small field size. CTDi makes radical sign function graph in Medium field size. Conclusion: The worst result was given by Small field size for Image quality and practically. Medium field size can be useful to prevent patient from radiation exposure and give better Image quality. So this study recommends that Medium field size (8~10 cm) is more suitable for CBCT.

  • PDF

Field-in-Field Technique to Improve Dose Distribution in the Junction of the Field with Head & Neck Cancer (Field-in-Field Technique을 이용한 두경부암의 접합부위 선량개선에 관한 고찰)

  • Kim, Seon-Myeong;Lee, Yeong-Cheol;Jeong, Deok-Yang;Kim, Young-Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.17-23
    • /
    • 2009
  • Purpose: In treating head and neck cancer, it is very important to irradiate uniform dose on the junction of the bilateral irradiation field of the upper head and neck and the anterior irradiation field of the lower neck. In order to improve dose distribution on the junction, this study attempted to correct non uniform dose resulting from under dose and over dose using the field-in-field technique in treating the anterior irradiation field of the lower neck and to apply the technique to the treatment of head and neck cancer through comparison with conventional treatment. Materials and Methods: In order to examine dose difference between the entry point and the exit point where beam diffusion happens in bilateral irradiation on the upper head and neck, we used an anthropomorphic phantom. Computer Tomography was applied to the anthropomorphic phantom, the dose of interest points was compared in radiation treatment planning, and it was corrected by calculating the dose ratio at the junction of the lower neck. Dose distribution on the junction of the irradiated field was determined by placing low-sensitivity film on the junction of the lower neck and measuring dose distribution on the conventional bilateral irradiation of the upper head and neck and on the anterior irradiation of the lower neck. In addition, using the field-in-field technique, which takes into account beam diffusion resulting from the bilateral irradiation of the upper head and neck, we measured difference in dose distribution on the junction in the anterior irradiation of the lower neck. In order to examine the dose at interest points on the junction, we compared and analyzed the change of dose at the interest points on the anthropomorphic phantom using a thermoluminescence dosimeter. Results: In case of dose sum with the bilateral irradiation of the upper head and neck when the field-in-field technique is applied to the junction of the lower neck in radiation treatment planning, The dose of under dose areas increased by 4.7~8.65%. The dose of over dose areas also decreased by 2.75~10.45%. Moreover, in the measurement using low-sensitivity film, the dose of under dose areas increased by 11.3%, and that of over dose areas decreased by 5.3%. In the measurement of interest point dose using a thermoluminescence dosimeter, the application of the field-in-field technique corrected under dose by minimum 7.5% and maximum 17.6%. Thus, with the technique, we could improve non.uniform dose distribution. Conclusion: By applying the field-in-field technique, which takes into account beam divergence in radiation treatment planning, we could reduce cold spots and hot spots through the correction of dose on the junction and, in particular, we could correct under dose at the entry point resulting from beam divergence. This study suggests that the clinical application of the field-in-field technique may reduce the risk of lymph node metastasis caused by under dose on the cervical lymph node.

  • PDF

A Study on the Effects of Magnetic Field and BEP on Hyperlipidemia and Enzymatic Activities in Rats (자기장(磁氣場) 및 BEP 조사(照射)가 식이성(食餌性) 고지혈증(高脂血症)이 유발(誘發)된 흰쥐에 미치는 영향(影響)에 대(對)한 연구(硏究))

  • Koh, Kwang-chan;Lee, Cheol-wan
    • Journal of Haehwa Medicine
    • /
    • v.8 no.1
    • /
    • pp.559-592
    • /
    • 1999
  • It has been known that Ki(氣) energy is very effective on many adult diseases. Oriental Medicine has acknowledged Ki as an existing reality and investigated its effects on the body. However, the existence of Ki has not been fully explained. In order to find a conclusive evidence on the existence of Ki, this experiment was done to study the mutual relationship of Ki with a magnetic field and BEP (biological energy projector). The BEP apparatus was irradiated under the magnetic field on rats in the hyperlipidemic induced state. Following criterias were measured in this experiment: weight change, weight of the visceral organs, serum, hepatic lipid peroxide, bleeding time, tissue factor, and etc. The following results were obtained in this study: 1. The weight of rat significantly decreased in the magnetic field treated group and radically reduced in the group treated with both magnetic field and BEP. 2. The weight of liver, heart, and kidney increased in both the magnetic field treated group and magnetic field+BEP group compared to the normal group, but decreased in comparison to the control group. No changes were witnessed in the weight of spleen. 3. Serum and hepatic total cholesterol, total lipid, and lipid peroxide level significantly decreased in both magnetic field treated group and magnetic field+BEP treated group, while lipase activity has increased noticeably. 4. Serum HDL showed a significant increase in both magnetic field treated group and magnetic field+BEP treated group compared to the control group, while LDL and VLDL level decreased significantly. 5. A bleeding time significantly increased in both magnetic field treated group and magnetic field+BEP treated group compared to the control group. A tissue factor value of the lung decreased in the magnetic field treated group and magnetic field+BEP treated groups while increased in the control group. 6. Serum and hepatic lipid peroxide and glutathione level were significantly decreased in the magnetic field treated group and magnetic field+BEP treated group, while hepatic glutathione level was significantly increased compared to the control group. 7. A significant increase was found in the serum hydroxyl radical and SOD activity in the dietary hyperlipidemic rats, and significant decrease was found in the serum lipid peroxide content and superoxidase activity. 8. Hepatic cytosolic enzyme xanthine oxidase and aldehyde oxidase showed a significant decrease in the magnetic field treated group and magnetic field+BEP treated group. Through the above experimental results, one can suggest that the magnetic field with BEP can suppress hyperlipidemia and boost lipid metabolism and restructuring a lipid in liver, which increases the function of liver. To conclude, BEP is considered to show more potent effects under the exposure of magnetic field because magnetic field seems to increase the flow of Ki in the body.

  • PDF

Development of a Method for Improving the Electric Field Distribution in Patients Undergoing Tumor-Treating Fields Therapy

  • Sung, Jiwon;Seo, Jaehyeon;Jo, Yunhui;Yoon, Myonggeun;Hwang, Sang-Gu;Kim, Eun Ho
    • Journal of the Korean Physical Society
    • /
    • v.73 no.10
    • /
    • pp.1577-1583
    • /
    • 2018
  • Tumor-treating fields therapy involves placing pads onto the patient's skin to create a low- intensity (1 - 3 V/cm), intermediate frequency (100 - 300 kHz), alternating electric field to treat cancerous tumors. This new treatment modality has been approved by the Food and Drug Administration in the USA to treat patients with both newly diagnosed and recurrent glioblastoma. To deliver the prescribed electric field intensity to the tumor while minimizing exposure of organs at risk, we developed an optimization method for the electric field distribution in the body and compared the electric field distribution in the body before and after application of this optimization algorithm. To determine the electric field distribution in the body before optimization, we applied the same electric potential to all pairs of electric pads located on opposite sides of models. We subsequently adjusted the intensity of the electric field to each pair of pads to optimize the electric field distribution in the body, resulting in the prescribed electric field intensity to the tumor while minimizing electric fields at organs at risk. A comparison of the electric field distribution within the body before and after optimization showed that application of the optimization algorithm delivered a therapeutically effective electric field to the tumor while minimizing the average and the maximum field strength applied to organs at risk. Use of this optimization algorithm when planning tumor-treating fields therapy should maintain or increase the intensity of the electric field applied to the tumor while minimizing the intensity of the electric field applied to organs at risk. This would enhance the effectiveness of tumor-treating fields therapy while reducing dangerous side effects.

A comparative study of dose distribution for whole brain with field-in-field technique (전뇌(Whole Brain)치료 시 Field-in-Field Technique 적용에 관한 고찰)

  • Kim Bo Kyoum;Lee Je Hee;Jung Chi Hoon;Pack Heung Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.9-17
    • /
    • 2005
  • Purpose : Uniform dose distribution of the target volume is very important in the radiation treatment. We will evaluate the usefulness of Field-in-Field Technique use to get uniform dose distribution of the target volume and try to find Apply possibility out to a whole brain treatment patient of various thickness. Material and method : We compare the dose distribution when we applied Field-in-Field Technique and parallel opposed fields technique. establish the treatment plan to a phantom(acryl 16cm spheral phantom) and do the measurement, assessment use the TLD and Low sensitivity film. Also the assessment did Apply possibility of Field-in-Field Technique to 20 patient object of various thickness. Result : In the case to use the parallel opposed fields at the whole brain treatment $10-12\%$ high dose region appeared but reduce to $3-4\%$ lesses when we used the Field-in-Field technique. We could get similar numerical value the film and TLD measurement result also. The change of the dose distribution appeared to its ${\pm}1{\sim}2\%$ although it applied such Field-in-Field technique to various patient so that we were identical. Conclusion : We can get uniform dose distribution of in the treatment region if we apply the Field-in-Field technique at the whole brain treatment. Also alternate can play the role of the wedge filter and 3D compensator and We are thought by minimizing the obstacle to be happened due to the high dose region when radiation treatment.

  • PDF

The Study on CMA using field terminator (Field terminator를 이용한 CMA 제작에 관한 연구)

  • 이충만;성면창;권순남;정광호
    • Journal of the Korean Vacuum Society
    • /
    • v.5 no.4
    • /
    • pp.278-283
    • /
    • 1996
  • We constructed a single path cylindrical mirror analyser(CMA) using field terminator methods. With computer simulation, the best fit voltage ratio and position of the field terminaor was determined with maintain log-scale equipotential line near both end of the CMA. Then we construct field terminator with voltage divider of metal-oxide resisters which reduces the fringe field effect. The resolving power of the CMA was better than $\Delta$E/E=0.4%.

  • PDF

Collision Avoidance for UAV using Potential Field based on Relative Velocity of Obstacles (장애물의 상대속도를 반영한 포텐셜필드 기반 무인항공기 충돌회피)

  • Ahn, Seung-gyu;Lee, Dongjin
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.26 no.2
    • /
    • pp.47-53
    • /
    • 2018
  • In this paper, we investigate a collision avoidance algorithm for unmanned aerial vehicles using potential field based on the relative velocity of obstacles. The potential field consists of the attraction force and the repulsive force that are generated for the target and the obstacles. And the field can be classified into the attractive potential field generated by the target and the repulsive potential field generated by the obstacle, respectively. In this study, we construct an attractive potential field as a function of the distance between the UAV and the target position. On the other hand, a repulsive potential field is created by a function of distance and the relative velocity of the obstacle with respect to the UAV. The proposed potential field based collision avoidance algorithm is evaluate through simulations.

Properties of Field Emission Electrons for CVD-grown Carbon Nanotubes (CVD법으로 제조한 탄소 나노튜브의 전계 전자 방출 특성)

  • Lee, Rhim-Youl
    • Korean Journal of Materials Research
    • /
    • v.13 no.7
    • /
    • pp.424-428
    • /
    • 2003
  • The microstructure and field emission properties of carbon nanotubes(CNT) grown by Ni-catalytic chemical vapor deposition(CVD) were investigated. CVD-grown CNT had a high density of curved shape with randomly oriented. It was found that an increase in electric field caused an increase in field emission current and field emission sites of CNT. The maximum field emission current density was measured to be 3.6 ㎃/$\textrm{cm}^2$ at 2.5 V/$\mu\textrm{m}$, while the brightness of 56 cd/$\textrm{cm}^2$ was observed for the CNT-grown area of 0.8 $\textrm{cm}^2$ from a phosphor screen. Field emission current at constant electric field gradually decreased initially and then stabilized with time.

Analysis of mechanical characteristics of superconducting field coil for 17 MW class high temperature superconducting synchronous motor

  • Kim, J.H.;Park, S.I.;Im, S.H.;Kim, H.M.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.3
    • /
    • pp.13-19
    • /
    • 2013
  • Superconducting field coils using a high-temperature superconducting (HTS) wires with high current density generate high magnetic field of 2 to 5 [T] and electromagnetic force (Lorentz force) acting on the superconducting field coils also become a very strong from the point of view of a mechanical characteristics. Because mechanical stress caused by these powerful electromagnetic force is one of the factors which worsens the critical current performance and structural characteristics of HTS wire, the mechanical stress analysis should be performed when designing the superconducting field coils. In this paper, as part of structural design of superconducting field coils for 17 MW class superconducting ship propulsion motor, mechanical stress acting on the superconducting field coils was analyzed and structural safety was also determined by the coupling analysis system that is consists of commercial electromagnetic field analysis program and structural analysis program.