• Title/Summary/Keyword: Fiber filter

Search Result 523, Processing Time 0.037 seconds

Preparation of Metal/Ceramic Composite Ultrafiltration Hollow Fiber Membranes (금속/세라믹 중공사형 복합 한외여과막의 제조)

  • Kim, In-Chul;Jeong, Bo-Reum;Lee, Dong-Wook;Park, Joo-Young;Kwon, Ja-Young;Lee, Kew-Ho
    • Membrane Journal
    • /
    • v.19 no.1
    • /
    • pp.47-53
    • /
    • 2009
  • The aim of this paper is to prepare metal/ceramic composite ultrafiltration membranes by coating inorganic particles on a metallic hollow fiber filter. The diameter and the pore size of the filter was 2.0 mm and $2{\sim}8{\mu}m$. The metal/ceramic composite ultrafiltration membranes were obtained by a coating process of silica and titania sols on top of the metallic filter. For this purpose the method of fast freeze drying and dip-coating were used. It was found that the pore size of the membrane was about 50 nm from SEM and PMI characterization. The pore size was controlled by changing the size of the particles, sintering period and temperature.

Properties of the Electrolyte Separators for Thermal Batteries Using SiOC Mat (SiOC 매트(Mat)를 이용한 열전지용 전해질 격리판 제조 및 특성)

  • Lim, Kyoung-Hoon;Cho, Kwang-Youn;Riu, Doh-Hyung;Shin, Dong-Geun;Jin, Eun-Ju;Kim, Hyoun-Ee;Cheong, Hae-Won;Lee, Hong-Lim
    • Journal of the Korean Ceramic Society
    • /
    • v.46 no.6
    • /
    • pp.648-652
    • /
    • 2009
  • Ceramic fiber separator is the promising material for thermal battery system because it reduces the production cost and offers the potential to a new application compared to a pellet type electrolyte. The electrolyte separator for thermal battery should be easily handled and loaded a large amount of the molten lithium salt. Ceramic fibers were used as an electrolyte separator and the lithium based molten salts were infiltrated into the ceramic filters. Leakage of molten salt (several lithium salts) leads to short-circuit during the thermal battery operation. In this study, a uniform and fine SiOC mat with fibers ranging from 1 to 3 ${\mu}m$ was obtained by electrospinning of polycarbosilane and pyrolysis. The optimum spinning conditions for obtaining fine diameters of SiOC fiber were controlled by the solution composition and concentration, applied voltage and spinning rate, release rate by porosity. The pore structures of the ceramic filter and the melting properties of the lithium salts affected to the electrolyte loading and leakage. The importance of the fiber size and porosity and their control was discussed and the mechanical properties were also discussed.

Evaluation of Turbidity Removal Efficiency on under Flow Water by Pore Controllable Fiber Filtration (공극제어형 섬유사 여과기를 이용한 복류수의 탁도 제거효율 평가)

  • Kim, Jeong-Hyun;Bae, Chul-Ho;Kim, Chung-Hwan;Park, No-Suk;Lee, Sun-Ju;Anh, Hyo-Won;Huh, Hyun-Chul
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.2
    • /
    • pp.135-143
    • /
    • 2005
  • It was evaluated that the effect of turbidity removal by Pore Controllable Fiber Filter(PCF) installed in NS(Naksang) small water treatmant plant(system) using under flow water as raw water in the study. The results of the study are as the followings. Firstly, the removal efficiency of turbidity by PCF without coagulation(in operation mode not using coagulants) was mostly below 20 percent. On the other hand, when operation using proper coagulants, that of turbidity was mostly over 80 percent. Secondly, slow sand filtration after PCF, total turbidity removal efficiency of final treated water was 84.3 percent, and the contribution by PCF was 57.1 percent and that of slow sand filtration was 27.7 percent. Therefore the introduction of PCF as pre-treatment process would be helpful to reduce the loading of high turbidity of slow sand filtration. Thirdly, the results of particle counter measurements showed that when operated PCF with coagulants, fine flocs captured or adsorbed at the pore of PCF were flow out into the effluents from 120 minutes after backwashing because of the increase of headloss of PCF. Therefore the decision of backwashing time should made consideration into the outflow of fine flocs from PCF. Fourth, coagulant dosages on PCF at the same turbidity was largely variable because of the effect of the raw water characteristics and the turbidity increase velocity at rainy days, therefore flexible coagulant dosages should be considered rather than fixed coagulant dosage by the influent jar-test result.

A Study on the Tank Liquid-Level Monitoring Sensor Systems for Large Scaled Vessels (대형선박의 액체 탱크용 수위 모니터링 센서 시스템 연구)

  • Sohn, Kyung-Rak;Kim, Jin-Wook;Cho, Seok-Je;Shim, Joon-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.330-335
    • /
    • 2009
  • A fiber-optic liquid level sensor based on bending cantilever beam has been proposed. A fiber Bragg grating(FBG) embedded in the cantilever beam is used to sensing elements. The basic concept is elongation and constriction of the FBG corresponding to the liquid level variation. The best FBG position on the cantilever for obtaining the high sensitivity was 4 cm from the fixing point. When the liquid level moves up and down vertically, the Bragg wavelength is linearly shifted. But, the wavelength sensitivity of the FBG installed on the upper side of cantilever was four times better than that of the FBG equipped in the lateral side due to the difference of unit strain applied to the FBG. Intensity demodulation using the low-cost edge filter is used to interrogate the Bragg wavelength through converting the wavelength signals into the optical intensity ones. Experiment results show that the electrical output is exponentially proportional to the liquid level. But, it should be overcome for applying to the ships.

Sensor Mat using POF for Medical Application (의료용 플라스틱 광섬유 센서 매트)

  • Choi, Kyoo-Nam
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.4 s.316
    • /
    • pp.74-78
    • /
    • 2007
  • Novel concept of sensor mat and its signal processing method is proposed for patient monitoring in medical application. Proposed sensor mat structure has sensing inner layer which has cross-linked arrangement using plastic optical fiber(POF). Large core diameter of plastic optical fiber behaved as band pass filter by averaging the noise component caused by unwanted environmental factors. Signal processor followed by sensor output added noise immune performance by filtering out unwanted component. Fail-proof patient breath monitoring scheme was realized by using intelligent decision algorithm. Unlike the conventional approach by using mechanical sensor, which have high sensitivity both to signal and to environmental noise, our approach provided reliable breath motion detection.

Theoretical analysis improved cavitity design of a 10 GHz harmonically mode-locked Er-doped fiber laser (10GHz로 고조모드록킹된 고리형 어븀첨가 광섬유 레이저의 이론적 해석 및 향상된 공진기 설계)

  • 이유승
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.5
    • /
    • pp.353-359
    • /
    • 2000
  • A harmonically mode-locked fiber ring laser cavlty was theoretically analyzed. The measured charactenstlcs of a 10 GHz erbium-doped fiber ring laser were used as a basis of the theoretical analysis. From the nonlinear Schroedinger equation of an actively mode-locked erblUm-doped fiber laser. the effects of the components inside the laser cavity have been analyzed includmg nonlinear effects from group-velocity dispersion (GVD) and self-phase modulation (SPM). Usmg the analysls. we have designed a laser cavity with minimum pulsewidth and chirp by changing the intracavity optical intensity and the bandwidth of the filter. In the new design, the chirp i, reduced by 2 times and the pulsewidth by 2A times. compared to the laser used in the experiment. iment.

  • PDF

SNR Improvement in A Wireless Optical Differential Detector Using Plastic Fibers (플라스틱 광섬유를 이용한 무선광 차동검출기의 신호대잡음비 개선)

  • Lee Seong-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.4 s.95
    • /
    • pp.410-417
    • /
    • 2005
  • In this paper, optical noise is reduced by a differential detector with a plastic optical fiber bundle in a wireless optical interconnection. A plastic optical fiber bundle divides the received optical signal equally and connects it to two photodiodes. In this configuration two photodiodes effectively detect the optical signal at one point, and the output voltage variation due to the abrupt change of optical noise distribution in space disappears. The signal to noise ratio in a differential detector with a fiber bundle was improved to be $10\;\cal{dB}$ higher than in a single photodiode with an optical filter.

A Study on the Antimicrobial Activity of Microcystis aeruginosa by Redox Reaction of Cu-Zn Alloy Metal Fiber (구리-아연 합금사의 산화-환원 반응을 통한 Microcystis aeruginosa의 사멸 특성에 관한 연구)

  • Song, Ju-Yeong;Kim, Hee-Seon;Lee, Sang-Ho;Kim, Jong-Hwa;Park, Keun-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.168-174
    • /
    • 2008
  • This study is focused on the antimicrobial activity of cyanobacteria Microcystis aeruginosa by the reduction and oxidation reaction of copper and zinc alloy metal fiber filter. Cu/Zn ion is easily makes radicals with molecular hydroperoxide. Especially, hydroperoxide radical shows strong toxicity to the strains. Plasma membrane causes conformational change when hydroperoxide radical binds to plasma membrane. Elution of copper ion from copper and zinc alloy metal fiber is detected in the cyanobacteria solution as 0.5 ppm, and that of zinc ion is 0 ppm respectively. Zinc ion is figured to form a hydroxide in the cyanobacteria solution and precipitated to form a sludge. The concentration of chlorophyll-a in the cyanobacteria solution was proved to be the index of antimicrobial level of Microcystis aeruginosa.

Characteristics of the Natural Fiber Drain Board for Environmentally Friendly Soil Improvement Method (자연친화형 연약지반개량공법을 위한 천연섬유배수재의 특성 연구)

  • Kim, Ju Hyong;Cho, Sam-Deok;Jang, Yeon-Su;Kim, Soo Sam
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.9 no.1
    • /
    • pp.1-13
    • /
    • 2006
  • The recent environmental protection issue has diminished the supply of sand for soft ground improvements so much that the prices of sand have shown a sudden rise. Plastic material is one of substitutes for sand material, but plastic is nonperishable and doubtable if it has potential environmental hormone disrupting substances. Moderate-priced natural fiber drain board made with coconut coir and jute filter are in the spotlight recently as an alternative material for sand and plastic drain board etc. Natural fiber drain has not only competitive price but also a characteristic of assimilation into the soils after finishing of its own function. Discharge capacity of the fiber drain board evaluated by triaxial type discharge capacity test was relatively lower than that of plastic drain board. Nevertheless, settlement and pore pressure dissipation behaviors of the fiber drain board and the plastic drain board which were installed in the clayey soil during the composite discharge capacity test were almost similar. It was also found that biodegradation of the fiber drain board was in progress until 18 month after installation in the clayey soil, but they had still enough engineering properties to use at field.

Bleed Test for Mortar using Pressure Filter (가압 거름방법에 의한 모르타르의 블리딩 측정 방법)

  • Shin, Kyung-Joon;Choi, Seul-Woo;Choi, Sung;Lee, Kwang-Myong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.809-812
    • /
    • 2008
  • Bleed test methods currently being specified in KS, ASTM and BS are the methods to read the height of bleed water and volume changes of mortar poured into transparent cylinder. Time for measuring of bleed are specified as 3, 20 hours in KS specification, while bleed is measured at 3 hour and change of volume is measured at 24 hour in ASTM and BS specification. Like these, bleed test takes a lot of time to conduct. Another method to measure the bleed is the pressure filter test. This method predict the bleed by measuring the passed water through the fiber glass filter under pressure. This pressure filter test developed by Schupack in 1971 has an advantage in predicting the bleed in shorter time. However, data correlating the pressure filter test results with amount of bleed are limited. Therefore, this study aims at verifying the availability of pressure filter test as a method to predict the bleed and deriving the relation between this test results and bleed.

  • PDF