• Title/Summary/Keyword: Fenton's reagent

Search Result 39, Processing Time 0.026 seconds

Organic Wastewater Treatment Using Modified Fenton's Oxidation (변형 펜턴산화법을 이용한 유기폐수의 처리)

  • Kim, Ji Yeon;Yoon, Tai Il;Park, Se Jin
    • Clean Technology
    • /
    • v.5 no.1
    • /
    • pp.49-61
    • /
    • 1999
  • Fenton's oxidation can improve the biodegradability of refractory organic wastewater by generating $OH{\cdot}$ which is one of the most reactive species. Fenton's reagent is used to treat a variety of industrial waste containing a range of toxic organic compounds. But this process cannot be economical because of high chemical cost of $H_2O_2$, ferrous ion solution and high sludge disposal cost. In this study, we proposed a modified Fenton's oxidation process which can reduce the reagent cost and obtain better removal efficiencies with less Fenton's reagents, and have a good potential of sludge recycling. In modified Fenton reaction, ferrous ion solution is adjusted to optimal pH with NaOH. Then it added to the sample and reacted to $H_2O_2$. For the experiment, synthetic wastewater made of phenol, which is one of the typical water pollutants, was used and the ionic strength of this wastewater was controlled by adding $NaHCO_3$. The effects of DO, ionic strength, and $H_2O_2$ dosing methods were investigated. As a result, modified Fenton's treatment efficiencies are better than conventional Fenton's reaction treating leachate and dyeing wastewater. And modified Fenton's treatment efficiencies combined to the sludge recycling for a half of Iron dosage are as good as the conventional Fenton's for a normal Iron dosage.

  • PDF

Degradation of Membrane for PEM Fuel Cell with Hydrogen Peroxide (과산화수소에 의한 고분자전해질 연료전지 막의 열화)

  • Kim, Tae-Hee;Lee, Jung-Hun;Park, Kwon-Pil
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.438-442
    • /
    • 2006
  • The degradation of Nafion membrane by hydrogen peroxide was investigated in polymer electrolyte membrane fuel cell (PEMFC). Degradation tests were carried out in a solution of $10{\sim}30%$ hydrogen peroxide containing 4ppm $Fe^{2+}$ ion which is well known as Fenton's reagent at $80^{\circ}C$ for 48hr. Characterization of degraded membranes were examined through the IR, Water-uptake, Ion exchange capacity, mechanical strength and $H_2$ permeability. After degradation, C-F, S-O and C-O chemical bonds of membrane were broken by radical formed by $H_2O_2$ decomposition. Breaking of C-F bond which is the membrane backbone reduced the mechanical strength of Nafion membrane and hence induced pinholes, resulting in increase of $H_2$ crossover through the membrane. Also the decomposition of C-O and S-O, side chain and terminal bond of membrane, decreased the ion exchange capacity of the membrane.

  • PDF

Evaluation of Effective Process Operation for the Texitile Dyeing Wastewater by Ferrous Solution and Hydrogen Peroxide

  • Lee, Sang Ho;Moon, Hey Jin
    • Journal of Environmental Science International
    • /
    • v.13 no.11
    • /
    • pp.987-991
    • /
    • 2004
  • The purpose of this research is to evaluate the removal efficiencies of COD$\_$Cr/ and color for the dyeing wastewater by the different dosages of ferrous solution and H$_2$O$_2$ in Fenton process. In the case of H$_2$O$_2$ divided dosage for the Fenton's reagent 7:3 of H$_2$O$_2$ was more effective than 3:7 to remove COD$\_$Cr/ and color. The results showed that COD$\_$Cr/ was mainly removed by Fenton coagulation, where the ferric ions are formed in the initial step of Fenton reaction. On the other hand color was removed by Fenton oxidation rather than Fenton coagulation. The removal mechanism of COD$\_$Cr/ and color was mainly coagulation by ferrous ion, ferric ion and Fenton oxidation. The removal efficiencies were dependent on the ferric ion amount at the beginning of the reaction. However, the final removal efficiency of COD$\_$Cr/ and color was in the order of Fenton oxidation, ferric ion coagulation and ferrous ion coagulation. The reason of the highest removal efficiency by Fenton oxidation can be explained by the chain reactions with ferrous solution, ferric ion and hydrogen peroxide.

Treatment Efficiency of Complex Wastewater by Fenton's Oxidation Condition (펜톤산화에 따른 복합폐수의 처리효율연구)

  • Sung, Il-Wha
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.446-450
    • /
    • 2006
  • In order to treat the wastewater containing organic compound, pre-treatment system connected with MSP(molecular separation process) was investigated. With the aim of selecting an optimum process of Fenton's oxidation, removal efficiency of each process in the optimum reaction condition was recommended. The $Fe/H_{2}O_{2}$(ferric sulfate to hydrogen peroxide)reagent is referred to as the Fenton's regent, which produces hydroxyl radicals by the interaction of Fe with $H_{2}O_{2}$. The powerful oxidizing ability and extreme kinetic reactively of the hydroxyl radical was well established. Increasing dosage of $Fe/H_{2}O_{2}$ increased removal efficiency as molar ratio of $Fe/H_{2}O_{2}$ between 0.2 and 2.5. Optimum dosage of molar ratio was 1. The removal efficiency for reaction condition was increased as pH decreased when the molar ratio of $Fe/H_{2}O_{2}$ was 1.7. Fenton's oxidation was most efficient in the reaction time 35 min for complex wastewater. Also, coagulation aid experiments using kaolin resulted in 3% of kaolin dosage.

Characteristics of Phenol Degradation by Fenton Treatment (Fenton 처리에 의한 페놀의 분해 특성)

  • 최석순;염승호;차형준
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.2
    • /
    • pp.29-35
    • /
    • 1997
  • Phenol, often discharged from petroleum and fine chemical industries is potential carcinogen and was classified into priority pollutant by EPA in USA. It causes serious environmental and health problem if discharged to the environment such as soil or aquifer. The removal efficiency of phenol and COD using Fenton treatment(Hydrogen Peroxide and Ferrous Sulfate) was observed and biodegradability (BOD$_{5}$/COD$_{cr}$) of reaction products were also examined. When 50 mg/l of phenol was treated by Fenton's Reagent(50 mg/l of hydrogen peroxide and 900 mg/l of ferrous sulfate), the removal efficiency of phenol and COD was 100% and 80% respectively in 10 minutes, which suggested this method can be used as actual phenol removal process. The initial biodegradability of 500 mg/l phenol solution was 0.7 but decreased as hydrogen peroxide was increased.

  • PDF

Comparison of anti-oxidant activities of seventy herbs that have been used in Korean traditional medicine

  • Ko, Seong-Hee;Choi, Seong-Won;Ye, Sang-Kyu;Yoo, Sang-Ho;Kim, Hyun-Sook;Chung, Myung-Hee
    • Nutrition Research and Practice
    • /
    • v.2 no.3
    • /
    • pp.143-151
    • /
    • 2008
  • Many herbs have been used as therapeutics in Korean traditional medicine. In view of their clinical indications, anti-oxidant activity may contribute to their pharmacological effects. However, anti-oxidant information on these plants has not been available. In this study, seventy herbs which have been used in Korean traditional medicine were selected and screened for anti-oxidant activity using their water extracts. The anti-oxidant activity was assessed by their ability to inhibit three oxidation reactions; luminol/Fenton reagent, 2, 7-dichlorodihydrofluorescein(DCHF)/Fenton reagent and DCHF/peroxynitrite. In each assay, 70 herbs were divided into two groups; anti-oxidant group which inhibited the respective oxidation reaction and was majority(about 60 herbs), and pro-oxidant group which enhanced the oxidation reaction but was minority(more or less 10 herbs). When the herbs were listed in the order of their anti-oxidant strength, the orders obtained from each assay were found to be quite similar. The upper top rankers(more or less 10 herbs) in each assay showed strong activity compared to the others. The uppermost rankers in each assay were Rubus coreanus Miquel/Rubus schizostylus(覆盆子), Schisandra chinensis Baillon/Schizandra chinensis(五味子) and Terminalia chebula Retziusl Terminalia chebula(訶子). Of the pro-oxidant herbs, about 4-5 herbs were strongly pro-oxidant, which enhanced the control oxidation reactions to 150-300%. But the meaning of this observation is not known since few of them in one assay were also anti-oxidant in other assays. The results obtained in the present study may serve as information for understanding pharmacological effects of these herbs and developing new drugs from them.

Degradation of energetic compounds using an integrated zero-valent iron-Fenton process

  • Oh Seok-Young;Kim Byung J.;Chiu Pei C.;Cha Daniel K.
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.493-500
    • /
    • 2003
  • The effect of reductive treatment with elemental iron on the extent of mineralization by Fenton oxidation was studied for the explosive 2,4,6-trinitrotoluene (TNT) and hexahydro-l,3,5-trinitro-l,3,5-triazine (RDX) using a completely-stirred tank reactor (CSTR). The results support the hypothesis that TNT and RDX are reduced with elemental iron to products that are oxidized more rapidly and completely by Fenton's reagent. Iron pretreatment enhanced the extent of TOC removal by approximately $20\%\;and\;60\%$ for TNT and RDX, respectively. Complete TOC removal was achieved for TNT and RDX solutions with iron pretreatment under optimal conditions. On the other hand, without iron pretreatment, complete mineralization of TNT and RDX solutions were not achieved even with much higher $H_2O_2$ and $Fe^{2+}$ concentrations. The bench-scale iron treatment-Fenton oxidation integrated system showed more than $95\%$ TOC removal for TNT and RDX solutions under optimal conditions. The proposed zero-valent iron-Fenton process was evaluated with pink water from the Iowa Army ammunition plant. Results from batch and column experiments show that TNT, RDX, and octahydro-l,3,5,7-tetranitro-l,3,5,7-tetrazocine (HMX) were completely removed from the pink water and that triaminotoluene (TAT) and ${NH_4}^+$ were recovered as products in reduction with zero-valent iron. By using an integrated system, $83.3\pm4.2\%$ of TOC was removed in a CSTR with 10 mM of $Fe^{2+}$ and 50 mM of $H_2O_2$. These results suggest that the reduction products of TNT and RDX are more rapidly and completely mineralized by Fenton oxidation and that a sequential iron treatment-Fenton oxidation process may be a viable technology for pink water treatment.

  • PDF

Antioxidative Effects of Silymarin and Silybin Purified from Silybum marianum on Lipid Peroxidation (엉겅퀴로부터 분리 정제한 Silymarin 및 Silybin의 지질 과산화에 대한 항산화 효과)

  • 이백천;박종옥;류병호
    • The Korean Journal of Food And Nutrition
    • /
    • v.10 no.1
    • /
    • pp.37-43
    • /
    • 1997
  • This study was undertaken to evaluate as antioxidant activity against lipid peroxidation. Silymarin and silybin extracted from Silybum marianum were successively purified wit solvent fractionation by silica gel column chromatography. These isoflavonoid inhibited superoxide anion production in the xanthine oxidase system. In the rat liver microsomes, silymarin or silybin rapidly inhibited lipid peroxidation which was initiated enzymatically by reduced nicotinamide adenine dinucleotide phosphate(NADPH) or non-enzymatically by ascorbic acid or Fenton's reagent (H2O2+Fe2+). Mitochondrial lipid peroxidation was also inhibited by silymarin and silybin. silymarin and silybin inhibited on terminating radical chain reaction during lipid peroxidation in the enzymatic system of microsomes or in the linoleic acid hydroperoxide induced peroxidation system.

  • PDF

The Direct Decomposition of Ion-Exchange Resins by Fenton's Reagent (펜톤시약에 의한 이온교환수지의 직접산화분해)

  • Kim, Kil-Jeong;Shon, Jong-Sik;Ryu, Woo-Seog
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.3
    • /
    • pp.221-227
    • /
    • 2007
  • Fenton's reagent is applied to directly decompose the ion-exchange resins, IRN-78 and the mixed resin with IRN-77. The newly applied procedures is to dry the resin first and the catalyst solution is completely absorbed into the resin, then a limited dose of $H_2O_2$ is introduced for an effective reaction between the reagents within the resin. As a characteristic on the decomposition of IRN-78, the resin mixture should be heated to $40^{\circ}C$ to induce the initial reaction and lag time is also needed for about 20 minutes until the main reaction occurs. The effectiveness of the decomposition is investigated using $CuSO_4,\;Cu(NO_3)_2\;and\;FeSO_4$ as a catalyst and the decomposition rate is compared depending on the concentration of each catalyst and the amount of $H_2O_2$. The most effective catalyst was found to be $FeSO_4$ for IRN-78 alone and the mixed resin with IRN-77, and $FeSO_4$ showed a special effect that the reaction was initiated without heating and a lag time. Furthermore, the optimum concentration of the catalyst for each resin and the mixed one is suggested in the view point of the amount of $H_2O_2$ needed and the stability of the decomposition reaction.

  • PDF

A Study on the degradation of Lindane in water by a Photo-Fenton process and a UV/$H_2O_2$ process (Photo-Fenton 공정과 UV/$H_2O_2$ 공정을 이용한 Lindane의 분해특성 비교 연구)

  • Lee, Ju-Hyun;Choi, Hye-Min;Kim, Il-Kyu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.1
    • /
    • pp.109-117
    • /
    • 2010
  • In the present study, the degradation characteristics of Lindane by Advanced Oxidation Processes(UV/$H_2O_2$, Photo-Fenton process) were studied. The degradation efficiency of Lindane in aqueous solution was investigated at various initial pH values, Fenton's reagent concentrations and initial concentrations of Lindane. GC-ECD was used to analyze lindane. Lindane has not been degraded without application of AOPs over two hours. But, approximately 5% of lindane was degraded with UV or $H_2O_2$ alone. Lindane with UV/$H_2O_2$ process showed approximately 7% higher removal efficiency than $H_2O_2$ process. In the UV/$H_2O_2$ process, the pH values did not affect the removal efficiency. The optimal mole ratio of $H_2O_2/Fe^{2+}$ for lindane degradation is about 1.0 in Photo-Fenton process. Also, the experimental results showed that lindane removal efficiency increased with the decrease of initial concentration of lindane. Under the same conditions, the order lindane of removal efficiency is as following : Photo-Fenton process > UV/$H_2O_2$ process > $H_2O_2$ process. In addition, intermediate products were identified by GC-MS techniques. Than PCCH(Pentachlorocyclohexene) was identified as a reaction intermediate of the Photo-Fenton process.