• Title/Summary/Keyword: Fiber distribution

Search Result 985, Processing Time 0.029 seconds

Evaluation of the Fiber Separation Method and Differences in the Storage Root Fiber Content among Sweetpotato (Ipomoea batatas L.) Varieties (고구마 괴근의 섬유질 분리 조건 탐색 및 품종별 섬유질 함량 차이)

  • Won Park;Im been Lee;Mi Nam Chung;Hyeong-Un Lee;Tae Hwa Kim;Kyo Hwui Lee;Sang Sik Nam
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.68 no.1
    • /
    • pp.20-26
    • /
    • 2023
  • Fiber content in the storage roots of sweetpotato varies between different varieties. For examples, the high fiber content of certain types has a poor texture when steamed or roasted. This study was conducted to evaluate the optimal sieve mesh size for separating fibers, the chemical composition of fibers and differences in fiber content among different varieties. We found that the separated fiber content (dry weight) of mashed and steamed sweetpotato was higher after washing three times (143.3 mg/100 g) compared with that washed five times (128.4 mg/100 g). The Hogammi variety remained 85.9% of total fiber content at 10 mesh (2,000 ㎛) and 9.6% of total fiber content at 30 mesh (600 ㎛), and Jinyulmi remained 74.9 and 16.7% of total fiber content , respectively. Therefore, a 30 mesh sieve was considered the most suitable for fiber separation. Among the 10 studied cultivars, Jinhongmi showed the lowest amount of fiber (24.8 mg/100 g) and Hogammi had the highest amount (111.4 mg/100 g), which was 4.5 times larger than that of Jinhongmi. Cellulose, hemicellulose and lignin content of separated fibers showed no difference between the viscous-type Hogammi and powdery-type Jinyulmi varieties, with averages of 32.5, 22.3 and 29.6%, respectively. Correlation results using the Image J program showed a significant correlation between the distribution of the stained area and the fiber content (R = 0.74, p < 0.05). Staining distribution differed among varieties, suggesting that a simple fiber content test could be performed using the staining method on raw sweetpotato. These results provide useful information to help inform farmers on the fiber content of different sweetpotato varieties.

Distribution Automation System in KEPCO (한전의 배전자동화)

  • 장영주
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.7-10
    • /
    • 2001
  • Distribution Automation System (DAS) has been designed and implemented for feeder automation using the Paircable, Optical-Fiber, Wireless, TRS as a communication media. KEPCO has been constructed DAS since 1984. We have two types of DAS. one is large-scale DAS for major city in korea, the other is small-scale DAS (or the rest of major city. we are plan to finish small-scale DAS by end of 2001.

  • PDF

A Study on Temperature Distributions of Thermoset Composite in FPS Process (FPS 공정에 의한 열경화성 복합재 온도분포 연구)

  • 전영준;엄문광;변준형;이상관
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.10a
    • /
    • pp.230-233
    • /
    • 2003
  • Among the various manufacturing processes of composites, the tape lay-up process of thermoset prepreg has many advantages compared to autoclave or hot press forming. It has a high potential to process automation and continuous fabrication. In this study, temperature distribution of composite exposed in hot gas was studied numerically and the validity of the analysis was verified by the experiments.

  • PDF

Thermal Inspection of GFRP using Liquid Crystal (액정을 이용한 GFRP의 열적시험법에 관한 연구)

  • Kim, Y.H.;Kwon, O.Y.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.10 no.2
    • /
    • pp.50-55
    • /
    • 1990
  • Flaws in GFRP(Glass Fiber Reinforced Plastics) were thermally detected using cholesteric liquid crystals. Presence of flaws changes the thermal conductivity of GFRP, and disturbs heat flow. When a uniform heat source is applied, the surface temperature of flawed region is different from that of sound region. The surface temperature distributions were measured by thermo-optic properties of liquid crystal. Since the colors of liquid crystal indicate temperature distribution of GFRP surface, the thermal disturbance by flaws could be detected. The locations of flaws in GFRP could be determined from the distribution of liquid crystal colors.

  • PDF

Fiber Optic Sensor for the Detection of Abnormal Structural Signals from Various Constructions (구조물 이상탐지용 광섬유 센서)

  • Kwon, Il-Bum;Lee, Youn-Jae;SeoMoon, Ung;Jo, Jae-Heung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.6 s.52
    • /
    • pp.133-135
    • /
    • 2006
  • We propose and fabricate a novel fiber optic sensor for the detection of abnormal structural signals from various constructions. It's advantages are highly sensitive. small in dimension and electro-magnetic immune. Since this sensor was simply constructed with a single-mode fiber at infra-red wavelength and a laser-diode with the wavelength of 625 nm, the modes in the end of the optical fiber were not show as Gaussian distributed. So, we used the change of the mode distribution to get the sensor output by the external abnormal effect of structures. We investigated the resonance by performing the bending test of an aluminum beam attached with the fiber sensor. In the test, we could obtained a feasible signal to sense the abnormal condition of structures.

Measurement of Pile Load Transfer Using Fiber Bragg Grating Sensor (광섬유 격자소자에 의한 말뚝의 하중전이 측정)

  • 오정호;이원제;이상배;이우진
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.4
    • /
    • pp.201-208
    • /
    • 2000
  • Axial load distribution in model piles was measured by fiber Bragg Grating(FBG) sensor to investigate a possibility of analyzing the load transfer mechanism by Fiber Optic sensor system. Since FBGs of different wave lengths can be multiplexed in an optical fiber, the installation of sensor system and the measurement of strains are relatively simple, compared with consisting strain gages. In this study, FBG sensors and electric strain gages were embedded in the same piles and the distributions of load transfer by two sensor systems were measured. It was observed from the test results that the variations of axial load by both systems showed insignificant difference and that the measurements by FBG were smoother than those by strain gage. Under the environments of laboratory testing, survival rate of embedded FBG system was higher than that of strain gage. Therefore, it was concluded that the use of FBG sensor has a great potential for the measurement of load transfer for pile foundation.

  • PDF

Development of the Big-size Statistical Volume Elements (BSVEs) Model for Fiber Reinforced Composite Based on the Mesh Cutting Technique (요소 절단법을 사용한 섬유강화 복합재료의 대규모 통계적 체적 요소 모델 개발)

  • Park, Kook Jin;Shin, SangJoon;Yun, Gunjin
    • Composites Research
    • /
    • v.31 no.5
    • /
    • pp.251-259
    • /
    • 2018
  • In this paper, statistical volume element modeling method was developed for multi-scale progressive failure analysis of fiber reinforced composite materials. Big-size statistical volume elements (BSVEs) was considered to minimize the size effect in the micro-scale, by including as many fibers as possible. For that purpose, a mesh cutting method is suggested and adapted into the fiber model generator that creates finite element domain rapidly. The fiber defect model was also developed based on the experimental distribution of the fiber strength. The size effects from the local load sharing (LLS) are evaluated by increasing the fiber inclusion in the micro-scale model. Finally, continuum damage mechanics (CDM) model to the fiber direction was extracted from numerical analysis on BSVEs. And it was compared with strength prediction from typical representative volume element (RVE) model.

Fire Resistance Performance for Hybrid Fiber Reinforced High Strength Concrete Column Member (하이브리드 섬유보강 고강도콘크리트 기둥부재의 내화성능)

  • Won, Jong-Pil;Jang, Chang-Il;Lee, Sang-Woo;Kim, Heung-Youl;Kim, Wan-Young
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.6
    • /
    • pp.827-832
    • /
    • 2008
  • This study evaluated fire resistance performance for hybrid (polypropylene+steel) fiber reinforced high strength concrete column. Full-size columns were constructed and tested with or without fibers using ISO-834 fire curve. As the result of test, Control specimen occurred serious spalling and indicated rapidly internal temperature increasing. Specimen with polypropylene fiber occurred not spalling but steady internal temperature increasing. Specimen with hybrid fiber occurred not spalling as well as does not propagated temperature distribution. Therefore, hybrid fiber reinforced column specimen indicated a good fire resistance performance than other cases.

Analysis of Interfacial Shear Strength of Fiber/Epoxy Composites by Microbond Test and Finite Element Method (미소접합시험과 유한요소법을 통한 섬유/에폭시 복합재의 계면 전단강도 해석)

  • Kang, Soo-Keun;Lee, Deok-Bo;Choi, Nak-Sam
    • Composites Research
    • /
    • v.19 no.4
    • /
    • pp.7-14
    • /
    • 2006
  • Interfacial shear strength between epoxy and carbon fiber has been analyzed utilizing the microbond specimen with an epoxy micro-droplet adhered onto single carbon fiber. The interfacial shear stress distributions along the fiber/matrix interface were calculated by finite element analysis using three kinds of finite element models such as droplet model, circular-crosssection model and pull-out model. Conclusions were obtained as follows. (1) Interfacial shear stress distribution showed that larger stresses were concentrated in the fiber/matrix interface for microbond test than for pull-out test. Thus, debonding at the fiber/matrix interface during microbond test was liable to occur at low load level. (2) Microbond test showed higher interfacial strength which was caused by various effects of micro-droplet geometry and size as well as stress concentration in the region contacting with the micro-vise tip.

Improved Closure Approximation for Numerical Simulation of Fiber Orientation in Fiber-Reinforced Composite (단섬유 보강 복합재료에서의 섬유배향의 수치모사를 위한 개선된 근사모델)

  • D.H. Chung;T.H. Kwon
    • The Korean Journal of Rheology
    • /
    • v.10 no.4
    • /
    • pp.202-216
    • /
    • 1998
  • Improved version of previous 'Orthotropic' closure approximation, termed 'ORW' has been numerically developed using new homogeneous flow data. Previous 'Orthotropic' closure approximation, i.e., ORF or ORL showed non-physical oscillation for interaction coefficient $C_1$<0.001 at simple shear flow. It also shows non-physcial oscillation and under-prediction compared with 'Distribution Function Calculation' at non-homogeneous flow of center-gated disk. These phenomena are mainly due to the flow data of 'Distribution Function Calculation' which were used for least-square optimization. ORW obtained by fitting flow data of low interaction coefficient does not show non-physical oscillation and results in reasonably good behaviors at non-homogeneous flows as well as homogeneous flows. Fitting function forms have not been found to improve overall behaviors. It has been found that considering all the eigenvalues of orientation tensor (including the third eigenvalues) might end up with a better closure approximation than just considering the first and second eigenvalues. It is, however, very important and yet difficult to select appropriate function forms of eigenvalues. Numerical simulation including coupling and in-plane velocity gradient effects were performed for injection mold filing process with a film-gated strip and a center-gated disk using ORW and various other closure approximations for comparisons. Although ORW is in excellent agreement with 'Distribution Function Calculation', the predicted results seem to have consistent error in comparison with experimental data. The diffusivity term with constant interaction coefficient might have to be further investigated in order to accurately describe orientation states.

  • PDF