• 제목/요약/키워드: Feed Back

검색결과 651건 처리시간 0.024초

정보화 시공에서 Feed Back Analysis (터널, 암반사면, 지반굴착 등 Hard Material 사례중심으로) (The Role of Feed Back Analysis in Observational Method)

  • 김학문
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.147-179
    • /
    • 2002
  • The important role of observational method in geotechnical engineering are emphasized together with the direction of future development, concerning successful application of the technique on the site investigation, design and feed back at various construction stages. Case histories on the application of feed back are introduced in order to achieve the most economical and reliable construction for tunnel, rock slope and deep excavations through feed back system at design and construction stages. Also the limitations and advantages of the observational method and the role of feed back system are discussed for construction of tunnel, rock slope and deep excavation in hard ground such as layered ground conditions including weathered, soft and hard rocks.

  • PDF

볼-막대 시스템의 안정화를 위한 선형제어에 관한 연구 (Stabilization control of inverted Ball-Beam system by the linear controller)

  • 신기수;박래방;권순재
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.76-79
    • /
    • 1999
  • A study on simulation using Matlab shows the dynamic condition of a beam on feed-back with encorder. A controller for rapid response interpreted the stability on simulation with pole-placement technique. The effect of response was considered feed-back gain. The result of feed-back is described that various feed-back coefficient shows stable controll systems. It would be expected each result according to controllers.

  • PDF

Single Transistor에 의한 전파정류 Technique (A Technique for Full Wave Rectification using a Single Transistor)

  • 이주근;이동근
    • 대한전자공학회논문지
    • /
    • 제15권3호
    • /
    • pp.7-10
    • /
    • 1978
  • 이 논문은 single transistor를 사용하여 정현파를 전파정류하는 한 방법을 검토한다. switching으로 동작되는 inverter에 R-feed back을 하고 최적 parameter를 설정하므로써 도통상태의 반파와 cut-off 상태에서 feed back을 통한 반파를 합성하여 전파정류의 출력을 얻는다. cassette deck의 code재생 system에 이용한 바 효과적이었고, AGC 등에 이용 가능하다.

  • PDF

Comparative effect of crumbled or mashed feed form on growth performance, nutrient digestibility, backfat thickness, and carcass quality of growing-finishing pigs

  • Sharif Uddin Khan;In Ho Kim
    • 농업과학연구
    • /
    • 제50권4호
    • /
    • pp.595-602
    • /
    • 2023
  • Feed processing methods can substantially enhance the nutrient value of feed. The aim of our study was to compare the effects of mash or crumble feed on growth performance, nutrient digestibility, back-fat thickness, and carcass quality of growing-finishing pigs. In total, 50 ([Landrace × Yorkshire] × Duroc) growing pigs with initial body weight of 46.24 ± 3.57 kg were randomly assigned to two dietary treatment groups. The two dietary treatments were: 1) mash and 2) crumble feed forms for 14 weeks of trials. Five replication pens per treatment, comprised five pigs (2 males and 3 females) each. Growth performance, nutrient digestibility, back-fat thickness, and carcass quality were observed at different weeks. There were no significant differences in growth performance, nutrient digestibility, back-fat thickness, and carcass quality throughout the experimental trial. Further study is required to understand the effects of mash and crumble feed on growing-finishing pigs.

The Study of Single Phase Source Stability consider for The DSC Cell's Operation Character by Controlled Feed-back Circuit

  • Lee, Hee-Chang
    • Journal of information and communication convergence engineering
    • /
    • 제4권4호
    • /
    • pp.170-173
    • /
    • 2006
  • Recently, with increasing efficiency of DSC (photo-electrochemical using a nano-particle), The Performance of DSC solar generation system also needs improvement. The approach consists of a Fly-back DC-DC (transfer ratio 1:10) converter to boost the DSC cell voltage to 300VDC. The four switch (MOSFET) inverter is employed to produce 220V, 60Hz AC outputs. High performance, easy manufacturability, lower component count., safety and cost are addressed. Protection and diagnostic features form an important part of the design. Another highlight of the proposed design is the control strategy, which allows the inverter to adapt to the: requirements of the load as well as the power source. A unique aspect of the design is the use of the DSP TMS320LF2406 to control the inverter by current and voltage feed-back. Efficient and smooth control of the: power drawn from the DSC Cell is achieved by controlling the front end DC-DC converter in current mode.

기존 지하 Box 근접 굴착공사 현장의 계측결과를 이용한 역해석 및 보강방안의 적용 사례 (A Case Study on the Feed-Back Analysis and the Reinforcement Plan using the Measurement Data of Excavation Site close to the Existing Underground Box)

  • 이정희;노원석;정순익;김완종
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.445-456
    • /
    • 2010
  • Massive underground excavation can be carried out recently due to the technical development of the excavation for retaining wall. Feed-back analysis using field measurement results is recommended to secure the stability of the construction because calculated values at stages of the design and the construction are uncertain. Reinforcement plan should be established based on the result of it. This study deals with the underground excavation site, which is under construction and is close to structure(subway) at downtown area. The result of feed-back analysis on the measurement data of displacement at multi-soil layers was reflected to make a plan for safe construction. This case study can be useful information for contingency plan on abnormal displacement which can be occurred at similar underground excavation.

  • PDF

시공단계의 효율적 공사관리를 위한 Web기반 하자정보 Feed-Back시스템 구현방안 - 공동주택을 중심으로 - (The Implementation of Web-based Defect Information Feed-Back System for Construction Management in the Construction Process -Focused on Apartment Houses-)

  • 조용민;박태근
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2002년도 학술대회지
    • /
    • pp.482-485
    • /
    • 2002
  • 200만호 주택건설로 폭발된 1980년대 주택건설 시장의 활성화는 수도권 및 신도시를 중심으로 많은 APT를 양산하였고 그 과정에서 품질수준은 물량 공급 위주의 주택정책으로 소비자의 욕구를 충족시키지 못하였고 준공된 건물에서는 예상치 못한 많은 하자를 발생시켰다. 이에 따라 $1980\~1990$년대 공동주택의 하자 예방을 위한 연구가 수행되어 하자 다발 공종과 분야별 빈도 및 하자 발생으로 인한 손실추정 등 여러 연구 성과가 축적되었으나 하자 발생율을 줄이고 하자로 인한 소비자의 불만족을 해소시키는데는 크게 기여하지 못하고 있다. 이는 하자 관련 연구가 실제 공사를 수행하는 시점에 적절히 관리하고 통제하는 SYSTEM과 연계되지 못하고, 제대로 적용되지 못하기 때문이다. 따라서 본 연구에서는 국내 건설공사 중에서 공통주택에서 발생하는 하자에 관한 정보와 현황에 대한 분석을 실시하고, 그 유형별 특성에 따른 분류를 실시한 뒤 이를 종합하여 체계적인 정보의 확보 및 활용을 위한 WEB 기반 FEED-BACK 시스템을 제안하고자 한다.

  • PDF

Sensor and actuator design for displacement control of continuous systems

  • Krommer, Michael;Irschik, Hans
    • Smart Structures and Systems
    • /
    • 제3권2호
    • /
    • pp.147-172
    • /
    • 2007
  • The present paper is concerned with the design of distributed sensors and actuators. Strain type sensors and actuators are considered with their intensity continuously distributed throughout a continuous structure. The sensors measure a weighted average of the strain tensor. As a starting point for their design we introduce the concept of collocated sensors and actuators as well as the so-called natural output. Then we utilize the principle of virtual work for an auxiliary quasi-static problem to assign a mechanical interpretation to the natural output of the sensors to be designed. Therefore, we take the virtual displacements in the principle of virtual work as that part of the displacement in the original problem, which characterizes the deviation from a desired one. We introduce different kinds of distributed sensors, each of them with a mechanical interpretation other than a weighted average of the strain tensor. Additionally, we assign a mechanical interpretation to the collocated actuators as well; for that purpose we use an extended body force analogy. The sensors and actuators are applied to solve the displacement tracking problem for continuous structures; i.e., the problem of enforcing a desired displacement field. We discuss feed forward and feed back control. In the case of feed back control we show that a PD controller can stabilize the continuous system. Finally, a numerical example is presented. A desired deflection of a clamped-clamped beam is tracked by means of feed forward control, feed back control and a combination of the two.

Magnetic Flux Leakage (MFL) based Defect Characterization of Steam Generator Tubes using Artificial Neural Networks

  • Daniel, Jackson;Abudhahir, A.;Paulin, J. Janet
    • Journal of Magnetics
    • /
    • 제22권1호
    • /
    • pp.34-42
    • /
    • 2017
  • Material defects in the Steam Generator Tubes (SGT) of sodium cooled fast breeder reactor (PFBR) can lead to leakage of water into sodium. The water and sodium reaction will lead to major accidents. Therefore, the examination of steam generator tubes for the early detection of defects is an important requirement for safety and economic considerations. In this work, the Magnetic Flux Leakage (MFL) based Non Destructive Testing (NDT) technique is used to perform the defect detection process. The rectangular notch defects on the outer surface of steam generator tubes are modeled using COMSOL multiphysics 4.3a software. The obtained MFL images are de-noised to improve the integrity of flaw related information. Grey Level Co-occurrence Matrix (GLCM) features are extracted from MFL images and taken as input parameter to train the neural network. A comparative study on characterization have been carried out using feed-forward back propagation (FFBP) and cascade-forward back propagation (CFBP) algorithms. The results of both algorithms are evaluated with Mean Square Error (MSE) as a prediction performance measure. The average percentage error for length, depth and width are also computed. The result shows that the feed-forward back propagation network model performs better in characterizing the defects.

Low-Voltage Current Feed-back Amplifier

  • Wisetphanichkij, Sompong;Dejhan, Kobchai;Suklueng, Montri
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1877-1880
    • /
    • 2005
  • This paper proposed the new current feed-back amplifier for low supply voltage application. The input stage was designed to be a class-AB circuit and achieve the low supply-voltage operation down to $2V_{TH}+2V_{DS(SAT)}$. With the self-adjust bias current, the high performance can be adopted with high stability. The circuit was successfully proven by the simulation with MOSIS 0.5 ${\mu}$m MOS technology.

  • PDF