• Title/Summary/Keyword: Fence-Type

Search Result 74, Processing Time 0.028 seconds

New Front Plate Structure of ac-PDP using Aluminum Fence-Type Electrode Coated with Anodic Aluminum Oxide

  • Lee, Mi-yeon;Yoon, Sang-Hoon;Kim, Yong-Seog
    • Journal of Information Display
    • /
    • v.8 no.4
    • /
    • pp.19-22
    • /
    • 2007
  • A new front plate structure of ac-PDP using fence-type aluminum electrode coated with anodic aluminum oxide was investigated. In this structure, ITO and glass dielectric layer were eliminated and expensive Ag BUS electrode was replaced with aluminum. Test panels were prepared using the new structure and their luminance and discharge characteristics were examined. These results indicate that the new structure provide a new way of cost reduction and enhancement of performance of ac-PDPs

New Front Plate Structure of ac-PDP using Aluminum Fence-type Electrode Coated with Anodic Aluminum Oxide

  • Lee, Mi-Yeon;Yoon, Sang-Hoon;Kim, Yong-Seog
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.127-130
    • /
    • 2007
  • A new front plate structure of ac-PDP was explored using fence-type aluminum electrode coated with anodic aluminum oxide.[1] In this structure, ITO and glass dielectric layer were eliminated and expensive Ag BUS electrode was replaced with aluminum. Test panels were prepared using the new structure and their luminance and discharge characteristics were examined. These results indicate that the new structure provide a new way of cost reduction and enhancement of performance of ac-PDPs

  • PDF

A Study on Rockfall Energy and Rockfall Protection Fence Applications on the Slope (사면에서 발생하는 낙석에너지와 낙석방지울타리 적용성에 관한 연구)

  • 김남호;신윤섭;박윤재;조종석
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.523-530
    • /
    • 2002
  • Recently, while rockfall occurs very frequently, a lot of researches on the rockfall protection fence Is in process. But the rockfall protection fence has been installed unrelated to slope characteristics, rockfall shape and rockfall height. Therefore, in this study we suggested the effective protection fence model considering about rockfall energy and energy absorbing capacity and we verified the model by field test. According to these results, it is more reasonable to evaluate rockfall energy based on the results of simulation program, which can be consider effects of energy decrease, than use the simplified method proposed by Japanese road association. And rockfall energy is affected by the size of supports and wire rope and the space of supports. As the results of comparing rockfall energy with energy absorbing capacity, type$\circled1$(the space of supports is changed to 3.0m)can be available for generally expected rockfall except the rock slope over 30m heights. But rockfall protection fence installed at the field, it should be partially reinforced after consideration of slope particularities and construction conditions.

  • PDF

A Study on Design Criteria of Rockfall Protection Fence Considering Reliability Index (신뢰성지수를 고려한 낙석방지울타리 설계기준 고찰)

  • Suk, JaeWook;Lee, JongGun;Kim, YongSoo;Moon, JoonShik
    • Tunnel and Underground Space
    • /
    • v.24 no.4
    • /
    • pp.275-281
    • /
    • 2014
  • The performance criteria of rockfall protection fence and reliability index were investigated considering characteristic of rockfall energy occurred at 160 cut slopes in national highway. As a result of study on statistic of variables that decide rockfall energy using Monte-Carlo simulation, the degree of slope was normal distribution type, mass of rockfall and height of slope was lognormal distribution type. The rockfall energy follows lognormal distribution because of statistical characteristic of mass of rockfall. The reliability index of rockfall protection fence was 0.678 and the failure probability of was very high as 24.9%. Proposed performance criteria of rockfall protection fence considering the scale of domestic rockfall energy is maximum 500 kJ and the range of reliability index was from 1.028 to 1.956. the failure probability of rockfall protection fence was from 14.8 to 2.5 percent if applying the performance criteria using the reliability index.

Improvement of the flow around airfoil/flat-plate junctures by optimization of the leading-edge fence (날개-평판 접합부에서의 날개 앞전 판 최적화를 통한 유동특성 향상)

  • Cho, Jong-Jae;Kim, Kui-Soon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.9
    • /
    • pp.829-836
    • /
    • 2009
  • 3-Dimensional flow which is represented by horseshoe vortex is generated as a type of secondary flow about the main flow. As well, it causes the flow loss. The present study deals with the leading edge fence shape on a wing-body junction to decrease a horseshoe vortex, one of the main factors to generate the secondary flow losses. The shape of leading-edge fence was optimized with the design variables of the installed height, length, width, and thickness of the fence as the design variables. Approximate optimization design method is used as the optimization. The study was investigated using $FLUENT^{TM}$ and $iSIGHT^{TM}$. Total pressure coefficient of the optimized design case was decreased about 7.5 % compare to the baseline case.

Evaluation for Non-Point Sources Reduction Effect by Vegetated Ridge and Silt Fence (식생밭두렁과 실트펜스를 이용한 밭 비점오염 저감효과 평가)

  • Kim, Dong-Hyeon;Kim, Sang-Min
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.5
    • /
    • pp.129-137
    • /
    • 2015
  • The objective of this study was to test the non-point source pollution (NPS) control by the vegetated ridge and silt fence through field monitoring. The experiment plots were established with three sizes which are 5 m width by 22 m length with 8 %, 3 % slope and 15m width by 15 m length with 6 % slope. Flumes with the floating type stage gages were installed at the outlet of each plot to monitor the runoff. For a rainfall monitoring, tipping bucket rain gage was installed within the experiment site. Water quality samples were monitored during the heavy rainfall occurred. The amount of rainfall from 4 monitored events ranged from 27.6 mm to 130 mm. The runoff reduction rate could vary depending on slope, soil, crop growth condition, rainfall amount, rainfall intensity, antecedent moisture condition, and many other factors. The runoff from vegetated ridge and silt fence treatment plots was 24.05 % and -8.28 % lower than that from control plot, respectively. The monitoring results showed that the average pollution loads reduced by vegetated ridge compared to control were BOD 36.62~53.60 %, SS 40.41~73.71 %, COD 39.34~56.41 %, DOC 49.08~53.67 %, TN 26.74~67.23 %, and TP 52.72~91.80 %; by silt fence compared to control were SS 41.73 %, COD 1.93 %, and TN 2.38 %. The paired t-test result indicated that the vegetated ridge and silt fence were statistically significant effect in SS load reduction, with a 5 % significant level. Monitored results indicated that vegetated ridge and silt fence were both effective to reduce the pollutant from the field surface runoff.

A Case of Fence Entrapment Associated with Anti-Welfare in a Thoroughbred Colt with Misbehavior at a Paddock (행동장애를 가진 Thoroughbred 수망아지에서 반동물복지와 연관된 펜스함정 1례)

  • Yang, Jae-Hyuk;Park, Yong-Soo
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.18 no.1
    • /
    • pp.25-28
    • /
    • 2016
  • The welfare of horses depends on satisfying both the physiological and psychological needs of the animal. The object of this study was to evaluate fence safety at the horse farm. A Thoroughbred colt with cribbing was found dead in a paddock. The fence of paddock is a four-pipe fencing. He cribbed the 2nd pipe from the top. But he couldn't pull his face because his incisors acted as hooks and two ramuses of the mandible was entrapped in a top pipe. So he was embarrassed and went down while he terribly struggled to get out his face. Finally, he was strangulated to death. Safe fencing is essential on a horse farm. The function of these fences are to protect the horses but it was more of a hazard. In order to safe management of horses, facial length of the horse and the pipe interval of the fence should be considered. Further research is needed to put a muzzle on the horses while they are at a paddock. This study provides important benchmarks for the equine industry to consider fence type and evaluate fence safety.

Effect of hanging-type sand fence on characteristics of wind-sand flow fields

  • Cheng, Jian-jun;Lei, Jia-qiang;Li, Sheng-yu;Wang, Hai-feng
    • Wind and Structures
    • /
    • v.22 no.5
    • /
    • pp.555-571
    • /
    • 2016
  • A hanging-type sand-retaining wall is a very common sand-blocking fence structure used to prevent sand movement. This type of wall is widely used along the Qinghai-Tibet and Gobi desert railways in Xinjiang, Western China. To analyze the characteristics of wind-sand flow fields under the effect of such a sand fence structure, a wind tunnel test and a field test were carried out. The wind tunnel test showed the zoning characteristics of the flow fields under the effect of the hanging-type sand-retaining wall, and the field test provided the sediment transport data for effective wind-proof interval and the sand resistance data in the front and behind the sand-retaining wall. The consistency of the wind-sand flow fields with the spatial distribution characteristic of wind-carried sand motion was verified by the correspondences of the acceleration zone in the flow field and the negative elevation points of the percentage variations of the sand collection rate. The spatial distribution characteristic of the field sand collection data further showed the spatial structural characteristic of the sandy air currents under the action of the hanging-type sand-retaining wall and the sand resistance characteristic of the sand-retaining wall. This systematic study on the wind-sand flow fields under the control of the hanging-type sand-retaining wall provides a theoretical basis for the rational layout of sand control engineering systems and the efficient utilization of a hanging-type sand-retaining wall.

A Plot Scale Experiment to Analysis the NPS Reduction by Silt Fence and Vegetated Ridge for Non-Irrigated Cropland (실트펜스와 식생밭두렁 적용을 통한 밭 비점오염 저감효과 분석을 위한 포장실험 연구)

  • Kim, Sung-Jae;Park, Tae-Yang;Kim, Sung-Min;Jang, Jeong-Ryeol;Kim, Sang-Min
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.4
    • /
    • pp.19-27
    • /
    • 2012
  • The objective of this study was to test the pollutant reduction effect by the silt fence and vegetated ridge through field monitoring. The experiment plots were established with two replication and three treatments. Each plot was designed with 5 m width, 22 m length, and 3 % slope. Flumes with the floating type stage gages were installed at the outlet of each plot to monitor the runoff. For a rainfall monitoring, tipping bucket rain gage was installed within the experiment site. Cultivated crops were spring daikon and autumn chinese cabbage. Analysis of variance (ANOVA) indicated that the water quality concentration from three experiment plots were not significantly different in 5 % of significant level. The monitoring results showed that the average pollution loads reduced by silt fence compared to control were SS 75.33 %, TN 40.87 %, TP 56.58 %, BOD 52.12 %, COD 36.07 %, TOC 34.99 %; by vegetated ridge compard to control were SS 65.27 %, TN 81.80 %, TP 54.26 %, BOD 67.09 %, COD 46.55 %, TOC 43.30 %. Analysis of Spearman's rank correlation coefficient showed that BOD-SS and SS-Turbidity were highly related at the silt fence and vegetated ridge plots. In all plots, SS-Turbidity and TP-TN relations were relatively high. The monitoring results showed that the silt fence and vegetated ridge were effect method to reduce the pollutant loads from the field runoff. Long-term monitoring is required to obtain more quantitative reduction effect for diverse crops and to increase the reliability of results.

Analysis on Landscape Characteristic of Entrance Spaces in the Apartment Complex - A case study of 'Award of Good Apartment to Living' in the Capital Region - (공동주택 아파트 진입부 경관특성 연구 - 수도권 '살기좋은 아파트 수상'단지를 중심으로 -)

  • Lee, Gyeong-Jin;Lee, Gi-Woo
    • KIEAE Journal
    • /
    • v.8 no.6
    • /
    • pp.47-55
    • /
    • 2008
  • The purpose of this study is as follows. 1) An element to organize the landscape of an apartment entrance space and setting up, a characteristic of landscape through the actual condition analysis. 2) The characteristic of the type analysis and classified the shape of the entrance as the type. 3) The degree to like the landscape analysis through the making up question. The result of this research is as follows. The entrance of the apartment complex of 71 as of 92 and set an element to organize the landscape and the characteristic of landscape through the frequency analysis and divided an entrance landscape of apartment into 4 types through the cluster analysis. An entrance landscape of apartment types of the entrance is classified as follows. 1) Type I: A model wall-fence type, 2) Type II: The side constructing a building-fence type, 3) type III: The side constructing a building-retaining wall-mixing tree type, 4) type IV: The moulding constructing a building-a retaining wall type.