• Title/Summary/Keyword: Fault-prevention

Search Result 149, Processing Time 0.043 seconds

A Fault Tolerance Mechanism with Dynamic Detection Period in Multiple Gigabit Server NICs (다중 Gigabit Server NICs에서 동적 검출 주기를 적용한 결함 허용 메커니즘)

  • 이진영;이시진
    • Journal of Internet Computing and Services
    • /
    • v.3 no.5
    • /
    • pp.31-39
    • /
    • 2002
  • A rapid growth of internet and sudden increase of multimedia data demands for high-speed transfer media and if optimizec usage from the interface system. To achieve this level of network bandwidth, multiple NICs for support of high-speed network bandwidth have been developed and studied. Furthermore, the use of multiple NICs can provide high-speed LAN environment without large network environment modification, supports backward compatibility of current system and reduce overhead. However. if system failure is caused by SPOF(Single Point of Failure) fault of large-capacity multiple NICs, incredible loss will be met because it services large capacity of multimedia data, Therefore, to prevent loss coming from faults, we describe 'Fault tolerance of multiple NICs', which use the fault prevention mechanism. Considering inefficiency of availability and serviceability that is occurred with existing TMR, Primary-Standby approach and Watchdog time mechanism, we propose and design the efficient fault tolerance mechanism, which minimize down time as changing of detection period dynamically. Consequently, the fault tolerance mechanism proposed for reducing overhead time when the fault is occurred, should minimize system downtime overall.

  • PDF

Analysis of Ignition Time/Current Characteristics and Energy when Series Arc-Fault Occurs at Rated 220 V (220 V 직렬 아크고장발생 시 점화 시간/전류 특성 및 에너지 분석)

  • Ko, Won-Sik;Moon, Won-Sik;Bang, Sun-Bae;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.8
    • /
    • pp.1184-1191
    • /
    • 2013
  • Probability of ignition due to arc-fault and energy of the arc-fault for the case of applying serial arc-fault interruption time of 120 V defined in UL 1699 to the voltage of 220 V of domestic condition and also for the case of applying it to the HIV wire type are analyzed. It has been confirmed that when the arc-fault occurs under 5 A, 10 A, and 20 A. Probability of ignition for the three different current conditions is 0.74(74%), 0.48(48%), and 0.32(32%) respectively for respective interruption time within 1 sec, 0.4 sec, and 0.2 sec. We discover that when we apply the same arc interruption time for 120 V defined in UL 1699 to the domestic environment of 220 V. The probability of ignition increases from 1.5% for 120 V condition to as much as 74% for 220 V condition. Conclusively, if we apply the standard for the serial arc-fault interruption time defined in UL 1699 for 120 V to the domestic condition of 220 V, the fire prevention effect of electric fire due to arc-fault equal to that of UL standard of 120 V can not be achieved.

A Minimized Test Pattern Generation Method for Ground Bounce Effect and Delay Fault Detection (그라운드 바운스 영향과 지연고장을 위한 최소화된 테스트 패턴 생성 기법)

  • 김문준;이정민;장훈
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.11
    • /
    • pp.69-77
    • /
    • 2004
  • An efficient board-level interconnect test algorithm is proposed considering both the ground bounce effect and the delay fault detection. The proposed algorithm is capable of IEEE 1149.1 interconnect test, negative ground bounce effect prevention, and also detects delay faults as well. The number of final test pattern set is not much different with the previous method, even our method enables to detect the delay faults in addition to the abilities the previous method guarantees.

Deterioration Pattern Analysis and Surface Leakage Current of Electrical Insulation in External Pollution (외부 오염 환경하에서 고분자 절연재료의 표면 누설전류 측정 및 열화 패턴 분석)

  • Kim, Young-Seok;Shong, Kil-Mok;Kim, Sun-Gu
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2080-2081
    • /
    • 2007
  • In this paper, the polymer insulators which had been used for electrical insulation were investigated surface leakage current and deterioration pattern. Because the electrical fault took place at the dust occurrence area due to environmental pollution. In particular, the dust accumulates easily on insulation material which is exposed an external long time. The leakage current brings out electrical fault after all. Also, it is need to variation of material and shape to repress a leakage current on electrical material. In this paper, we measured a leakage current on electrical material of facilities by dust, and in experiments the prevention to electrical fault was studied.

  • PDF

A hybrid deep learning model for predicting the residual displacement spectra under near-fault ground motions

  • Mingkang Wei;Chenghao Song;Xiaobin Hu
    • Earthquakes and Structures
    • /
    • v.25 no.1
    • /
    • pp.15-26
    • /
    • 2023
  • It is of great importance to assess the residual displacement demand in the performance-based seismic design. In this paper, a hybrid deep learning model for predicting the residual displacement spectra under near-fault (NF) ground motions is proposed by combining the long short-term memory network (LSTM) and back-propagation (BP) network. The model is featured by its capacity of predicting the residual displacement spectrum under a given NF ground motion while considering the effects of structural parameters. To construct this model, 315 natural and artificial NF ground motions were employed to compute the residual displacement spectra through elastoplastic time history analysis considering different structural parameters. Based on the resulted dataset with a total of 9,450 samples, the proposed model was finally trained and tested. The results show that the proposed model has a satisfactory accuracy as well as a high efficiency in predicting residual displacement spectra under given NF ground motions while considering the impacts of structural parameters.

A Study on Development of Over-load Fault Prevention Apparatus using Distribution Line Voltage (배전선로 선로전압을 이용한 과부하 사고 예방장치 개발에 관한 연구)

  • Kwak, D.K.;Park, D.H.;Park, Y.J.;Jung, D.Y.;Kim, D.K.
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.617-618
    • /
    • 2012
  • Recently as the inactive response characteristics of the existing RCD(Residual Current protective Device) used on low voltage power distribution system, so control of overload and electric short circuit faults, major causes of electrical fires, are not enough. Therefore, this paper is proposed a prevention apparatus using neutral line voltage and semiconductor switching devices for the prevention of electrical disasters in low voltage power distribution system caused by overload or electric short circuit faults. The proposed prevention apparatus confirms the excellent characteristics in response velocity and accuracy in comparison with the conventional circuit breaker(RCD) through various operation performance analysis.

  • PDF

Relationship between Earthquake and Fluctuation of Water Level in Active Fault Zone and National Groundwater Monitoring Wells of Gyeongju Area (경주 활성단층대 및 주변 국가지하수 관측정에서 지진과 수위변동 상관관계 연구)

  • Jang, Hyeon-Woo;Jeong, Chan-Ho;Lee, Yong-Cheon;Lee, Yu-Jin;Hong, Jin-Woo;Kim, Cheon-Hwan;Kim, Young-Seog;Kang, Tae-Seob
    • The Journal of Engineering Geology
    • /
    • v.30 no.4
    • /
    • pp.617-634
    • /
    • 2020
  • The purpose of this study is to investigate the relationship of between earthquakes and fluctuation of water level in a groundwater well of the active-fault zone and 124 national groundwater monitoring wells in Gyeongju area. The spatial and temporal relationships between the fluctuation of water level and the earthquake were analyzed by the calculation of earthquake effectiveness (ε) and q-factor which are the function of earthquake magnitude and distance from epicenter. Two earthquake events of E1 (April 22, 2019, M 3.8) and E2 (June 11, 2019, M 2.5) show a close relationship with a post-seismic 83 cm decrease and a pre-seismic 76 cm increase in water level at the active fault zone of Dangu-ri, respectively. The spatial analysis of water level fluctuation data in National Groundwater Monitoring Networks caused by earthquake events shows a more distinct response in deep groundwater around fault zones than other area, and a greater change in deep groundwater than shallow groundwater. It's inferred that the decrease and increase in groundwater level are affected by the expansion of fractures and compression of rock mass due to seismic stress, respectively. The effective ranges of ε-value and q-factor of the monitoring well in Dangu-ri were calculated as 2.70E-10~5.60E-10 and 14.4~18.0, respectively.

On the Current Limiting Characteristics and Parameters of Superconducting Fault Current Limiter Introduced to 345kV Electric Power System due to Resistive-Type, Reactive-Type (유도형과 저항형 초전도한류기의 파라메타를 고려한 전력계통도입효과의 분석 및 고찰)

  • 홍원표;김용학;전영환;이승학
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.285-290
    • /
    • 2002
  • Power systems are becoming larger and larger for meeting electric power demand. Therefore, the over-currents resulting from contingencies such short circuits are increasing higher. The Maximum short circuit current of modern power system is becoming so large that circuit breaker are not expected th be able to shut down the current in the future. In order to cut over-currents, a system composed of a superconducting fault current limiter(SFCL) and traditional breaker seems to provide a promising solution for future power operation. In present paper, three line-to-ground fault is assumed to happen at the center of 345kV transmission lines in a large capacity electric power system The superconducting fault current limiter was represented using a commutation type, which consists of a non-inductive superconducting coil and current limiting element(resistor or reactor). The introduction merits of the SFCL were investigated quantitatively by RTDS/EMTDC from the viewpoint of current limiting performance, the prevention of the voltage drop at the load bus and comparison characteristics for two type SFCL. Desired design specification and operation parameters of SFCL were also given qualitatively by the performance evaluation of the two type SFCL in the power system.

  • PDF

A study on the Correlation Hazard Analysis for Signaling System Safety (안전성 확보를 위한 위험원 분석 기법간 상관관계에 대한 연구)

  • Han, Chan-Hee;Lee, Young-Soo;Ahn, Jin;Jo, Woo-Sic
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.638-645
    • /
    • 2007
  • Computers are increasingly being introduced into safety and reliability critical systems. The safe and reliable operation of these systems cannot be taken for granted. Malfunctions of these systems can have potentially catastrophic consequences and they have already been involved in serious accidents. Software fault prevention, fault tolerance, fault removal and fault forecasting are the techniques to be used, implemented and verified for embedded software in critical systems as the contributors to safety and reliability of the software. To use them when developing a software product, a relationship must be established between them and the development processes, the methods and techniques to be used to develop software, as well as with the different product architectures. Railroad signaling system software is a safety-critical embedded software with realtime and high reliability requirements. The primary purpose of the safety management is to prevent the loss of lives or physical damages arising from potential hazards in the railroad signaling system. This study provides a systematic approach to analysis of potential hazards for their management during the system life cycle to assure the identification and definition of the most appropriate hazards.

  • PDF

The Study of the Design Tests for Current Capability according to ANSI (ANSI 규격에 의한 주상 변압기의 동압력 내력시험에 관한 연구)

  • Kim, Sun-Koo;Kim, Won-Man;La, Dae-Ryeol;Roh, Chang-Il;Lee, Dong-Jun;Jung, Heung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.909-911
    • /
    • 2003
  • The almost pole transformers are constructed with tank, cover, clamp etc., that contains the insulation oil, core, coil, terminals, bus and the other accessories. If some fault current will be flown by some trouble or accident, interior pressure of the transformer shall be very quickly rise, and mechanical components or insulation oil from the transformer enclosure shall be propelled or dropped from the tank. For the prevention of the above accident, recently the pole transformers should be done 'the Design Tests for Fault Current Capability' according to ANSI C57.12.20(1997) There are two tests method in this standard, Test Number I with a high current arcing fault, without internal fusible elements, shall be conducted on rack enclosure with its minimum designed air space. Test Number II with an internal fusible element, shall be conducted on each enclosure diameter utilizing the internal fusible elements. KEPCO recently request to be done the 'Design Tests for Fault Current Capability' for pole transformers according to KEPCO's standard ES141-$533{\sim}545$, PS141-$482{\sim}518$ and RS141-$611{\sim}628$ that is same with Test Number I of ANSI C57.12.20.

  • PDF