• 제목/요약/키워드: Fault analysis

Search Result 2,746, Processing Time 0.04 seconds

Integrated Fault Diagnosis Algorithm for Driving Motor of In-wheel Independent Drive Electric Vehicle (인휠 독립 구동 전기 자동차의 구동 모터 통합 고장 진단 알고리즘)

  • Jeon, Namju;Lee, Hyeongcheol
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.1
    • /
    • pp.99-111
    • /
    • 2016
  • This paper presents an integrated fault diagnosis algorithm for driving motor of In-wheel independent drive electric vehicle. Especially, this paper proposes a method that integrated the high level fault diagnosis and the low level fault diagnosis in order to improve a robustness and performance of the fault diagnosis system. The high level fault diagnosis is performed using the vehicle dynamics analysis and the low level fault diagnosis is carried using the motor system analysis. The validity of the high level fault diagnosis algorithms was verified through $Carsim^{(R)}$ and MATLAB/$Simulink^{(R)}$ cosimulation and the low level fault diagnosis's validity was shown by applying it to a MATLAB/$Simulink^{(R)}$ interior permanent magnet synchronous motor control system. Finally, this paper presents a fault diagnosis strategy by combining the high level fault diagnosis and the low level fault diagnosis.

Systematic Evaluation of Fault Trees using Real-Time Model Checker (실시간 모델 체커를 이용한 풀트 트리의 체계적 검증)

  • 지은경;차성덕;손한성;유준범;구서룡;성풍현
    • Journal of KIISE:Software and Applications
    • /
    • v.29 no.12
    • /
    • pp.860-872
    • /
    • 2002
  • Fault tree analysis is the most widely used saftly analysis technique in industry. However, the analysis is often applied manually, and there is no systematic and automated approach available to validate the analysis result. In this paper, we demonstrate that a real-time model checker UPPAAL is useful in formally specifying the required behavior of safety-critical software and to validate the accuracy of manually constructed fault trees. Functional requirements for emergency shutdown software for a nuclear power plant, named Wolsung SDS2, are used as an example. Fault trees were initially developed by a group of graduate students who possess detailed knowledge of Wolsung SDS2 and are familiar with safety analysis techniques including fault tree analysis. Functional requirements were manually translated in timed automata format accepted by UPPAAL, and the model checking was applied using property specifications to evaluate the correctness of the fault trees. Our application demonstrated that UPPAAL was able to detect subtle flaws or ambiguities present in fault trees. Therefore, we conclude that the proposed approach is useful in augmenting fault tree analysis.

The Development of Diesel Engine Room Fault Diagnosis System Using a Correlation Analysis Method (상관분석법에 의한 선박기관실 고장진단 시스템 개발)

  • Kim, Young-Il;Oh, Hyun-Kyung;Yu, Yung-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.253-259
    • /
    • 2006
  • There is few study which automatically diagnoses the fault from ship's monitored data. The bigger control and monitoring system is. the more important fault diagnosis and maintenance is to reduce damage caused by system fault. This paper proposes fault diagnosis system using a correlation analysis algorithm which is able to diagnose and forecast the fault from monitored data and is composed of fault detection knowledge base and fault diagnosis knowledge base. For all kinds of ship's engine room monitored data are classified with combustion subsystem, heat exchange subsystem and electric motor and pump subsystem, To verify capability of fault detection, diagnosis and prediction, FMS(Fault Management System) is developed by C++. Simulation by FMS is carried out with population data set made by the log book data of 2 months duration from a large full container ship of H shipping company.

The Development of Diesel Engine Room Fault Diagnosis SystemUsing a Correlation Analysis Method (상관분석법에 의한 선박기관실 고장진단 시스템 개발)

  • Kim, Young-Il;Oh, Hyun-Gyeong;Cheon, Hang-Chun;Yu, Yung-Ho
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.251-256
    • /
    • 2005
  • There is few study which automatically diagnose the fault from ship's monitored signal. The bigger control and monitoring system is, the more important fault diagnosis and maintenance is to reduce damage brought forth by system fault. This paper proposes fault diagnosis system using a correlation analysis algorithm which is able to diagnose and forecast the fault and is composed to fault detection knowledge base and fault diagnosis knowledge base. For this all kinds of ship's engine room monitored data are classified with combustion subsystem, heat exchange subsystem and electric motor and pump subsystem by analyzing ship's operation data. To verifying capability of fault detection, diagnosis and prediction, Fault Management System(FMS) is developed by C++. Simulation experiment by FMS is carried out with population data set made by log book data of 2 months duration from a large full container ship of H shipping company.

  • PDF

Analysis of Detection Method for Series Arc Fault Signal by using DWT (이산 웨이블렛 변환을 이용한 직렬 아크고장 신호 검출 방법 분석)

  • Bang, Sun-Bae;Kim, Chong-Min;Park, Chong-Yeun;Chung, Young-Sik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.3
    • /
    • pp.362-368
    • /
    • 2009
  • Electrical fires have been occurred continuously in spite of installing ELB. Therefore the concern with the electrical arc-fault that cause the fire has growing. This paper measured series arc fault currents by the method of arc generator test in UL standard 1699. The used analysis methods in this paper are three different ways using DWT(discrete wavelet transform) those are frequently used for the arc fault current signal analysis. The arc fault detection probability is 100 % by method using noise-energy/shoulder-duration ratio of approximation coefficient. As these results, the variation of noise-energy and shoulder-duration ratio of approximation coefficient are founded important factors for the analysis of arc fault.

Fault Tolerance Improvement of IPM Type BLDC Motor Considering Winding Configuration under a Stator Inter-Turn Fault Condition (Stator inter-turn fault 발생 시 권선 방식에 따른 IPM Type BLDC Motor의 Fault Tolerance 향상)

  • Kim, Hee-Woon;Yoon, Jin-Gyu;Hur, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.3
    • /
    • pp.524-530
    • /
    • 2011
  • This paper analyzes fault tolerance under a stator turn fault, according to the winding configuration. Improvement of torque characteristics and fault tolerance can be achieved by winding configuration without additional methods. And, torque characteristics and fault tolerance according to the winding configuration can be usually analyzed by analytical method. But, when the stator turn fault generates, compare to the steady-state, analysis of torque characteristics and fault tolerance using the analytical method is not accurate because it does not reflect influence in mutual inductance and magnetic non-linearity. Therefore, analysis of torque characteristics and fault tolerance has to be performed by using the numerical method under fault condition. This paper develops fault characteristics according to the winding configuration using the FEM-base model considered magnetic non-linearity. And, this paper suggests fault tolerance improvement according to the winding configuration, by the comparison of 8/12 and 10/12 models, under fault condition.

Analysis of fault characteristics in Catenary system for protection of AC feeding system (교류 급전시스템 보호를 위한 전차선로 고장특성 분석)

  • Jung, Ho-Sung;Park, Young;Kim, Joo-Rak;Kwon, Sam-Young;Park, Hyun-June
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1089-1090
    • /
    • 2006
  • This paper analyzes impedance convergence characteristics and harmonics of electric locomotives operation and fault condition. To simulate the various fault and operation condition, AT feeding system and various locomotives are modeled using PSCAD/EMTDC. Analysis shows that impedance are converged into protection area in the case of short fault between catenary and rail or catenary and feeder line but in the case of disconnection fault, impedance is rater bigger so protective relay can't detect the fault. Therefore more analysis of overload and high impedance fault caused disconnection fault is needed.

  • PDF

An Integrative Method of Fault Tree Analysis and Fault Modes and Effect Analysis for Security Evaluation of e-Teaching and Learning System (전자 교수학습 시스템의 보안성 평가를 위한 결함트리분석과 고장유형에 대한 영향분석의 통합적 방법)

  • Jin, Eun-Ji;Kim, Myong-Hee;Park, Man-Gon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.2 no.1
    • /
    • pp.7-18
    • /
    • 2013
  • These days, the teaching and learning system has been increasing for the rapid advancement of the information technologies. We can access education systems of good quality anytime, anywhere and we can use the individually personalized teaching and learning system depending on developing the wireless communication technology and the multimedia processing technology. The more the various systems develop, the more software security systems become important. There are a lot kind of fault analysis methods to evaluate software security systems. However, the only assessment method to evaluate software security system is not enough to analysis properly on account of the various types and characteristic of software systems by progressing information technology. Therefore, this paper proposes an integrative method of Fault Tree Analysis (FTA) and Fault Modes and Effect Analysis(FMEA) to evaluate the security of e-teaching and learning system as an illustration.

Analysis of Power System Wide-Area Blackout based on the Fault Cascading Scenarios (고장파급 시나리오에 기초한 광역정전 해석기법 연구)

  • Park, Chan-Eom;Kwon, Byeong-Gook;Yang, Won-Young;Lee, Seung-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.2
    • /
    • pp.155-163
    • /
    • 2008
  • This paper presents a novel framework for analysis of power system wide-area blackout based on so called fault cascading scenarios. For a given power system operating state, "triggering" faults or a "seed faults" are chosen based on the probabilities estimated from the hazard rates. The fault probabilities reflect both the load and the weather conditions. Effects of hidden failures in protection systems are also reflected in establishing the fault propagation scenarios since they are one of the major causes for the wide-area blackouts. A tree type data structure called a PS-BEST(Power System Blackout Event Scenario Tree) is proposed for construction of the fault cascading scenarios, in which nodes represent various power system operating states and the arcs are the events causing transitions between the states. Arcs can be either probabilistic or deterministic. For a given initial fault, the total probability of leading to wide-area blackout is estimated by aggregating the individual probability of each fault sequence route leading to wide-area blackout. A case study is performed on the IEEE RTS-79(24 bus) system based on the fault data presented by the North American Electrical Reliability Council(NERC). Test results demonstrate the potentials and the effectiveness of the proposed technique for the future wide-area blackout analysis.

A Method for Offline Inter-Turn Fault Diagnosis of Interior Permanent Magnet Synchronous Motor through the Co-Analysis (연동해석을 통한 영구자석 동기전동기의 오프라인 Inter-Turn 고장진단법)

  • Cho, Sooyoung;Oh, Ye Jun;Lee, GangSeok;Bae, Jae-Nam;Lee, Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.3
    • /
    • pp.365-373
    • /
    • 2018
  • In this paper, inter-turn fault diagnosis of the interior permanent magnet synchronous motor (IPMSM) is performed in offline state by linking the finite element analysis (FEA) tool and control simulation tool. In order to diagnose the inter-turn fault, it is important to select the current value to determine the fault. First, the basic principles for inter-turn fault diagnosis of IPMSM are explained and co-analysis model for fault diagnosis is constructed. Further, in order to select the appropriate high frequency voltage, the change of the current value to be judged as failure was analyzed at various voltage and frequency conditions, and the change of the current value according to the number of the failed windings was analyzed. Finally, the current value to be judged as failure is selected.