• 제목/요약/키워드: Feedback loop

검색결과 1,242건 처리시간 0.027초

Filtered Velocity Feedback 제어기를 이용한 평판 능동진동제어 (Active Vibration Control of Plates Using Filtered Velocity Feedback Controllers)

  • 신창주;홍진숙;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제21권10호
    • /
    • pp.940-950
    • /
    • 2011
  • This paper reports a filtered velocity feedback(FVF) controller, which is an alternative to direct velocity feedback(DVFB) controller. The instability problems at high frequencies due to non-collocated sensor/actuator configuration with the DVFB can be alleviated by the proposed FVF controller. The FVF controller is designed to filter out the unstable high frequency response. The dynamics of a clamped plate under forces and moments and the FVF controllers are formulated. The stability of the control system and performance are investigated with the open loop transfer function(OLTF). It is found that the FVF controller has a higher gain margin than the corresponding DVFB controller owing to the rapid roll-off behavior at high frequencies. Although the gain margin cannot be fully utilized because of the enhancement at the high frequencies, the vibration at the modes lower than the tuning frequency is well controlled. This performance of the FVF controller is shown to be improved from that of the DVFB controller. It is, however, noted that the stability around the tuning frequency is very sensitive so that the enhancement in vibration level should be followed. The reduction performance at low frequencies using the FVF controller should be compromised with the enhancement in the vibration at high frequencies while designing the controller.

A Design of 5.8 ㎓ Oscillator using the Novel Defected Ground Structure

  • Joung, Myoung-Sub;Park, Jun-Seok;Lim, Jae-Bong;Cho, Hong-Goo
    • Journal of electromagnetic engineering and science
    • /
    • 제3권2호
    • /
    • pp.118-125
    • /
    • 2003
  • This paper presents a 5.8-㎓ oscillator that uses a novel defected ground structure(DGS), which is etched on the metallic ground plane. As the suggested defected ground structure is the structure for mounting an active device, it is the roles of a feedback loop inducing a negative resistance as well as a frequency-selective circuit. Applying the feedback loop between the drain and the gate of a FET device produces precise phase conversion in the feedback loop. The equivalent circuit parameters of the DGS are extracted by using a three-dimensional EM simulation ,md simple circuit analysis method. In order to demonstrate a new DGS oscillator, we designed the oscillator at 5.8-㎓. The experimental results show 4.17 ㏈m output power with over 22 % dc-to-RF power efficiency and - 85.8 ㏈c/Hz phase noise at 100 KHz offset from the fundamental carrier at 5.81 ㎓.

Electrohydraulic Pump-Driven Closed-Loop Blood Pressure Regulatory System

  • 안재목
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권4호
    • /
    • pp.449-454
    • /
    • 2007
  • An electrohydraulic (EH) pump-driven closed-loop blood pressure regulatory system was developed based on flow-mediated vascular occlusion using the vascular occlusive cuff technique. It is very useful for investigating blood pressure-dependant physiological variability, in particular, that could identify the principal mediators of renal autoregulation, such as tubuloglomerular feedback (TGF) and myogenic (MYO), during blood pressure regulation. To address this issue, renal perfusion pressure (RPP) should be well regulated under various experimental conditions. In this paper, we designed a new EH pump-driven RPP regulatory system capable of implementing precise and rapid RPP regulation. A closed-loop servo-controlwas developed with an optimal proportional plus integral (PI) compensation using the dynamic feedback RPP signal from animals. An in vivo performance was evaluated in terms of flow-mediated RPP occlusion, maintenance, and release responses. Step change to 80 mmHg reference from normal RPP revealed steady state error of ${\pm}3%$ during the RPP regulatory period after PI action. We obtained rapid RPP release time of approximately 300 ms. It is concluded that the proposed EH RPP regulatory system could be utilized in in vivo performance to study various pressure-flow relationships in diverse fields of physiology, and in particular, in renal autoregulation mechanisms.

Current Mode Integrated Control Technique for Z-Source Inverter Fed Induction Motor Drives

  • Thangaprakash, Sengodan;Krishnan, Ammasai
    • Journal of Power Electronics
    • /
    • 제10권3호
    • /
    • pp.285-292
    • /
    • 2010
  • This paper presents a current mode integrated control technique (CM-ICT) using a modified voltage space vector modulation (MSVM) for Z-source inverter (ZSI) fed induction motor drives. MSVM provides a better DC voltage boost in the dc-link, a wide range of AC output voltage controllability and a better line harmonic profile. In a voltage mode ICT (VM-ICT), the outer voltage feedback loop alone is designed and it enforces the desired line voltage to the motor drive. An integrated control technique (ICT), with an inner current feedback loop is proposed in this paper for the purpose of line current limiting and soft operation of the drive. The current command generated by the PI controller and limiter in the outer voltage feedback loop, is compared with the actual line current, and the error is processed through the PI controller and a limiter. This limiter ensures that, the voltage control signal to the Z-source inverter is constrained to a safe level. The rise and fall of the control signal voltage are made to be gradual, so as to protect the induction motor drive and the Z-source inverter from transients. The single stage controller arrangement of the proposed CM-ICT offers easier compensation. Analysis, Matlab/Simulink simulations, and experimental results have been presented to validate the proposed technique.

A Single-Input Single-Output Approach by using Minor-Loop Voltage Feedback Compensation with Modified SPWM Technique for Three-Phase AC-DC Buck Converter

  • Alias, Azrita;Rahim, Nasrudin Abd.;Hussain, Mohamed Azlan
    • Journal of Power Electronics
    • /
    • 제13권5호
    • /
    • pp.829-840
    • /
    • 2013
  • The modified sinusoidal pulse-width modulation (SPWM) is one of the PWM techniques used in three-phase AC-DC buck converters. The modified SPWM works without the current sensor (the converter is current sensorless), improves production of sinusoidal AC current, enables obtainment of near-unity power factor, and controls output voltage through modulation gain (ranging from 0 to 1). The main problem of the modified SPWM is the huge starting current and voltage (during transient) that results from a large step change from the reference voltage. When the load changes, the output voltage significantly drops (through switching losses and non-ideal converter elements). The single-input single-output (SISO) approach with minor-loop voltage feedback controller presented here overcomes this problem. This approach is created on a theoretical linear model and verified by discrete-model simulation on MATLAB/Simulink. The capability and effectiveness of the SISO approach in compensating start-up current/voltage and in achieving zero steady-state error were tested for transient cases with step-changed load and step-changed reference voltage for linear and non-linear loads. Tests were done to analyze the transient performance against various controller gains. An experiment prototype was also developed for verification.

Robust Stability eEaluation of Multi-loop Control Systems Based on Experimental Data of Frequency Response

  • Chen, Hong;Okuyama, Yoshifumi;Takemori, Fumiaki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1995년도 Proceedings of the Korea Automation Control Conference, 10th (KACC); Seoul, Korea; 23-25 Oct. 1995
    • /
    • pp.360-363
    • /
    • 1995
  • In this paper, we describe the composition of frequency response bands based on experimental data of plants (controlled systems) with uncertainty and nonlinearity, and the robust stability evaluation of feedback control systems. Analysis and design of control systems using the upper and lower bounds of such experimental data would be effective as a practicable method which is not heavily dependent upon mathematical models such as the transfer function. First, we present a method to composite gain characteristic bands of frequency response of cascade connected plants with uncertainty and a recurrent inequality for the composition. Next, evaluation methods of the robust stability of multi-loop control systems obtained through feedback from the output terminals and multi-loop control systems obtained through feedback into the input terminals are described. In actual control systems, experimental data of frequency responses often depends on the amplitude of input. Therefore, we present the evaluation method of the nominal value and the width of the frequency response band in such a case, and finally give numerical examples based on virtual experimental data.

  • PDF

Digital PLL을 이용한 Active Frequency Drift Positive Feedback에 관한 연구 (Active Frequency Drift Positive Feedback Method for Anti-islanding applied Digital Phase-Locked-Loop)

  • 이기옥;최주엽;최익;정영석;유권종;송승호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.250-254
    • /
    • 2007
  • As photovoltaic(PV) power generation systems become more common, it will be necessary to investigate islanding detection method for PV systems. Islanding of PV systems can cause a variety of problems and must be prevented. However, if the real and reactive powers of the load and PV system are closely matched, islanding detection by passive methods becomes difficult. Also, most active methods lose effectiveness when there are several PV systems feeding the same island. The active frequency drift positive feedback method(AFDPF) enables islanding detection by forcing the frequency of the voltage in the island to drift up or down. In this paper the research for the minimum value of chopping fraction gain applied digital phase-locked-loop (DPLL) to AFDPF considering output power quality and islanding prevention performance are performed by simulation and experiment according to IEEE Std 929-2000 islanding test.

  • PDF

정량적 궤환이론을 이용한 PID 제어기 설계 및 터빈 속도제어 (A Design of PID Controller using Quantitative Feedback Theory and Turbine Speed Control)

  • 김주식
    • 조명전기설비학회논문지
    • /
    • 제16권4호
    • /
    • pp.1-7
    • /
    • 2002
  • 정량적 궤환이론(Quantitative Feedback Theory : QFT)은 플랜트 불확실성과 외란에도 불구하고 요구된 시스템의 제어성능을 성취하기 위해서 궤환의 사용을 강조하는 매우 실제적인 설계기법이다. 이 QFT의 루프형성과정은 요구된 경계조건이 만족될 때까지 강인한 제어기를 설계하는 것을 허용한다. 본 논문에서는 QFT의 루프형성을 이용한 PID 제어기의 최적 설계방법을 제안한다. 제안된 방법은 QFT 경계조건에 의해 얻어진 2차원의 시스템 행렬과 출력 벡터를 재배열하는 것으로부터 전개된 선형 연립방정식으로부터 PID 제어기의 파라미터 벡터를 식별하는 방식이다. 제안된 방법의 유용성은 터빈의 속도제어 문제에 의해 검증하였다.

RF 가열용 S-대역 반도체 전력 발진기 (S-Band Solid State Power Oscillator for RF Heating)

  • 장광호;김보기;최진주;최흥식;심성훈
    • 한국전자파학회논문지
    • /
    • 제29권2호
    • /
    • pp.99-108
    • /
    • 2018
  • 본 논문은 마그네트론 대체를 위한 반도체 전력 발진기 모듈 설계에 관련된 내용을 기술하였다. 300급 LDMOS 단일 전력 증폭기의 특성을 확인하였고 두 개를 결합하여 모듈을 구성하였다. 결합된 모듈에 delay-line feedback loop을 구성하고 위상 천이기를 이용하여 위상을 조절하여 발진기를 구동시켰다. 발진기 모듈 측정 결과 주파수 2.327 GHz에서 출력 800 W, 효율 58 %로 측정되었다. 이 결과는 시뮬레이션 결과와 유사한 특성을 보여준다.

A Hybrid Control Development to Suppress the Noise in the Rectangular Enclosure using an Active/Passive Smart Foam Actuator

  • Kim Yeung-Shik;Kim Gi-Man;Roh Cheal-Ha;Fuller C. R.
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제6권4호
    • /
    • pp.37-43
    • /
    • 2005
  • This paper presents a hybrid control algorithm for the active noise control in the rectangular enclosure using an active/passive foam actuator. The hybrid control composes of the adaptive feedforward with feedback loop in which the adaptive feedforward control uses the well-known filtered-x LMS(least mean square) algorithm and the feedback loop consists of the sliding mode controller and observer. The hybrid control has its robustness for both transient and persistent external disturbances and increases the convergence speed due to the reduced variance of the jiltered-x signal by adding the feedback loop. The sliding mode control (SMC) is used to incorporate insensitivity to parameter variations and rejection of disturbances and the observer is used to get the state information in the controller deign. An active/passive smart foam actuator is used to minimize noise actively using an embedded PVDF film driven by an electrical input and passively using an absorption-foam. The error path dynamics is experimentally identified in the form of the auto-regressive and moving-average using the frequency domain identification technique. Experimental results demonstrate the effectiveness of the hybrid control and the feasibility of the smart foam actuator.