• 제목/요약/키워드: Fiber-Optic

검색결과 1,082건 처리시간 0.025초

분포형 광섬유 센서를 이용한 풍력발전기의 기계적 부하 측정 및 모니터링 (Measurement and Monitoring of Mechanical Loads of Wind Turbines Using Distributed Fiber Optic Sensor)

  • 이종원;허영철;남용윤;이근호;김유성;이용배
    • 한국소음진동공학회논문집
    • /
    • 제17권11호
    • /
    • pp.1028-1036
    • /
    • 2007
  • A method for measurement and monitoring of mechanical loads in large slender structures such as wind turbine blade and tower is presented based on continuous strain data obtained from distributed fiber optic sensor. An experimental study was carried out on an aluminum cantilever beam. A static load test was performed and the calculated moment from the distributed fiber optic sensor agree well with the actual applied moment. A series of damages was inflicted on the beam, and vibration tests were carried out for each damage case. The estimated natural frequencies from the distributed fiber optic sensor for each damage case are found to compare well with those from a conventional accelerometer and a numerical analysis based on an energy method.

수용액 환경에서 수은 측정을 위한 로다민 기반의 광섬유 센서 개발 (Development of Rhodamine-Based Fiber Optic Sensor for Detection of Mercury in Aqueous Environments)

  • 이애리;김용일;김범규;박병기
    • 센서학회지
    • /
    • 제23권3호
    • /
    • pp.173-177
    • /
    • 2014
  • A Rhodamine-based fiber-optic sensor has been developed to detect mercury ions in aqueous environments. The fiber-optic sensor was composed of a mercury-sensing thin film, plastic optical fibers, and a spectrometer. The mercury-sensing thin film with the synthesized Rhodamine derivatives was fabricated with Sol-Gel process. A light emitted by a light source is guided by plastic optical fibers into the thin film in an aqueous solution and a reflected light is analyzed with the spectrometer. The experiment exhibits that an absorbance in the thin film is increased as mercury concentration is increased in the solution and the absorbance by mercury is higher than that by other heavy metals. The fiber-optic sensor exhibits high chromogenic phenomenon of mercury ions among various heavy metals and the correlation between absorbance and mercury concentration in the aqueous environments.

가변 페브리-페로 필터와 FBG를 이용한 광세기 기반 자기기준 광섬유 센서 (An Intensity Based Self-referencing Fiber Optic Sensor Using Tunable Fabry-Perot Filter and FBG)

  • 최상진;반재경
    • 전자공학회논문지
    • /
    • 제50권3호
    • /
    • pp.146-152
    • /
    • 2013
  • 본 논문에서는 자기기준 특성을 가지는 광세기 기반 광섬유 센서 구조를 제안하고 실험적으로 구현하여 성능을 제시한다. 제안하는 광섬유 센서는 광대역 광원(BLS), fiber Bragg grating (FBG), 가변 페브리-페로(Fabry-Perot) 필터, LabVIEW 프로그램으로 구성된다. 제안한 자기기준 광섬유 센서의 이론적인 해석을 통하여 측정 변수(X)와 보정 변수(${\beta}$)를 정의하고, 이를 바탕으로 전달함수(H)를 구한다. 또한 실험을 통하여 이론적인 해석의 타당성을 제시한다. 제안한 광섬유 센서 구조는 광대역 광원의 출력 광세기가 0 dB, 3 dB, 6 dB 감소해도 측정결과에 영향을 미치지 않는 자기기준 특성을 가진다. 또한 다른 특성의 FBG를 사용하여도 측정 가능하므로, 제안한 광섬유 센서 구조는 임의의 규격을 가진 FBG를 사용할 수 있다. 광원의 광세기가 감소하였을 때와 세 가지 다른 특성의 FBG 쌍을 이용하여 측정한 결과 이론적인 값과 잘 일치함을 보였다. 따라서 제안한 광섬유 센서는 자기기준 특성과 구성하는 FBG의 규격이 비교적 엄격하지 않아도 되는 장점을 가진다.

광섬유 생물센서에 의한 혈액 중 포도당 및 젖산 모니터링

  • 손옥재;김진희;임용식;서국화;정상윤;이종일
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2003년도 생물공학의 동향(XII)
    • /
    • pp.627-629
    • /
    • 2003
  • In this work fiber-optic biosensor that has been used in medical applications was developed. And we can monitored the concentration of glucose and lactate in blood sample by using developed fiber-optic glucose and lactate sensor. Glucose oxidase(GOD) and Lactate oxidase(LOD) were immobilized by using acrylamide adhesive and zeolite on the tip of the optic fiber.

  • PDF

광파이버 자이로의 동특성 해석 (Analysis of Dynamic Characteristics in a Fiber Optic Gyro)

  • 정삼;권용수;김성진;이상식;진상윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.80-82
    • /
    • 1997
  • An analytical study of the Dynamic Characteristics of a Fiber Optic Gyro is presented. A mathematical model appropriate to the Fiber Optic Gyro system suffering from the system vibration of a driving motor is derived. It is shown that the analysis is directly applicable to the Gyrocompass system.

  • PDF

Compensation of Electric Field Interference for Fiber-optic Voltage Measurement System

  • Cho, Jae-Kyong
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권2호
    • /
    • pp.84-88
    • /
    • 2008
  • In this paper, we analyze the errors associated with electric field interference for fiber-optic voltage sensors working in a three-phase electric system. For many practical conductor arrangements, the electric filed interference may cause errors unacceptable for the accuracy requirements of the sensors. We devised a real time compensation method for the interference by introducing geometric and weight factors. We realized the method using simple electronic circuits and obtained the real time compensated outputs with errors of 1 %.

Optimal Design of Fiber-optic Surface Plasmon Resonance Sensors

  • Jung, Jae-Hoon;Kim, Min-Wook
    • Journal of the Optical Society of Korea
    • /
    • 제11권2호
    • /
    • pp.55-58
    • /
    • 2007
  • We propose a systematic method for design of fiber-optic surface plasmon resonance (SPR) sensors. We used rigorous coupled wave analysis (RCWA) for analysis of the transmission spectrum, and the (1+1) evolution strategy (ES) was employed as an optimization tool. The simulation results show that the optimization method presented here is very useful in designing fiber-optic SPR sensor for strain and temperature measurement. This algorithm can be extended to another objective function with other weighting factors and optical parameters.

광섬유를 이용한 고감도 압력센서 개발 (Development of high sensitivity pressure sensor using optical fiber)

  • 이권형;조경재;김현철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.478-481
    • /
    • 1995
  • This paper presents the system demonstrator for an optical fiber sensor system developed as a technological evaluator suitable for generic sensric sensing applications. The new type of fiber-optic sensor employed a diaphragm displacement transforms pressure into optical intensity. Form this sensing technique, we can know the variation of source intensity, the loss of a optical fiber, and the reflectivity of the diaphragm surface. Experimental results are applied to the low-pressure transducer suitable for measuring miniature pressure.

  • PDF

Measurement of Thermo-Optic Coefficient of a Liquid Using a Cascade of Two Different Fiber Bragg Gratings

  • Kim, Kwang Taek;Kim, In Soo
    • 센서학회지
    • /
    • 제22권2호
    • /
    • pp.95-99
    • /
    • 2013
  • We proposed and demonstrated a fiber optic sensor for detecting the thermo-optic coefficient of a liquid, based on a cascade of two different FBGs. One of the two FBGs was etched, and its cladding was removed, for evanescent wave coupling with an external liquid. The Bragg wavelength of the non-etched FBG was used as a reference for the temperature of the surrounding liquid. The refractive index (RI) and thermo-optic (T-O) coefficient of a liquid can be detected from the difference between the Bragg wavelengths of the two FBGs, and the variation of the difference in accordance with temperature.