• Title/Summary/Keyword: Fiber-Optic

Search Result 1,082, Processing Time 0.02 seconds

High Sensitive Fiber Optic Temperature Sensor Based on a Side-polished Single-mode Fiber Coupled to a Tapered Multimode Overlay Waveguide

  • Prerana, Prerana;Varshney, Ravendra Kumar;Pal, Bishnu Pada;Nagaraju, Bezwada
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.337-341
    • /
    • 2010
  • A high sensitivity fiber optic temperature sensor based on a side-polished fiber (SPF) coupled to a tapered multimode overlay waveguide (MMOW) is proposed and studied. Both tapered and non-tapered MMOW were considered to study the effect of tapering of MMOW on the characteristics of the device and to investigate the criticality of the uniformity of the multimode overlay waveguide over the SPF. Present study shows that tapering of the MMOW can be used to tune the desired wavelength range without any loss in the sensitivity. Sensitivity up to 9 nm/$^{\circ}C$ within the temperature range of 25 to $100^{\circ}C$ can be achieved with the proposed sensor, almost 6 times higher compared even to state-of-the-art high-sensitivity grating-based fiber optic temperature sensors.

Fiber-Optic Distributed Overheating Detection Sensor Using an Optical Time Domain Refrectometry (광시간영역 반사계를 이용한 분포형 광섬유 과열 감지 센서)

  • Kim, Dae Hyun;Kim, Kwang Taek
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.297-301
    • /
    • 2013
  • We proposed and demonstrated a distributed fiber-optic overheating detection sensor using optical time domain refrectometry. With increased of temperature the optical fiber is bended by a bi-metal and it result in optical leaky loss of the fiber. The sensor structure is designed in such a way that the signal of overheating is happen when the temperature exceeding a threshold temperature and the optical fiber is protected from excess bending.

The Optimal Design of POF Optical Connector for Medical Image Transmission System (의료영상전송시스템을 위한 POF 광커넥터의 최적 설계)

  • Cheon, Min-Woo;Cho, Kyung-Jae;Park, Yong-Pil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.12
    • /
    • pp.978-982
    • /
    • 2010
  • For mass information transfer, the optical communication using optic fiber has been widely used. Especially, in the field of medical image, the large data is digitalized based on the standard image and it is used for telemedicine with this method. Therefore, to transfer the large amount of data fast and effectively POF (Plastic Optical Fiber) can be used and the development of optic connector for connection between POFs is very important. In this study, for stable optical coupling of POF optic fiber Ferrule and Sleeve were designed and produced by considering the bond stability and the insertion loss according to the physical contact and roughness profile was evaluated. As a result of examining the insertion loss by physical contact method of two optic fibers, it showed the loss was about 1.895dB. According to the results from studying the condition of grinding section for POF mass production, the mass production condition was established as POF profile roughness of 6nm and the loss of 0.2dB or lower by controlling the film size and time step by step.

Development of Fiber-optic Radiation Sensor Using LYSO Scintillator for Gamma-ray Spectroscopy (LYSO 섬광체를 이용한 감마선 분광용 광섬유 방사선 센서의 개발)

  • Han, Ki-Tek;Yoo, Wook-Jae;Shin, Sang-Hun;Jeon, Da-Yeong;Park, Jang-Yeon;Park, Byung-Gi;Lee, Bong-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.287-292
    • /
    • 2012
  • A fiber-optic radiation sensor was fabricated using a sensing probe, a plastic optical fiber, a photomultiplier tube, and a multichannel analyzer for gamma-ray spectroscopy. As an inorganic scintillator of the sensing probe, a LYSO crystal was used. In this study, we obtained the relationship between the photon counts of the fiber-optic radiation sensor and the activity of the radioactive isotope. In addition, the gamma-ray energy spectra were also measured using a fiber-optic radiation sensor to discriminate species of gamma-ray emitters.

Fixation Method of Prestressed Fiber Optic Sensor (광섬유센서의 프리스트레인 부가 고정방식)

  • Kim, Ki-Soo
    • Composites Research
    • /
    • v.25 no.6
    • /
    • pp.211-216
    • /
    • 2012
  • FBG sensor peaks could be split due to polarization by shear strain, when the fiber optic sensors embedded or attached to the structure. For the fiber optic sensor packages, sensor grating has to be protected from shear strains. Also, pretension has to be applied to the sensor because compressive strain must be measured. Without pretension of sensor, the sensor does not show any change of signal until it is stretched. In order to mesure compressive and tensile strains, two fixing point and prestressed sensor need. In the fixing point, just holding the optical fiber cause slip between core and cladding in the fiber. A Fixation method of prestressed FBG sensors fixed with partially stripped fibers was developed. The sensor package has the prestress controllable fixtures at the fixing points. Prestress to the sensor imposed by controlling the two fixed points with bolts and nuts make it easy to measure compressive strain as well as tensile strain. The fiber optic sensor packages applied to the actual structure and the structural monitoring system using the package can be applied to safety through surveillance.

Non-contact Detection of Ultrasonic Waves Using Fiber Optic Sagnac Interferometer (광섬유 Sagnac 간섭계를 이용한 초음파의 비접촉식 감지)

  • Lee, Jeong-Ju;Jang, Tae-Seong;Lee, Seung-Seok;Kim, Yeong-Gil;Gwon, Il-Beom;Lee, Wang-Ju
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.9
    • /
    • pp.1400-1409
    • /
    • 2001
  • This paper describes a fiber optic sensor suitable for non-contact detection of ultrasonic waves. This sensor is based on a fiber optic Sagnac interferometer. Quadrature phase bias between two interfering laser beams in Sagnac loop is introduced by a polarization controller. A stable quadrature phase bias can be confirmed by observing the interferometer output versus phase bias. This method eliminates a digital signal processing for detection of ultrasonic waves using Sagnac interferometer. Interference intensity is affected by the frequency of ultrasonic waves and the time delay of Sagnac loop. Collimator is attached to the end of the probing fiber to focus the light beam onto the specimen surface and to collect the reflected light back into the fiber probe. Ultrasonic waves produced by conventional ultrasonic transducers are detected. This fiber optic sensor based on Sagnac interferometer is very effective for detection of small displacement with high frequency such as ultrasonic waves used in conventional non-destructive testing.

Demodulation of FBG and Acoustic Sensors Embedded in a Fiber-Optic Sagnac Loop (광섬유 사낙간섭계에 삽입된 광섬유격자센서와 음향센서의 복조)

  • Kim, Hyun-Jin;Lee, June-Ho;Song, Min-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.2
    • /
    • pp.44-50
    • /
    • 2012
  • When the fiber Bragg gratings are embedded in a fiber-optic Sagnac loop for measuring temperature or strain, it is difficult to separate the Bragg wavelengths. The transmitted light is mixed with the reflected Bragg wavelengths in the photo-detector, working as noises. To suppress the noises, we placed the FBG sensors and a fiber-optic attenuator at asymmetric positions in the loop. With the arrangement the reflected light became much bigger than the transmitted light, enabling the separation of the reflected Bragg wavelengths with almost the same signal-to-noise ratio of the FBG sensors outside the loop.

Development and Performance Property Investigation of Lighting System using Plastic Optical Fiber (플라스틱 광섬유를 이용한 조명시스템 개발과 특성 분석)

  • Shin, Sang-Uk;Yi, Chin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.25-32
    • /
    • 2010
  • Compared to general lighting method, the lighting system that uses optic fiber can provide only the visible light of good quality to subject by eliminating ultraviolet ray and infrared ray. Thanks to this merit, it is possible to prevent the hard phenomenon of subject caused by ultraviolet ray and infrared ray and to provide the agreeable light environment. This study developed indoors illumination system of high color rendering on the basis of plastic optic fiber with excellent optical property and processing to substitute halogen lamp which has been used for excellent color rendering in spite of low efficiency and short life. Producing pilot product of the designed illumination system and evaluating the property of electric and optical property, ultraviolet ray radiation quantity and temperature property, this study verified the excellence of suggested lighting system of plastic optic fiber.

Fiber optic circular polarizing mirror using polymer cholesteric liquid crystal and it's application in the mode-locked fiber laser (콜레스테릭 액정 폴리머 박막을 이용한 광섬유 원편광 거울 제작 및 이를 이용한 모드 록킹 된 광섬유 레이저)

  • 장도일;김경헌;김인선;김성태
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.2
    • /
    • pp.91-96
    • /
    • 2000
  • We propose a novel in-line fiber optic circular polarizing mirror utilizing cholesteric lIquid crystal (CLC) polymer [11m for the fiber laser applications. Ions matrix representation of this device has been derived and venfied experimentally. In a Fabry-Perot cavity configuration, a CLC fiber optic rmrror has been used to achieve longitudinal mode suppression as well as to obtain passively mode~locked laser operations with 630 fs laser pulses via nonlinear polarization evoluhon.oluhon.

  • PDF

Analysis of EDFA (Erbium Doped Fiber Amplifier) for Fiber Optic Transmission System (광전송 시스템에서의 어븀 첨가 광섬유 증폭기에 대한 분석)

  • Kim, Ik-Sang;Ryu, Whang
    • The Journal of Engineering Research
    • /
    • v.2 no.1
    • /
    • pp.103-111
    • /
    • 1997
  • EDFA (Erbium Doped Fiber Amplifier) is widely used to compensate the loss in fiber optic transmission system. The characteristics of EDFA are investigated by analyzing the mechanism amplifying the optical power of an input with several factors to obtain the criteria for designing EDFA. When it is used in fiber optic transmission system, signal to noise characteristics in the receiver is deteriorated due to the spontaneous emission noise of EDFA. We investigate the operating conditions of EDFA to reduce BER (Bit Error Rate).

  • PDF