• 제목/요약/키워드: Femoral fixation

검색결과 92건 처리시간 0.024초

실패한 족관절 인공관절 치환술 후 큰 골결손에서 내고정 없이 시행한 족관절 구제술: 증례 보고 (Ankle Salvage Procedure without Internal Fixation for Large Bone Defect after Failed Total Ankle Arthroplasty: A Case Report)

  • 박만준;은일수;정철용;고영철;류총일;김민우;황금민
    • 대한족부족관절학회지
    • /
    • 제18권2호
    • /
    • pp.76-79
    • /
    • 2014
  • In treatment of failure in ankle joint replacement therapy, talar avascular necrosis with massive bone defect, talus fracture with severe comminution and bone defect and ankle dislocation, treatment of large bone defects is considerably important for ankle joint stability and union, therefore, the choice of treatment for large bone defects is use of femoral head or iliac crest bone graft and rigid internal fixation. Because first generation total ankle arthroplasty performed for the first time using a cemented fixation technique requires a large amount of bone resection during re-surgery and there is some possibility of a larger bone defect after removal of implants, in cases where prosthesis for the defect is needed, performance of palliative femoral head or iliac crest bone graft and rigid internal fixation can be difficult. We report on a case of a 48-year-old woman who had experienced ankle pain for 25 years since undergoing total ankle arthroplasty. Because the patient had little ankle motion and rigid soft tissue despite a large bone defect caused by aseptic loosening, a good outcome was obtained only for the femoral cancellous bone graft using allo femoral head without internal fixation.

전방십자인대 재건술후 대퇴골 경골핀 고정의 실패 - 증례보고 - (Failure of Cross-Pin Femoral Fixation after Anterior Cruciate Ligament Reconstruction - A Case Report -)

  • 이기병;권덕주;지용남
    • 대한관절경학회지
    • /
    • 제7권1호
    • /
    • pp.92-95
    • /
    • 2003
  • 34세 남자 환자로 등산중 실족으로 발생한 전방십자인대의 완전파열로 자가 슬괵건을 이용한 경핀 고정법으로 전방십자인대 재건술을 시행하였다. 술후 경과는 양호하였으나 술후 3개월째 굴신 신전 운동 시 슬부 후측면의 동통과 지속적인 관절내 부종 소견을 보였으며 수차례의 관절천자와 약물투여에도 반응이 없었다. 컴퓨터 단층 촬영 상후방 피질 골의 천공이 관찰되어 술후 6개월째 이차관절내시경 수술을 시행하였다. 내시경 소견상 경핀고정물의 전방부 1/3에 일치되는 투명한 이물질과 대퇴경골관절면의 연골의 손상이 관찰되었으며 이물 제거 후 증세는 호전되었다. 경핀 터널의 잘못된 위치가 실패의 원인이라고 생각되었으며 경핀고정법을 이용한 전방십자인대 재건술시, 슬관절 과굴곡 상태에서 예각의 대퇴 터널을 만들어 후방 피질 골을 두껍게 남기고, 핀 홀을 만들 때 경핀가이드를 횡상과축보다 $10\~20$도 외회전시켜야 대퇴골 후방피질골의 천공을 방지할 수 있어 조기 실패를 예방할 수 있다고 생각된다.

  • PDF

Relevance of the Watson-Jones anterolateral approach in the management of Pipkin type II fracture-dislocation: a case report and literature review

  • Nazim Sifi;Ryad Bouguenna
    • Journal of Trauma and Injury
    • /
    • 제37권2호
    • /
    • pp.161-165
    • /
    • 2024
  • Femoral head fractures with associated hip dislocations substantially impact the functional prognosis of the hip joint and present a surgical challenge. The surgeon must select a safe approach that enables osteosynthesis of the fracture while also preserving the vascularization of the femoral head. The optimal surgical approach for these injuries remains a topic of debate. A 44-year-old woman was involved in a road traffic accident, which resulted in a posterior iliac dislocation of the hip associated with a Pipkin type II fracture of the femoral head. Given the size of the detached fragment and the risk of incarceration preventing reduction, we opted against attempting external orthopedic reduction maneuvers. Instead, we chose to perform open reduction and internal fixation using the Watson-Jones anterolateral approach. This involved navigating between the retracted tensor fascia lata muscle, positioned medially, and the gluteus medius and minimus muscles, situated laterally. During radiological and clinical follow-up visits extending to postoperative month 15, the patient showed no signs of avascular necrosis of the femoral head, progression toward coxarthrosis, or heterotopic ossification. The Watson-Jones anterolateral approach is a straightforward intermuscular and internervous surgical procedure. This method provides excellent exposure of the femoral head, preserves its primary vascularization, allows for anterior dislocation, and facilitates the anatomical reduction and fixation of the fracture.

슬괵건을 이용한 전방십자인대 재건술시 횡고정 핀과 간섭나사를 이용한 대퇴터널 고정술 -수술 수기- (Cross-Pin and Interference Screw Femoral Fixation in Anterior Cruciate Ligament Reconstruction using Hamstring Tendon -Technical Note-)

  • 인용;박원종;박종범;홍승환
    • 대한관절경학회지
    • /
    • 제6권1호
    • /
    • pp.60-63
    • /
    • 2002
  • 목적 : 네 겹의 슬괵건을 이용한 전방십자인대 재건술시 대퇴터널을 횡고정 핀과 흡수성 간섭나사로 함께 고정하는 수기를 소개하고자 한다. 수술 술기 : 반건양건과 박건을 채취하여 네 겹으로 준비하였다. 경골터널과 대퇴터널을 만드는데 대퇴터널의 깊이는 35 mm로 하였다. Rigidfix system의 가이드를 삽입하고 가이드의 위쪽 관에만 구멍을 내었다. 이식건을 통과시킨후 횡고정 핀 을 고정하였다. 이후 이식건을 경골쪽으로 당기면서 흡수성 간섭 나사로 고정하였다. 결론 : 슬괵건 전방십자인대 재건술시 횡고정 핀과 흡수성 간섭나사를 이용한 대퇴터널 고정은 강한 초기 고정과 이식건의 골통합을 촉진시킬 수 있는 좋은 방법으로 사료되어 소개하였다.

  • PDF

소아 대퇴골 경부골절의 임상적 고찰 (A Clinical Study on the Fractures of the Femoral Neck in Children)

  • 김세동;인주철
    • Journal of Yeungnam Medical Science
    • /
    • 제5권1호
    • /
    • pp.17-22
    • /
    • 1988
  • 1984년 6월 부터 1987년 8월까지 영남대학교 의과대학 부속병원 정형외과에서 체험한 9예의 대퇴골 결부골절에 대한 분석결과는 아래와 같다. 골절의 원인은 교통사고가 대부분(5예)이었으며, 성별로는 여자 6예, 남자 3예였다. 골절의 유형은 제 2형(transcervical)이 6예로 가장 많았다. 치료는 4예에서 도수정복후 내고정하였으며 3예에서는 관혈적정복 및 내고정했고, 2예에서 견인과 석고붕대 고정하였다. 치료결과는 6예에서 우수하였으나, 3예에서 불량하였다. 불량한 예는 모두 고관절, 대퇴경부 및 대퇴골두에 합병증이 생긴 경우였다. 교통사고 등 사고예방에 관심을 높여야 하고, 빠른 진단과 적절한 내고정방법들이 중요한 것으로 생각되었다.

  • PDF

Hybrid 대퇴 고정과 $Retroscrew^{(R)}$를 사용한 동종 경골건 이용 전방 십자 인대 재건술의 임상적 결과 (The Clinical Results of ACL Reconstruction with Tibialis Allograft Using Hybrid Femoral Fixation and $Retroscrew^{(R)}$)

  • 김두섭;라중호
    • 대한관절경학회지
    • /
    • 제13권1호
    • /
    • pp.8-13
    • /
    • 2009
  • 목적: 전방 십자 인대 재건술을 위해 동종 경골건을 이용하였고 대퇴 고정을 위해 $Endobutton^{(R)}$$Rigidfix^{(R)}$을 사용한 Hybrid 대퇴고정 그리고 경골 고정을 위해 $Retroscrew^{(R)}$ 및 추가 고정을 시행한 후 임상적 결과를 알아보고자 하였다. 대상 및 방법: 2004년 2월부터 2007년 2월까지 Hybrid 대퇴 고정과 $Retroscrew^{(R)}$를 이용한 전방 십자 인대 재건술을 시행하였고 1년 이상 추시(범위: 12~25개월) 가능 하였던 32명, 32례를 대상으로 하였다. 임상적 결과는 재건술 전후 Lysholm 슬관절 점수, IKDC 평가 기준, $Telos^{(R)}$ 전방 전위 검사를 이용하였고 최종 추시시 단순 방사선 전후면 및 측면 사진을 촬영하여 골 터널 확장 정도를 측정하였다. 결과: Lysholm 슬관절 점수는 술 전 평균 $67.9{\pm}5.4$점(범위: 51~77점)에서 최종 추시시 $94.1{\pm}6.8$점(범위: 68~98점)으로 유의하게 향상되었고(p<0.05) IKDC 최종 추시 평가상 정상(A) 22례(69%), 거의 정상(B) 9례(28%), 비정상(C) 1례(3%)로 심한 비정상(D)을 보이는 경우는 없었다. $Telos^{(R)}$ 스트레스 부하 방사선 검사상 건측과의 차이가 술 전 평균 $13.2\;mm{\pm}5.8$(범위: 6~21 mm)에서 술 후 평균 $3.4\;mm{\pm}2.8$(범위: 0~11 mm)로 유의하게 호전되었다(p<0.05). 골 터널 확장은 대퇴 터널은 전후면 사진상 18.7%, 측면 사진상 12.4%(p<0.05), 경골 터널은 전후면 사진상 9.6%, 측면 사진상 8.5%의 확장을 보였다(p<0.05). 그러나 골 터널 확장의 정도와 슬관절 기능 사이에는 통계학적 유의성을 보이지 않았다(p>0.05). 결론: 동종 경골건의 고정시 Hybrid 대퇴고정과 $Retroscrew^{(R)}$를 이용한 전방 십자 인대 재건술은 이식건의 해부학적 고정을 가능하게 하였고 임상적으로 우수한 결과를 보였다.

  • PDF

Evaluation of the Femoral Stem Implant in Canine Total Hip Arthroplasty: A Cadaver Study

  • Cho, Hyoung Sun;Kwon, Yonghwan;Kim, Young-Ung;Kang, Jin-Su;Lee, Kichang;Kim, Namsoo;Kim, Min Su
    • 한국임상수의학회지
    • /
    • 제36권1호
    • /
    • pp.53-61
    • /
    • 2019
  • Total hip arthroplasty (THA) is a successful surgical treatment for both patients with chronical lameness and dogs who are nonresponsive to medical treatments, providing excellent joint function for returning dogs to the normal gait in 80% to 98% of hip dysplasia (HD) patients. The THA surgical implant system manufactured by BioMedtrix and Kyon are today widely accepted. When comparing the BioMedtrix biological fixation (BFX) system to the BioMedtrix cemented fixation (CFX) system, the many advantages of BFX, which include longer potential implant life, decreased risk of postoperative or later infection, and better implant stability, become evident. However, BFX implies a greater risk of femoral fracture during reaming and requires a more precise surgical technique to achieve good implant fit, given the press-fit nature of cementless THA. The purposes of this study are to both describe the mistakes and complications during stem implantation for beginner surgeons with both the BFX and the CFX systems and to document the initial result of 12 implantations in canine cadavers. Given the detailed evaluations of 3 specialists, who are Diplomate American College of Veterinary Surgeons (DACVS), only 3 of 11 stems were appropriately sized. Specifically, 6 stems were anteverted rather than being retroverted; further, although 7 stems were coaxial with the femoral long axis in the frontal plane, the other stems were in the varus at the frontal plane, with the proximal medial stem adjacent to the medial femoral cortex. Moderate angulation from the cranial to the caudal directions was found in 4 cases in the sagittal plane. Additionally, 1 case of femoral fissure and 1 case of perforated femoral cortex were reported. It is not easy for surgeons performing cementless THA for the first time to achieve a good result, even though they completed an educational course about it and given that catastrophic complications often occurred during early surgical clinical cases. Therefore, ex-vivo studies are sincerely required to get an expertise by rehearsing the preparation of the femoral envelop in isolated bones. Further studies should be conducted to achieve both highly accurate implant size and correct orientation during the preoperative planning. Additionally, surgeons' learning curve should be examined in future investigations.

TransFix 경골부 고정을 이용한 경 경골 두 다발 후방십자인대 재건술 - 수술 술기 - (Transtibial Double Bundle PCL Reconstruction using TransFix Tibial Fixation - Technical Note -)

  • 이용석;정영복;안진환;강번중;신윤창;공제관
    • 대한관절경학회지
    • /
    • 제10권2호
    • /
    • pp.203-208
    • /
    • 2006
  • 목적: 후방십자인대의 경 경골 두 다발 재건술에 있어서 기존의 방법들은 공여 인대가 길어야 하는 문제 때문에 이식건의 선택이 제한적인 경우가 많으며 경골부에서 이중의 고정을 해야 하는 문제점 등이 있다. 이에 저자들은 두 다발 재건술을 실시하면서 경골부에서 초기에 단일 고정으로써 안정성을 얻고, 공여 인대 길이에 제한을 덜 받는 방법을 소개하고자 한다. 수술 술기: 진단적 관절경 검사를 실시 한 후 두 다발 재건술을 위한 이식건을 준비하고, 경골 터널 및 TransFix 고정을 위한 준비를 한다. 대퇴부에 2개의 터널을 만들고, 이식건을 전 내측 입구를 이용하여 경골부, 대퇴부 순으로 통과시킨 후 TransFix를 이용하여 경골부에 고정을 먼저 실시하고, 대퇴부의 2 다발을 각각의 고정 위치에서 고정을 실시한다. 결론: 경경골 터널을 이용한 두 다발 후방십자인대 재건술에서 TransFix를 이용한 경골부의 고정은 단일 고정으로써 강한 고정을 제공하면서 이식건의 길이에 제한을 받지 않고, 전 내측 입구로 이식건을 통과시킴으로써 이식건의 손상을 방지할 수 있는 좋은 방법이라고 생각한다.

  • PDF

Risk Factors Associated with Fixation Failure in Intertrochanteric Fracture Treated with Cephalomedullary Nail

  • Hyung-Gon Ryu;Dae Won Shin;Beom Su Han;Sang-Min Kim
    • Hip & pelvis
    • /
    • 제35권3호
    • /
    • pp.193-199
    • /
    • 2023
  • Purpose: Cephalomedullary (CM) nailing is widely performed in treatment of elderly patients with femoral intertrochanteric fractures. However, in cases of fixation failure, re-operation is usually necessary, thus determining factors that may contribute to fixation failure is important. In this study, we examined factors affecting the occurrence of fixation failure, such as age or fracture stability, after CM nailing in elderly patients. Materials and Methods: This study was conducted retrospectively using registered data. From April 2011 to December 2018, CM nailing was performed in 378 cases diagnosed with femoral intertrochanteric fractures, and 201 cases were finally registered. Cases involving patients who were bed-ridden before injury, who died from causes unrelated to surgery, and those with a follow-up period less than six months were excluded. Results: Fixation failure occurred in eight cases. Comparison of the surgical success and fixation failure group showed that the mean age was significantly higher in the fixation failure group compared with the control group (81.3±6.4 vs. 86.4±6.8; P=0.034). A significantly high proportion of unstable fractures was also observed (139/54 vs. 3/5; P=0.040), with a significantly high ratio of intramedullary reduction (176/17 vs. 5/3; P=0.034). A significantly higher ratio of unstable fractures compared with that of stable fractures was observed in the intramedullary reduction group (132/49 vs. 10/10; P=0.033). Conclusion: Fixation failure of CM nailing is likely to occur in patients who are elderly or have unstable fracture patterns. Thus, care should be taken in order to avoid intramedullary reduction.

유한요소법을 이용한 인공고관절 주대형태의 개선에 대한 연구 (A Study for Improvement of the Femoral Stem Type using the Finite Element Analysis)

  • 윤경렬;원예연;이수훈
    • 한국CDE학회논문집
    • /
    • 제5권2호
    • /
    • pp.122-126
    • /
    • 2000
  • A major mechanical problem with total hip replacement is the loosening of the femoral component. The loss of proximal support, with firm fixation distally, has been thought to be a major caused of fatigue failure of femoral stems. While many causes have been proposed, the most frequently suggested cause of the calcar resorption is the disuse atrophy of the cortex of the calcar due to the stress shielding of the proximal bone by the metal femoral stem. In this research, the new-designed stem(modified collar stem) was considered which made a hole inside stem and had a 3 mm thickness. Using the 3-dimensional finite element methods, the common collar stem and the modified colla stem was modeled and analysed. Also, the two models was compared. The results showed that the modified collar stem decreased the stress-shielding and it made a effective load transfer at the entire femoral region.

  • PDF