• Title/Summary/Keyword: Fiber Ratio

Search Result 2,426, Processing Time 0.027 seconds

Behavior of Steel Fiber Reinforced Concrete Columns under Cyclic Loading

  • Chang Kug-Kwan;Lee Hyun-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.3 s.81
    • /
    • pp.415-423
    • /
    • 2004
  • To improve the brittle column behavior during seismic excitation, benefits of using steel fiber reinforced concrete in columns were investigated. For experimental study, eight specimens were used to evaluate the shear enhancement effect. The variables in this study were amount of shear reinforcement ratio (i.e., 0.26, 0.21 $\%$) and steel fiber volume fraction (i.e., 0.0, 1.0, 1.5, 2.0$\%$). The test results indicated that the maximum enhancement of shear capacity was shown in $1.5\%$ steel fiber content. In addition, to predict the maximum shear strength, equations of ACI 318-99, AIJ MB, NZS 3101, Hirosawa and Priestley were reviewed. From the parametric and regression study, modified Priestely equation was proposed by adding steel fiber effect.

Engineering Properties of Fiber Mixed Soil (섬유 혼합토의 공학적 특성)

  • 장병욱;박영곤
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.1
    • /
    • pp.116-124
    • /
    • 2002
  • Natural resources fur the construction materials such as good soil, sand, and coarse aggregates have been encountered to be short due to excessive use by human. Even though some soil has been found to be unsuitable for construction materials, soil with reinforcement can naturally be an answer to these alternatives. According to recently published papers on fiber mixed soil, fiber mixed with soil can improve shear strength, compressive strength and post-peak load strength retention. In this study, a series of tests were performed to clarify the characteristics of fiber mixed soil and to give basic data for design and construction and their engineering properties, that is, unconfined compressive strength, splitting tensile strength, shear strength, crack by drying, freeze-thaw, creep and Poisson\`s ratio, were investigated and analyzed. It has been shown that fiber mixed soil is one of good alternatives fur the civil and building construction materials.

Mixing and Flexural Strength Characteristics of HPFRCCs using Steel Cord and Carbon Fiber (강섬유와 탄소섬유를 사용한 고인성 시멘트 복합체의 비빔 및 휨강도 특성)

  • Lee, Won-Suk;Byun, Jang-Bae;Yun, Hyun-Do;Kim, Sun-Woo;Jeon, Esther
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.377-380
    • /
    • 2006
  • HPFRCCs(High performance fiber reinforced cementitious composites) is a class of FRCCs(Fiber reinforced cementitious composites) exhibit multiple crack. Multiple crack lead to improvement in ductility, toughness, and deformation capacity under compressive and tensile stress. These properties of HPFRCCs are affected by type of fiber, water cement ratio, type of admixture and rate of substitution. Furthermore these influence dispersion of fiber, mixing performance and fluidity of mixture. In this paper, HPFRCCs made of steel cord and carbon fiber were tested with water cement ratio, type of admixture and rate of substitution to evaluate characteristics of mixing and flexural strength.

  • PDF

A Case-Control Study on the Relationship of Fiber Intake and Hemorrhoids (섬유질 섭취와 치질의 상관성에 관한 환자-대조군 연구)

  • 이상선
    • Journal of Nutrition and Health
    • /
    • v.27 no.1
    • /
    • pp.71-78
    • /
    • 1994
  • Recently the incidence of hemorrhoids has been increased. There were various factors related to hemorrhoids, the amount of fiber intake was known as one of them. And so we performed this case-control study to investigate the association of hemorrhoids and fiber intake. The data was obtained by the combination of self-administered questionnaire and personal interview. The study population was consisted of matched 156 pairs, the cases were selected from S-hospital in Seoul, the age and sex matched control from the general population. The statistical analysis was performed by matched-analysis. The results summarized as follow : 1) As socio-economic status were low, the odds ratio of hemorrhoids were high. 2) There was significant association between hemorrhoids and regularity of eating time rather than regularity of defecation. 3) The odds ratio of hemorrhoids was 3 times higher in the presence of constipation. 4) The incidence of hemorrhoids was influenced by psychological characteristics such as somatization, obsessive-compulsive, depression, and anxiety. 5) Fiber intake was significantly lower in the cases compared to the controls. When the constipation was controlled, the fiber intake was still lower in the cases. These data provide additional evidence that the fiber intake was related to hemorrhoids.

  • PDF

Evaluation on Mechanical Properties of PP and Jute Fiber Concrete at Elevated Temperatures (PP섬유 및 Jute섬유를 혼입한 콘크리트의 고온 역학적 특성 평가)

  • Yoon, Min-Ho;Kim, Gyu-Yong;Choe, Gyoeng-Choel;Lee, Young-Wook;Han, Sang-Hyu;Lee, Bo-Kyeong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.34-35
    • /
    • 2014
  • In this study, the effects of high temperatures on the compressive strength and elastic modulus of HPC with pp and jute fiber (jute fiber addition ratio: 0.075 vol%; length: 12 mm; PP fiber addition ratio: 0.075 vol%; length: 12 mm) were experimentally investigated. The work was intended to clarify the influence of elevated temperatures ranging from 20 to 500℃ on the material mechanical properties of HPC at 80 MPa.

  • PDF

Analysis of fiber-reinforced elastomeric isolators under pure "warping"

  • Pinarbasi, Seval;Mengi, Yalcin
    • Structural Engineering and Mechanics
    • /
    • v.61 no.1
    • /
    • pp.31-47
    • /
    • 2017
  • As a relatively new type of multi-layered rubber-based seismic isolators, fiber-reinforced elastomeric isolators (FREIs) are composed of several thin rubber layers reinforced with flexible fiber sheets. Limited analytical studies in literature have pointed out that "warping" (distortion) of reinforcing sheets has significant influence on buckling behavior of FREIs. However, none of these studies, to the best knowledge of authors, has investigated their warping behavior, thoroughly. This study aims to investigate, in detail, the warping behavior of strip-shaped FREIs by deriving advanced analytical solutions without utilizing the commonly used "pressure", incompressibility, inextensibility and the "linear axial displacement variation through the thickness" assumptions. Studies show that the warping behavior of FREIs mainly depends on the (i) aspect ratio (shape factor) of the interior elastomer layers, (ii) Poisson's ratio of the elastomer and (iii) extensibility of the fiber sheets. The basic assumptions of the "pressure" method as well as the commonly used incompressibility assumption are valid only for isolators with relatively large shape factors, strictly incompressible elastomeric material and nearly inextensible fiber reinforcement.

Compressive Behavior of Hybrid Steel Fiber Reinforced Ultra-High Performance Concrete (하이브리드 강섬유 보강 초고성능 콘크리트의 압축거동)

  • Lim, Woo-Young;Hong, Sung-Gul
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.2
    • /
    • pp.213-221
    • /
    • 2016
  • Uniaxial compression tests for ultra-high performance hybrid steel fiber reinforced concrete (UHPC) were performed to evaluate the compressive behavior of UHPC. The UHPC for testing contains hybrid steel fibers with a predetermined ratio using a length of 19 mm and 16 mm straight typed steel fibers. Test parameter was determined as a fiber volume ratio to investigate the effect of fiber volume ratio on the strength and secant modulus of elasticity. Test results showed that the compressive strength and elastic modulus of UHPC increased with increasing the fiber volume ratio. Based on the test results, the compressive strength and modulus of elasticity equations were proposed as function of the compressive strength of unreinforced and fiber reinforced UHPC, respectively. The simplified equations for predicting the mechanical properties of the UHPC were a good agreement with the test data. The proposed equations are expected to be applied to the SFRC and UHPC with steel fibers.

Analysis on the Shear Failure of Fiber Mixed Soil (섬유혼합토의 전단파괴 해석)

  • 박영곤
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.42 no.2
    • /
    • pp.86-92
    • /
    • 2000
  • The model using homogenization technique based on energy concept for the prediction of the failure criterion of staple fiber mixed soil was developed to increase the practice and the application of staple fiber as a reinforcement for improving soft ground. Parameters of the model are aspect ratio and volumetric content of fiber, cohesion and internal friction angle of soil, adhesion intercept and interface friction angle of soil and fiber. It is considered that the model developed in this study is applicable to the soil composed of clay, silt and sand mixed by thread types of fiber such as steel bar, steel fiber, natural fiber etc.

  • PDF

Highly Utilized Fiber Plant with Extended Reach and High Splitting Ratio Based on AWG and EDFA Characteristics

  • Syuhaimi, Mohammad;Mohamed, Ibrahim
    • ETRI Journal
    • /
    • v.35 no.5
    • /
    • pp.786-796
    • /
    • 2013
  • In this paper, we propose a hybrid time-division multiplexing and dense wavelength-division multiplexing scheme to implement a cost-effective and scalable long-reach optical access network (LR-OAN). Our main objectives are to increase fiber plant utilization, handle upstream and downstream flow through the same input/output port, extend the reach, and increase the splitting ratio. To this end, we propose the use of an arrayed waveguide grating (AWG) and an erbium-doped fiber amplifier (EDFA) in one configuration. AWG is employed to achieve the first and second objectives, while EDFA is used to achieve the third and fourth objectives. The performance of the proposed LR-OAN is verified using the Optisystem and Matlab software packages under bit error rate constraints and two different approaches (multifiber and single-fiber). Although the single-fiber approach offers a more cost-effective solution because service is provided to each zone via a common fiber, it imposes additional losses, which leads to a reduction in the length of the feeder fiber from 20 km to 10 km.