• Title/Summary/Keyword: Fiber-Optic

Search Result 1,082, Processing Time 0.023 seconds

Development of Peripheral Devices on the Endoscopic Surgery System (내시경 수술시스템의 주변장치 개발)

  • Lee, Young-Mook;Song, Chul-Gyu;Lee, Sang-Min;Kim, Won-Ky
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.164-166
    • /
    • 1995
  • The objectives of study are to develop a peripheral device on the endoscopic surgery system. These systems are consist of the following units. They are a color monitor of high resolution, light source, computer system and endoscopic camera with a C-mount head, irrigator, color video printer, Super VHS recorder and a system rack. The color monitor is a NTSC monitor for monitoring the image projected of the surgical section. The lightsource is necessary to irradiate the interior of a body via an optic fiber, The light projector will adapt the brightness in accordance with changing distance from the object. A miniature camera using a color CCD chip and computer system is used to capture and control an image of the surgical section[1]. The video printer is a 300 DPI resolution using thermal sublimation methods, which is developed by Samsung Electronics Co., Ltd. The specification of the endoscopic data management system is consist of storage of a captured image and pathological database of patients [2-4].

  • PDF

Synthesis and Characterization of Bifunctional Organic-Glasses Based on Diphenylhydrazone and Barbituric Acid Derivative for Photorefractive Application

  • Lee, Sang-Ho;Choi, Chil-Sung;Kim, Nak-Joong;Choi, Dong-Hoon;Park, Ki-Hong
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.12
    • /
    • pp.1793-1798
    • /
    • 2003
  • A series of amorphous molecules that possess both photoconductive and electro-optic properties was synthesized in order to investigate photorefractive properties of bifunctional organic-glasses. Diethylaminobenzaldehyde-diphenylhydrazone was covalently attached to 5-(4-diethylamino-benzylidene)-1,3-dimethylpyrimidine-2,4,6-trione through a flexible alkyl chain (3, 4, 5, 6 and 10 carbons) containing two ether linkages. The longer linkage not only lowered the glass transition temperature ($T_g$) of the molecules, but also allowed faster orientation of the chromophore. To examine the photorefractive properties, a 50 ${\mu}$m-thick film was prepared from the mixture of a bifunctional molecule, butyl benzyl phthalate, and $C_{60}$. The photoconductivity of this composite was as high as $8.01\;{\times}\;10^{-12}$ S/cm at 60 V/ ${\mu}$m, and the maximum diffraction efficiency ( ${\eta}_{max}$) of 50 ${\mu}$m-thick film was about 5% at 80 V/ ${\mu}$m.

An optical fiber construction training curriculum and an embodiment system (광통신 시공인력 실습교과과정 및 종합 실습장 조성에 관한 연구)

  • Kim, Myoung-Saeng
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.2 no.2
    • /
    • pp.22-31
    • /
    • 2003
  • The existing training courses for the optical communication construction in even a college and the university, consist of simple cutting and connecting cable technique and the subjects are splitted into parts, to which can not be grasped in a whole. Now, it is strongly demanded that the educational curriculum involves the whole process of the optical communication system construction, which includes design, supervision and up to the fusion splice connection. In this paper, the essential training elements for the optic execution worker are investigated and suggested with the appropriating solution for the experiment room.

  • PDF

A possible application of the PD detection technique using electro-optic Pockels cell with nonlinear characteristic analysis on the PD signals (포켈스 소자를 이용한 PD 신호의 검출 및 비선형적 해석에 관한 연구)

  • Lim, Y.S.;Kang, W.J.;Chang, Y.M.;Koo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1850-1852
    • /
    • 2000
  • In this paper, new Partial Discharge (PD) detection technique using Pockels cell was proposed and considerable apparent chaotic characteristics were discussed. For this purpose, PD was generated from needle-plane electrode in air and detected by optical measuring system using Pockels cell, based on Mach-Zehnder interferometer, consisting of He-Ne laser, single mode optical fiber, 50/50 beam splitter and photo detector. A qualitative analysis was carried out by drawing Return map for the normalized time series of the detected PD signals. The results are as follows:(a) Fixed points, between 0.7 and 1.0, are appeared clearly in the right upper area of the return map as the increase in the number of obtained data.(b) Considerable periodicity have been remarked even though exact period and length can not be determined.(c) The self-similarity can be also observed inasmuch as the late paths do not follow the previous ones. Accordingly, exact quantitative analysis such as embedding dimension, fractal dimension, and Lyapunov exponents should be carried out for deducing the quantitative properties regarding PD phenomena.

  • PDF

Fabrication and Characteristic Analysis of Optical Transceiver for Transmitting IMT-2000 & PCS Wireless Band (IMT-2000 & PCS 무선대역전송용 광 송수신기 제작 및 특성분석)

  • Kim, Chang-Won;Kim, Byeong-Jik;O, Yun-Je;Yang, Gwang-Jin
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.7
    • /
    • pp.24-30
    • /
    • 2000
  • In this paper, we proposed an fiber-optic transceivers based on the analog optical transmission techniques of incorporating the SCM (subcarrier multiplexing) and WDM (wavelength-division multiplexing ) method, which can be used to transmission of IMT-2000 and PCS wireless frequency band and analyzed overall those parameters related with fabrication. Especially in the impedance matching network between RF signal and LD, we proposed the method of deriving optimal performance using simulation techniques. In the frequency band of 1.7GHz∼2.25GHz, experimental data for the gain flatness and the noise floor of the optical link were also presented $\pm$1.5dB and -130dBm respectively when the link Rain was 0dB.

  • PDF

Quantification of Naproxen in Pharmaceutical Formulation using Near-Infrared Spectrometry (근적외 분광분석법을 이용한 나프록센 정제의 정량분석)

  • Kim Do Hyung;Woo Young Ah;Kim Hyo Jin
    • YAKHAK HOEJI
    • /
    • v.49 no.1
    • /
    • pp.1-5
    • /
    • 2005
  • Near-infrared (NIR) spectroscopy has been widely applied in various field, since it is nondestructive and no sample preparation is required. In this paper, NIR spectroscopy was used for the determination of naproxen in a commercial pharmaceutical preparation. NIR spectroscopy was used to determine the content of naproxen in intact naproxen tablets containing 250 mg ($65.8\%$ nominal concentration) by collecting NIR spectra in the range of $1100{\sim}1750nm$. The laboratory-made samples had $46.1{\sim}85.5\%$ nominal naproxen concentration. The measurements were made by reflection using a fiber-optic probe and calibration was carried out by partial least square regression (PLSR). Model validation was performed by randomly splitting the data set into calibration and validation data set (63 samples as a calibration data set and 42 samples as a validation data set). The developed NIR calibration gave results comparable to the known values of tablets in a laboratorial manufacturing process with standard error of calibration (SEC) and standard error of prediction (SEP) of $1.06\%\;and\;1.04\%$, respectively. The NIR method showed good accuracy and repeatability. NIR spectroscopic determination in intact tablets allowed the potential use of real time monitoring for a running production process.

Quantification of Skin Moisture in Hairless Mouse by using a Portable NIR System and a FT NIR Spectrometer (Photo Diode Array형의 휴대용 근적외 분광기와 FT 근적외 분광기를 이용한 Hairless Mouse 피부 수분 정량)

  • Suh, Eun-Jung;Woo, Young-Ah;Kim, Hyo-Jin
    • YAKHAK HOEJI
    • /
    • v.49 no.2
    • /
    • pp.115-121
    • /
    • 2005
  • In this study, the performance of a portable NIR system and a FT NIR spectrometer were compared to determine water content of hairless mouse skin. The stratum corneum parts wer e separated from the epidermal tissues by trypsin solution. NIR diffuse reflectance spectra of hairless mouse skin were acquired using a fiber optic probe. In the near infrared, water molecules show two clear absorption bands at 1450 nm from first overtone of O-H stretching and 1940 nm from the combination involving O-H stretching and O-H deformation. It was found that the variations of O-H absorption band according to water content. Partial least squares regression (PLSR) was applied to develop a calibration model. The PLS model showed a good correlation between NIR predicted value and the absolute water content of separated hairless mouse skin, in vitro. For both the portable and the FT NIR spectrometer, These studies showed the possibility of a rapid and nondestructive skin moisture measurement using NIR spectroscopy. The portable NIR spectrometer with a photodiode arrays-microsensor could be more rapidly applied for the determination of water content with comparable accuracy with the performance of a FT spectrometer .

Linearity Analysis and Calibration of a Cable-Conduit Bend Sensor (케이블 컨듀잇 굽힘 센서의 선형 특성 분석 및 켈리브레이션)

  • Jeong, Useok;Cho, Kyu-Jin
    • The Journal of Korea Robotics Society
    • /
    • v.12 no.1
    • /
    • pp.26-32
    • /
    • 2017
  • Previous shape sensors including bend sensors and optic fiber based sensors are widely used in various applications including goniometer and surgical robots. But theses sensors have large nonlinearity, limited in the range of sensing curvature, and sometimes are expensive. This study suggests a new concept of bend sensor using cable-conduit which consists of the outer sheath and the inner wire. The outer sheath is made of helical coil whose length of the central line changes as the sheath bends. This length change of the central line can be measured with the length change of the inner cable. The modeling and the experimental results show that the output signal of the proposed sensor is linearly related with the bend angle of the sheath with root mean square error of 5.3% of $450^{\circ}$ sensing range. Also the polynomial calibration of the sensor can decrease the root mean square error to 2.1% of the full sensing range.

A Study of An Initial Alignment Method of Underwater Vehicle Dropped from Aircraft (항공기에서 투하되는 수중운동체의 초기정렬기법 연구)

  • 류동기;김삼수
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.21-29
    • /
    • 2003
  • The Strap Down Inertial Measurement Unit(SDIMU) is recently used for the sensor package of the modern underwater vehicles such as torpedoes and unmanned underwater-vehicles. For using SDIMU, an initial alignment must be carried out before the fire or navigation stage. The general initial alignment methods require that a mother vehicle Is a stationary condition or the Inertial Navigation System(INS) of vehicle is received the specific of data navigation from the mother vehicle. But an underwater vehicle dropped from aircraft is hard to satisfy above both necessary conditions of the general initial alignment. So, we suggest a new strap down initial alignment method of an underwater vehicle dropped from aircraft without using any aided sensors. The highlight point of this method is that a period of initial alignment is not before the fire but during running stage to fix alignment error. And we verify it by analyzing various data of S/W simulations, Hardware In the Loop Simulation(HILS) tests and sea trials.

Design and Construction of Laser Range Finder for Many Purposes (다목적 레이저 거리측정기(Laser Range Finder) 설계 및 개발)

  • Lee, Jae-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.7
    • /
    • pp.3214-3219
    • /
    • 2011
  • Nowadays, we live in the age of highly developed information technology. The information industry is growing rapidly and it is making remarkable changes in our life. Among the information technologies, laser range finder can be used to measure distance in difficult environment. In this paper, we have designed and constructed the laser range finder for many purposes such as industry or leisure in difficult environment. Using the proposed laser range finder enables us to measure distance easily using timing discriminator between transmitter and receiver for industry or leisure.