• Title/Summary/Keyword: Feeder Automation System

Search Result 66, Processing Time 0.029 seconds

Load Flow Analysis for Distribution Automation System based on Distributed Load Modeling

  • Yang, Xia;Choi, Myeon-Song;Lim, Il-Hyung;Lee, Seung-Jae
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.3
    • /
    • pp.329-334
    • /
    • 2007
  • In this paper, a new load flow algorithm is proposed on the basis of distributed load modeling in radial distribution networks. Since the correct state data in the distribution power networks is basic for all distribution automation algorithms in the Distribution Automation System (DAS), the distribution networks load flow is essential to obtain the state data. DAS Feeder Remote Terminal Units (FRTUs) are used to measure and acquire the necessary data for load flow calculations. In case studies, the proposed algorithm has been proven to be more accurate than a conventional algorithm; and it has also been tested in a simple radial distribution system.

CIM based Distribution Automation Simulator (CIM 기반의 배전자동화 시뮬레이터)

  • Park, Ji-Seung;Lim, Seong-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.3
    • /
    • pp.87-94
    • /
    • 2013
  • The main purpose of the distribution automation system (DAS) is to achieve efficient operation of primary distribution systems by monitoring and control of the feeder remote terminal unit(FRTU) deployed on the distribution feeders. DAS simulators are introduced to verify the functions of the application software installed in the central control unit(CCU) of the DAS. Because each DAS is developed on the basis of its own specific data model, the power system data cannot be easily transferred from the DAS to the simulator or vice versa. This paper presents a common information model(CIM)-based DAS simulator to achieve interoperability between the simulator and the DASs developed by different vendors. The CIM-based data model conversion between Smart DMS (SDMS) and Total DAS (TDAS) has been performed to establish feasibility of the proposed scheme.

Development of Feeder Automation Software Considering the Diversity Events of Distribution System (배전계통의 다양한 이벤트들을 고려한 선로자동화 소프트웨어 개발)

  • Ko, Yun-Seok;Kim, Yun-Jib;Bak, Young-Gu;Lee, Kee-Seo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.307-309
    • /
    • 2002
  • This paper proposes an expert system, which is able to determine the problem-solving strategy for diversity events occurred on the distribution system. The events include events related to the fault, scheduled outage and optimal operating task such as feeder line fault, line scheduled outage, line overload, system load balancing, system loss minimization, main transformer fault, main transformer scheduled outage, main transformer overload, main transformer protection control. The expert system enhances the reliability of software designed by the integrated concept for the diversity events.

  • PDF

A Fault Section Detection Method for Ungrounded System Based on Phase Angle Comparison of Zero-Sequence Current (비접지 배전계통에서 영상전류 위상 비교에 의한 고장구간 검출 방법)

  • Yang, Xia;Choi, Myeon-Song;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.31-32
    • /
    • 2007
  • In this paper, a fault section detection method is proposed for ungrounded system in the case of a single line-to-ground fault. A conventional method is used for faulted feeder selection according to the angular relationship between zero-sequence currents of the feeders and zero-sequence voltage of the system. Fault section detection is based on the comparison of phase angle of zero-sequence current. Proposed method has been testified in a demo system by Matlab/Simulink simulations. Based on Distribution Automation System(DAS), Feeder Remote Terminal Unit(FRTU) is used to collect those necessary data, at present a demo system is under developing using Manufacturing Message Specification (MMS) in IEC61850 standard.

  • PDF

The result on field test of distribution automation in distribution test center (배전 실증시험장에서의 배전자동화 실증시험 결과)

  • Ha, Bok-Nam;Yoon, Tae-Sang;Jeong, Yeong-Ho;Cho, Nam-Hun;Lim, Seong-Il;Kang, Moon-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.182-184
    • /
    • 2000
  • There are several facilities in Kochang distribution test center such as artificial fault generator(AFG), new distribution automation system(NDAS), communication networks (wireless and optic), lumped constant circuit, switches for distribution automation, overhead and underground distribution line. We have been field testing on remote control, data acquisition. remote metering, feeder automation and so on for distribution automation using those equipment.

  • PDF

Ananalzing fault current and Protective coordination in the underground line (지중배전선로의 고장전류 크기 및 보호협조분석)

  • Cho, Nam-Hun;Ha, Bok-Nam;Lee, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.932-934
    • /
    • 1998
  • Electric power distribution feeders are susceptible to faults caused by a variety of situations such as adverse weather conditions, tree contacts, equipment failure, accidents, etc. Distribution circuit faults result in a number of problems related to the reliability of service and customer power quality. In the past, the permanent interruption of customer service resulting from a blown fuse or a recloser lockout was the only factor which was used to determine service reliability. So we developed KODAS(Korea Distribution Automation System) with successful and had fieid-testing of Distribution Automation System in last three years at Kang-dong Branch Office. In performing the project, KEPRI has gained valuable experience, through dealing with many difficult problem. This paper is depicted about the circuit breaker coordination problems in the Underground for the Distribution Automation Feeder.

  • PDF

Auto Welding System Development For The Improvement Of The Stud Bolt Welding System (Stud Bolt 용접 환경 개선을 위한 자동 용접 시스템 개발)

  • 하인철;송병석;송신우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.185-190
    • /
    • 2003
  • At the present, a stud bolt welding was achieved by the manual method. The manual method caused many problems of work evasion. In order to work out these problems, an automatic welding system is designed for a stud bolt welding system. The system is composed of articulated type welding robot, stud gun, stud feeder, stud controller and various jig.

  • PDF

Applications of Restoration Conditions in Distribution Automation System (배전계통 정전복구능력 평가방법의 응용)

  • Lim, Seong-Il;Ha, Bok-Nam;Cho, Nam-Hoon;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.486-488
    • /
    • 2000
  • This paper presents a methodology to evaluate the restoration capability of the feeder and its applications to the system planning and operation in the normal and emergency states. The proposed method is very simple and practical, so its application to the real system operation is expected to increase the system reliability.

  • PDF

An Auto-drawing Algorithm for the Single Line Diagram of Distribution Systems (배전선로 회선별단선도 자동생성 알고리즘)

  • Son, Ju-Hwan;Lim, Seong-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.5
    • /
    • pp.854-859
    • /
    • 2010
  • Distribution Automation System(DAS) is designed to improve operational efficiency by acquisition and control of remote data using its components such as central computation units, communication network and feeder remote terminal units. A conventional human machine interface of the DAS adopts a schematic diagram which is made by drawing power equipments on the geographic information system map. The single line diagram is more useful than the schematic diagram for the main tasks of distribution system operation such as protective relay coordination, service restoration and loss minimization. Since the configuration of the distribution line is changed according to the relocation of the open tie switches, the auto-drawing algorithm based on the connection between the sections and the switches is an essential technique. This paper proposes a new auto-drawing algorithm for a single line diagram of distribution systems based on tertiary tree and collision avoidance method. The feasibility of the proposed algorithm has been testified for various cases using practical distribution system with 12 feeders.

Double sheet detection system for feeder robots in automation line

  • Kim, Dae-Nyeon;Jo, Kang-Hyun;Shin, In-Seung;Kim, Ki-Su;Kim, Tae-Ho;Kang, Hyun-Duk;Yoon, Yeon-Hong;Kim, Se-Yoon;Lee, Seung-Choon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.73.4-73
    • /
    • 2001
  • We suggest a system to detection whether material picked up is double or single when the robot feeds them in automation line. This system measures thickness of metal plate and alarms when they are double sheet measuring boundary lines of metal sheet. This system calculates the minimum distance of straight boundary lines by eliminating noise in the edge regions. In the experimental system, double or single is determined by calculating implemented the thickness in the image where the distance of pixels are retrieved by the hash table. In this paper, the algorithm of histogram is adapted to experiment in the implement, thus proved as double sheet detection system.

  • PDF