• Title/Summary/Keyword: Fatigue tests

Search Result 1,326, Processing Time 0.029 seconds

HIGH HEAT FLUX TEST WITH HIP BONDED 35X35X3 BE/CU MOCKUPS FOR THE ITER BLANKET FIRST WALL

  • Lee, Dong-Won;Bae, Young-Dug;Kim, Suk-Kwon;Jung, Hyun-Kyu;Park, Jeong-Yong;Jeong, Yong-Hwan;Choi, Byung-Kwon;Kim, Byoung-Yoon
    • Nuclear Engineering and Technology
    • /
    • v.42 no.6
    • /
    • pp.662-669
    • /
    • 2010
  • To develop the manufacturing methods for the blanket first wall (FW) of the International Thermonuclear Experimental Reactor (ITER) and to verify the integrity of the joint, Be/Cu mockups were fabricated and tested at the KoHLT-1 (Korea Heat Load Test facility), a graphite heater facility located at the Korea Atomic Energy Research Institute (KAERI). Since Be and Cu joining is the focus of the present study, the fabricated mockups had a CuCrZr heat sink joined with three Be tiles as an armor material, unlike the original ITER blanket FW, which has a stainless steel structure and coolant tubes. Hot isostatic pressing (HIP) was carried out at $580^{\circ}C$ and 100 MPa for 2 hours as the method for Be/Cu joining. Three interlayers, namely, $1{\mu}mCr/10{\mu}mCu$, $1{\mu}mTi/0.5{\mu}mCr/10{\mu}mCu$, and $5{\mu}mTi/10{\mu}mCu$ were applied as a coating to the Be tiles by a physical vapor deposition (PVD) method. A shear test was performed with the specimens, which were fabricated by the same methods as those used to fabricate the mockups. The average values were 125 MPa to 180 MPa, and the samples with the $1{\mu}mCr/10{\mu}mCu$ interlayer showed the lowest value. No defect or delamination was found in the joints of the mockups by the developed ultrasonic test using a flat-type probe with a 10 MHz frequency and a 0.25 inch diameter. High heat flux (HHF) tests were performed at $1.0\;MW/m^2$ heat flux for each mockup using the given conditions, and the results were analyzed by ANSYS-CFX code. For the test criteria, an expected fatigue lifetime about 1,000 cycles was obtained by analysis with ANSYS-mechanical code. Mockups using the interlayers of $1{\mu}mTi/0.5{\mu}mCr/10{\mu}mCu$ and $5{\mu}mTi/10{\mu}mCu$ survived up to 1,100 cycles over the required number of cycles. However, one of the Be tiles in the other two mockups using the $1{\mu}mCr/10{\mu}mCu$ interlayer was detached during the screening test, and others were detached by discharge after 862 cycles. The integrity of the joints using the proposed interlayers was proven by the HHF test, but the other interlayer requires more study before it can be used for the joining of Be to Cu. Moreover, it was confirmed that the measured temperatures agreed well with the analysis temperatures, which were used to estimate the lifetime and that the developed facility showed its capability of the long time operation.

Design and Strength Analysis of a Mast and Mounting Part of Dummy Gun for Multi-Mission Unmanned Surface Vehicle (복합임무 무인수상정의 마스트 및 특수임무장비 장착부 설계 및 강도해석)

  • Son, Juwon;Kim, Donghee;Choi, Byungwoong;Lee, Youngjin
    • The Journal of Korean Institute of Information Technology
    • /
    • v.16 no.11
    • /
    • pp.51-59
    • /
    • 2018
  • The Multi-Mission Unmanned Surface Vehicle(MMUSV), which is manufactured using glass Fiber Reinforced Plastic(FRP) material, is designed to perform a surveillance and reconnaissance on the sea. Various navigation sensors, such as RADAR, RIDAR, camera, are mounted on a mast to perform an autonomous navigation. And a dummy gun is mounted on the deck of the MMUSV for a target tracking and disposal. It is necessary to analyze a strength for structures mounted on the deck because the MMUSV performs missions under a severe sea state. In this paper, a strength analysis of the mast structure is performed on static loads and lateral external loads to verify an adequacy of the designed mast through a series of simulations. Based on the results of captive model tests, a strength analysis for a heave motion of the mast structure is conducted using a simulation tool. Also a simulation and fatigue test for a mounting part between the MMUSV and the dummy gun are performed using a specimen. The simulation and test results are represented that a structure of the mast and mounting part of the dummy gun are appropriately designed.he impact amount are performed through simulation and experiments.

Experimental Study on Reducing Motion of Circular Cylinder in Currents (조류 중 원형실린더 형상 구조물의 거동감소를 위한 실험적 연구)

  • Lim, Jae Hwan;Jo, Hyo Jae;Hwang, Jae Hyuk;Kim, Jae Heui;Lee, Tae Kyung;Choi, Yoon Woo;Lee, Min Jun;Kim, Young Kyu
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.4
    • /
    • pp.350-357
    • /
    • 2019
  • The development of marine technology is expected to increase the demand for marine plants because of increasing oil prices. Therefore, there is also expected to be an increase in the demand for cylindrical structures such as URF (umbilical, riser, flowline) structures and spars, which are used operating in various seas. However, a cylindrical structure experiences vortex induced motion (VIM) in a current. In particular, for risers and umbilicals, it is important to identify the characteristics of the VIM because interference between structures can occur. In addition, various studies have been conducted to reduce VIM because it is the cause of fatigue damage to structures. The helical strake, which was developed for VIM reduction, has an excellent VIM reduction performance, but is difficult to install on structures and has a negative effect on heave motion. Therefore, the purpose of this study was to supplement the shortcomings of the helical strake and develop a high-performance reduction device. In the reduction device developed in this study, a string is placed around the structure inside the flow, causing vibration. The vibration of this string causes a small turbulence in the flow field, reducing the VIM effect on the structure. Finally, in this study, the 2-DOF motion characteristics of models without a suppression device, models with a helical strake, and models with a string were investigated, and their reduction performances were compared through model tests.

An Experimental Study on the Biomechanical Effectiveness of Bone Cement-Augmented Pedicle Screw Fixation with Various Types of Fenestrations

  • Yoon, Sang Hoon;Lee, Sang Hyung;Jahng, Tae-Ahn
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.6
    • /
    • pp.779-789
    • /
    • 2022
  • Objective : To analyze the effects of the number and shape of fenestrations on the mechanical strength of pedicle screws and the effects of bone cement augmentation (BCA) on the pull-out strength (POS) of screws used in conventional BCA. Methods : For the control group, a conventional screw was defined as C1, a screw with cannulated end-holes was defined as C2, a C2 screw with six pinholes was defined as C3, and the control group type was set. Among the experimental screws, T1 was designed using symmetrically placed thru-hole type fenestrations with an elliptical shape, while T2 was designed with half-moon (HM)-shaped asymmetrical fenestrations. T3 and T4 were designed with single HM-shaped fenestrations covering three pitches and five pitches, respectively. T5 and T6 were designed with 0.6-mm and 1-mm wider fenestrations than T3. BCA was performed by injecting 3 mL of commercial bone cement in the screw, and mechanical strength and POS tests were performed according to ASTM F1717 and ASTM F543 standards. Synthetic bone (model #1522-505) made of polyurethane foam was used as a model of osteoporotic bone, and radiographic examinations were performed using computed tomography and fluoroscopy. Results : In the fatigue test, at 75% ultimate load, fractures occurred 7781 and 9189 times; at 50%, they occurred 36122 and 82067 times; and at 25%, no fractures occurred. The mean ultimate load for each screw type was 219.1±52.39 N for T1, 234.74±15.9 N for T2, 220.70±59.23 N for T3, 216.45±32.4 N for T4, 181.55±54.78 N for T5, and 216.47±29.25 N for T6. In comparison with C1, T1, T2, T3, T4, and T6 showed significantly different ultimate load values (p<0.05). However, when the values for C2 and the fenestrated screws were evaluated with an unpaired t test, the ultimate load value of C2 significantly differed only from that of T2 (p=0.025). The ultimate load value of C3 differed significantly from those of T1 and T2 (C3 vs. T1 : p=0.048; C3 vs. T2 : p<0.001). Linear correlation analysis revealed a significant correlation between the fenestration area and the volume of bone cement (Pearson's correlation coefficient r=0.288, p=0.036). The bone cement volume and ultimate load significantly correlated with each other in linear correlation analysis (r=0.403, p=0.003). Conclusion : Fenestration yielded a superior ultimate load in comparison with standard BCA using a conventional screw. In T2 screws with asymmetrical two-way fenestrations showed the maximal increase in ultimate load. The fenestrated screws can be expected to show a stable position for the formation of the cement mass.

Awareness of the Causes of Drug-Induced Liver Injury: A Case of Hepatotoxicity Resulting from Antipsychotics (사례로 본 한방임상에서 양약으로 인한 약인성간손상에 대한 인식 필요성)

  • Chang-gue Son
    • The Journal of Internal Korean Medicine
    • /
    • v.44 no.4
    • /
    • pp.751-756
    • /
    • 2023
  • Objective: This study attempts to increase awareness of hepatotoxicity caused by antipsychotic drugs and to provide updated information on drug-induced liver injury (DILI) to physicians in Korean medicine (KM) clinics. Methods: This study presents a detailed case of a female patient diagnosed with DILI attributed to antipsychotic drugs, highlighting the improvement observed through laboratory findings. Results: A 56-year-old female patient with underlying disorders, including mixed connective tissue disease and depression, was under medical care. One day, she reported experiencing intense fatigue and distressing sensations, prompting the author to order blood tests. The levels of AST and ALT were significantly elevated by more than 2.5-fold, indicating hepatocellular DILI. The RUCAM score for antipsychotic drugs was 9, as no other medications, including herbal medicine, were being taken. Upon discontinuation of the antipsychotic drugs, the patient's laboratory findings returned to normal levels within 2 weeks, accompanied by a recovery of subjective symptoms. Conclusion: This study presents a noteworthy case of hepatotoxicity caused by antipsychotic drugs, serving as an illustrative example that highlights the crucial need for awareness among doctors of KM in clinical settings.

THE EFFECT OF CYCLIC LOADING ON THE RETENTIVE STRENGTH OF FULL VENEER CROWNS (반복 하중이 Full veneer crown의 유지력에 미치는 영향에 관한 연구)

  • Kim, Ki-Youn;Lee, Sun-Hyung;Chung, Hun-Young;Yang, Jae-Ho;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.583-594
    • /
    • 2000
  • Dislodgement of a crown or extension bridge and the loosening of a retainer of a bridge is a serious clinical problem in fixed restoration. Generally these problems are considered to be associated with deformation of the restoration. During biting, the restoration is subjected to complex forces and deforms considerably within the limit of its elasticity. Deformation of the restoration under the occlusal force induces excessive stress in the cement film, which then leads to the cement fracture. Such a fracture may eventually cause loss of the restoration. Because most of the past retention tests for full veneer crown were done without fatigue loading, they were not exactly simulating intraoral environment. And the purpose of this study was to evaluate the effect of cyclic cantilever loading on the retentive strength of full veneer crowns depending on different type of cements and taper of prepared abutment. Steel dies with $8^{\circ}\;or\;16^{\circ}$ convergence angle were fabricated through milling and crowns with the same method. These dies and crowns were divided into 8 groups. Group 1 : $16^{\circ}$ taper die, cementation with zinc phosphate cement, without loading Group 2 : $16^{\circ}$ taper die, cementation with zinc phosphate cement, with loading Group 3 : $8^{\circ}$ taper die, cementation with zinc phosphate cement, without loading Group 4 : $8^{\circ}$ taper die, cementation with zinc phosphate cement, with loading Group 5 : $16^{\circ}$ taper die, cementation with Panavia 21, without loading Group 6 : $16^{\circ}$ taper die, cementation with Panavia 21, with loading Group 7 : $8^{\circ}$ taper die, cementation with Panavia 21 without loading Group 8 : $8^{\circ}$ taper die, cementation with Panavia 21, with loading After checking the fit of die and crown, the luting surface of dies and inner surface of crowns were air-abraded for 10 seconds. The crowns were cemented to the dies, with cements mixed according to the manufacturer's recommendations. A static load of 5kg was then applied for 10 minutes with static loading device. Twenty-four hours later, group 1, 3, 5, 7 were only thermocycled, group 2, 4, 6, 8 were subjected to cyclic loading after thermocycling. Retentive tests were performed on the Instron machine. From the finding of this study, the following conclusions were obtained 1. Panavia 21 showed significantly higher retentive strength than zinc phosphate cement for all groups (p<0.05). 2. There was a significant difference in the retentive strength between $8^{\circ}\;and\;16^{\circ}$ taper for zinc phosphate cement(p<0.05), but no significant difference for Panavia 21 (p>0.05). 3. Cyclic loading significantly decreased the retentive strength for all groups(p<0.05). 4. For zinc phosphate cement, there was 35% reduction of the retentive strength after loading in the $16^{\circ}$ taper die, 25% in the $8^{\circ}$ taper die, and for Panavia 21, 21% in the $16^{\circ}$ taper die, 18% in the $8^{\circ}$ taper die.

  • PDF

Characteristics of Flexible Transparent Capacitive Pressure Sensor Using Silver Nanowire/PEDOT:PSS Hybrid Film (은나노와이어·전도성고분자 하이브리드 필름을 이용한 유연 투명 정전용량형 압력 센서의 특성)

  • Ahn, Young Seok;Kim, Wonhyo;Oh, Haekwan;Park, Kwangbum;Kim, Kunnyun;Choa, Sung-Hoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.3
    • /
    • pp.21-29
    • /
    • 2016
  • In this paper, we developed a flexible transparent capacitive pressure sensor which can recognize X and Y coordinates and the size of force simultaneously by sensing a change in electrical capacitance. The flexible transparent capacitive pressure sensor was composed of 3 layers which were top electrode, pressure sensing layer, and bottom electrode. Silver nanowire(Ag NW)/poly(3,4-ethylenedioxythiophene): poly(styrenesulfonate) (PEDOT:PSS) hybrid film was used for top and bottom flexible transparent electrode. The fabricated capacitive pressure sensor had a total size of 5 inch, and was composed of 11 driving line and 19 sensing line channels. The electrical, optical properties of the Ag NW/PEDOT:PSS and capacitive pressure sensor were investigated respectively. The mechanical flexibility was also investigated by bending tests. Ag NW/PEDOT:PSS exhibited the sheet resistance of $44.1{\Omega}/square$, transmittance of 91.1%, and haze of 1.35%. Notably, the Ag NW/PEDOT:PSS hybrid electrode had a constant resistance change within a bending radius of 3 mm. The bending fatigue tests showed that the Ag NW/PEDOT:PSS could withstand 200,000 bending cycles which indicated the superior flexibility and durability of the hybrid electrode. The flexible transparent capacitive pressure sensor showed the transmittance of 84.1%, and haze of 3.56%. When the capacitive pressure sensor was pressed with the multiple 2 mm-diameter tips, it can well detect the force depending on the applied pressure. This indicated that the capacitive pressure sensor is a promising scheme for next generation flexible transparent touch screens which can provide multi-tasking capabilities through simultaneous multi-touch and multi-force sensing.

A Study of Upper Airway Resistance Syndrome : Clinical and Polysomnographic Characteristics (상기도저항 증후군에 대한 연구 : 임상 및 수면다원검사 특징)

  • Yang, Chang-Kook;Clerk, Alex
    • Sleep Medicine and Psychophysiology
    • /
    • v.3 no.2
    • /
    • pp.32-42
    • /
    • 1996
  • Objectives : Upper airway resistance syndrome(UARS) is a sleep-related breathing disorder characterized by abnormal negative intrathoracic pressure during sleep. Abnormally increased negative intrathoracic pressure results in microarousal and sleep fragmentation which underlay UARS-associated complaints of daytime fatigue and sleepiness. Although daytime dysfunction in patients with UARS is comparable to that of sleep apnea syndrome, UARS has been relatively unnoticed in clinical setting. That is why UARS is apt to be excluded in diagnosing of sleep-related breathing disorders since its respiratory disturbance index and arterial oxygen saturation are within normal limits. The current study presents a summary of clinical and polysomnographic characteristics found in patients with UARS. The present study aims (1) to explore characteristics of patients diagnosed with UARS, (2) to characterize the polysomnographic findings of UARS patients, and (3) to enhance the understanding of UARS through those clinical and laboratory characteristics. Methods : This was a retrospective study of 20 UARS patients (male 15, female 5) and 30 obstructive sleep apnea (OSA) patients (male 21, female 9) at the Stanford Sleep Disorders Clinic. We diagnosed patients as having UARS when they met critenia, RDI < 5 characteristic findings of an elevated esophageal pressure($<-10\;cmH_2O$), frequent arousals secondary to an elevated esophageal pressure, and symptoms of daytime fatigue and sleepiness. We used polysomnographic value, which is standardized by Williams et al(1974), as normal control. Statiotical test were done with student t-tests. Results : (1) Mean age of UARS was $41.0\;{\pm}\;14.8$ years and OSA was $50.9\;{\pm}\;12.0$ years. UARS subject was significantly younger than OSA subject (p<0.05). (2) The total score of Epworth Sleepiness Scale (ESS) was UARS $9.7\;{\pm}\;6.3$ and OSAS $11.2\;{\pm}\;6.3$. There was no significant difference between two groups. (3) The mean body mass index was UARS $28.1\;{\pm}\;5.7\;kg/m^2$ and OSAS $32.9\;{\pm}\;7.0\;kg/m^2$. UARS had significantly lower meen body man index than OSAS subjects (p<0.05). (4) The polysomnographic parameters of UARS were not significantly different from those of OSA except RDI(p<0.001), $SaO_2$ (p<0.001) and slow wave sleep latency (p<0.05). (5) Compared with normal control, Total sleep time in UARS subjects was significantly shorter (p<0.001), sleep efficiency index was significantly lower (p<0.001), total awakening percentage was significantly higher (p<0.001), and sleep stage 1 (p<0.001) were significantly higher. (6) OSA patients showed poor sleep quality and distinct abnormal sleep architectures compared with normal control. Conclusions : Conclusions from the above results are as follows : (1) UARS patients were younger and had lower body mass index when umpared with OSA patients. (2) The quality of sleep and sleep architectures of the UARS and OSA patients are significantly different from those of normal control. (3) ESS scores and awakening frequencies of UARS are similar with those of OSA, suggesting that daytime dysfunction of UARS patients may be comparable to those of OSA patients. (4) The RDI and the $SaO_2$ which are important indicators in diagnosing sleep-related breathing disorders, of UARS subjects are close to normal value. (5) According to the the above results, we unclude that despite the absence of $SaO_2$ drops and the absence of an elevated number of apnea and hypopnea, subjects developed clinical complaints which were associated with laborious breathing, elevated Pes nadir, and frequently snoring. (6) Accordingly, we suggest including LIARS in the differential diagnosis list when sleep related breathing disorder is suspected clinically and overnight polysomnographic findings except snoring and frequent microarousal are within normal limits.

  • PDF

Outbreak of Hepatitis A in TaeJon in 1996 : Clinical and Epidemiologic Study in Children (1996년 대전시 서북부에서 발생한 A형 급성 간염)

  • Choi, Jin-Ook;Lee, Kyung-Yil;Lee, Dong-Joon;Han, Ji-Whan;Hwang, Sung-Soo;Lee, Kyong-Su
    • Pediatric Infection and Vaccine
    • /
    • v.4 no.1
    • /
    • pp.90-96
    • /
    • 1997
  • Purpose : Recently a shift in hepatitis A incidence from children to adults has been well noted. We experienced under 15-years old 31 patients who presented hepatitis A infection. In order to prepare for the prevention on hepatitis A outbreak in the future, we studied the clinical and epidemiologic manifestations of these patients. Methods : We enrolled patients from July to December in 1996 (6 months) and evaluated the monthly incidence, geographical distribution, age and sex, and clinical manfestations, including laboratory fadings. Results : Many cases of hepatitis A occured in the summer months, especially August (16/31 cases). Most of patients (87%) were living in the Seo-Ku area (northwest district of the city). In age distribution, there were no cases under 3 years of age, 3 cases from 4~5 years, 13 cases from 6~10 years, 15 cases from 11~15 years. Clinical profiles showed that dark urine, nausea and vomiting, anorexia, abdominal pain, fever, and fatigue were the common presenting symptoms. The initial presenting laboratory tests included total bilirubin 3.3mg/dl, alkaline phosphatase of 856units/L, and serum asparate aminotransferase and alanine aminolransferase levels of 910IU/L and 1239IU/L, respectively. No patient presented atypical clinical courses or complications. Conclusions : Hepatitis A in children shows benign clinical features. This study showed that the possibility of another outbreak of Hepatitis A in the TaeJon area or elsewhere in the near future Korea will be possible. To prevent an outbreak we will be concerned about the anti-HAV IgG prevalance rate in children and preventive modalities including vaccination against hepatitis A.

  • PDF

Open Clinical Trial of Morning Light Therapy in Sleep Disturbance of Alcohol Dependent Patients (알코올의존 환자에서의 수면장애에 대한 아침 광치료의 임상시도)

  • Ko, Young-Hoon;Joe, Sook-Haeng;Jeon, Seung-Kyu;Kim, Byoung-Kyu;Kwon, Sung-Min
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.11 no.2
    • /
    • pp.196-204
    • /
    • 2003
  • Objectives: It is known that sedative hypnotics would make cross tolerance with alcohol and deteriorate quality of sleep in alcoholics. Light therapy is effective non-pharmacological intervention for sleep disturbance in circadian phase disorders, jet-lag, shift-work and age-related sleep disorders. Authors would investigate the effects of morning light therapy on sleep of patients with alcohol dependence during recovery state without withdrawal symptoms. Methods: 13 patients with alcohol dependence who have not any alcohol withdrawal symptom were recruited. Light therapy during 1 hour in the morning had been administered by 2500 Lux light box through serial 3 days. Sleep state of subjects were assessed by sleep log and the subjective satisfaction at sleep was by 100 mm visual analogue scale. Sleepiness, depressive mood, anxiety were evaluated by 100mm visual analogue scale at 8 AM, 2 PM and 8 PM. For assessment of performance ability that would be associated with sleepiness and vigilance, trail making test A, B and digit symbol substitution test were performed by two times on base line and 4th day. Univariate repeated-measures ANOVAs were performed for each measures except performance tests which were analysed by paired t-test. Results: Sleep latency and sleep efficiency were significantly improved with light therapy and satisfaction at sleep was. There was no significant difference in sleepiness at 2 PM with light therapy but sleepiness at 8 AM significantly decreased and at 8 PM increased. The time to complete Trail making test and digit symbol substitution test were significantly shortened at 4th day compared with baseline. Fatigue at 8 AM were not significantly changed with light therapy but at 2 PM and 8 PM significantly decreased. Depressive mood and anxiety were not significantly changed with light therapy. Conclusion: Although this study had some limitations, it showed that light therapy would be effective modality on sleep disturbance of patients with alcohol dependence who have recovered from alcohol withdrawal symptoms. It is proposed that short term light therapy could be used clinically for alcoholics with insomnia. In the future, long term controlled studies using more objective tools for sleep are required to further investigate the effect of light therapy in alcoholics.

  • PDF