• Title/Summary/Keyword: Fe-Pc

Search Result 107, Processing Time 0.028 seconds

Damage of P/U by Crash in the Optical Disk Drive (광 디스크 드라이브의 P/U 낙하 추돌 거동)

  • 황효균;김남웅;이동호;이진우;김외열
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.958-961
    • /
    • 2002
  • The optical disk drive is a basic option on the PC now. So the lower price and higher read/write speed goods are now on market. These trends make many difficulties to produce more reliable drives, comparing when they are treated as high price stuff. In mechanical terms, the lower price and higher read/write speed drive make higher vibration and noise, lower stiffness, even severe fracture of cheap and low quality disk, problems. Due to the internal crash of P/U inside of the drive, the failure of drives, inferior drives, increase more and more by the careless transportation and the originated low stiffness parts. This report is the introduction of the FE simple model to decrease the internal P/U crash problems, and the results.

  • PDF

Design and Fabrication of Low-Power, High-Frequency, High-Performance Magnetic Thin Film Transformer (저전력, 고주파, 고효율 자성박막 변압기 설계 및 제작에 대한 연구)

  • Yun, Ui-Jung;Jeong, Myeong-Hui
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.11
    • /
    • pp.555-561
    • /
    • 2001
  • In this paper, the low power (1.5 W) solenoid-type magnetic thin-film transformers utilizing a $Ni_{81}Fe_{19)$ core material were designed and fabricated for 5 MHz-drive DC-DC converter application. The $20\mum$ thick copper films were used as the coils. The transformers fabricated in this work have the sizes of $3.08 mm\times25.5 mm\; and\; 6.15 mm\times12.75 mm.$ The optimum design of solenoid-type magnetic thin film transformers was performed utilizing the conventional equations, a Maxwell computer simulator (Ansoft HFSS V7.0 for PC), and parameters obtained from the magnetic properties of NiFe magnetic core materials. frequency characteristics of inductance, dc resistance (R), coupling factor (k) and gain of developed transformers were measured using HP4194A impedance and gain-phase analyzer. The fabricated transformers with the size of $6.15 mm\time12.75 mm$ exhibit the inductance of $0.83 \muH$, the dc resistance of $2.3\Omega$$\Omega$, the k of 0.91 and the gain of -1 dB at 5 MHz, which show the comparable results to those reported in the recent literatures. The measured high-frequency characteristics for the fabricated transformers agreed well with those obtained by theoretical calculations .

  • PDF

NEAR-INFRARED PHOTOMETRIC STUDY OF THE GALACTIC OPEN CLUSTERS NGC 1641 AND NGC 2394 BASED ON 2MASS DATA

  • Kim, Sang-Chul
    • Journal of The Korean Astronomical Society
    • /
    • v.39 no.4
    • /
    • pp.115-123
    • /
    • 2006
  • We present $JHK_S$ near-infrared CCD photometric study for the Galactic open clusters NGC 1641 and NGC 2394. These clusters have never been studied before, and we provide, for the first time the cluster parameters; reddening, distance, metallicity and age. NGC 1641 is an old open cluster with age $1.6{\pm}0.2$ Gyr, metallicity $[Fe/H]=0.0{\pm}0.2$ dex, distance modulus$(m-M)_0=10.4{\pm}0.3\;mag(d=1.2{\pm}02\;kpc)$, and reddening $E(B-V)=0.10{\pm}0.05$ mag. The parameters for the other old open cluster NGC 2394 are estimated to be $age=1.1{\pm}0.2$ Gyr, $[Fe/H]=0.0{\pm}0.2$ dex, $(m-M)_0=9.1{\pm}0.4\;mag(d=660{\pm}120\;pc)$, and $E(B-V)=0.05{\pm}0.10$ mag. The metallicities and distance values for these two old open clusters are consistent with the relation between the metallicities and the Galactocentric distances of other old open clusters. We find the metallicity gradient of 53 old open clusters including NGC 1641 and NGC 2394 to be ${\Delta}[Fe/H]/{\Delta}R_{gc}=-0.067{\pm}0.009\;dex\;kpc^{-1}$.

A Study on Fabrication of Magnetic Thin Film Inductors for DC-DC Converter

  • Lee, Young-Ae;Kim, Sang-Gi;Do, Seung-Woo;Lee, Yong-Hyun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.225-225
    • /
    • 2010
  • In this study, the optimum structure of a magnetic thin film inductor was designed for application of DC-DC converters. The $Ni_{81}Fe_{19}$ (at%) alloy was selected as a high-frequency($\geq$ MHz) magnetic thin film core material and deposited on various substrates (bare Si, $SiO_2$ coated Si) using a high vacuum RF magnetron sputtering system. As-deposited NiFe thin films show similar magnetic properties compared to bulk NiFe alloys, indicating that they have a good film quality. The optimum design of solenoid-type magnetic thin film inductors was performed utilizing a Maxwell computer simulator (Ansoft HFSS V7.0 for PC) and parameters obtained from the magnetic properties of magnetic core materials selected. The high-frequency characteristics of the inductance(L) and quality factor(Q) obtained for the designed inductors through simulation agreed well with those obtained by theoretical calculations, confirming that the simulated result is realistic. The optimum structure of high-performance ($Q{\geq}60$, $L\;=\;1{\mu}H$, efficiency${\geq}90%$), high-frequency (${\geq}5MHz$), and solenoid-type magnetic thin film inductors was designed successfully.

  • PDF

모니터의 시장불량률 감소를 위한 신뢰성 시험법 개발

  • 김준홍;권수호
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2000.04a
    • /
    • pp.169-174
    • /
    • 2000
  • 사용환경에서 발생하는 PC 모니터의 고장을 실험실에서 재현하기 위해 Power On/off, DPM 모드, 사용전압, Surge 유입, Torque 강도 등의 인자에 대해 여러 가지수준으로 직교배열표에 의해 실험한 결과를 토대로 시험 프로세스를 정립하여 제품설계 및 신제품 개발에 이용하였다. 실험결과와 SN 비 계산에 의하면 모니터 수평출력 TR의 고장에 대한 요인은 Mode 절환, Torque, h$_{FE}$ 산포에 유의한 영향이 있었으며, 이에 대한 IQC에서의 부품시험법, Torque 관리, TR 설계 Spec 변경을 제안하였다.

  • PDF

Biostability and Drug Delivery Efficiency of γ-Fe2O3 Nano-particles by Cytotoxicity Evaluation (세포독성 평가를 통한 γ-Fe2O3 나노입자의 생체안정성 및 약물전달효율)

  • Lee, Kwon-Jai;An, Jeung-Hee;Shin, Jae-Soo;Kim, Dong-Hee;Yoo, Hwa-Seung;Cho, Chong-Kwan
    • Korean Journal of Materials Research
    • /
    • v.20 no.3
    • /
    • pp.132-136
    • /
    • 2010
  • This study examined the biostability and drug delivery efficiency of g-$Fe_2O_3$ magnetic nanoparticles (GMNs) by cytotoxicity tests using various tumor cell lines and normal cell lines. The GMNs, approximately 20 nm in diameter, were prepared using a chemical coprecipitation technique, and coated with two surfactants to obtain a water-based product. The particle size of the GMNs loaded on hangamdan drugs (HGMNs) measured 20-50 nm in diameter. The characteristics of the particles were examined by X-ray diffraction (XRD), field emission scanning electron microscopy (FE-TEM) and Raman spectrometer. The Raman spectrum of the GMNs showed three broad bands at 274, 612 and $771\;cm^1$. A 3-(4, 5-dimethylthiazol-2-yl)-2, 5-diphenyltetrazolium bromide (MTT) assay showed that the GMNs were non-toxic against human brain cancer cells (SH-SY5Y, T98), human cervical cancer cells (Hela, Siha), human liver cancer cells (HepG2), breast cancer cells (MCF-7), colon cancer cells (CaCO2), human neural stem cells (F3), adult mencenchymal stem cells (B10), human kidney stem cells (HEK293 cell), human prostate cancer (Du 145, PC3) and normal human fibroblasts (HS 68) tested. However, HGMNs were cytotoxic at 69.99% against the DU145 prostate cancer cell, and at 34.37% in the Hela cell. These results indicate that the GMNs were biostable and the HGMNs served as effective drug delivery vehicles.

Synthesis and electrochemical performance of transition metal-coated carbon nanofibers as anode materials for lithium secondary batteries

  • Choi, Jin-Yeong;Hyun, Yura;Park, Heai-Ku;Lee, Chang-Seop
    • Journal of Industrial and Engineering Chemistry
    • /
    • v.68
    • /
    • pp.161-167
    • /
    • 2018
  • In this study, transition metal coated carbon nanofibers (CNFs) were synthesized and applied as anode materials of Li secondary batteries. CNFs/Ni foam was immersed into 0.01 M transition metal solutions after growing CNFs on Ni foam via chemical vapor deposition (CVD) method. Transition metal coated CNFs/Ni foam was dried in an oven at $80^{\circ}C$. Morphologies, compositions, and crystal quality of CNFs-transition metal composites were characterized by scanning electron microscopy (SEM), Raman spectroscopy (Raman), and X-ray photoelectron spectroscopy (XPS), respectively. Electrochemical characteristics of CNFs-transition metal composites as anodes of Li secondary batteries were investigated using a three-electrode cell. Transition metal/CNFs/Ni foam was directly employed as a working electrode without any binder. Lithium foil was used as both counter and reference electrodes while 1 M $LiClO_4$ was employed as the electrolyte after it was dissolved in a mixture of propylene carbonate:ethylene carbonate (PC:EC) at 1:1 volume ratio. Galvanostatic charge/discharge cycling and cyclic voltammetry measurements were taken at room temperature using a battery tester. In particular, the capacity of the synthesized CNFs-Fe was improved compared to that of CNFs. After 30 cycles, the capacity of CNFs-Fe was increased by 78%. Among four transition metals of Fe, Cu, Co and Ni coated on carbon nanofibers, the retention rate of CNFs-Fe was the highest at 41%. The initial capacity of CNFs-Fe with 670 mAh/g was reduced to 275 mAh/g after 30 cycles.

FE Analysis of Exterior Wide Beam-Column Connections with Bonded Tendon Stress (부착된 프리스트레스 넓은 보-기둥 외부접합부의 유한요소해석)

  • Lee, Moon-Sung;Choi, Yun-Cheul;Lim, Jaei-Hyung;Moon, Jeong-Ho;Choi, Chang-Sick
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.4
    • /
    • pp.307-315
    • /
    • 2008
  • Post-tensioned precast concrete system (PPS) consists of U-shaped precast wide beams and concrete column. The continuity of beam-column joint is provided with the topping concrete on the PC shell beam and post-tensioning. Nonlinear analysis was conducted, using ANSYS, a finite-element analysis program, to obtain data for determining the characteristics of the structure and to allow various parametric analyses for post-tensioned wide beam-column connections. In this analysis, the Solid 65 element was used, in which concrete element had 8 nodes and each node had 3 degrees of freedomIn. Solid 65, the shear-transfer factor reflects a decrease of shear strength for the positions with cracks, as an impact factor to make the analysis value approximate the experiment value. In this study, the behavior of test specineus were most closely predicted to the experimental results, when the shear-transfer coefficient 0.85 was used for a closed crack, and 0.2 was used for an open crack.

On the Leakage Safety Analysis of Membrane LNG Storage Tank With Thermal Resistance Effects (열저항 효과를 고려한 멤브레인식 LNG 저장탱크의 누설 안전성에 관한 연구)

  • Kim C.K.;Cho S.H.;Suh H.S.;Hong S.H.;Lee S.R.;Kim Y.G.;Kwon B.K.
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.4 s.25
    • /
    • pp.1-7
    • /
    • 2004
  • In this paper, the FE analysis has been presented for the leakage safety of the membrane LNG storage tank based on the thermal resistance effects between the insulation panel and prestressed concrete structure. The FEM calculated results show that the leakage safety of plywood and polyurethane materials does not guarantee any more due to a strength failure of the insulation structure. But the PC structure of outer tank may delay leaked LNG of 10 days even though the inner tank and insulation structure are simultaneously failed. This means that the membrane LNG storage tank may be safe because of the stiffness of the outer tank.

  • PDF

A Fiber Optic Sensor for Determination of 2,4-Dichlorophenol Based on Oxygen Oxidation Catalyzed by Iron(III) Tetrasulfophthalocyanine

  • Tong, Yilin;Li, Dapeng;Huang, Jun;Zhang, Cong;Li, Kun;Ding, Liyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.11
    • /
    • pp.3307-3311
    • /
    • 2013
  • A new fiber optical sensor was developed for the determination of 2,4-dichlorophenol (DCP). The sensor was based on DCP oxidation by oxygen with the catalysis of iron(III) tetrasulfophthalocyanine (Fe(III)PcTs). The optical oxygen sensing film with $Ru(bpy)_3Cl_2$ as the fluorescence indicator was used to determine the consumption of oxygen in solution. A lock-in amplifier was used for detecting the lifetime of the oxygen sensing film by measuring the phase delay change of the sensor head. The different variables affecting the sensor performance were evaluated and optimized. Under the optimal conditions (i.e. pH 6.0, $25^{\circ}C$, Fe(III)PcTs concentration of 0.62 mg/mL), the linear detection range and response time of the sensor are $1.0{\times}10^{-6}-9.0{\times}10^{-6}$ mol/L and 250 s, respectively. The sensor displays high selectivity, good repeatability and stability, and can be used as an effective tool in analyzing DCP concentration in practical samples.