• 제목/요약/키워드: Fault Monitoring System

검색결과 501건 처리시간 0.031초

The Design of Fault Tolerant Dual System and Real Time Fault Detection for Countdown Time Generating System

  • Kim, Jeong-Seok;Han, Yoo-Soo
    • 한국컴퓨터정보학회논문지
    • /
    • 제21권10호
    • /
    • pp.125-133
    • /
    • 2016
  • In this paper, we propose a real-time fault monitoring and dual system design of the countdown time-generating system, which is the main component of the mission control system. The countdown time-generating system produces a countdown signal that is distributed to mission control system devices. The stability of the countdown signal is essential for the main launch-related devices because they perform reserved functions based on the countdown time information received from the countdown time-generating system. Therefore, a reliable and fault-tolerant design is required for the countdown time-generating system. To ensure system reliability, component devices should be redundant and faults should be monitored in real time to manage the device changeover from Active mode to Standby mode upon fault detection. In addition, designing different methods for mode changeover based on fault classification is necessary for appropriate changeover. This study presents a real-time fault monitoring and changeover system, which is based on the dual system design of countdown time-generating devices, as well as experiment on real-time fault monitoring and changeover based on fault inputs.

Development of Acoustic Emission Monitoring System for Fault Detection of Thermal Reduction Reactor

  • Pakk, Gee-Young;Yoon, Ji-Sup;Park, Byung-Suk;Hong, Dong-Hee;Kim, Young-Hwan
    • Nuclear Engineering and Technology
    • /
    • 제35권1호
    • /
    • pp.25-34
    • /
    • 2003
  • The research on the development of the fault monitoring system for the thermal reduction reactor has been performed preliminarily in order to support the successful operation of the thermal reduction reactor. The final task of the development of the fault monitoring system is to assure the integrity of the thermal$_3$ reduction reactor by the acoustic emission (AE) method. The objectives of this paper are to identify and characterize the fault-induced signals for the discrimination of the various AE signals acquired during the reactor operation. The AE data acquisition and analysis system was constructed and applied to the fault monitoring of the small- scale reduction reactor, Through the series of experiments, the various signals such as background noise, operating signals, and fault-induced signals were measured and their characteristics were identified, which will be used in the signal discrimination for further application to full-scale thermal reduction reactor.

On-line Monitoring of Tribology Parameters and Fault Diagnosis for Disc Brake System

  • Yang Zhao-Jian;Kim Seock-Sam
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2003년도 학술대회지
    • /
    • pp.224-228
    • /
    • 2003
  • The basic Principles and methods of the on-line monitoring of tribology parameters (friction coefficient and wear allowance) and fault diagnosis for the hoist disc brake system were introduced, the method were based on the spring force and oil pressure of the brake system and the hoist kinematics parameters. The experiment on the monitoring and diagnosis of hoist brake system were carried out. The research results showed: the monitoring and diagnosis methods are feasible.

  • PDF

ART2 Neural Network Applications for Diagnosis of Sensor Fault in the Indoor Gas Monitoring System

  • Lee, In-Soo;Cho, Jung-Hwan;Shim, Chang-Hyun;Lee, Duk-Dong;Jeon, Gi-Joon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1727-1731
    • /
    • 2004
  • We propose an ART2 neural network-based fault diagnosis method to diagnose of sensor in the gas monitoring system. In the proposed method, using thermal modulation of operating temperature of sensor, the signal patterns are extracted from the voltage of load resistance. Also, fault classifier by ART2 NN (adaptive resonance theory 2 neural network) with uneven vigilance parameters is used for fault isolation. The performances of the proposed fault diagnosis method are shown by simulation results using real data obtained from the gas monitoring system.

  • PDF

WBI 환경에서의 서비스 모니터링 및 장애관리 시스템 구현 (Development of Service Monitoring and Fault-management System in WBI Environment)

  • 최용석
    • 컴퓨터교육학회논문지
    • /
    • 제8권5호
    • /
    • pp.119-128
    • /
    • 2005
  • 인터넷이 갖는 교육적 잠재력에 대한 인식이 확산됨에 따라 정부 차원이나 학교 현장에서 교수-학습을 위한 인터넷 활용을 적극적으로 진행하고 있으나 실제 인터넷 기반의 서비스를 사용하고 있는 시스템의 가용성에 대한 고려는 미흡한 상황이다. 본 논문에서는 가용성을 향상 시킬 수 있고 실제 교육현장의 시스템 관리 담당자들의 업무 부담을 줄일 수 있는 서비스 모니터링 및 장애 관리 시스템을 구현하였다. 구현된 시스템을 실제 WBI 서비스 환경에서 구동함으로써 서비스의 실시간 모니터링, 장애 발생시의 음성과 메일을 통한 장애 경고의 자동 생성, 그리고 계속적인 장애 발생시 관리자의 개입 없는 자동적인 복구가 효과적으로 수행됨을 보였다.

  • PDF

승강기식 타워주차설비 고장 모니터링 시스템 개발 (The development of fault monitoring system for lift type parking facility)

  • 이원태;차정섭;정영경;김관호;김박의
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.739-741
    • /
    • 1999
  • This paper describes the fault monitoring system for lift type tower parking facilities. This system consists of tower parking facility control panel and monitoring computer, and offers real-time monitoring of parking status and fault detection, and status data acquisition of tower parking system using graphic user interface.

  • PDF

차단기 트립코일 이상감지 장치 (A Trip Coil Fault Detection of Circuit Breaker)

  • 윤주혁;이종헌;박노식;이동희
    • 조명전기설비학회논문지
    • /
    • 제25권2호
    • /
    • pp.61-68
    • /
    • 2011
  • The circuit breaker of power distribution board is essential part for the protection of electrical disaster from load short, trouble of power system. For the normal operation of circuit breaker, trip coil of the circuit breaker can cut the mechanical contact of circuit breaker from the detection of power system troubles. This paper presents a design and experimental results of trip coil fault detection system for the real time monitoring of the circuit breaker. The designed system is consisted by the trip coil fault detector which is connected to the each circuit breaker and remote monitoring unit. The trip coil fault detector can detect the impedance and operating voltage of the trip coil, and the detected values are compared with the normal state. And the remote monitoring unit can be connected to the 32 channels of trip coil fault detectors by serial communication. From the designed system, the fault and normal states of the trip coil can be remotely monitored in real time. The designed system is verified by the practical circuit breaker of power distribution board. And the results shows the effectiveness of the designed system.

KOHONEN NETWORK BASED FAULT DIAGNOSIS AND CONDITION MONITORING OF PRE-ENGAGED STARTER MOTORS

  • BAY O. F.;BAYIR R.
    • International Journal of Automotive Technology
    • /
    • 제6권4호
    • /
    • pp.341-350
    • /
    • 2005
  • In this study, fault diagnosis and monitoring of serial wound pre-engaged starter motors have been carried out. Starter motors are DC motors that enable internal combustion engine (ICE) to run. In case of breakdown of a starter motor, internal combustion engine can not be worked. Starter motors have vital importance on internal combustion engines. Kohonen network based fault diagnosis system is proposed for fault diagnosis and monitoring of starter motors. A graphical user interface (GUI) software has been developed by using Visual Basic 6.0 for fault diagnosis. Six faults, seen in starter motors, have been diagnosed successfully by using the developed fault diagnosis system. GUI software makes it possible to diagnose the faults in starter motors before they occur by keeping fault records of past occurrences.

통계적 분석기법을 이용한 디젤기관의 고장진단 방법에 관한 연구 (The Fault Diagnosis Method of Diesel Engines Using a Statistical Analysis Method)

  • 김영일;오현경;유영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권2호
    • /
    • pp.247-252
    • /
    • 2006
  • Almost ship monitoring systems are event driven alarm system which warn only when the measurement value is over or under set point. These kinds of system cannot warn until signal is growing to abnormal state that the signal is over or under the set point. therefore cannot play a role for preventive maintenance system. This paper proposes fault diagnosis method which is able to diagnose and forecast the fault from present operating condition by analyzing monitored signals with present ship monitoring system without any additional sensors. By analyzing the data with high correlation coefficient(CC), correlation level of interactive data can be defined. Knowledge base of abnormal detection can be built by referring level of CC(Fault Detection CC. FDCC) to detect abnormal data among monitored data from monitoring system and knowledge base of diagnosis built by referring CC among interactive data for related machine each other to diagnose fault part.

통계적분석기법을 이용한 디젤기관의 고장진단 방법에 관한 연구 (The Fault Diagnosis Method of Diesel Engines Using a Statistical Analysis Method)

  • 김영일;오현경;천행춘;유영호
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.281-286
    • /
    • 2005
  • Almost ship monitoring systems are event driven alarm system which warn only when the measurement value is over or under set point. These kinds of system cannot warn while signal is growing to abnormal state until the signal is over or under the set point and cannot play a role for preventive maintenance system. This paper proposes fault diagnosis method which is able to diagnose and forecast the fault from present operating condition by analyzing monitored signals with present ship monitoring system without additional sensors. By analyzing this data having high correlation coefficient(CC), correlation level of interactive data can be understood. Knowledge base of abnormal detection can be built by referring level of CC(Fault Detection CC, FDCC) to detect abnormal data among monitored data from monitoring system and knowledge base of diagnosis built by referring CC among interactive data for related machine each other to diagnose fault part.

  • PDF