• 제목/요약/키워드: Feedback control

검색결과 4,432건 처리시간 0.034초

적응 퍼지 궤환선형화기법을 이용한 유도전동기의 제어 (Control of induction motors using adaptive fuzzy feedback linearization techniques)

  • 류지수;김정중;이기상
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.1253-1256
    • /
    • 1996
  • In this paper, a new nonlinear feedback linearization control scheme for induction motors is developed. The control scheme employs a fuzzy nonlinear identification scheme based on fuzzy basis function expansion to adoptively compensate the parameter variations, i.e. rotor resistance, mutual and self inductance etc. An important feature of the proposed control scheme is to incorporate the sliding mode controller into the scheme to speed up convergence rate. Simulation tests show the robust behavior of the proposed controller in the presence of the parameter uncertainties of the machine.

  • PDF

직렬 피이드백 보상기를 이용한 위치제어 유압시스템의 성능향상에 관한 연구 (A study on the performance improvement of hydraulic position control system using series-feedback compensator)

  • 이교일;이종극
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국내학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.332-337
    • /
    • 1988
  • A digital series-feedback compensator algorithm for tracking time-varying signal is presented. The series-feedback compensator is composed of one closed loop pole / zero cancellation compensator and one desired-input generator. This algorithm is applied to nonlinear hydraulic position control system. The hydraulic servo system is modelled as a second order linear model and cancellation compensator is modelled from it. The desired input generator is inserted to reduce modelling error. Digital computer simulation output using this control method is present and the usefulness of this control algorithm for nonlinear hydraulic system is verified.

  • PDF

비선형 유압 서보시스템의 비선형 변환 및 이에 대한 선형제어에 관한 연구 (Application of the nonlinear transformation and linear state state feedback control to nonlinear hydraulic servo system)

  • 김영준;장효환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1989년도 한국자동제어학술회의논문집; Seoul, Korea; 27-28 Oct. 1989
    • /
    • pp.272-275
    • /
    • 1989
  • In this paper feedback linearization of valve-controlled nonlinear hydraulic velocity control system is studied. The $C^{\infty}$ nonlinear transformation T is obtained, and it is shown that this transformation is global one. Linear equivalence of nonlinear hydraulic velocity control system is obtained by this global nonlinear transformation, and linear state feedback control law is applied to this linear model. It is shown that this transformation method is to the linear approximation by simulation study..

  • PDF

복식호흡 훈련과 Self Voice Feedback 프로그램이 성대결절 환자의 음성개선에 미치는 효과 (Effects of Abdominal Respiration and Self Voice Feedback Therapy on the Voice Improvement of Patients with Vocal Nodules)

  • 권순복;왕수건;양병곤;전계록
    • 음성과학
    • /
    • 제13권3호
    • /
    • pp.133-149
    • /
    • 2006
  • This study attempted to compare acoustic parameters, physiological observation and perceptual evaluation values obtained from the treatment and control groups in order to find out which of the self voice feedback therapies was better and which methods to train them were more effective. The experimental group carried out various self voice feedback therapies while the control group did only vocal hygiene. The acoustic measurement and voice manipulation for providing the patients visual, auditory feedback were done by a speech analysis software, Praat. The authors designed vocal hygiene, abdominal respiration and Praat self voice feedback therapies and applied them to 15 patients while applying only one vocal hygiene to 15 of the control group. For the purpose of examining the degree of their voice improvement after the treatment, pre- mid- and final evaluations were made for the two groups at the beginning, the 6th week and immediately after the 8th treatment session. Results of this study were as follows: The treatment group showed much improvement after receiving the voice treatment. In particular, acoustical and physiological indices from the optical endoscopy, pitch variation(Jitter), amplitude variation (Shimmer), maximum phonation time(MPT), and psychoacoustic evaluation showed statistically significant improvements over the control groups.

  • PDF

강인성 제어 시스템과 구조 시스템의 통합 최적 설계 (Combined Design of Robust Control System and Structure System)

  • 박중현
    • 동력기계공학회지
    • /
    • 제7권4호
    • /
    • pp.38-43
    • /
    • 2003
  • This paper proposes an optimum design problem of structural and control systems. taking a 3-D truss structure as an example. The structure is supposed to be subjected to initial static loads and time-varying disturbances. The structure is controlled by a state feedback $H_{\infty}$ controller to suppress the effect of the disturbances. The design variables are the cross sectional areas of truss members. The structural objective function is the structural weight. As the control objective, we consider two types of performance indices. The first function represents the effect of the initial loads. The second one is the norm of the feedback gain. These objective functions are in conflict with each other. Then, first, two control objective functions are transformed into one control objective by the weighting method. Next, the structural objective is treated as the constraint. By introducing the second control objective which considers the magnitude of the feedback gain, we can per limn the design which is robust in modeling errors.

  • PDF

Robust Nonlinear Control of Air-to-Fuel Ratio in Spark Ignition Engines

  • Myoungho Sunwoo;Paljoo Yoon;Park, Seungbum;Lee, Wootaik
    • Journal of Mechanical Science and Technology
    • /
    • 제15권6호
    • /
    • pp.699-708
    • /
    • 2001
  • This paper presents a new approach to the AFR (Air-to-Fuel Ratio) control problem, which is based on the wide-band oxygen sensor output. The dedicated nonlinear controller is based on the feedback lineaization technique. It is well known that the feedback linearizing control technique requires an exact model of the plant for the cancellation of plant nonlinearities. A sliding mode control scheme is applied which can effectively compensate the modeling uncertainties. The measurement time delay of an oxygen sensor limits the gain of the feedback controller. Hence, time delay compensation procedure is necessary for the improvement of control performance. The Smith predictor is adopted to compensate the effects of time delay. The simulation and experimental results show that the proposed controllers can effectively reduce the transient peaks of AFR in spite of fast tip-in and tip-out maneuvers of the throttle.

  • PDF

Feedback Loop Design for Micro Gyroscope

  • Sung, Woon-Tahk;Song, Jin-Woo;Lee, Jang-Gyu;Taesam Kang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.39.4-39
    • /
    • 2002
  • This paper presents a design and implementation of a PID feedback control loop for micro gyroscope. The feedback control loop improves the gyroscope performance such as linearity, bandwidth, and bias stability for micro gyroscope which is basically a high-Q system and exhibits a low performance with an open loop control. The designed and implemented feed-back control loop is applied to the SNU-Bosch MEMS gyroscope to demonstrate the improvement with the feedback control loop. The bandwidth is improved to 60Hz from 25Hz of open loop control. The linearity becomes 0.5% from 1%. The bias stability is improved to 0.03 deg/sec from 0.06 deg/sec.

  • PDF

대규모 시스템을 위한 LMI기반 비집중화 슬라이딩 모드 정적 출력 궤환 제어기 설계 (An LMI-based Decentralized Sliding Mode Static Output Feedback Control Design Method for Large Scale Systems)

  • 최환호
    • 제어로봇시스템학회논문지
    • /
    • 제14권4호
    • /
    • pp.381-384
    • /
    • 2008
  • In this paper, we consider the problem of designing decentralized sliding mode static output feedback control laws for a class of large scale systems with mismatched uncertainties. We derive a sufficient condition for the existence of a linear switching surface in terms of constrained linear matrix inequalities(LMIs), and we parameterize the linear switching surfaces in terms of the solution matrices to the given constrained LMI existence conditions. We also give an LMI-based algorithm for designing decentralized switching feedback control laws. Finally, we give a design example in order to show the effectiveness of our method.

Active feedback control for cable vibrations

  • Ubertini, Filippo
    • Smart Structures and Systems
    • /
    • 제4권4호
    • /
    • pp.407-428
    • /
    • 2008
  • The nonlinear mechanics of cable vibration is caught either by analytical or numerical models. Nevertheless, the choice of the most appropriate method, in consideration of the problem under study, is not straightforward. A feedback control policy might even enhance the complexity of the system. Thus, in order to design a suitable controller, different approaches are here adopted. Devices mounted transversely to the cable in the two directions, close to one of its ends, supply the feedback control action based on the observation of the response in a few points. The low order terms of the control law are, at first, analyzed in the framework of linear models. Explicit analytic solutions are derived for this purpose. The effectiveness of high order terms in the control law is then explored by means of a finite element model(FEM), which accounts for high order harmonics. A suitably dimensional analytical Galerkin model is finally derived, to investigate the effectiveness of the proposed control strategy, when applied to a physical model.

Profibus-DP에서의 원격 피드백 제어 시스템 구축 (Implementation of Remote Feedback Control System via Profibus-DP Network)

  • 이경창;강송;이석
    • 한국정밀공학회지
    • /
    • 제18권5호
    • /
    • pp.120-129
    • /
    • 2001
  • As many sensors and actuators are used in many automated systems, various industrial networks are adopted for real-time distributed control. In order to take advantages of the networking, however, the network implementation should be carefully designed to satisfy real-time requirements considering network delays. This paper presents the implementation of a remote feedback control system via Profibus-DP net work for real-time distributed control More specifically, the effect of the network delay on the control performance evaluated on Profibus-DP testbed. Also, the traditional PID gain tuning methods are used to demonstrate the feasibility of the remote feedback control.

  • PDF