• Title/Summary/Keyword: Fiducial

Search Result 127, Processing Time 0.02 seconds

Automated Determination of Prostate Depth for Planning in Proton Beam Treatment (양성자치료에서의 종양의 위치 및 깊이 검출 자동화 시스템에 관한 연구)

  • Cheong, Min-Ho;Yoon, Myong-Geun;Kim, Jin-Sung;Shin, Dong-Ho;Park, Sung-Yong;Lee, Se-Byeong
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.180-190
    • /
    • 2009
  • Depth of prostate volume from the skin can vary due to intra-fractional and inter-fractional movements, which may result in dose reduction to the target volume. Therefore we evaluated the feasibility of automated depth determination-based adaptive proton therapy to minimize the effect of inter-fractional movements of the prostate. Based on the center of mass method, using three fiducial gold markers in the prostate target volume, we determined the differences between the planning and treatment stages in prostate target location. Thirty-eight images from 10 patients were used to assess the automated depth determination method, which was also compared with manually determined depth values. The mean differences in prostate target location for the left to right (LR) and superior to inferior (SI) directions were 0.9 mm and 2.3 mm, respectively, while the maximum discrepancies in location in individual patients were 3.3 mm and 7.2 mm, respectively. In the bilateral beam configuration, the difference in the LR direction represents the target depth changes from 0.7 mm to 3.3 mm in this study. We found that 42.1%, 26.3% and 2.6% of thirty-eight inspections showed greater than 1 mm, 2 mm and 3 mm depth differences, respectively, between the planning and treatment stages. Adaptive planning based on automated depth determination may be a solution for inter-fractional movements of the prostate in proton therapy since small depth changes of the target can significantly reduce target dose during proton treatment of prostate cancer patients.

  • PDF

Patient-Specific Quality Assurance in a Multileaf Collimator-Based CyberKnife System Using the Planar Ion Chamber Array

  • Yoon, Jeongmin;Lee, Eungman;Park, Kwangwoo;Kim, Jin Sung;Kim, Yong Bae;Lee, Ho
    • Progress in Medical Physics
    • /
    • v.29 no.2
    • /
    • pp.59-65
    • /
    • 2018
  • This paper describes the clinical use of the dose verification of multileaf collimator (MLC)-based CyberKnife plans by combining the Octavius 1000SRS detector and water-equivalent RW3 slab phantom. The slab phantom consists of 14 plates, each with a thickness of 10 mm. One plate was modified to support tracking by inserting 14 custom-made fiducials on surface holes positioned at the outer region of $10{\times}10cm^2$. The fiducial-inserted plate was placed on the 1000SRS detector and three plates were additionally stacked up to build the reference depth. Below the detector, 10 plates were placed to avoid longer delivery times caused by proximity detection program alerts. The cross-calibration factor prior to phantom delivery was obtained by performing with 200 monitor units (MU) on the field size of $95{\times}92.5mm^2$. After irradiation, the measured dose distribution of the coronal plane was compared with the dose distribution calculated by the MultiPlan treatment planning system. The results were assessed by comparing the absolute dose at the center point of 1000SRS and the 3-D Gamma (${\gamma}$) index using 220 patient-specific quality assurance (QA). The discrepancy between measured and calculated doses at the center point of 1000SRS detector ranged from -3.9% to 8.2%. In the dosimetric comparison using 3-D ${\gamma}$-function (3%/3 mm criteria), the mean passing rates with ${\gamma}$-parameter ${\leq}1$ were $97.4%{\pm}2.4%$. The combination of the 1000SRS detector and RW3 slab phantom can be utilized for dosimetry validation of patient-specific QA in the CyberKnife MLC system, which made it possible to measure absolute dose distributions regardless of tracking mode.

Fabrication of passive-aligned optical sub-assembly for optical transceiver using silicon optical bench (실리콘 광학벤치를 사용한 수동정렬형 광송수신기용 광부모듈의 제작)

  • Lee, Sang-Hwan;Joo, Gwan-Chong;Hwang, nam;moon, Jong-Tae;Song, Min-Kyu;Pyun, Kwang-Eui;Lee, Yong-Hyun
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.6
    • /
    • pp.510-515
    • /
    • 1997
  • Packaging takes an extremely important element of optical module cost due primarily to the added complication of alignment between semiconductor devices and optical fiber, and many efforts have been devoted on reducing the cost by eliminating the complicated optical alignment procedures in passive manner. In this study, we fabricated silicon optical benches on which the optical alignments are accomplished passively. To improve the positioning accuracy of a flip-chip bonded LD, we adopted fiducial marks and solder dams which are self-aligned with V-groove etch patterns, and a stand-off to control the height and to improve the heat dissipation of LD. Optical sub-assemblies exhibited an average efficiency of -11.75$\pm$1.75 dB(1$\sigma$) from the LD-to-single mode fiber coupling and an average sensitivity of -35.0$\pm$1.5 dBm from the fiber and photodetector coupling.

  • PDF

The Fish Community and Habitat Analysis in the Bongseonsa Stream within Gwangneung Forest, South Korea (광릉숲 내 봉선사천의 어류군집 및 서식처 분석)

  • Wang, Ju Hyoun;Kim, Jeong Eun;Choi, Jun Kil;Lee, Hyuk Je;Cho, Yong Chan;Lee, Hwang Goo
    • Korean Journal of Environmental Biology
    • /
    • v.35 no.2
    • /
    • pp.105-115
    • /
    • 2017
  • The present study is to understand the Bongseonsa stream in the National Arboretum fish fauna variation through comparison with historical data and to evaluate the stream health situated. We performed investigations over three times from April to September 2015. In the survey, 2,960 individuals which belonging to 22 species, 8 families were collected. Dominant species by number was Zacco platypus and subdominant species was Zacco koreanus. Seven Korean endemic species (Squalidus gracilis majimae, Microphysogobio yaluensis, Zacco koreanus, Koreocobitis rotundicausata, etc) were observed and showed a ratio of 36.4%. The community analysis revealed that the structure of fish community in the study sampling sites was instability in having dominance 0.79 (${\pm}0.15$), diverse 1.21 (${\pm}0.60$), evenness 0.58 (${\pm}0.15$) and species richness 1.49 (${\pm}0.83$). The values in the Qualitative Habitat Evaluation Index (QHEI) was averagely 122.9 (${\pm}44.8$) in the Bongseonsa stream and this was showed to have favorable habitat surroundings. As a result of tolerance guild analysis, the total number of sensitive species and intermediate species were higher than tolerant species. Analysis was divided into A and B two groups of fiducial 12.25% in Cluster analysis degree of similarity between study sampling sites. Fish Assessment Index (FAI) was rated A and B grade in Bongseonsa stream that stream health showed favorable. However Wangsuk stream as a urban stream rated C grade and analysed the lowest grade in the whole study sampling sites. There was high correlation beteween FAI and various indexes, dominance, diverse, evenness and sensitive species and intermediate species.

Analysis on the Positional Accuracy of the Non-orthogonal Two-pair kV Imaging Systems for Real-time Tumor Tracking Using XCAT (XCAT를 이용한 실시간 종양 위치 추적을 위한 비직교 스테레오 엑스선 영상시스템에서의 위치 추정 정확도 분석에 관한 연구)

  • Jeong, Hanseong;Kim, Youngju;Oh, Ohsung;Lee, Seho;Jeon, Hosang;Lee, Seung Wook
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.143-152
    • /
    • 2015
  • In this study, we aim to design the architecture of the kV imaging system for tumor tracking in the dual-head gantry system and analyze its accuracy by simulations. We established mathematical formulas and algorithms to track the tumor position with the two-pair kV imaging systems when they are in the non-orthogonal positions. The algorithms have been designed in the homogeneous coordinate framework and the position of the source and the detector coordinates are used to estimate the tumor position. 4D XCAT (4D extended cardiac-torso) software was used in the simulation to identify the influence of the angle between the two-pair kV imaging systems and the resolution of the detectors to the accuracy in the position estimation. A metal marker fiducial has been inserted in a numerical human phantom of XCAT and the kV projections were acquired at various angles and resolutions using CT projection software of the XCAT. As a result, a positional accuracy of less than about 1mm was achieved when the resolution of the detector is higher than 1.5 mm/pixel and the angle between the kV imaging systems is approximately between $90^{\circ}$ and $50^{\circ}$. When the resolution is lower than 1.5 mm/pixel, the positional errors were higher than 1mm and the error fluctuation by the angles was greater. The resolution of the detector was critical in the positional accuracy for the tumor tracking and determines the range for the acceptable angle range between the kV imaging systems. Also, we found that the positional accuracy analysis method using XCAT developed in this study is highly useful and will be a invaluable tool for further refined design of the kV imaging systems for tumor tracking systems.

Real-time Body Surface Motion Tracking using the Couch Based Computer-controlled Motion Phantom (CBMP) and Ultrasonic Sensor: A Feasibility Study (CBMP (Couch Based Computer-Controlled Motion Phantom)와 초음파센서에 기반한 실시간 체표면 추적 시스템 개발: 타당성 연구)

  • Lee, Suk;Yang, Dae-Sik;Park, Young-Je;Shin, Dong-Ho;Huh, Hyun-Do;Lee, Sang-Hoon;Cho, Sam-Ju;Lim, Sang-Wook;Jang, Ji-Sun;Cho, Kwang-Hwan;Shin, Hun-Joo;Kim, Chul-Yong
    • Progress in Medical Physics
    • /
    • v.18 no.1
    • /
    • pp.27-34
    • /
    • 2007
  • Respiration sating radiotherapy technique developed In consideration of the movement of body surface and Internal organs during respiration, is categorized into the method of analyzing the respiratory volume for data processing and that of keeping track of fiducial landmark or dermatologic markers based on radiography. However, since these methods require high-priced equipments for treatment and are used for the specific radiotherapy. Therefore, we should develop new essential method whilst ruling out the possible problems. This study alms to obtain body surface motion by using the couch based computer-controlled motion phantom (CBMP) and US sensor, and to develop respiration gating techniques that can adjust patients' beds by using opposite values of the data obtained. The CBMP made to measure body surface motion is composed of a BS II microprocessor, sensor, host computer and stopping motor etc. And the program to control and operate It was developed. After the CBMP was adjusted by entering random movement data, and the phantom movements were acquired using the sensors, the two data were compared and analyzed. And then, after the movements by respiration were acquired by using a rabbit, the real-time respiration gating techniques were drawn by operating the phantom with the opposite values of the data. The result of analysing the acquisition-correction delay time for the data value shows that the data value coincided within 1% and that the acquistition-correction delay time was obtained real-time $(2.34{\times}10^{-4}sec)$. And the movement was the maximum movement was 6 mm In Z direction, In which the respiratory cycle was 2.9 seconds. This study successfully confirms the clinical application possibility of respiration gating techniques by using a CBWP and sensor.

  • PDF

Analysis of the Inter- and Intra-treatment Isocenter Deviations in Pelvic Radiotherapy With Small Bowel Displacement System (Small Bowel Displacement System을 이용한 골반부 방사선조사에서 치료간 및 치료중 중심점 위치변동에 관한 분석)

  • Kim Moon Kyung;Kim Dae Yong;Ahn Yong Chan;Huh Seung Jae;Lim Do Hun;Shin Kyung Hwan;Lee Kyu Chan
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.114-119
    • /
    • 2000
  • Purpose : To evaluate the e지ent and frequency of the inter- and intra-treatment isocenter deviations of the whole pelvis radiation field in using small bowel displacement system (SBDS). Methods and Materials : Using electronic portal imaging device (EPID), 302 postero-anterior 232 lateral portal images were prospectively collected from 11 patients who received pelvic radiation therapy (7 with cervix cancer and 4 with rectal cancer). All patients were treated in prone position with SBDS under the lower abdomen. Five metallic fiducial markers were placed on the image detection unit for the recognition of the isocenter and magnification. After aligning the bony landmarks of the EPID images on those of the reference image, the deviations of the isocenter were measured in right-left (RL), cranio-caudal (CC), and PA directions. Results : The mean inter-treatment deviation of the isocenter in each RL, CC, and PA direction was 1.2 mm ($\pm$ 1.6 mm), 1.0 mm ($\pm$3.0 mm), and 0.9 mm ($\pm$4.4 mm), respectively. Inter-treatment isocenter deviations over 5 mm and 10 mm in RL, CC, and PA direction were 2, 12, 24$\%$, and 0, 0, 5$\%$, respectively. Maximal deviation was detected in PA direction, and was 11.5 mm. The mean intratreatment deviation of the isocenter in RL, CC, and PA direction was 0 mm ($\pm$0.9 mm), 0.1 mm ($\pm$ 1.9mm), and 0 mm ($\pm$1.6 mm), respectively. All intra-treatment isocenter deviations over 5 mm in each direction were 0, 1, 1$\pm$, respectively. Conclusions : As the greatest and the most frequent inter-treatment deviation of the isocenter was along the PA direction, it is recommended to put more generous safety margin toward the PA direction on the lateral fields if clinically acceptable in pelvic radiotherapy with SBDD.

  • PDF