• Title/Summary/Keyword: Fault contingency

Search Result 34, Processing Time 0.018 seconds

An Application of Kohonen Neural Networks to Dynamic Security Assessment (전력계통 동태 안전성 평가에 코호넨 신경망 적용 연구)

  • Lee, Gwang-Ho;Park, Yeong-Mun;Kim, Gwang-Won;Park, Jun-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.6
    • /
    • pp.253-258
    • /
    • 2000
  • This paper presents an application of Kohonen neural networks to assess the dynamic security of power systems. The dynamic security assessment(DSA) is an important factor in power system operation, but conventional techniques have not achieved the desired speed and accuracy. The critical clearing time(CCT) is an attribute which provides significant information about the quality of the post-fault system behaviour. The function of Kohonen networks is a mapping of the pre-fault system conditions into the neurons based on the CCTs. The power flow on each line is used as the input data, and an activated output neuron has information of the CCT of each contingency. The trajectory of the activated neurons during load changes can be used in on-line DSA efficiently. The applicability of the proposed method is demonstrated using a 9-bus example.

  • PDF

Error Recovery Technique for Improving Reliability of Embedded Systems

  • Son, Sunghoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.6
    • /
    • pp.1-8
    • /
    • 2017
  • In this paper, we propose a fault tolerance technique which enables embedded systems to run without interruption while its operating system and tasks fail. In order to improve reliability, the proposed scheme makes an embedded system run as a virtual machine on virtual machine monitor. It also prepares a contingency virtual machine at which periodical backups of the embedded system are saved. When an error occurs in the main virtual machine, the corresponding standby virtual machine takes a role of the main virtual machine and continues its operation. Especially such backups and switches of virtual machines are performed with minor performance degradation by manipulating page table entries in virtual machine monitor. By conducting performance evaluation studies, we show that the proposed scheme makes embedded system robust against errors while it does not degrade the performance of the system significantly.

A Study on Multi-objective Optimal Power Flow under Contingency using Differential Evolution

  • Mahdad, Belkacem;Srairi, Kamel
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.53-63
    • /
    • 2013
  • To guide the decision making of the expert engineer specialized in power system operation and control; the practical OPF solution should take in consideration the critical situation due to severe loading conditions and fault in power system. Differential Evolution (DE) is one of the best Evolutionary Algorithms (EA) to solve real valued optimization problems. This paper presents simple Differential Evolution (DE) Optimization algorithm to solving multi objective optimal power flow (OPF) in the power system with shunt FACTS devices considering voltage deviation, power losses, and power flow branch. The proposed approach is examined and tested on the standard IEEE-30Bus power system test with different objective functions at critical situations. In addition, the non smooth cost function due to the effect of valve point has been considered within the second practical network test (13 generating units). The simulation results are compared with those by the other recent techniques. From the different case studies, it is observed that the results demonstrate the potential of the proposed approach and show clearly its effectiveness to solve practical OPF under contingent operation states.

Reliability analysis of the switch installation in the main feeder and in the radial/loop lateral feeders in distribution system (간선 및 분기선의 개폐기 설치 효과 분석(I))

  • Cho, Nam-Hun;O, Jae-Hyeong;Lee, Heung-Ho;Ha, Bok-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.79-82
    • /
    • 2002
  • The addition of switches to a distribution feeder does, in general, increase reliability by decreasing the duration of the outage of many to the customers on the feeder. To cover its service area so that feeder-level delivery reaches sufficiently close to all customers, feeders typically split their routes many times, in what is often called a lateral feeder. It is interesting to note, however, that the effectiveness of a switch is very much dependent on the types of lateral feeder. The types of lateral are classified into two types. The first is loop lateral feeder that can connect its load to an adjacent feeder through a tie line in case that a fault occurs in its feeder and it is laid out so that every feeder has complete fault backup through re-switching of its loads to other sources like a main feeder. The second is the radial lateral feeder cannot connect its load to an adjacent line, no provision is made for contingency backup of feeders. There are no other circuits in the radial lateral feeder form which to restore power. In this study, we evaluate the effectiveness of a switch installation between on the radial and loop lateral feeders to increase reliability by decreasing the duration of the outage. These results can help power utility to design the switch layouts on the radial and loop lateral feeder system.

  • PDF

Design of SPS in the Korean Power System Against Faults on 765 KV Lines

  • Park Jong-Young;Park Jong-Keun;Jang Byung-Tae
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.2
    • /
    • pp.132-137
    • /
    • 2005
  • In Korea, the protection systems against the instability of the nation's power system are insufficient in contrast with many other countries. In addition, there have just been studies carried out on detecting power system instability, while only a few studies pertaining to protection plans against instability exist. This paper focuses on systems to protect against the instability phenomena in the Korean power system. In this paper, we survey possible contingencies in the Korean power system and suggest outline and specs of the SPS (System Protection Scheme) against faults on the 765 kV line, based on simulations. It is concluded that event-based SPS for transient stability is appropriate for the Korean power system. In the simulations, the most severe contingency on the Korean power system is the fault on 765 kV transmission lines. If one of these lines is tripped by a fault, synchronism may be lost on the power plants near this line because of heavy power flow carried by them. In addition, undervoltage in the Metropolitan region is a serious problem in this case since this region receives about half its total power flow through these lines. In order to prevent a synchronism loss, some power plants have to be rejected according to the situations in the simulations.

Methodology for Determining of Generator Operation Point for Ensuring Voltage Stability Against Generator Faults in Jeju-Haenam HVDC System

  • Kang, Sang-Gyun;Seo, Sang-Soo;Lee, Byong-Jun;Joo, Joon-Young
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.54-60
    • /
    • 2010
  • This paper presents a new algorithm for determining generator operation point for maintaining stability considering generator faults in Jeju-Haenam HVDC system. As the HVDC system consumes reactive power for the transmission of active power substantially, compensation of reactive power is essential. And the HVDC system is operated on frequency control mode. That is to say, the HVDC system almost manages system frequency. Therefore, we recognized that the Jeju system could be unstable if the reactive power consumed by the HVDC is insufficient when out-of-step occurs with large generators. When the solution of power flow analysis does not converge due to the unstable system phenomenon, we have difficulty in establishing countermeasures as the post-fault information is not available. In this paper, for the purpose of overcoming this difficulty in establishing countermeasures, we introduce the CPF(Continuation Power Flow) algorithm. This paper suggests an algorithm for calculating the output limitation of the generator to maintain the stability in case of generator fault in the Jeju system.

Preventive and Emergency Control of Power System for Transient Stability Enhancement

  • Siddiqui, Shahbaz A.;Verma, Kusum;Niazi, K.R.;Fozdar, Manoj
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.83-91
    • /
    • 2015
  • This paper presents preventive and emergency control measures for on line transient stability (security) enhancement. For insecure operating state, generation rescheduling based on a real power generation shift factor (RPGSF) is proposed as a preventive control measure to bring the system back to secure operating state. For emergency operating state, two emergency control strategies namely generator shedding and load shedding have been developed. The proposed emergency control strategies are based on voltage magnitudes and rotor trajectories data available through Phasor Measurement Units (PMUs) installed in the systems. The effectiveness of the proposed approach has been investigated on IEEE-39 bus test system under different contingency and fault conditions and application results are presented.

A Study on the Protective Coordination of Distribution Automation System under Loop Operation (배전자동화 계통의 루프 운전시 보호협조에 관한 연구)

  • Lee, Hee-Tae;Moon, Jong-Fil;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1281-1286
    • /
    • 2009
  • As a general radial configuration of power distribution system, the various researches have being studied to change a radial configuration to network one such as smart, intelligent and micro grid for loop operation. If a radial configuration changes to network, protective coordination comes to the biggest problem. When a typical protective algorithm is applied to loop distribution system protection, the interrupted section is expanded, therefore, reliability grows worse. This paper presents the new protective method being able to apply to loop distribution system with Distribution Automation System (DAS) which separate the minimal faulted section. Through contingency analysis of the sustained and momentary fault, we analyzed the influence for radial configuration and loop configuration using interrupted area and proved the effectiveness of proposed method.

KOMPSAT SATELLITE LAUNCH AND DEPLOYMENT OPERATIONS

  • Baek, Myung-Jin;Chang, Young-Keun;Lee, Jin-Ho
    • Journal of Astronomy and Space Sciences
    • /
    • v.16 no.2
    • /
    • pp.199-208
    • /
    • 1999
  • In this paper, KOMPSAT satellite launch and deployment operations are discussed. The U.S. Taurus launch vehicle delivers KOMPSAT satellite into the mission orbit directly. Launch and deployment operations is monitored and controlled by several international ground stations including Korean Ground Station (KGS). After separation from launch vehicle, KOMPSAT spacecraft deploys solar array by on-board autonomous stored commands without ground inter-vention and stabilizes the satellite such that solar arrays point to the sun. Autonomous ground communication is designed for KOMPSAT for the early orbit ground contact. KOMPSAT space-craft has capability of handing contingency situation by on-board fault management design to retry deployment sequence.

  • PDF

Long-term Power System Operational Strategy in Korea : Experience And Perspectives during Electric Industry Restructuing Period (한국의 중장기 전력계통 운영 방안에 관한 고찰)

  • Kim, Jin-Yi;Lee, Jo-Lyeon;Kang, Myung-Jang
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.134-136
    • /
    • 2002
  • In April of 2000, the Korea Power Exchange(KPX) was introduced into Korea electricity market. The purpose of this paper is to describe how the system operator indicates operational risks between the transmission planning and the supply and demand growth to make the market "work" and manage the power system in real time. This paper describes the experiences of kpx about the indication of operational risks including, for example, contingency analysis, voltage profile and fault capacity of three-phase short current.