• 제목/요약/키워드: Fault current limiters

검색결과 128건 처리시간 0.021초

고온초전도 한류기용 코일의 턴간 절연 특성 (Turn-to-Turn Dielectric Characteristics of Coils for HTSFCL)

  • 백승명;정종만;이창화;류엔반둥;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 제5회 영호남 학술대회 논문집
    • /
    • pp.15-18
    • /
    • 2003
  • Fault current limiters (FCL) are extensively needed to suppress fault currents, especially for trunk power systems heavily connected to high voltage/large current transmission lines. Due to its ideal electrical behavior, high-temperature superconductor fault current limiter (HTSFCL) becomes one of the most important developing trends of limiters in power system. This paper describes the result of an investigation of the dielectric characteristics of turn-to-turn insulation for pancake and solenoid type reactor coil in liquid nitrogen. The influence of thickness in a variety length, on AC, DC and impulse surface flashover has been investigated. Also, the relationships between the number of turn and breakdown characteristics were clarified. The information gathered in this test series should be helpful in the design of liquid nitrogen filled DC reactor type HTSFCL.

  • PDF

직렬연결된 초전도 한류기의 분로저항에 의한 동작특성 (Operating Characteristics of Superconducting Fault Current Limiters Connected in Series by Shunt Resistors)

  • 현옥배;최효상;김혜림;임해룡;김인선
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권11호
    • /
    • pp.737-741
    • /
    • 2000
  • We fabricated resistive superconducting fault current limiters (SFCL) based on YBCO thin films grown on 2-inch diameter $Al_2O_3$ substrates. Two SFCLs with nearly identical properties were connected in series to investigate simultaneous quench. There was a slight difference in the rate of voltage increase between two SFCL units when they were operated independently. This difference resulted in significantly imbalanced power dissipation between the units. This imbalance was removed by connecting a shunt resister to an SFCL in parallel. The appropriate values of shunt resistance were 80 ${\Omega}$ at 75 $V_rms$ and 110 ${\Omega}$ at 120 $V_rms$, respectively. Increased power input at high voltages also reduced the initial imbalance in power dissipation, but with increase in film temperature to higher than 200 K.

  • PDF

저항형 초전도 한류기에서의 퀀치 전파 (Quench propagationin resistive SFCL)

  • 김혜림;현옥배;최효상;황시돌;김상준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.85-88
    • /
    • 1999
  • We fabricated resistive superconducting fault current lmiters based on YBa$_2$Cu$_3$O$_{7}$ thin films and investigated their quench propagation characteristics. The YBa$_2$Cu$_3$O$_{7}$ film was coated with a gold layer and patterned into 1 mm wide meander lines by photolithography. The limiters were tested with simulated fault currents of various fault angles and amplitudes. The quench propagation characteristics were explained based on the heat transfer within the film as well as between the film and the surrounding liquid nitrogen. The quench completion time strongly depended on the potential fault current. It was 1 msec at the peak fault current of 76 A/peak/ and corresponding quench propagation speed was 43 m/sec (film cross section: 4 x 10$^{-6}$ $\textrm{cm}^2$).

  • PDF

션트저항을 통한 박막형 초전도 한류기의 전압등급 증대 (Increase of voltage ratings in the superconducting fault current limiter using thin films by shunt resistors)

  • 최효상;김혜림;황시돌;박권배;현옥배
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.176-177
    • /
    • 2001
  • Three nearly identical superconducting fault current limiters (SFCLs) were connected in series to increase the voltage ratings. A slight difference in the quench starting point of individual SFCL units produced significantly imbalanced power distribution when connected in series. The imbalance was successfully removed by connecting a shunt resistor to one SFCL in parallel. 1.2 kV SFCL was designed with five current limiting elements and two or three shunt resistors.

  • PDF

Experimental Analysis of Superconducting Fault Current Limiter Wound with Two Different HTS wires in Parallel

  • Kim, Ji-Tae;Jang, Jae-Young;Park, Dong-Keun;Chang, Ki-Sung;Kim, Young-Jae;Ko, Tae-Kuk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권2호
    • /
    • pp.30-33
    • /
    • 2008
  • Several kinds of superconducting fault current limiters (SFCLs), which reduces huge fault current, have been developing by many research groups. The SFCL has no impedance during normal operation, so it dose not give any influence to electric power system. The resistive type SFCL reduces the fault current with the impedance generated in the superconducting part of the SFCL when the fault current exceeds the critical current of SFCL. In this paper, a new type resistive SFCL made of bifilar coil wound with two different high-Tc superconducting (HTS) wires in parallel. Although a bifilar coil has theoretically no inductance, the bifilar coil made in this paper could generate inductance at fault. The specifications of the used two wires were considerably different, thus current distribution between the two HTS wire was different at fault. When the fault current exceeded the critical current of one wire in the bifilar coil, the momentary sharp increase of impedance was detected. Base on the results, a new resistive type SFCL can generate not only resistance but also inductance, which can be used to control a fault current in the future.

30 kVA급 유도형 고온초전도 한류기의 특성 연구 (Study on the Characteristics of 30 kVA Inductive High-Tc Superconducting Fault Current Limier)

  • 이찬주;이승제;강형구;배덕권;안민철;현옥배;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.110-113
    • /
    • 2002
  • The high-tc superconducting fault current limiters (SFCL) are studied worldwide to be classified as resistive type or inductive type such as magnetic shielding type and dc reactor type. This Paper deals with an open core type SFCL, a kind of magnetic shielding type SFCL. We manufactured a 30 kVA open core type SFCL. It was modified from the old one with a rated power of 8 kVA. We stacked four superconducting tubes as magnetic shielding material and used the same primary winding as the old one. The experiments were performed with a maximum source voltage of 1 kV. The results show that the fault current in the source voltage of 1 kVrms was reduced to be about 105 Apeak, which was calculated to be about 22 % of the fault current in the system without an SFCL.

Performance inspection of smart superconducting fault current controller in radial distribution substation through PSCAD/EMTDC simulation

  • MassoudiFarid, Mehrdad;Shim, Jae Woong;Lee, Jiho;Ko, Tae Kuk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권4호
    • /
    • pp.21-25
    • /
    • 2013
  • In power grid, in order to level out the generation with demand, up-gradation of the system is occasionally required. This will lead to more fault current levels. However, upgrading all the protection instruments of the system is both costly and extravagant. This issue could be dominated by using Smart Fault Current Controller (SFCC). While the impact of Fault current Limiters (FCL) in various locations has been studied in different situations for years, the performance of SFCC has not been investigated extensively. In this research, SFCC which has adopted the characteristics of a full bridge thyristor rectifier with a superconducting coil is applied to three main locations such as load feeder, Bus-tie position and main feeder location and its behavior is investigated through simulation in presence and absence of small Distributed Generation unit (DG). The results show a huge difference in limiting the fault current when using SFCC.

YBCO film을 이용한 저항형 한류기의 안정적인 동작 조건 (Stabilized operating condition of resistive superconducting fault current limiter using YBCO film)

  • 최효상;현옥배;김혜림;황시돌;김상준
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2000년도 KIASC Conference 2000 / 2000년도 학술대회 논문집
    • /
    • pp.133-135
    • /
    • 2000
  • We fabricated resistive super- conducting fault current limiters (SFCL) based on YBCO thin films grown on a 2" diameter $Al_{2}$O_{3} substrate. The minimum quench current of the current minimum quench current of the current limiting element was about 8 $A_{peak}. This SFCL successfully controlled the fault current below 14.3 $A_{peak} at the voltage of 100$V_{rms}, which is otherwise to increase up to 141$A_{peak}. and the quench completion time is less than 3 msec. The temperature of the current limiting element rose to about 200K in 3 cycles after fault. The SFCL showed reproducible characteristics during hundreds times of repeated experiments.ents.

  • PDF

3상 전력계통의 1선 지락사고에 대한 초전도한류기의 동작특성 (Operating properties of superconducting fault current limiters with a sing1e line-to-ground fault in a three-phase system)

  • 최효상;현옥배;김혜림;황시돌;차상도
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.261-262
    • /
    • 2003
  • We performed unsymmetrical analysis of a single line-to-ground fault in a three-phase system. The current limiting elements were meander type YBCO stripes coated with Au shunt. When the fault occurred, short circuit currents were effectively limited within 1-2 msec after fault instant. The unsymmetrical rate of fault phase was distributed from 6.4 to 1.4 and most of the fault current flowed in the grounding line due to its direct grounding system.

  • PDF

MVDC 시스템의 적용을 위한 초전도 한류기의 설계 최적화 시뮬레이션 (Design Optimization Simulation of Superconducting Fault Current Limiter for Application to MVDC System)

  • 이석주
    • 한국산업정보학회논문지
    • /
    • 제29권3호
    • /
    • pp.41-49
    • /
    • 2024
  • 본 논문에서 중전압 직류 시스템(MVDC)의 적용을 위한 초전도 한류기(SFCL)의 설계 최적화를 위한 시뮬레이션 결과를 검증한다. 신재생 에너지의 증가와 계통 연계의 관점에 있어서, 기존의 송전망이나 배전망이 아닌 신재생 에너지망의 에너지 밸런싱을 위한 중전압 시스템이 연구 개발 실증 중에 있다. 특히 DC 배전망의 고장 전류는 빠른 시간 내에 큰 고장 전류를 차단해야 하기 때문에 초전도 한류기와 같은 전류 제한 시스템은 직류 차단기의 동작에 많은 이점이 있다. 이러한 초전도 한류기의 개발에 있어 시제작 및 평가 전에 유한 요소 해석(FEM)과 장시간의 설계 과정을 거쳐야 한다. 이러한 설계과정에서의 시간을 줄이기 위해 차원축소모델(ROM)을 활용하여 설계 결과를 학습하고 유한요소 해석 설계 결과와 동일한 결과를 검증함으로 기존 공학 모델의 제작 및 양산 등의 설계 시뮬레이션을 최적화하는 것 적용할 수 있다.