• 제목/요약/키워드: Fault Safety

검색결과 822건 처리시간 0.032초

A multi-layer approach to DN 50 electric valve fault diagnosis using shallow-deep intelligent models

  • Liu, Yong-kuo;Zhou, Wen;Ayodeji, Abiodun;Zhou, Xin-qiu;Peng, Min-jun;Chao, Nan
    • Nuclear Engineering and Technology
    • /
    • 제53권1호
    • /
    • pp.148-163
    • /
    • 2021
  • Timely fault identification is important for safe and reliable operation of the electric valve system. Many research works have utilized different data-driven approach for fault diagnosis in complex systems. However, they do not consider specific characteristics of critical control components such as electric valves. This work presents an integrated shallow-deep fault diagnostic model, developed based on signals extracted from DN50 electric valve. First, the local optimal issue of particle swarm optimization algorithm is solved by optimizing the weight search capability, the particle speed, and position update strategy. Then, to develop a shallow diagnostic model, the modified particle swarm algorithm is combined with support vector machine to form a hybrid improved particle swarm-support vector machine (IPs-SVM). To decouple the influence of the background noise, the wavelet packet transform method is used to reconstruct the vibration signal. Thereafter, the IPs-SVM is used to classify phase imbalance and damaged valve faults, and the performance was evaluated against other models developed using the conventional SVM and particle swarm optimized SVM. Secondly, three different deep belief network (DBN) models are developed, using different acoustic signal structures: raw signal, wavelet transformed signal and time-series (sequential) signal. The models are developed to estimate internal leakage sizes in the electric valve. The predictive performance of the DBN and the evaluation results of the proposed IPs-SVM are also presented in this paper.

자동차용 모바일 폰 충전 케이블의 발화 안전성에 관한 연구 (A Study on safety against a fire of charging cable for mobile phone for vehicle)

  • 권진욱;최규식;황명환
    • 대한안전경영과학회지
    • /
    • 제20권3호
    • /
    • pp.21-26
    • /
    • 2018
  • This paper describes result of a study on safety against a fire of charging cable for mobile phone for vehicle. Combustion on the USB cable in the car was happened while driving. Gas coming from the burning USB cable could be a reason which can make a secondary car accident since the driver also can be embarrassed while driving. In order to prevent a secondary car accident connected on the road, to research a reason why USB cable can emit gas and be burned in charging. We did simulation test with abnormal fault condition for the electronic component on the board in the USB cable. So we get the result from abnormal fault condition simulation test, for instance, shorted test for output terminal of 8 pin switch, shorted test for chip resistor after thermal aging in the condition $25^{\circ}C$, 93 % RH during 48 hours. To analysis the result of all test, Combustion on the USB cable was not the 8 pin but other electrical component such as a chip resistor. Therefore we guess that the reason for USB cable combustion in charging in a car was not 8 pin and a LED but another defective component.

LPG 가열로 및 건조로의 안전장치 설치에 따른 사고빈도에 관한 연구 (A Study on Accident Frequency by Installing Safety Devices in the LPG Heating and Drying Furnace)

  • 송동우;김기성;김충희;이성경;이수경
    • 한국가스학회지
    • /
    • 제19권4호
    • /
    • pp.49-54
    • /
    • 2015
  • 본 연구에서는 국내 가열로 건조로의 안전장치 유무에 따른 위험변화를 평가하기 위하여 FTA(Fault Tree Analysis)를 통하여 안전장치들의 사고발생 빈도수 도출 및 분석을 실시하였다. 국내 LPG 가열로 및 건조로의 안전장치의 국내 설치기준이 미비하고 가스 누출하여 체류할 수 있는 구조로 폭발의 위험을 가지고 있다. 안전장치는 다른 설비의 연소기 국내 기준과 NFPA를 바탕으로 4가지를 선정하였다. 안전장치 설치 전후의 사고발생 빈도감소효과를 각각 분석하였다. 이를 통해 국내 LPG 가열로 건조로의 가스누출 피해 방지를 위한 최소한의 안전장치를 제시하였다.

아크고장 검출기술의 개발 (Development of Arc-Fault Detection Technique)

  • 임용배;전정채;박찬엄;배석명
    • 한국산학기술학회논문지
    • /
    • 제10권8호
    • /
    • pp.1810-1816
    • /
    • 2009
  • 2007년도에 9,128건의 화재가 전기적인 원인에 의해서 발생되었고, 이들 화재에 의해 사망 29명과 부상 262명의 인명피해가 있었다. 아크고장은 전기화재의 주요 원인의 하나로, 일반적으로 높은 열을 발생시키며 쉽게 주변의 인화성물질을 점화시킨다. 그러나 기존의 차단기는 과전류, 단락전류, 누설전류에 대해서만 동작하기 때문에, 이에 대해서는 현재 특별한 보호책이 없는 실정이다. 본 논문은 직렬아크 고장전류에 의한 전선의 발화특성에 대한 실험에서 얻어진 결과를 통해 UL에서 제안하고 있는 기준이 국내의 현실에 적절하지 않음을 제시하였고, 이 결과를 기초로 개발된 기술의 동작특성 실험을 실시하여 아크고장회로를 보호할 수 있는지에 대한 신뢰성을 확인하였다. 모의실험을 통한 동작특성 분석결과, 개발된 아크고장 검출 기술을 적용하면 전기화재의 주요원인인 아크고장에 의한 화재를 현저히 저감시킬 수 있을 것으로 판단된다.

Magnetic Core Reactor for DC Reactor type Three-Phase Fault Current Limiter

  • Kim, Jin-Sa;Bae, Duck-Kweon
    • International Journal of Safety
    • /
    • 제7권2호
    • /
    • pp.7-11
    • /
    • 2008
  • In this paper, a Magnetic Core Reactor (MCR) which forms a part of the DC reactor type three-phase high-Tc superconducting fault current limiter (SFCL) has been developed. This SFCL is more economical than other types with three coils since it uses only one high-Tc superconducting (HTS) coil. When DC reactor type three-phase high-Tc SFCL is developed using just one coil, fewer power electronic devices and shorter HTS wire are needed. The SFCL proposed in this paper needs a power-linking device to connect the SFCL to the power system. The design concept for this device was sprang from the fact that the magnetic energy could be changed into the electrical energy and vice versa. Ferromagnetic material is used as a path of magnetic flux. When high-Tc superconducting DC reactor is separated from the power system by using SCRs, this device also limits fault current until the circuit breaker is opened. The device mentioned above was named Magnetic Core Reactor (MCR). MCR was designed to minimize the voltage drop and total losses. Majority of the design parameters was tuned through experiments with the design prototype. In the experiment, the current density of winding conductor was found to be $1.3\;A/mm^2$, voltage drop across MCR was 20 V and total losses on normal state was 1.3 kW.

FAULT TREE ANALYSIS OF KNICS RPS SOFTWARE

  • Park, Gee-Yong;Koh, Kwang-Yong;Jee, Eunk-Young;Seong, Poong-Hyun;Kwon, Kee-Choon;Lee, Dae-Hyung
    • Nuclear Engineering and Technology
    • /
    • 제40권5호
    • /
    • pp.397-408
    • /
    • 2008
  • This paper describes the application of a software fault tree analysis (FTA) as one of the analysis techniques for a software safety analysis (SSA) at the design phase and its analysis results for the safety-critical software of a digital reactor protection system, which is called the KNICS RPS, being developed in the KNICS (Korea Nuclear Instrumentation & Control Systems) project. The software modules in the design description were represented by function blocks (FBs), and the software FTA was performed based on the well-defined fault tree templates for the FBs. The SSA, which is part of the verification and validation (V&V) activities, was activated at each phase of the software lifecycle for the KNICS RPS. At the design phase, the software HAZOP (Hazard and Operability) and the software FTA were employed in the SSA in such a way that the software HAZOP was performed first and then the software FTA was applied. The software FTA was applied to some critical modules selected from the software HAZOP analysis.

Fault Tree Analysis(FTA)에 의한 Toluene저장 Tank의 폭발해석 (The Evaluation of Explosion For Toluene Storage Tank by Computer-Aided Fault Tree Analysis)

  • 정재희;이영섭
    • 한국안전학회지
    • /
    • 제3권2호
    • /
    • pp.5-16
    • /
    • 1988
  • This study is conducted to evaluate the explosion of tolune storage tank in the petrochemical plant by Fault Tree Analysis. The conclusions are as follows; 1) Fault Tree diagram and the required computer program for evaluation of explosion accident is developed. 2) The probability of the top event, explosion accident, is $1.5\;{\times}\;10^{-8}$ per year, so there is almost no possibility of explosion during the life cycle of tank. However, the probability of Gate 6 and Gate 7 is 8.8 per month, therefore, attention should be paid to them for accident prevention. 3) The number of minimal cut sets is 67 sets which are not calculated the probability of each set, because of the lack of computer capacity. All the minimal cut sets should be examined case by case. However, it is necessary to be paid attention to COM1, 126, 131, and COM4 in minimal cut sets, because the number of appearance is so high. 4) The number path sets is 70 sets which are not calculated the probability of each set, because of the lack of computer capacity. It is very useful to prepare safety checklist by using this minimal path sets. Also, the events which appear many times, 123, COM5, 139, 127 and 128, are very high in reliability.

  • PDF

Detection and Diagnosis Solutions for Fault-Tolerant VSI

  • Cordeiro, Armando;Palma, Joao C.P.;Maia, Jose;Resende, Maia J.
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1272-1280
    • /
    • 2014
  • This paper presents solutions for fault detection and diagnosis of two-level, three phase voltage-source inverter (VSI) topologies with IGBT devices. The proposed solutions combine redundant standby VSI structures and contactors (or relays) to improve the fault-tolerant capabilities of power electronics in applications with safety requirements. The suitable combination of these elements gives the inverter the ability to maintain energy processing in the occurrence of several failure modes, including short-circuit in IGBT devices, thus extending its reliability and availability. A survey of previously developed fault-tolerant VSI structures and several aspects of failure modes, detection and isolation mechanisms within VSI is first discussed. Hardware solutions for the protection of power semiconductors with fault detection and diagnosis mechanisms are then proposed to provide conditions to isolate and replace damaged power devices (or branches) in real time. Experimental results from a prototype are included to validate the proposed solutions.

근거리 지진에 의한 사장교의 동적응답해석에 관한 연구 (A Study on Dynamic Response Analysis of the Cable-Stayed Bridge Structure Subjected to Near Fault Ground Motions)

  • 한성호;권의성;신재철;방명석
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 봄 학술발표회 논문집
    • /
    • pp.439-446
    • /
    • 2004
  • In this study, the characteristic of the Near Fault Ground Motion which was not considered at the seismic design in our country and how the Near Fault Ground Motion affects the cable-stayed bridge which have long period is analyzed through the dynamic response analysis. So, the object of this study is following that it makes the data which can be utilized as the seismic safety evaluation in case of the cable-stayed bridge taken the near fault in the future.

  • PDF

Bi-directional fault analysis of evaporator inspection system

  • Kang, Dae-Ki;Kang, Jeong-Jin
    • International journal of advanced smart convergence
    • /
    • 제1권1호
    • /
    • pp.57-60
    • /
    • 2012
  • In this paper, we have performed a safety analysis on an automotive evaporator inspection system. We performed the bi-directional analysis on the manufacturing line. Software Fault Tree Analysis (SFTA) as backward analysis and Software Failure Modes, Effects, & Criticality Analysis (SFMECA) as forward analysis are performed alternately to detect potential cause-to-effect relations. The analysis results indicate the possibility of searching and summarizing fault patterns for future reusability.