• Title/Summary/Keyword: Fault Diagnostic

Search Result 273, Processing Time 0.021 seconds

A Study on the Fault Diagnosis Applied to the Grinding Power Signals (연삭 동력신호를 응용한 결함진단에 관한 연구)

  • 곽재섭
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.4
    • /
    • pp.108-116
    • /
    • 2000
  • Undesired trouble such as chatter vibration and burning on the ground surface appears frequently in the cylindrical plunge grinding process. Establishment of a credible fault diagnostic system for the grinding process is the major purpose of this study. Power signals generated during the grinding operation were sampled and analyzed to determine the relationship between grinding troubles and behavior of signal changes. In addition, a neural network was optimized with a momentum coefficient a learning rate, and a structure of the hidden layer through the iterative learning process. Based on the established system, success rates of the trouble recognition were verified.

  • PDF

On the Fault Diagnosis in a Redundant Digital System (Redundant Digital System에서의 고장진단에 관한 연구)

  • 김기섭;김정선
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.9 no.2
    • /
    • pp.70-76
    • /
    • 1984
  • In this paper, a functional m-redundant system, which is m-fault tolerant, is defined based on the graph-theory. This system is designed to be t(t$\geq$m) fault-diagnosable by comparing its unit's outcomes without additive test functions, so, the system down for diagnosis is not needed. The diagnostic model for this system is presented. It is to avail the redundancy of the system effectively. It is shown that this model can be converted into Preparata's model. Thus, the diagnostic characteristics of a functional m-redundant system is analyzed by the method originated by Preparata et al.

  • PDF

Fault Detection and Diagnosis of a Constant Volume Air Handling Unit by a Fuzzy Algorithm (퍼지 알고리즘을 이용한 정풍량 공조기의 고장 감지 및 진단)

  • Han Doyoung;Kim Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.444-451
    • /
    • 2005
  • The fault detection and diagnosis technology may be applied in order to decrease the energy consumption and the maintenance cost of an air-conditioning system. In this study, partial faults for fans, coils, dampers, and sensors of a constant volume air handling unit were considered. A fuzzy algorithm was developed to detect and diagnose these faults. Diagnostic results by the fuzzy algorithm were compared with those by the model reference algorithm. The fuzzy algorithm showed better results in diagnostic accuracies.

A Fault Diagnostic Expert System for Silicone Oil-filled Transformer Using Dissolved Gas Analysis (유중가스분석법을 이용한 실리콘 유입변압기 고장진단 전문가 시스템)

  • Moon, Jong-Fil;Kim, Jae-Chul;Choi, Joon-Ho;Jun, Young-Jae;Kim, Oun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.374-376
    • /
    • 2001
  • In this paper, we developed the fault diagnostic expert system of silicone-immersed transformer using dissolved gas analysis. The knowledge base module consists of the knowledge using the rule: if Then . The inference engine uses the fuzzy rule for the management of uncertainty of the boundary and rule and derivate the Belief and Plausibility of the normality and fault using Dempster-Shafer theory. The expert system is connected to the database and it can manages the history of gas-data of the transformer.

  • PDF

A Study on the robust fault diagnosis and fault tolerant control method for the closed-loop control systems (폐회로 제어시스템의 강인한 고장진단 및 고장허용제어 기법 연구)

  • Lee, Jong-Hyo;Lyou, Joon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.3 no.1
    • /
    • pp.138-145
    • /
    • 2000
  • This paper presents a robust fault diagnosis and fault tolerant control method for the control systems in closed-loop affected by unknown inputs or disturbances. The fault diagnostic scheme is based on the disturbance-decoupled state estimation using a 2-stage state observer for state, actuator bias and sensor bias. The estimated bias show the occurrence time, location and type of the faults directly. The estimated state is used for state feedback to achieve fault tolerant control against the faults. Simulation results show that the method has definite fault tolerant ability against actuator and sensor faults, moreover, the faults can be detected on-line, isolated and estimated simultaneously.

  • PDF

An Adaptive Unknown Input Observer based Actuator Fault Diagnosis (적응 미지입력 관측기에 근거한 구동기 고장의 식별)

  • Park, Tae-Geon;Ryu, Ji-Su;Lee, Kee-Sang
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.665-667
    • /
    • 1999
  • An adaptive algorithm is presented for diagnosis of actuator faults. The concept of unknown input decoupling is combined with an adaptive observer, leading to an adaptive diagnostic observer, which has the robustness property in the presence of an unmeasurable term such as uncertainties. The observation error equation for the adaptive diagnostic observer does not depend on the effect of uncertainties and used to construct an adaptive diagnostic algorithm that provides the estimates of the gains of actuators, which can be obtained directly via the use of the augmented error technique. The simulation results indicate that the proposed algorithm is more realistic in the sense that better robustness properties can be assured without knowledge about uncertainties and is potentially useful in the development of a fault tolerant control system.

  • PDF

Development of Expert System for the Fault Diagnosis of Chemical Facility System (화학설비 시스템의 이상고장진단을 위한 Expert System의 개발)

  • Oh, Jae-Eung;Shin Jun;Shin, Ki-Hong;Kim, Doo-Hwan;Kim, Woo-Taek;Lee, Chung-Hwi
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.05a
    • /
    • pp.639-642
    • /
    • 2000
  • Chemical facility system have dangerous elements that can injure the human like an explosion and a fire, gas poisoning by a leakage of the harmful chemical material. In addition to a vibration of the machine occurs the leakage. Therefore, the chemical factory requires for periodic monitoring of the vibration. But, until now, the operator has executed a monitoring of the machine by the senses. So, the diagnostic expert system by which the operator can judge easily and expertly a condition of the machine is developed. This paper describes the structure of diagnostic system and the diagnostic algorithm using fuzzy inference

  • PDF

A Study on the Implementation of a Control System with Dual Structure and Its Reliability Analysis (이중구조를 갖는 제어시스템의 구현과 신뢰도 분석에 관한 연구)

  • ;;;Zeung Nam Bien
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.9
    • /
    • pp.1351-1363
    • /
    • 1990
  • In this paper, a reliable control system structured with dual CPU modules and dual I/O modules is implemented as a means of achieving a highly reliable fault tolerant control system. For this, faults in the system modules are first examined, and a fault detection technique consisting of self diagnostic, comparison process, and exception processing is applied. Self diagnostic is used to locate which components in the modules have been failed, while comparison process is to cmpare control outputs computed by both CPU modules and protect the plant from malfunction by blocking failed control outputsin advance. Finally exception processing is used to determine the faults that are not detected immediately by the self diagnostic and comparison process, e.g. bus error processing when acknowledge signal for data transfer is not activeted in the I/O modules. Also reliability analysis is conducted for the discrete time Markov model with dual structure. It is shown quantitatively that the reliability is improved in the control system with dual structure in comparison with a system with single module structure.

  • PDF

Fault Diagnosis Management Model using Machine Learning

  • Yang, Xitong;Lee, Jaeseung;Jung, Heokyung
    • Journal of information and communication convergence engineering
    • /
    • v.17 no.2
    • /
    • pp.128-134
    • /
    • 2019
  • Based on the concept of Industry 4.0, various sensors are attached to facilities and equipment to collect data in real time and diagnose faults using analyzing techniques. Diagnostic technology continuously monitors faults or performance degradation of facilities and equipment in operation and diagnoses abnormal symptoms to ensure safety and availability through maintenance before failure occurs. In this paper, we propose a model to analyze the data and diagnose the state or failure using machine learning. The diagnosis model is based on a support vector machine (SVM)-based diagnosis model and a self-learning one-class SVM-based diagnostic model. In the future, it is expected that this model can be applied to facilities used in the entire industry by applying the actual data to the diagnostic model proposed in this paper, conducting the experiment, and verifying it through the model performance evaluation index.

Fault Diagnosis of Screw type Air Compressor (스크루형 공기압축기의 고장진단)

  • Bae Yong-hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.7
    • /
    • pp.1092-1100
    • /
    • 2004
  • This paper describes the application of fault tree technique to analyze of compressor failure. Fault tree analysis technique involves the decomposition of a system into the specific form of fault tree where certain basic events lead to a specified top event which signifies the total failure of the system. In this research. fault trees for failure analysis of screw type air compressor are made. This fault trees are used to obtain minimal cut sets from system failure and system failure rate for the top event occurrence can be calculated. It is Possible to estimate air compressor reliability by using constructed fault trees through compressor failure example. It is Proved that FTA is efficient to investigate the compressor failure modes and diagnose system.