• 제목/요약/키워드: Femoral bone model

검색결과 59건 처리시간 0.031초

측면낙상 시뮬레이션용 대퇴골 모델 개발에 관한 연구 (Development of Femoral Bone Model of Human Body for Simulation of Side Falls)

  • 박지수;구상모;김충현
    • 전기학회논문지
    • /
    • 제63권7호
    • /
    • pp.956-961
    • /
    • 2014
  • Due to the increasing needs of anti-fall device for elderly, it is required to develop the test rigs for fall simulation. The femoral bone model consists of silicone and steel is used as an effective device to simulate falls. In this work, we propose five different femoral bone models and analyse them by using a commercial FEA tool. It has been shown that two kinds of simplified models exhibit the simulated side falls with an error range of ~1% in the impact load of femoral neck compared with full model. Especially, the upper tissue model is found to provide us with the best efficient test environment, attributable to its simple structure.

Oblique Single-Cut Rotation Osteotomy for Correction of Femoral Varus-Torsional Deformities in 3D-Reconstructed Canine Bone Models

  • Kim, Hyeon-Ho;Roh, Yoon-Ho;Lee, Je-Hun;Jeong, Jae-Min;Jeong, Seong Mok;Lee, Hae Beom
    • 한국임상수의학회지
    • /
    • 제37권4호
    • /
    • pp.180-184
    • /
    • 2020
  • The purpose of this study was to report the reliability and validity of oblique single-cut rotation osteotomy (OSCRO) in 3D-reconstructed canine bone models with femoral varus and torsional deformities. A healthy adult male beagle was recruited to create a 3D bone model, and this bone model was modified by using a 3D program. Fifteen bone models were constructed for this study. OSCRO simulation was performed in accordance with the plan after printing using a 3D printing machine. The anatomical lateral distal femoral angle (aLDFA), anteversion angle (AA), anatomical caudo-distal femoral angle (aCdDFA), mechanical caudo-distal femoral angle (mCdDFA) and pre- and postoperative bone length were calculated. There were no significant differences between the target values and postoperative values. In addition, the difference between pre- and postoperative bone length was small (p = 0.001). Our findings suggest that OSCRO could be an effective surgical option for MPL with bone deformities in small-breed dogs that often undergo conventional distal femoral osteotomy.

Approximated 3D non-homogeneous model for the buckling and vibration analysis of femur bone with femoral defects

  • Mobasseri, Saleh;Sadeghi, Mehdi;Janghorban, Maziar;Tounsi, Abdelouahed
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • 제5권1호
    • /
    • pp.25-35
    • /
    • 2020
  • We carry the knowledge that the skeleton bones of the human body are not always without defects and some various defects could occur in them. In the present paper, as the first endeavor, free vibration and buckling analysis of femur bones with femoral defects are investigated. A major strength of this study is the modeling of defects in femur bones. Materialise Mimics software is adopted to model the bone geometry and the SOLIDWORKS software is used to generate the defects in bones. Next, the ABAQUS software is employed to study the behaviors of bones with defects.

전기자극이 개의 대퇴골절 치유에 미치는 영향 (Effects of Electrical Stimulation on Femoral Fracture Healing in a Dog Model)

  • 박경철;이주명;윤영민;강태영;김희석;이경갑;강윤호;정종태
    • 한국임상수의학회지
    • /
    • 제20권3호
    • /
    • pp.328-333
    • /
    • 2003
  • This study was performed to investigate the effects of electrical stimulation on femoral fracture healing in dogs. Eight healthy dogs from 4 to 5 $\beta^3$ were used in this experiment. In the treatment group, anode and cathode were connected to proximal and distal site apart from the fracture line by 2 cm and electrical stimulation was applied to the fracture site for l5minutes by 2 V, 25 Hz and for a month. The control group was connected to electrostimulator as the treatment group, but no electrical stimulation was applied. Various parameters were evaluated including radiograph and serum levels of total-ALP(TALP), bone-ALP(BALP) and osteocalcin. The radiography revealed more rapid callus formation in the treatment group than in the control by about a week. The total-ALP levels of the treatment group were higher than those of the control group from the 2nd to the 24th day(p< 0.05). The bone-ALP levels of the treatment group were significantly higher than those of the control from the 2nd to the 24th day(p< 0.05). The bone-ALP/ total-ALP ratios of the treatment group were higher than those of control throughout this experiment but there were no significance. There were no significance in the osteocalcin levels between two groups. In conclusion, the electrical stimulation on femoral fracture site was effective for bone healing in dogs.

Mice에서 Calcein 표지를 이용한 골 변화 관찰 (Bone Changes in Femoral Bone of Mice Using Calcein Labeling)

  • 심문정
    • 대한임상검사과학회지
    • /
    • 제48권2호
    • /
    • pp.114-117
    • /
    • 2016
  • 골은 일생에 걸쳐 지속적인 재형성과장을 거치면서 유지되고 이러한 기전에 대한 연구는 골다공증을 비롯한 골대사 질환의 병태생리와 치료에 있어 큰 진전을 이루고 있다. 특히 생체 내 골형성 및 재생과정을 연구하는데 있어 형광표지자를 이용하는 방법이 널리 알려져 있는데, 그 중 calcein은 칼슘 킬레이터로 골이 새롭게 형성하는 부위에 녹색을 띔으로써 유용한 마커로 사용된다. 그러나 대부분의 골형성 연구에서 실험동물의 경우 표본제작을 할 때 크기가 작고 뼈가 부숴지기 쉬워 rat이나 rabbit을 이용하였으며, mice의 femur를 cross-section해서 관찰한 연구는 거의 없는 실정이다. 그래서 본 연구에서는 어린 mice를 실험동물로 이용하였으며, 생체 내 calcein을 4주간, 8주간 투여한 후 골 형성 변화를 형광현미경으로 관찰한 결과 8주차 쥐에서 4주차보다 진하고 골 형성 간격도 넓게 관찰된 것을 확인 할 수 있었다. Mice는 빠른 시일 내에 결과를 얻을 수 있고 부작용이 적은 장점이 있어서 앞으로 knock-out mice를 이용한 생체 내 실험에 활용하기 적합하다고 생각되며, 골형성 속도 평가 등 다양한 분야에서의 골 형성과 재생연구에 있어 기초 정보를 제공할 것으로 기대한다.

대퇴골두 무혈성 괴사증의 수술적 기법 적용 후 괴사 망상골 내에서의 응력 변화 해석 (An Analysis of Stress Transfer Behaviors within the Necrotic Cancellous Bone following Surgical Procedures or the Management of the Osteonecrosis of the Femoral Head)

  • 정성;이성재
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.245-248
    • /
    • 1997
  • Operative interventions for the management of osteonecrosis of the femoral head (ONFH) include core drilling, with or without vascularized fibular bone grafting. Nevertheless, their clinical results have not been consistently satisfactory. Recently, a new surgical procedure that incorporates cementation with polymethylmethacrylate (PMMA) after core drilling has been tried clinically. In this study, a biomechanical analysis using a finite element method(FEM) was undertaken to evaluate surgical methods and their underlying surgical parameter. Our finite element models included five types. They were (1) normal model (Type I), (2) necrotic model (Type II), (3) core decompressed model (Type III). (4) fibular bone grafted model (Type IV), and (5) cemented with PMMA model (Type V). The geometric dimensions of the femur were based on digitized CT-scan data of a normal person. Various physiological loading conditions and surgical penetration depths by the core were used as mechanical variables to study their biomechanical contributions in stress transfer within the femoral head region. In addition. the peak von Mises stress(PVMS) within the necrotic cancellous bone of the femoral head was obtained. The fibular bone grafted method and cementation method provided optimal stress transfer behaviors. Here. substantial increase in the low stress level was observed when the penetration depth was extended to 0mm and 5mm from the subchondral region. Moreover, significant decrease in PVMS due to surgery was observed in the fibular bone grafted method and the cementation method when the penetration depths were extended up to 0 and 5mm from the subchondral region. The drop in PVMS was greater during toe-off than during heel-strike (57% vs. 28% in Type IV and 49% vs. 22% in Type V). Both the vascularized fibular bone grafting method (Type IV) and the new PMMA technique (Type V) appear to be very effective in providing good stress transfer and reducing the peak Von-Mises stress within the necrotic region. Overall results show that fibular bone grafting and cementation methods are quite similar. In light of above results, the new cementation method appears to be a promising surgical alternative or the treatment of ONFH. The use of PMMA for the core can be less prone to surgical complication as opposed to preparation of fibular bone graft and can achieve more immediate fixation between the core and the surrounding region.

  • PDF

대퇴골두 해면골의 미세구조 특성과 기계적 특성의 분석 (Analysis of the Micro-Structural and Mechanical Properties in Human Femoral Head Trabecular Bone with and without Osteoporosis)

  • 원예연;백명현;최문권;전경진;김만경
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권6호
    • /
    • pp.519-523
    • /
    • 2004
  • 골다공증이 있는 대퇴골두 해면골과 골다공증이 없는 대퇴골두 해면골의 특성을 평가하고자 미세단층촬영기 및 유한요소모델을 이용하여 해면골을 미세구조 특성과 기계적 특성을 비교 및 분석하였다. 골다공증이 있는 대퇴골두는 골밀도를 측정하여 T-score 값이 -2.5 이상인 시편 15개를 사용했으며, 골다공증이 없는 대퇴골두는 사망전 골다공증으로 인한 병력이 없었던 사체 4구에서 대퇴골두 5개를 획득하여 사용하였다. 대퇴골두 해면골의 미세구조 특성을 분석하기 위해서 미세단층촬영기를 이용하여 골다공증이 있는 대퇴골두와 골다공증이 없는 대퇴골두를 촬영하여 형태학적 지수(histomorphometry index)를 구했고, 미세단층촬영기에 의해서 획득된 미세영상(pixel size=21.31㎛)을 바탕으로 유한요소모델을 재건하여 기계적 특성을 구하였다. 형태학적지수는 골다공증이 없는 대퇴골두가 골다공증이 있는 대퇴골두에 비해서 골소주 두께, 골 체적, 골 체적비, 이방성 정도 그리고 골소주 개수가 증가했으며, 골소주 간격과 구조모델지수는 감소했다. 기계적특성 지수는 골다공증이 없는 대퇴골두 해면골 시편에서 반력, 표면응력 그리고 영률이 높게 분석되었다. 골다공증이 있는 대퇴골두 해면골 시편에서 미세구조 특성이 퇴화되며, 기계적 특성이 감소된다는 사실을 알수 있었다.

Fermented soybeans by Rhizopus oligosporus reduce femoral bone loss in ovariectomized rats

  • Yoo, Hyun-Wook;Chang, Moon-Jeong;Kim, Sun-Hee
    • Nutrition Research and Practice
    • /
    • 제8권5호
    • /
    • pp.539-543
    • /
    • 2014
  • BACKGROUND/OBJECTIVES: Soy isoflavones are structurally similar to estrogen and bind to estrogen receptors, suggesting that they exhibit estrogenic activities; therefore, they are referred to as phytoestrogens. Fermentation may affect the bioavailability of isoflavones altering soy isoflavone glycosides in the form of aglycones. Thus, this study investigated the effects of fermented soybeans by Rhizopus oligosporus on bone metabolism in both young rats as a pilot test and in ovariectomized (ovx) old rats as a model of menopause. MATERIALS/METHODS: In the pilot test, a total of 24 seven-week-old female Sprague-Dawley (SD) rats were fed one of three diets for a period of four weeks: casein, unfermented soybean product, or fermented soybean product by R. oligosporus. In the ovx rat model, 20-week-old SD rats weighing 260-290 g underwent either sham-operation (n = 10) or bilateral ovariectomy (n = 30) and were then fed the AIN-93M diet for one week. Thereafter, rats were fed sham-casein, ovx-casein, ovx-soybean, or ovx-fermented soybean diet for five weeks. After decapitation, femoral bones were isolated and preserved in 9% formalin for assessment of bone mineral density (BMD), bone mineral content (BMC), and bone-breaking strength (BBS). RESULTS: Ovx rats showed significantly increased weight gain and decreased uterine wet weight. Of particular interest, ovx rats fed fermented soybeans showed increased uterine wet weights compared to control rats. Fermented soybean diet caused a significant increase in plasma 17-${\beta}$ estradiol concentrations in young rats, and 17-${\beta}$ estradiol levels were enhanced in ovx rats to match those of sham-operated ones. Significantly lower femoral BMD and BMC were observed in ovx rats compared to sham-operated controls, whereas bone areas did not differ statistically among the groups. In addition, BBS tended to be increased in ovx rats fed soybeans and fermented soybeans. CONCLUSIONS: Supplementation of fermented soybeans could have preventive and therapeutic effects against osteoporosis in postmenopausal women.

인공고관절 골흡수로 인한 응력분포 변화의 2차원 유한요소 해석 (Two-Dimensional Finite Element Analysis of Bone Resorption from the Artificial Hip Replacement)

  • 최형연;채수원;김성곤
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권1호
    • /
    • pp.25-32
    • /
    • 1995
  • Clinically, proximal bone resorption in the femur is frequently seen postoperatively on the follow up XI-rays after total hip replacement (THR). We developed the finite element model of cementless THR. The model is two dimensional side plate model, whereby the three dimensional structural integrity of the bone can be accounted for by a separate two dimensional mesh, a side plate. The subject of this article is the development and application of this two dimensional side plate FEM to study the reverse effect of the various degree of bone resorption of femur after THR. The results of this study indicates that 1) two dimensional side plate model is good and simple alternative to complex three dimensional model and 2) the severity of the proximal bone resorption has the effect of more increasing stress on the cortex at the level of femoral stem tip.

  • PDF

무시멘트형 인공고관절 대치술후 초기의 경계면 미세운동의 3차원 FEM 연구 (A Study on the Interface Micromotions of Cementless Artificial Hip Replacement by Three-Dimensional FEM)

  • 김성곤;채수원;최형연
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1994년도 추계학술대회
    • /
    • pp.71-74
    • /
    • 1994
  • In cementless total hip arthroplasty(THA), an initial stability of the femoral component is mandatory to achieve bony ingrowth and secondary long term fixation. Bone ingrowth depends strongly on relative micromotion and stress distributions at the interface. Primary stability of the femoral component can be obtained by minimizing the magnitude of relative micromotions at bone-prosthesis interface, Hence an accurate evaluation of interface behavior and stress/strain fields in the bone implant system may be relevant for better understanding of clinical situations and improving THA design. However, complete evaluation of load transfer in the bone remains difficult to assess experimentally, Hence, recently finite element method (FEM) was introduced in orthopaedic research field to fill the gap due to its unique capacity to evaluate stress in structure of complex shape, loading and material behavior. The authors developed the 3-dimensional numerical finite element model which is composed of totally 1179 elements off and 8 node blick. We also analyzed the micromotions at the bone-stem interface and mechanical behavior of existing bone prosthesis for a loading condition simulating the single leg stance. The result indicates that the values of relative motion for this well fit Multilock stem were $150{\mu}m$ in maximum, $82{\mu}m$ in minimum, and the largest relative motion developed in medial region of proximal femur with anterior-posterior direction. The proximal region of the bone was much larger in motion than the distal region and the stress pattern shows high stress concentration on the cortex near the tip of the stem. These findings indicates that the loading in the proximal femoral bone in the early postoperative situation can produce micromotions on the interface and clinically cementless TEA patient should not be allowed weight bearing strictly early in the postoperative period.

  • PDF