• 제목/요약/키워드: Feeding System

Search Result 1,543, Processing Time 0.042 seconds

Analysis of Voltage Drop under Extended Feeding in KyungBu High Speed Line (II) (경부고속선의 전력공급 안정성 검토를 위한 연장급전 조건의 전압강하 검토 (II))

  • Kim, Joo-Rak;Chang, Sang-Hoon;Park, Hyun-June;Lee, Young-Heum
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1984-1990
    • /
    • 2011
  • This paper presents the simulation of traction power supply system for the evaluation of voltage drop in Kyungbu high speed line. This simulation is performed in circumstance of extended feeding through vicinity substation. Extended feeding should be considered from design of system. Therefore, voltage drop at extended feeding must be accepted against regulation. In this paper, voltage drop is evaluated under condition of extended feeding targeting section from Shinchungju and Pyungtaek S/S.

  • PDF

Analysis of Catenary impedance characteristics in the extended power feeding conditions of AC traction system (교류급전방식에서의 연장급전에 따른 선로임피던스 특성 분석)

  • Jung, Hosung;Kim, Joorak;Chang, Sanghoon
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1617-1618
    • /
    • 2015
  • This paper analyzed catenary impedance characteristics of relays installed in substation and sectioning post to protect power feeding circuit in the extended power feeding conditions. For this, we modelled AT feeding system using PSCAD/EMTDC and calculated catenary impedance. The relay installed in substation calculated catenary impedance of the extended power feeding area adding catenary impedance of self protection zone. But, the relay installed in sectioning post calculated catenary impedance of the only protection area. Therefore, we confirmed that the more reliable protection way can be utilized using the relay installed in sectioning post.

  • PDF

Autonomous Feeding Robot and its Ultrasonic Obstacle Classification System (자동 사료 급이 로봇과 초음파 장애물 분류 시스템)

  • Kim, Seung-Gi;Lee, Yong-Chan;Ahn, Sung-Su;Lee, Yun-Jung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.8
    • /
    • pp.1089-1098
    • /
    • 2018
  • In this paper, we propose an autonomous feeding robot and its obstacle classification system using ultrasonic sensors to secure the driving safety of the robot and efficient feeding operation. The developed feeding robot is verified by operation experiments in a cattle shed. In the proposed classification algorithm, not only the maximum amplitude of the ultrasonic echo signal but also two gradients of the signal and the variation of amplitude are considered as the feature parameters for object classification. The experimental results show the efficiency of the proposed classification method based on the Support Vector Machine, which is able to classify objects or obstacles such as a human, a cow, a fence and a wall.

Analysis of Voltage Stability in Electric Railway Feeding System (전기철도 급전계통의 집전전압 안정도 해석)

  • Lee Chang-Mu;Lee Han-Min;Han Moon-Seob;Kim Joo-Rak;Jung Ho-Seong
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1384-1389
    • /
    • 2004
  • The primary objective of this paper is to examine the capacity of electrical transmission in electric railway feeding system. Although supply capacity of railway substation are sufficient and there is no accident, due to the electrical transmission limit of feeding line the voltage breakdown may occur when large capacity of electric load at feeding line exist. So, using multi-port analysis model, we draw P-V curve due to the length of feeding line, load, location and power factor of electric locomotive. And through case study, compare measurement result and simulation result

  • PDF

Development of intelligent coagulant feeding system (지능형 응집제 투입 시스템의 개발)

  • Chung, Woo-Seop;Oh, Sueg-Young
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.6
    • /
    • pp.652-658
    • /
    • 1997
  • Coagulant feeding control is very important in the water treatment process. Coagulant feeding is related to the raw water quality such as turbidity, alkalinity, water temperature, pH and so on. However, since the process of chemical reaction has not been clarified so far, coagulant dosing rate has been decided by jar-test. In order to overcome the difficulty mentioned above, Fuzzy Neural Network to fuse fuzzy logic and neural network was proposed, and the scheme was applied to the automatic determination of coagulant dosing rate. This algorithm can automatically identify the if-then rules, tune the membership functions by utilizing expert's experimental data. The proposed scheme is evaluated by computer simulation and interfaced with coagulant feeder operated by magnetic flowmeter, control valve and PLC. It is shown that coagulant feeding according to real time sensing of water quality is very effective.

  • PDF

Relation between Induced Voltage of Rail and Feeding Line of Wireless Power Transfer System for Railway Application (철도용 무선전력전송시스템의 급전선로와 레일유기전압의 관계)

  • Kim, JaeHee;Park, Chan-Bae;Jung, Shin-Myung;Lee, Seung-Hwan;Lee, Byung-Song;Lee, Jun-Ho;Lee, Su-Gil
    • Journal of the Korean Society for Railway
    • /
    • v.17 no.4
    • /
    • pp.228-232
    • /
    • 2014
  • The magnetic field generated by the feeding line of a wireless power transfer system induces voltage on the rail of a railway system. The induced voltage of the rail can have a bad influence on the track circuit and on safety. This paper simulated three feeding lines to study the relation between the feeding lines and the induced voltage of the rail; it also proposed magnetic field distribution of the feeding line to reduce the induced voltage.

A Study on the Voltage Drop and Earth Leakage Current according to Interval of AT in the AT Feeding Method (AT급전방식에서 AT간격에 따른 전압강하 및 대지누설전류에 대한 연구)

  • Kim, Min-Seok;Choe, Seung-Hyuk;Lee, Jong-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.9
    • /
    • pp.1708-1714
    • /
    • 2011
  • AT feeding system of the electric railway system is installed every about 10km at between the feeder and catenary in parallel and the mid-point of the transformer is connected to the rail The supply voltage of this system is doubled than rolling stock voltage. So the voltage drop is smaller than usual. And the other merit of this system is the decreasing inductive disturbance to the communication line because of the reduced current in rail which runs reversed in a point of view of rolling stock. Also, ATP(Auto Transformer Post) is installed to reduce the voltage drop and to mitigate the inductive disturbance, but still now the proper distance between the ATP and AT feeding system is not established which ranges from 2 to 10[km]. The stable result of simulation(which is set that the end of the line AT is installed) to the voltage drop and inductive disturbance can not analyzes the effect to the supply system due to the ATP. This paper analyzes the effect to the system depending on the location of ATP by forecasting the voltage drop and inductive disturbance.

A Study on the Architectural Planning of a Maternity Ward Focused on Rooming-in System (모자동실 개념을 중심으로 한 산과 병동의 건축계획에 관한 연구)

  • Kim, Eon-Hwa;Yu, Young-Min
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.8 no.2
    • /
    • pp.25-33
    • /
    • 2002
  • The effects and necessity of the breast milk are well known, but the breast-feeding rate in our country is very low. One of the reason is due to the separation policy of mother and baby after delivery. The mother is in the inpatient-room and the baby is in the new-born baby room. This isolation operation of hospital get increased according to the decreasing ratio of breast feeding in Korea. Only a few hospital operates and provides the space for a new-born baby in the mother's room. The system of baby and mother in one room is adopted and operated due to the breast feeding campaign. It is very encouraging, but the space for the baby and the mother is not enough in multi-bed rooms. We should reconsider the relationship between the new-born baby unit and the obstetric ward, and design the patient's room for the baby and the mother.

  • PDF

An analysis of the power quality problem at an electric train according to dead section (절연구간 통과시 전기철도 차량에 유입되는 전력 품질 분석)

  • Lee, Bong-Yi;Kim, Jae-Chul;Moon, Jong-Fil;Han, Seong-Ho;Lee, Su-Gil
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.51-53
    • /
    • 2005
  • At the railway feeding system, a role of dead section is very important. Because, dead section is essential installation that AC feeding system meets DC feeding system or phase is changed between AC feeding systems. But, in dead section it is possible that an electric train meets interruption. In Korea, a study on the dead section isn't yet accomplished in depth. Accordingly. In this paper, when electric train is in dead-section power quality problem on electric train was dealt. Modeling and simulation using PSCAD/EMTDC was accomplished to analyze.

  • PDF

Determination of dosing rate for water treatment using fusion of genetic algorithms and fuzzy inference system (유전알고리즘과 퍼지추론시스템의 합성을 이용한 정수처리공정의 약품주입률 결정)

  • 김용열;강이석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.952-955
    • /
    • 1996
  • It is difficult to determine the feeding rate of coagulant in water treatment process, due to nonlinearity, multivariables and slow response characteristics etc. To deal with this difficulty, the fusion of genetic algorithms and fuzzy inference system was used in determining of feeding rate of coagulant. The genetic algorithms are excellently robust in complex operation problems, since it uses randomized operators and searches for the best chromosome without auxiliary information from a population consists of codings of parameter set. To apply this algorithms, we made the look up table and membership function from the actual operation data of water treatment process. We determined optimum dosages of coagulant (PAC, LAS etc.) by the fuzzy operation, and compared it with the feeding rate of the actual operation data.