• Title/Summary/Keyword: Fiber-reinforced matrix

Search Result 635, Processing Time 0.025 seconds

Comparisons of Elasto-Fiber and Fiber & Bernoulli-Euler reinforced concrete beam-column elements

  • Karaton, Muhammet
    • Structural Engineering and Mechanics
    • /
    • v.51 no.1
    • /
    • pp.89-110
    • /
    • 2014
  • In this study, two beam-column elements based on the Elasto-Fiber element theory for reinforced concrete (RC) element have been developed and compared with each other. The first element is based on Elasto Fiber Approach (EFA) was initially developed for steel structures and this theory was applied for RC element in there and the second element is called as Fiber & Bernoulli-Euler element approach (FBEA). In this element, Cubic Hermitian polynomials are used for obtaining stiffness matrix. The beams or columns element in both approaches are divided into a sub-element called the segment for obtaining element stiffness matrix. The internal freedoms of this segment are dynamically condensed to the external freedoms at the ends of the element by using a dynamic substructure technique. Thus, nonlinear dynamic analysis of high RC building can be obtained within short times. In addition to, external loads of the segment are assumed to be distributed along to element. Therefore, damages can be taken account of along to element and redistributions of the loading for solutions. Bossak-${\alpha}$ integration with predicted-corrected method is used for the nonlinear seismic analysis of RC frames. For numerical application, seismic damage analyses for a 4-story frame and an 8-story RC frame with soft-story are obtained to comparisons of RC element according to both approaches. Damages evaluation and propagation in the frame elements are studied and response quantities from obtained both approaches are investigated in the detail.

Sliding Wear and Friction Properties of Composite Materials for Friction Bushing (Friction Bushing용 복합재료의 미끄럼 마찰마모특성에 관한 연구)

  • Lee Han-Young;Heo Dae-Hong;Kim Tae-Jun;Cho Yong-Jae;Cho Bum-Rae;Hur Man-Dae
    • Tribology and Lubricants
    • /
    • v.22 no.1
    • /
    • pp.1-7
    • /
    • 2006
  • The sliding friction and wear properties of mineral fiber reinforced composite(MF) and glass fiber reinforced composites(GF) are investigated to clarify their field of use and the role of each fiber in friction material. Friction and wear test reveals that GF composite has better wear resistance even though with low friction coefficient, comparing with MF composite. Glass fiber strengthen effectively the matrix and may absorb friction energy to convert it into the fracture energy of them, as well as its lubricative role. However, mineral fiber in MF composite is too small to strengthen the matrix. Then MF composite are easily plowed and worn out by asperity on counter material. Friction coefficient of MF composite is higher friction coefficient than that of GF composite and varied widely with test.

Direct Tensile Properties of Fiber-Reinforced Cement Based Composites according to the Length and Volume Fraction of Amorphous Metallic Fiber (비정질 강섬유의 길이 및 혼입률에 따른 섬유보강 시멘트복합체의 직접인장특성)

  • Kim, Hong-Seop;Kim, Gyu-Yong;Lee, Sang-Kyu;Choe, Gyeong-Cheol;Nam, Jeong-Soo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.3
    • /
    • pp.201-207
    • /
    • 2019
  • In this study, the direct tensile properties of amorphous metallic fiber-reinforced cement based composites according to the strain was evaluated. A thin plate-shape amorphous metallic fiber with 15mm and 30mm in length was used. And fiber-reinforced cement based composites were prepared with contents of 1.0, 1.5, 2.0%. The direct tensile test was conducted under the conditions of $10^{-6}/s(static)$ and $10^1/s(dynamic)$ strain rate. As a results, amorphous metallic fiber with a length of 15mm was observed in pull-out behavior from the cement matrix because of the short fiber length and large portion of mixed fiber. On the other hand, amorphous metallic fiber with a length of 30mm were not pulled out from matrix because the bonding force between the fiber and matrix was large due to rough surface and large specific surface area. However, fracture occurred because thin plate shape fibers were vulnerable to shear force. Tensile strength, strain capacity and toughness were improved due to the increase in the fiber length. The dynamic increase factor of L15 was larger that of L30 because the bonding performance of the fiber-matrix interface is significantly affected by the strain rate.

Influencing Factors on Toughness of Ring Type Fiber Concrete (원형강섬유 콘크리트의 인성 영향요인)

  • Choi, Oan-Chul;Lee, Cha-Don;Hur, Jun;Kim, Su-Hyen
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.55-60
    • /
    • 2001
  • Influencing factors on flexural toughness of ring-type fiber reinforced concrete(RSFRC) are investigated. An experiment proceeding ASTM C 78 is peformed to make a comparison between ring-type fibers and double-hook type fibers. Most specimen with ring type fibers have failed by the cone type failure, while discrete hook type fibers have failed by fiber pullout. For the hook-type fiber reinforced concrete(SFRC), the first crack load increases, as the fiber mixing volume increases. Aspect ratio(fiber length/fiber diameter) is critical for hook type fibers, so the flexural toughness increases significantly, as the length of fiber increases. However, for the ring type, the toughness indices Increase as the number of fibers in the specimen increases. Since there is no bond problem between the ring fiber and the concrete matrix, the aspect ratio does not affect the performance of the composite material with the newly developed steel fibers. Influencing factors with respect to flexural toughness RSFRC were observed to be ring diameter, diameter of steel fiber and fiber content.

  • PDF

Evaluation of Crack Control Performance of the Concrete with Fiber Combination (섬유혼입 조건에 따른 콘크리트의 균열제어 성능 평가)

  • Park, Jae-Yong;Lee, Myoung-Ho;Kang, Byung-Hoi;Kim, Kyoung-Hoon;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.21-22
    • /
    • 2013
  • Nowadays, the fiber which mixed with concrete matrix always has low adhesion with cement paste. It's difficult to use fiber to reinforce the structure. For more adding fiber in concrete would cause some problems as the low flowability and surface polishing. Further study is needed in fiber using. In this research, further study in fiber reinforced concrete has been invested. Various fibers with different properties have been used to prevent cracking. Fiber reinforced concrete's fundamental properties as slump, air content, compressive strength and tensile strength have been tested. Optimum type of the fiber and optimum addition ratio of fiber has been invested to increase the utility of the fiber which used in concrete.

  • PDF

The Strength Characteristics of Polymer Composites Injection Parts for Lightness and Safety (경량화와 안전을 위한 폴리머 복합재료 사출품의 강도특성)

  • Yun, Yeo-Kwon;Kim, Jin-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.4
    • /
    • pp.101-108
    • /
    • 2011
  • In this paper deals with strength of glass fiber reinforced plastics produced by shouting machine was investigated by universal testing instrument. We can obtain following results by performing the strength evaluation of polymer composite material according as varied environment temperature. The effect of environmental temperature on Strength properties was more sensitive in the weld specimen than parent. When changed environmental temperature, variation of strength in the parent was much bigger than it of weld specimen, that is, matrix in the parent, orientation in the specimen ware more sensitive to environmental strength. Tensile strength of polycarbonate matrix was similar regardless of mold temperature.

Effect of Gas Pressure Infiltration on Microstructure of Continuous Fiber Reinforced Al Matrix Composite Wire (연속섬유 강화 Al기 복합재료 선재의 미세조직에 미치는 가스압의 영향)

  • Kim, Jung-Hoon;Jung, Dong-Suk;Kim, Jin-Gon;Kim, Byung-Geol
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.617-618
    • /
    • 2005
  • The main purpose of this study is to investigate the effect of gas pressure infiltration on microstructure. Continuous fiber reinforced Al matrix composite wire is produced by gas pressure infiltration process. With the increase of gas pressure, porosity and wettabillity was improved. No chemical reaction product was detected at the interface of $Al_2O_3$ and Al.

  • PDF

A Study on the Tensile Strength of Glass Woven Fiber Reinforced PET Composites (직조유리섬유강화 PET수지 복합체의 인장특성에 관한 연구)

  • 김홍건;최창용
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.1
    • /
    • pp.45-49
    • /
    • 2003
  • Tensile strength of the woven glass fiber reinforced PET (Poly-Ethylene-Terephthalate) matrix composite manufactured by rapid press consolidation technique was investigated and evaluated. During pre-heating, consolidation and solidification stages, the optimal manufacturing conditions for this composite were discussed based on the void content and tensile properties depending on vacuum condition. It is found that the effect of vacuum condition during preheating gives a substantial difference on the strength as well as microstructure. It is also found that the failure micromechanism shows several energy absorption processes enhancing fracture toughness.

Experimental Study on the Properties of High Performance Fiber Reinforced Cementitious Composite with PP and PE Fiber (PP섬유와 PE섬유를 혼입한 고인성 섬유보강 시멘트 복합체의 특성에 관한 실험적 연구)

  • Byun, Jang-Bae;Lee, Won-Suk;Jeon, Esther;Kim, Sun-Woo;Yun, Hyun-Do
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.381-384
    • /
    • 2006
  • Fibers are increasingly being used for the reinforcement of cementitious matrix to enhance the toughness and energy absorption capacity and to reduce the cracking sensitivity of the matrix. In the past decade, high performance fiber reinforced cementitious composite(HPFRCC) have evolved with intensified research. HPFRCC for structural applications has been developed under the performance driven design approach. It is the aim of this study to obtain development of hybrid-HPFRCC using polypropylene fibers and polyethylene fibers. It was targeted the requirement of economical mixing and application to structure member.

  • PDF

A study on the bending strength characteristics of steel bar and GFRP rebar in salt water surroundings (해수 환경에서의 철근과 GFRP 리바의 굽힘 강도 특성에 관한 연구)

  • Han, Gil-Young;Lee, Dong-Gi;Kwak, Sang-Muk;Bae, Si-Yon;Kim, Ki-Sung
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.354-358
    • /
    • 2002
  • This paper describes the need for a ductile Fiber Reinforced Plastics (FRP) reinforcement for concrete structures. To promte the degradation of the adhesive condition at the fiber/matrix micro interface without matrix dissolution loss were carried out in salt water surrounding. The absorption properties and the bending strength were compared about GFRP rebar and steel bar.

  • PDF