• Title/Summary/Keyword: Fault Safety

Search Result 814, Processing Time 0.026 seconds

안전성 확보를 위한 위험원 분석 기법간 상관관계에 대한 연구 (A study on the Correlation Hazard Analysis for Signaling System Safety)

  • 한찬희;이영수;안진;조우식
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.638-645
    • /
    • 2007
  • Computers are increasingly being introduced into safety and reliability critical systems. The safe and reliable operation of these systems cannot be taken for granted. Malfunctions of these systems can have potentially catastrophic consequences and they have already been involved in serious accidents. Software fault prevention, fault tolerance, fault removal and fault forecasting are the techniques to be used, implemented and verified for embedded software in critical systems as the contributors to safety and reliability of the software. To use them when developing a software product, a relationship must be established between them and the development processes, the methods and techniques to be used to develop software, as well as with the different product architectures. Railroad signaling system software is a safety-critical embedded software with realtime and high reliability requirements. The primary purpose of the safety management is to prevent the loss of lives or physical damages arising from potential hazards in the railroad signaling system. This study provides a systematic approach to analysis of potential hazards for their management during the system life cycle to assure the identification and definition of the most appropriate hazards.

  • PDF

Fault Tree Analysis 기법을 이용한 발파사고 분석 (An Analysis of Blasting Accidents by Fault Tree Analysis)

  • 서승록;이정훈
    • 대한인간공학회지
    • /
    • 제20권3호
    • /
    • pp.61-76
    • /
    • 2001
  • This study is for analyzing the explosion accidents in the tunnels, roads, subways, streets and various kinds of building construction area with the use of Fault Tree Analysis(FTA). based on the police Department and Guns & Explosives Safety Technology Association's researching materials. the explosion accidents have been investigated and analyzed between 1988 and 1977. As the result, we can find out that the majority of the explosion accidents in Korea is the accidents by flown stones(45.7%), like in Japan. So we make the research chart which is needed for analyzing the explosion accident, and then analyze these accidents systematically. using the investigation codes of the industrial accidents. After that, the FTA was performed on the accidents by flown stones. They result fromm non-observance of the safety rules, and lees knowledge of the safety and so on. Moreover several causes are combined and then the accidents are apt to happen. So according to the results of this study, for the protection of the explosion accidents, the specialized safety education is badly needed and the enough investigation of the places before the work along with the management for safety in working must be planned.

  • PDF

전기화재 예방을 위한 국가전기안전망 구축 방안 (A Plan for Construction of the National Electrical Safety Grid to Prevent the Fires Caused by Electrical Faults)

  • 임용배;전정채;박찬엄;배석명;고원식
    • 한국산학기술학회논문지
    • /
    • 제10권9호
    • /
    • pp.2267-2273
    • /
    • 2009
  • 본 논문에서는 부하전류, 누설전류, 아크고장과 같은 전기재해 위해 요소의 적절한 관리를 위해 유비쿼터스 환경에서 운영되는 실시간 감시 및 관리 시스템을 개발하고, 이를 이용한 국가전기안전망이 구축 방안이 제안되었다. 그리고 개발된 시스템과 제안된 안전망의 유용성 및 신뢰성을 확인하기 위해, 개발된 지능형 분전반을 전주한옥마을 28개 수용가에 설치하여 시범 운영하였다. 제안된 국가전기안전망이 일반용전기설비 수용가에 완전히 구축된다면, 전기안전에 대한 주요 관리가 일반 사용자에서 전문가에 의한 실시간 관리체계로 전환되는 효과가 있을 것이다. 그 결과 전기화재의 주요 원인인 과부하, 아크고장, 누전에 의한 화재가 예방될 수 있을 것이다.

FTA를 이용한 안전성 검증에 대한 고찰 (Safety Verification Method Based on Fault Tree Analysis)

  • 김은미
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 1998년도 가을 학술발표논문집 Vol.25 No.2 (1)
    • /
    • pp.582-584
    • /
    • 1998
  • 객체 지향 설계 명세를 대상으로한 시스템의 안전성에 대한 검사를 하여, 표(Table)조작에 기초한 검증법을 제안하였다[4]. 제안한 검증법에서는 전문 분야별로 준비된 안정성 기준(Safety Standard)과 노우하우(Knowhow)를 이용하여, 안전성에 관한 이벤트(Event)와 액션(Action)의 관계표를 작성하였다. 그러나, 많은 실제 개발 현장에서는 실제 존재하는 안전성 기준의 부족 등으로 인하여, 이러한 검증법의 기용이 어렵다는 문제점이 있다. 이에 본 논문에서는 신뢰성 분석의 한 방법인 FTA(Fault Tree Analysis)의 FT(Fault Tree)도를 이용한 안정성 체크리스트(Check list)를 작성하여, 이를 바탕으로 관계표를 작성하는 새로운 방법을 제안하고자 한다.

퍼지결함수분석을 이용한 교량시스템의 상태 및 안전성 평가 (The Condition and Safety Assessment using Fuzzy Fault Tree Analysis for Bridge System)

  • 이중빈;나기현;손용우;박주원
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.79-86
    • /
    • 1999
  • This paper aims to propose a method that helps maintenance engineers to evaluate the damage states of bridge systems by using a Fuzzy Fault Tree Analysis(FFTA). It may be stated that Fuzzy Fault Tree Analysis may be may useful for the systematic md rational condition and safety assessment for real bridge systems problems because the approach is able to effectively deal with all the related bridge system damages in terms of the linguistic variables that incorporate systematically experts experiences and subjective judgement.

  • PDF

Expert System을 이용한 전단기 고장 및 안전진단 시스템 구축 (Development of Shearing Machine Fault & Safety Diagnosis System Using Expert System)

  • 강경식;나승훈;정영득;박재현
    • 산업경영시스템학회지
    • /
    • 제20권44호
    • /
    • pp.475-483
    • /
    • 1997
  • Industrial safety management program consists of three part which is education, technology and control. The effectiveness of industrial safety control program rely on the ability of controlling hardware system, technology and software, training and management. How to design and develop the sharing machine fault and safety diagnosis system using expert system technique is presented on this paper.

  • PDF

무선충전 전기자동차 전력공급장치에서의 지락사고 특성 분석 (Analisys about the Earth Fault Characteristics in the Wireless Power Transmission System of the Electric Vehicle)

  • 정진수;한운기;박찬엄;송영상;임현성;조민호;유지연
    • 조명전기설비학회논문지
    • /
    • 제28권12호
    • /
    • pp.13-17
    • /
    • 2014
  • In this paper, the risk of electric shock is analyzed through analysis for characterization of potential distribution analysis and ground fault current analysis near the area where there are occurred a ground fault at electric vehicle wireless charging system using 20kHz. Studies for electric vehicle wireless charging system are in the works for development of efficiency increase, pickup shape design and communication module as a fundamental research step. But the research related to electrical safety and is still scarce state so that more studies are necessary to commercialize. As a result of analysis, it is verified that induced voltage is arisen more up to 45V near the a area of accident during ground fault and fault current has been maintained continuously without clearing fault condition by operating characteristics for circuit breaker and inverter.

다중 순환 최소 자승 및 성능 지수 기반 종방향 자율주행을 위한 적응형 구동기 고장 허용 제어 및 탐지 알고리즘 개발 (Development of Multiple RLS and Actuator Performance Index-based Adaptive Actuator Fault-Tolerant Control and Detection Algorithms for Longitudinal Autonomous Driving)

  • 오세찬;이종민;오광석;이경수
    • 자동차안전학회지
    • /
    • 제14권2호
    • /
    • pp.26-38
    • /
    • 2022
  • This paper proposes multiple RLS and actuator performance index-based adaptive actuator fault-tolerant control and detection algorithms for longitudinal autonomous driving. The proposed algorithm computes the desired acceleration using feedback law for longitudinal autonomous driving. When actuator fault or performance degradation exists, it is designed that the desired acceleration is adjusted with the calculated feedback gains based on multiple RLS and gradient descent method for fault-tolerant control. In order to define the performance index, the error between the desired and actual accelerations is used. The window-based weighted error standard deviation is computed with the design parameters. Fault level decision algorithm that can represent three fault levels such as normal, warning, emergency levels is proposed in this study. Performance evaluation under various driving scenarios with actuator fault was conducted based on co-simulation of Matlab/Simulink and commercial software (CarMaker).

The Characteristics of Arc Scattering and Fusing Current of Copper Wire in the Fault Process DB System of Cables in a PL Environment

  • Kim, Young-Seok;Shong, Kil-Mok;Kim, Sun-Gu
    • 조명전기설비학회논문지
    • /
    • 제22권3호
    • /
    • pp.52-58
    • /
    • 2008
  • The importance of. identifying the causes of electrical faults cannot be overstated because of the accidents caused by over-current that take place at the home, the office and electrical facilities due to misuse, poor products and system faults. It is necessary to gather objective, scientific data pertaining to electrical fault investigation in a product liability(PL) environment. To date, no database(DB) has been built concerning the accurate cause analysis of faultyfacilities. In this paper, accident hazard and arc scattering when over-current flows in copper wire was investigated. It was found that when over-current flows in a copper wire, the copper wire became heated and bent and beads were scattered around the wire with a flash. It was determinedthat the fusing current and time was related to the current rise per second. For example, when the current rise per second was largethe fusing current was higher than when the current rise per second was small, and the beads dispersed along a wide area. Fusing time, however, was shorter. The possibility of electrical fault became highest when the fusing current was higher. As the current rise per second is short, the dendrite structure is distributed in the surface of the copper wire. These experimental results can be utilized for a fault process DB system in the investigation and the prevention of electrical faults.

Numerical simulation on mining effect influenced by a normal fault and its induced effect on rock burst

  • Jiang, Jin-Quan;Wang, Pu;Jiang, Li-Shuai;Zheng, Peng-Qiang;Feng, Fan
    • Geomechanics and Engineering
    • /
    • 제14권4호
    • /
    • pp.337-344
    • /
    • 2018
  • The study of the mining effect influenced by a normal fault has great significance concerning the prediction and prevention of fault rock burst. According to the occurrence condition of a normal fault, the stress evolution of the working face and fault plane, the movement characteristics of overlying strata, and the law of fault slipping when the working face advances from footwall to hanging wall are studied utilizing UDEC numerical simulation. Then the inducing-mechanism of fault rock burst is revealed. Results show that in pre-mining, the in situ stress distribution of two fault walls in the fault-affected zone is notably different. When the working face mines in the footwall, the abutment stress distributes in a "double peak" pattern. The ratio of shear stress to normal stress and the fault slipping have the obvious spatial and temporal characteristics because they vary gradually from the higher layer to the lower one orderly. The variation of roof subsidence is in S-shape which includes slow deformation, violent slipping, deformation induced by the hanging wall strata rotation, and movement stability. The simulation results are verified via several engineering cases of fault rock burst. Moreover, it can provide a reference for prevention and control of rock burst in a fault-affected zone under similar conditions.