• Title/Summary/Keyword: Fiber optical sensor

Search Result 727, Processing Time 0.027 seconds

Development of intrusion detection technique using fiber optic ROTDR sensor (광섬유 ROTDR 센서를 이용한 침입 탐지기법의 개발)

  • Baik, Se-Jong;Kwon, Il-Bum;Chung, Chul;Yu, Jae-Wang
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.209-217
    • /
    • 2002
  • The developing of buried fiber optic sensor with high sensitivity and broad-area detecting intruders is carried out using fiber optic ROTDR(Rayleigh Optical Time Domain Reflectometry). The sensing part was designed to be able to broad-area detect intrusion effect per optical fiber length under ground. The bending light losses in optical fibers are investigated by commercial mini ROTDR with wavelength $1.55{\mu}m$, distance range 5km, pulse width 20ns, SNR=5.7. The sensing fibers are selected as the common telecommunication fibers are the 1.5mm, 3.5 mm outer diameter, 4km each length fiber products. Experiments were investigate the characteristics of signal sensitivity according to applied intrusion weight. The relation between the applied weight and the bending loss was almost linear, and broad-area detect intrusion effects are the 2m resolution and $1.3m^2$ per optical fiber length respectively. The light loss by the applied weight on fiber was 0.17 dB/kg. that the sensitivity of the optical fiber sensor was sufficient to detect intruders passing over the buried optical fiber.

Fiber-optic humidity sensor system for the monitoring and detection of coolant leakage in nuclear power plants

  • Kim, Hye Jin;Shin, Hyun Young;Pyeon, Cheol Ho;Kim, Sin;Lee, Bongsoo
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1689-1696
    • /
    • 2020
  • In this study, we developed a fiber-optic humidity sensor (FOHS) system for the monitoring and detection of coolant leakage in nuclear power plants. The FOHS system includes an FOHS, a spectrometer, a halogen white-light source, and a Y-coupler. The FOHS is composed of a humidity-sensing material, a metal tube, a multi-mode plastic optical fiber, and a subminiature version A (SMA) fiber-optic connector. The humidity-sensing material is synthesized from a mixture of polyvinylidene fluoride (PVDF) in dimethyl sulfoxide (DMSO) and hydroxyethyl cellulose (HEC) in distilled water. We measured the optical intensity of the light signals reflected from the FOHS placed inside the humidity chamber with relative humidity (RH) variation from 40 to 95%. We found that the optical intensity of the sensing probe increased linearly with the RH. The reversibility and reproducibility of the FOHS were also evaluated.

Measurements of relative depth dose rates for a brachytherapy Ir-192 sourceusing an organic scintillator fiber-optic radiation sensor (유기 섬광체-광섬유 방사선 센서를 이용한 근접 방사선원 Ir-192의 상대 깊이 선량율 측정)

  • Shin, Sang-Hun;Jang, Kyoung-Won;Cho, Dong-Hyun;Yoo, Wook-Jae;Seo, Jeong-Ki;Lee, Bong-Soo;Moon, Joo-Hyun;Kim, Sin;Park, Byung-Gi
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.462-469
    • /
    • 2008
  • In this study, we have fabricated a fiber-optic radiation sensor using an organic scintillator and plastic optical fiber for brachytherapy dosimetry. Also, we have measured relative depth dose rates of Ir-192 source using a fiber-optic sensor and compared them with the results obtained using a conventional EBT film. Cerenkov lights which can be a noise in measuring scintillating light with a fiber-optic sensor are measured and eliminated by using of a background optical fiber. It is expected that a fiber-optic radiation sensor can be used in brachytherapy dosimetry due to its advantages such as a low cost, simple usage and a small volume.

Absolute Strain Measurement Using Fiber Bragg Grating Sensor (광섬유 브래그 격자 센서를 이용한 절대 변형률 측정)

  • ;Lou-shuang
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.416-420
    • /
    • 2002
  • This Paper describes a matched-filter type strain sensor system using optical fiber Bragg grating (FBG) sensor. Matched-filter type uses another wavelength-matched FBG filter to track wavelength shift in the FBG sensor. Filter FBG is attached on a fiber stretcher and stretched by PZT actuator. To overcome the nonlinearity and hysteresis of the PZT actuator that degrades system accuracy, a string resonator which can measure an absolute strain is employed. And the effect of vibration modes on string resonator is investigated particularly regarding its sensitivity and stability.

  • PDF

Earthquake Movement Measurement of the Top of Bridge Pier Using Fiber Optic Smart Structure Concept (광섬유 스마트 구조물의 개념을 이용한 교량상부 내진거동 측정)

  • Kim Ki-Soo;Han In-Dong
    • Composites Research
    • /
    • v.19 no.3
    • /
    • pp.43-49
    • /
    • 2006
  • In this paper, a long gauge Fiber Bragg Grating (FBG) sensor system is described and long gauge FBGs are well-suited for measuring the upper parts of the bridge piers under the extremely severe movement conditions. In the experiments, we used more than 30m long FBG sensors to measure the movement of top part of the bridge piers which are separated from the main bridge by cutting the decks. With the actuator, the deck and girders were pushed and released. We checked the movement of the top of the pier while releasing the pressure of the actuator with the long gauge fiber sensor. In order to measure the movement of the upper part of the pier, the reference point must be outside of the pier. Using the optical fiber sensors, one end of the sensor is attached to the top of the pier and the other end is attached to the bottom of the next pier. The fiber sensors showed good response to the release loading and we could calculate the movement of the top part of the pear.

Monitoring of Beam-column Joint Using Optical Fiber Sensors (광섬유센서를 이용한 Beam-column 조인트의 하중에 따른 변위 계측)

  • Kim, Ki-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.1 s.94
    • /
    • pp.3-11
    • /
    • 2005
  • For monitoring of the civil and building structure, optical fiber sensors are very convenient. The fiber sensors are very small and do not disturb the structural properties. They also have several merits such as electro-magnetic immunity, long signal transmission, good accuracy and multiplexibility in one sensor line. Strain measurement technologies with fiber optic sensors have been investigated as a part of smart structure. In this paper, we investigated the possibilities of fiber optic sensor application to the monitoring of beam-column joints of structures. We expect that the fiber optic sensors replace electrical strain gauges. The commercial electric strain gauges show good stability and dominate the strain measurement market. However, they lack durability and long term stability for continuous monitoring of the structures. In order to apply the strain gauges, we only have to attach them to the surfaces of the structures. In this paper, we investigate the possibility of using fiber optic Bragg grating sensors to joint structure. The sensors show nice response to the structural behavior of the joint.

Length Effects of Hetero-Core Optical Biosensor based on Evanescent Field Absorption

  • Shim, Joon-Hwon;Chan, Joo-Kwong;Sohn, Kyung-Rak
    • Journal of Navigation and Port Research
    • /
    • v.32 no.9
    • /
    • pp.723-727
    • /
    • 2008
  • Sensing performances of evanescent field absorption (EFA) hetero-core fiber sensor has been presented based on EFA by changing the length and the core diameter of the single mode fiber. Experimental results have demonstrated a good feature in their relationship between the length and the core diameter of the single mode fiber. The sensor consists of 2 fiber optics which have the same cladding diameter of $125{\mu}m$ However one fiber optic used is single mode and has varying core diameter ranging from 3.3 to $5.6{\mu}m$. The other fiber is multimode type and has a thicker fixed core diameter of $62.5{\mu}m$. The 2 fiber optics are thermally spliced together. Experiments conducted to measure the resonance wavelength were carried out over a range of refractive index, to find the optimum sensing length Experiments show that core diameter of the single mode fiber and sensing length offects the linearity and sensitivity.

Monitoring of Beam-Column Joint Using Optical Fiber Sensors (광섬유센서를 이용한 Beam-column 조인트의 하중에 따른 변위 계측)

  • 김기수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.595-601
    • /
    • 2003
  • For monitoring of the civil and building structure, optical fiber sensors are very convenient. The fiber sensors are very small and do not disturb the structural properties. They also have several merits such as electro-magnetic immunity, long signal transmission, good accuracy and multiplicity of one sensor line. Strain measurement technologies with fiber optic sensors have been investigated as a part of smart structure. In this paper, we investigated the possibilities of fiber optic sensor application to the monitoring of beam-column joints of structures. We expect that the fiber optic sensors replace electrical strain gauges. The commercial electric strain gauges show good stability und dominate tile strain measurement market. However, they lack durability and long term stability for continuous monitoring of the structures. In order to apply the strain gauges, we only have to attach them to the surfaces of the structures. In this paper, we investigate the possibility of using fiber optic Bragg grating sensors to joint structure. The sensors show nice response to the structural behavior of the joint.

  • PDF

The measurement of the internal strain of a concrete specimen using optical fiber interferometric sensors (광섬유 간섭계 센서를 이용한 콘크리트 구조물의 내부 스트레인 측정)

  • Lee, Kyung-Jin;Park, Jae-Hee;Kang, Shin-Won
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.6
    • /
    • pp.304-309
    • /
    • 2001
  • A Fiber optic strain sensor for the measurement of the internal strain of a concrete specimen was developed. This sensor was a 11 mm Fiber-optic Fabry-Perot interferometer attached inside a stainless steel pipe of 2 mm diameter. The fabricated strain sensors were embedded in a reinforced concrete structure of $100{\times}100{\times}500\;mm^3$ size and were measured the internal strain of a concrete structure when the external pressure was applied to the structure. For a field application, the strain sensors were attached on the bottom of a real bridge and dynamic loading test were executed. In the test, they showed good sensitivity as a deformation sensor and capability of remote monitoring.

  • PDF