• 제목/요약/키워드: Ferromagnetic Material

검색결과 185건 처리시간 0.033초

Magnetic properties of thin films of a magnetocaloric material FeRh

  • Jekal, Soyoung;Kwon, Oryong
    • EDISON SW 활용 경진대회 논문집
    • /
    • 제2회(2013년)
    • /
    • pp.294-298
    • /
    • 2013
  • A FeRh alloy is a well-known efficient magnetocaloric material and some experimental and theoretical studies of bulk FeRh have been reported already by several groups. In this study we report first-principles calculations on magnetic properties of different thickness FeRh thin films in order to investigate the possibility to enhance further the magnetocaloric efficiency. We used two methods of a Vienna Ab-initio Simulation Package (VASP) code and SIESTA package. We found that the FeRh thin films have quite different magnetic properties from the bulk when the thickness is thinner than 6-atomic-layers. While bulk FeRh has a G-type antiferromagnetic(AFM) state, thin films which are thinner than 6-atomic-layers have an A-type AFM state or a ferromagnetic (FM) state. We will discuss possibility of magnetic phase transitions of the FeRh thin films in the view point of a magnetocaloric effect. And we found 4-, 5-, 6-layers films with Fe surface and 7-layers film with Rh surface are FM and they have relatively small magnetocrystalline anisotropy (MCA) energy about less than 70 meV. The small MCA energy leads to reduction of the strength of magnetic field in operating a magnetic refrigerator.

  • PDF

A STUDY OF MAGNETIC ALIGNMENT OF DIE-UPSET Pr-Fe-B-Cu MAGNETS

  • Kwon, H.W.;Ma, T.J.;Harris, I.R.
    • 한국자기학회지
    • /
    • 제5권5호
    • /
    • pp.416-420
    • /
    • 1995
  • An attempt has been made to investigate the mechanism of magnetic alignment in the magnets produced by upset forging the $Pr_{20}Fe_{74}B_{4}Cu_{2}$ cast bulk alloy. Upset forging of the cast alloy was carried out for 20 sec to an 80 % thickness reduction (strain rate : $4{$\times}10^{-2}s^{-1}$) in an open die configuration at varying temperatures in the range $600^{\circ}-900^{\circ}C$. It has been found that the upset forging process at temperatures above $800^{\circ}C$ can achieve a magnetic alignment to a great extent from copper-containing Pr-Fe- B-type cast ingot. The growth manner of the ferromagnetic $Pr_{2}Fe_{14}B$ matrix grain in Pr-Fe-B-type alloys was studied by examining the morphology change of the matrix grain in sintered body, and it was found that the matrix grains grew in anisotropic manner such that the grain grew more rapidly along the a- or b-axis than along the c-axis. This anisotropic grain growth led to the plate-like shape of the matrix grain. The magnetic alignment during the upset forging was attributed to grain boundary gliding of the plate-like grains, and the geometry of the grains in the cast ingot and the presence of a large amount of the praseodymium-rich grain boundary phase were thought to play a key role in the achievement of magnetic alignment.

  • PDF

반자성 물질을 이용한 자기공명영상검사에서의 인공물 감소 (Reduction of Artifacts in Magnetic Resonance Imaging with Diamagnetic Substance)

  • 최우전;김동현
    • 한국방사선학회논문지
    • /
    • 제13권4호
    • /
    • pp.581-588
    • /
    • 2019
  • 자기공명영상검사는 조직의 대조도 와 해상력이 우수하지만, 인공물이 발생 될 경우 진단에 영향을 주어 판독이 불가능한 영상을 생성하기도 한다. 치아에 삽입된 금속은 강자성체 또는 상자성체로 되어있는 경우가 대부분이며 자화율 차이로 인하여 기하학적 왜곡을 유발하여 영상진단에 저해되는 경우가 많으며 이를 저감시킬 필요가 있다. 이에 본 연구는 반자성 물질을 사용에 따른 금속 인공물 분석을 실시하고자 한다. 자성 물질로는 치아교정용 와이어와 브라켓인 스테인리스 스틸이 사용되었고 반자성 물질은 구리, 아연, 비스무트를 사용하였다. 검사장비는 1.5T, 3T가 사용되었으며 사용된 시퀀스는 SE, TSE, GE, EPI을 사용하여 측정하였다. 자체 제작된 팬텀을 물질은 균등한 신호를 위하여 아가로스 겔(10%)을 사용하였으며 인공물 유발 물질은 스테인리스 스틸은 팬텀의 정중앙에 위치시켜 검사하고 각 길이 10mm의 정 육면체 반자성 물질의 씌워 검사하였다. 인공물 측정은 Image J를 사용하여 순수한 팬텀 영상에서 자성물질을 포함한 영상을 감산하여 얻은 영상에서 Low Threshold 값을 10으로 설정 한 후 Wand tool을 사용하여 인공물 영역설정 후 면적을 구하였다. 스테인리스 스틸에서 발생한 금속 인공물은 반자성 물질 중 비스무트를 사용한 영상에서 금속 인공물이 가장 많이 감소하였으며 구리와 아연은 약간은 감소하지만, 그 정도의 차이는 크지 않다고 하겠다. 이러한 이유는 비스무트의 반자성 자화율이 가장 작아서 강자성체에서의 자화율을 가장 많이 상쇄하였기 때문이라고 생각된다. 1.5T 와 3T 모두에서 비스무트를 사용한 영상의 인공물이 가장 적게 나왔다. 시퀀스별 인공물 감소는 1.5T에서는 TSE에서 가장 많이 인공물이 감소하였으며 3T에서는 SE에서 가장 많은 인공물이 감소하였다. 따라서 반자성물질의 따른 인공물 변화의 결과는 자화율(${\chi}$)이 가장 낮은 비스무트를 사용한 영상에서 금속인공물이 기준인 Implant 인공물 보다 줄어든 양상을 보여 자화율이 낮은 물질일수록 금속 인공물이 줄어든다는 것을 알 수 있었으며, 기존 금속 인공물의 해결 방법의 단점으로 지적되어온 스캔 시간의 증가 등이 나타나지 않으면서도 인공물을 줄일 수 있는 방법으로 향후 치아 교정 물질뿐만 아니라 치아 보철물 전체에 대한 금속 인공물 저감에 관한 연구의 기초 자료로 사용될 것으로 사료된다.

Indirect Fault Detection Method for an Onboard Degaussing Coil System Exploiting Underwater Magnetic Signals

  • Jeung, Giwoo;Choi, Nak-Sun;Yang, Chang-Seob;Chung, Hyun-Ju;Kim, Dong-Hun
    • Journal of Magnetics
    • /
    • 제19권1호
    • /
    • pp.72-77
    • /
    • 2014
  • This paper proposes an indirect fault detection method for an onboard degaussing coil system, installed to reduce the underwater magnetic field from the ferromagnetic hull. The method utilizes underwater field signals measured at specific magnetic treatment facilities instead of using time-consuming numerical field solutions in a three-dimensional space. An equivalent magnetic charge model combined with a material sensitivity formula is adopted to predict fault coil locations. The purpose of the proposed method is to yield reliable data on the location and type of a coil breakdown even without information on individual degaussing coils, such as dimension, location and number of turns. Under several fault conditions, the method is tested with a model ship equipped with 20 degaussing coils.

DC 리액터형 고온초전도한류기의 전력계통 연계를 위한 자기철심리액터의 설계 (Design of the Magnetic Core Reactor for the connection to the Power System of DC Reactor Type High Temperature Superconducting Fault Current Limiter)

  • 임대준;배덕권;김호민;이찬주;윤경용;윤용수;고태국
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.322-325
    • /
    • 2002
  • In this paper, the power-linking device connecting the high-Tc super-conducting(HTS) coil to the power system in the DC reactor type three-phase high-Tc superconducting fault current limiter (SFCL) has been designed. This design was triggered from the concept that the magnetic energy could be exchanged into the electrical energy each other. Ferromagnetic material is used as the path of magnetic flux. The device mentioned above was named Magnetic Core Reactor(MCR). MCR was designed to minimize the voltage drop caused by copper loss. The current density of the conductor was 1.3 A/mm$^2$ and % voltage drop was 2%.

  • PDF

강자성체의 자기정숙을 위한 히스테리시스 모델링 기법 연구 (A Study of Hysteresis Modeling Method for Magnetic Stealth of Ferromagnetic Materials)

  • 원혁;박관수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.884-885
    • /
    • 2011
  • A great deal of external magnetic variation is required to demagnetize a magnetic material. In order to analyze a demagnetization model, hysteresis is employed and the best numerical analysis technique so far, regarding hysteresis, is Preisach model. In general, Preisach model, however, bears the instability problem with respect to convergence and hence in this paper, a method adopting M-B variables is proposed to solve the problem. In addition, comparison is made between the experimental MTF equipment and the hysteresis modeling technique for the purpose of developing an effective demagnetization protocol.

  • PDF

MR 밸브의 전자기적 설계와 성능 평가 (Electromagnetic Design and Performance Evaluation of an MR valve)

  • 김기한;남윤주;박명관
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.968-973
    • /
    • 2007
  • This paper presents an electromagnetic design for the magneto-rheological fluid valve. The MR valve can control high-level fluid power without moving parts, due to the apparent viscosity controllability of the MR fluid in magnetic fields. In order to improve the static characteristic of the MR valve, the length of the flux path is decreased by removing the unnecessary bulk of the yoke. Then, in order to improve the dynamic and hysteretic characteristics, the magnetic reluctance of the ferromagnetic material is increased by minimizing the cross sectional area through which the flux passes. Two MR valves, one is a conventional type valve and the other is the proposed one, were fabricated and performance evaluation is experimentally achieved through the comparison study using by-pass damper system.

  • PDF

강자성체 구조물의 표면결함검출을 위한 와전류탐상 비파괴검사 (Eddy Current NDT for Detection of Defect on Ferromagnetic Material)

  • 이향범
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2002년도 하계학술대회 및 세미나
    • /
    • pp.49-52
    • /
    • 2002
  • 본 논문에서는 강자성체 물질을 사용하는 구조물들에 발생되는 결함을 와전류탐상을 이용하여 검출하기 위한 비파괴검사방법에 대하여 제시하였다. 와전류탐상은 전자기비파괴검사방법으로 초음파탐상법과 같은 방법에 비교하여 비접촉식이며 고속으로 검사가 가능하다는 장점이 있다. 본 연구에서 사용되는 매질인 강자성체의 경우 비자성체에 비하여 표피효과에 의한 침투깊이가 얇기 때문에 강자성체를 위한 주파수를 별도로 선정하여야 한다. 또한 고속으로 움직이는 경우 속도기전력에 의한 효과를 고려하여야 한다. 본 연구에서는 와전류센서를 제작하여 실제 강자성체에 적용하는 경우 어떠한 특성을 나타내는가에 대하여 고찰하였다.

  • PDF

자기스위치 시스템의 파라메다 최적화 및 출력 안정화에 관한 연구 (A Study on parameter optimization and output stabilization of Magnetic Switch System.)

  • 전상영;이주희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.637-641
    • /
    • 1989
  • We have developed 3-stage of Magnetic Switch System based on the nonlinearities of ferromagnetic material used in the saturable inductor, and made experiment of parameter optimization and output stabilization of Magnetic Switch System. The cross-section and conductor burns of each satarable inductor were optimized 30 $cm^2$ 19.25 $cm^2$ 5, and 25 $cm^2$ 2, respectively. With this condition, 6.2 us [FWHM], 96 A pulse at first stage was compressed into 0.4 us[FWHM], 1.61 kA pulse at last stage. The current gain and compression ratio were 16.8, 17, respectively. ln addition, System output was stabilized with reset current of 6 A, 200 us.

  • PDF

Removal of Cu(II) ions by Alginate/Carbon Nanotube/Maghemite Composite Magnetic Beads

  • Jeon, Son-Yeo;Yun, Ju-Mi;Lee, Young-Seak;Kim, Hyung-Il
    • Carbon letters
    • /
    • 제11권2호
    • /
    • pp.117-121
    • /
    • 2010
  • The composites of alginate, carbon nanotube, and iron(III) oxide were prepared for the removal of heavy metal in aqueous pollutant. Both alginate and carbon nanotube were used as an adsorbent material and iron oxide was introduced for the easy recovery after removal of heavy metal to eliminate the secondary pollution. The morphology of composites was investigated by FE-SEM showing the carbon nanotubes coated with alginate and the iron oxide dispersed in the alginate matrix. The ferromagnetic properties of composites were shown by including iron(III) oxide additive. The copper ion removal was investigated with ICP AES. The copper ion removal efficiency increased greatly over 60% by using alginate-carbon nanotube composites.