• 제목/요약/키워드: Fiber filtration

검색결과 152건 처리시간 0.04초

여과-Plasma 공정을 이용한 Ralstonia Solanacearum 불활성화 (Inactivation of Ralstonia Solanacearum using Filtration-Plasma Process)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제23권6호
    • /
    • pp.1165-1173
    • /
    • 2014
  • For the field application of dielectric barrier discharge plasma reactor in nutrient solution culture, a filtration-DBD (dielectric barrier discharge) plasma reactor was investigated for the Ralstonia solanacearum which causes bacterial wilt in aquiculture. The filtration-DBD plasma reactor system of this study was consisted of filter, plasma reactor, reservoir. The DBD plasma reactor consisted of a quartz dielectric tube, discharge electrode (inner) and ground electrode (outer). The experimental results showed that the inactivation of R. solanacearum with filter media type in filter reactor ranked in the following order: anthracite > fiber ball > sand > ceramic ball > quartz ceramic. In filtration + plasma process, disinfection effect with the voltage was found to small. In disinfection time of 120 minutes, residual R. solanacearum concentration was 1.17 log (15 CFU/mL). When the continuous disinfection time was 120 minute, disinfection effect was thought to keep the four days. In sporadic operation mode of 30 minutes disinfection - 24 hours break, residual R. solanacearum concentration after five days was 0.3 log (2 CFU/mL). It is considered that most of R. solanacearum has been inactivated substantially.

Development of photocatalytic PVA/$TiO_2$ nanofiber membrane by electrospinning and its application for Air Filtration

  • Linh, Nguyen Thuy Ba;Lee, Byong-Taek
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2010년도 춘계학술발표대회
    • /
    • pp.38.1-38.1
    • /
    • 2010
  • Nanofibers have a large potential in air filtration applications. In this work, we have developed a photocatalytic polyvinyl alcohol PVA/$TiO_2$ nanofibers membrane for the treatment of air filtration by using electrospinning method. PVA were electrospun into nanofibrous membranes and $TiO_2$ nanoparticles were loaded in PVA nanofibers in various contents from 10% (w/w) to 50% (w/w). The UV-Vis spectra were conducted for testing the existence of $TiO_2$ nanoparticles in PVA fibers. SEM analysis indicated that $TiO_2$ nanoparticles were loaded on the surface of PVA fibers and dispersed linearly along the fiber direction, which originated from the effect of polarization and orientation caused by high electric field. X-ray diffraction (XRD) was used to determine the crystalline of the membrane. Tensile strength was measured to evaluate the physical properties of the membrane. Therefore, our work suggested that PVA/$TiO_2$ nanofiber membrane has a potential application in air filtration area.

  • PDF

여과-투과에 대한 실험적 분석: 여과매체의 종류, 여과매체의 매수, 여과압력의 영향 (Experimental Analysis on Filtration-Permeation: Influence of the Type and Sheets of Filter Media, and Filtration Pressure)

  • 임성삼;송연민
    • Korean Chemical Engineering Research
    • /
    • 제50권2호
    • /
    • pp.317-327
    • /
    • 2012
  • 케이크 여과와 고액분리에서 가장 중요한 지표인 케이크 평균 비저항을 결정하는 방법으로 여과실험을 사용하고 있으나 침전 등의 영향으로 정확한 값을 측정하기 어렵다. 이 연구에서는 조금 더 안정된 방법으로 여과 후 형성된 케이크에 입자제거수를 투과시켜 평균 비저항을 측정하는 여과-투과 실험을 제안한다. 탄산칼슘 1 wt% 현탁액을 사용하여 여과-투과 실험을 8종의 여과매체에 대하여 여과매체 1장과 3장, 압력 0.5 기압과 0.2 기압의 조건에서 각 조건 당 3~5회씩 동일한 실험을 수행하였다. 그 결과 여과 후 투과에서도 안정된 투과 속도가 측정됨을 확인하였고, 이를 바탕으로 Ruth의 공식을 분석하여 투과기간의 특징을 구명(究明) 하고 여과기간에 발생하는 침전의 영향을 분석하였다. 그 다음, 여과매체 3종을 선택하여 여과와 투과에서의 케이크 평균 비저항값으로 일원배치법에 의한 분석을 하였다. 분석결과 여과에 의해서는 0.5 기압과 0.2 기압의 케이크 평균 비저항값이 구분되지 않으나, 투과에 의해서는 충분히 구분되었다. 또한 투과기간의 케이크 평균 비저항값들이 여과기간의 그것에 비해 매우 좁은 분포를 가지는 것을 확인했다. 여러 여과매체의 여과 실험결과를 분석하여, 여과매체 저항을 현재의 방법으로 측정하는 것은 큰 의미가 없음을 밝혔고, 유리섬유 여과-투과 실험 결과로 낮은 압력에서 입자의 여과매체 이동 가능성에 대한 분석을 수행했다.

선박 디젤엔진 배출 미세먼지 저감을 위한 정전 여과 매연 집진기 개발에 관한 연구 (An Electrostatic Diesel Particulate Filtration System for Removal of Fine Particulate Matters from Marine Diesel Engines)

  • 김영훈;이건희;홍기정;김용진;김학준;박인용;한방우
    • 한국입자에어로졸학회지
    • /
    • 제19권4호
    • /
    • pp.101-110
    • /
    • 2023
  • In order to reduce particulate matters (PM) from marine diesel engines, we developed novel electrostatic diesel particulate matter filtration system. Electrostatic diesel particulate filtration (DPF) system consists of electrostatic charger and filtration part. The electrostatic charger and filtration part are composed of a metal discharge electrode and a metal fiber filter (porosity: 68.1-86.1%), respectively. In the electrostatic charger part, diesel soot particles are reduced by electrostatic force. The filtration part after electrostatic charger part reduces diesel soot particles through inertial and diffusion forces. The filtration efficiency of electrostatic DPF system was examined through the experiments using engine dynamometer system (300 kW) and ship (200 kW). The PM reduction efficiencies due to inertial and electrostatic forces showed about 70-75% and 80-90%, respectively, according to the RPM of the engine. The differential pressure of the electrostatic DPF system applied to the ship was about 1-9 mbar, which was less than the allowable differential pressure for ship engines in South Korea (100 mbar). The results show that the electrostatic DPF system is suitable for application to the PM reduction emitted from ships.

Modification of polyethersulfone hollow fiber membrane with different polymeric additives

  • Arahman, Nasrul;Mulyati, Sri;Lubis, Mirna Rahmah;Razi, Fachrul;Takagi, Ryosuke;Matsuyama, Hideto
    • Membrane and Water Treatment
    • /
    • 제7권4호
    • /
    • pp.355-365
    • /
    • 2016
  • The improvement of fouling resistance of porous polymeric membrane is one of the most important targets in membrane preparation for water purification in many process like wastewater treatment. Membranes can be modified by various techniques, including the treatment of polymer material, blending of hydrophilic polymer into polymer solution, and post treatment of fabricated membrane. This research proposed the modifications of morphology and surface property of hydrophobic membrane by blending polyethersulfone (PES) with three polymeric additives, polyvinylpyrrolidone (PVP), Pluronic F127 (Plu), and Tetronic 1307 (Tet). PES hollow fiber membranes were fabricated via dry-wet spinning process by using a spinneret with inner and outer diameter of 0.7 and 1.0 mm, respectively. The morphology changes of PES blend membrane by those additives, as well as the change of performance in ultrafiltration module were comparatively observed. The surface structure of membranes was characterized by atomic force microscopy and Fourier transform infra red spectroscopy. The cross section morphology of PES blend hollow fiber membranes was investigated by scanning electron microscopy. The results showed that all polymeric additives blended in this system affected to improve the performances of PES membrane. The ultra-filtration experiment confirmed that PES-PVP membrane showed the best performance among the three membranes on the basis of filtration stability.

그물망 압착식 섬유여과장치를 이용한 물 재이용 시스템 개발 (Development of Water Reusing System by Using Net3FM (Net Fit Fiber Filter Module))

  • 김정숙;김미란;조명찬;장정국
    • 한국환경과학회지
    • /
    • 제21권12호
    • /
    • pp.1523-1528
    • /
    • 2012
  • This study was carried out to develop pilot plant Net3FM(Net Fit Fiber Filter Module) system and to suggest optimum operating condition for municipal wastewater reuse. SS concentration of biologically treated sewage effluent was reduced from 1.5~5.4mg/L to 0.4~1.0mg/L without coagulant injection in Net3FM system, and the SS removal efficiency was average 84.7%. And also, the removal efficiencies of COD and T-P were decreased slightly due to the SS removal by filtration. Coagulation-Filtration test was conducted to enhance the removal efficiencies of SS and T-P. The optimum dosage of coagulant was injected automatically by auto-controlling system, which is controlled by detecting value of turbidity of secondary sewage effluent. SS, COD and T-P concentrations in filtrated effluent were 0.21~0.57, 1.6~6.2 and 0.137~0.392mg/L with coagulant injection by in-line mixer in Net3FM system, respectively. The removal efficiencies of SS and T-P were highly increased to 92.8% and 89.8%, respectively. It was due to the combined the processes of coagulation and filtration. Net3FM system was evaluated that the removal efficiency of pollutants in secondary sewage effluent and the utilization potential as reclaimed water technology were very high.

중공사 나노여과막에 의한 방향족 농약의 제거에서 흡착의 영향 (Effect of Adsorption on the Removal of Aromatic Pesticides by Hollow Fiber NF Membrane)

  • 정용준
    • 한국환경과학회지
    • /
    • 제25권3호
    • /
    • pp.395-403
    • /
    • 2016
  • This study examined the adsorption effect of aromatic pesticides by hollow fiber NF membrane on rejection and removal properties. Batch type adsorption test and hollow fiber NF membrane filtration were conducted with 5 different kinds of aromatic pesticides. 3 to 15 days were required to reach the equilibrium concentration and $0.3181{\sim}0.8094{\mu}g/cm^2$ were adsorbed to hollow fiber NF membrane. Since 5 hours of separation test were too short to keep steady state for permeate due to the repetition of sorption and desorption, longer times were required to evaluate the rejection performance of NF membrane. Sorption and desorption were confirmed by the separation test equipped with membrane and without membrane. Adsorption contribution of aromatic pesticides to hollow fiber membranes were shown to be ranged from 16.1% to 36.3% and indicated the difference considering sorption effect.

Assessment of Drainage Properties of PBDs(Prefabricated Board Drains) for Soft Soil Reinforcement

  • Jeon, Han-Yong;Kim, Hong-Gwan;Chang, Yong-Chai;Chung, Chin-Gyo
    • 한국섬유공학회:학술대회논문집
    • /
    • 한국섬유공학회 2003년도 The Korea-Japan Joint Symposium
    • /
    • pp.105-105
    • /
    • 2003
  • Theoretical studies have been performed for drainage and filtration characteristics, low consolidation rate of sandmat and prefabricated horizontal and vertical drain. Discussion on quality control and methodology, cost analysis for sandmat and prefabricated horizontal drains were performed.

  • PDF

폴리설폰 중공사막 혈액여과기의 설계 및 여과성능 (Design and Filtration Performance of Polysulfone Hollow Fiber Membrane Hemofilter)

  • 김재진;박진용
    • 대한의용생체공학회:의공학회지
    • /
    • 제14권3호
    • /
    • pp.227-234
    • /
    • 1993
  • Hemofilter was optimally designed and manufactured using polysulfone hollow fiber mem- brane with surface area of 0.6mE Molecular weight cut-off of the hemofilter was measured with polyethylene glycol and dextran aqueous solutions of various molecular weights and it was ranged from 9,500 to 38,900. Ultrafiltration rates were measured with pure water in a static system and flowing system. The clearance of urea, creatinlne, and vitamine BIB were measured using aqueous solutions.

  • PDF