Behavior of Steel Fiber Reinforced Concrete Columns under Cyclic Loading  

Chang Kug-Kwan (Dept. of Architectural Engineering, Seoul National University of Technology)
Lee Hyun-Ho (Dept. of Architectural Engineering, Dong yang University)
Publication Information
Journal of the Korea Concrete Institute / v.16, no.3, 2004 , pp. 415-423 More about this Journal
Abstract
To improve the brittle column behavior during seismic excitation, benefits of using steel fiber reinforced concrete in columns were investigated. For experimental study, eight specimens were used to evaluate the shear enhancement effect. The variables in this study were amount of shear reinforcement ratio (i.e., 0.26, 0.21 $\%$) and steel fiber volume fraction (i.e., 0.0, 1.0, 1.5, 2.0$\%$). The test results indicated that the maximum enhancement of shear capacity was shown in $1.5\%$ steel fiber content. In addition, to predict the maximum shear strength, equations of ACI 318-99, AIJ MB, NZS 3101, Hirosawa and Priestley were reviewed. From the parametric and regression study, modified Priestely equation was proposed by adding steel fiber effect.
Keywords
steel fiber; volume fraction; aspect ratio; shear; strengthening effect; column;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Masuta, et al., Cyclic Test of Steel Fiber Reinforced Concrete Columns, Proceeding of the Japan Concrete Institute, Vol.19. No.2, 1997, pp.1521-1526. (In Japanese)
2 Nagasaka T., Mochizuki S. and Makitani E., Study on Shear Capacity of Reinforced Concrete Columns with Steel Fibers Based on Composite Resistant Mechanism of Steel Fibers and Conventional Hoops, Journal of Struct. Constr. Engng,, AIJ, No.410, 1990, pp.53-61. (In Japanese)
3 Yashiro T., Tanaka Y., Ro Y. and Hirose K., Study on Shear Failure of Steel Fiber Reinforced Concrete Short Columns in Consideration of Arrangement of Ties, Fiber Reinforced Cements and Concretes: Recent Developments, EAS., 1989, pp.489-498
4 Makitani et al., Shear Behavior and Dynamic Effect of Steel Fiber Reinforced Concrete Columns, Proceeding of the Japan Concrete Institute, 1985, pp. 361-364. (In Japanese)
5 Sakai M., Nakamura N. and Takazuka T., Improvement of Earthquake Resistance of Reinforced Concrete Column by Using Steel Fiber, Technical Report of Japan Steel Pipe, No81, 1979, pp.15-25. (In Japanese)
6 Priestley M.J.N., et al., Seismic Shear Strength of Reinforced Concrete Columns, ASCE Journal of Structural Engineermg, Vol.120, No.8, 1994, pp. 2310-2329   DOI   ScienceOn
7 ACI, Manual of concrete practice, ACI, 2002
8 Lee, H.H. and Chang, K.K., Shear capacity determination of steel fiber reinforced RC columns, Proceeding of the Korea Concrete Institute, Vol.13, No.2, 2001, pp.891-896. (In Korean)
9 ACI Committee 318, Building Code Requirements for Reinforced Concrete (ACI 318-99), American Concrete Institute, 1999
10 Priestley M.J.N. and Park R., Strength and Ductility of Concrete Bridge Columns under Seismic Loading, ACI Structural Journal, Vol.84, No.l, 1987, pp.69-76
11 AIJ, Design Guidelines for Earthquake Resistant Reinforced Concrete Buildings Based on Inelastic Displacement Concept (Draft), AIJ, 1997
12 New Zealand, Code of Practice for the Design of Concrete Structures, NZS 3101, 1989
13 AIJ, Design Guidelines for Earthquake Resistant Rein-forced Concrete Buitdings Based on Ultimate Strength Concept, AIJ, 1990