• Title/Summary/Keyword: Fatigue sensitivity

Search Result 164, Processing Time 0.023 seconds

The Effect of Loading Waveform on the High Temperature Fatigue Crack Propagation in P92 and STS 316L Steel (P92와 STS 316L강의 고온 피로 균열 성장에 미치는 하중 파형의 영향)

  • 김수영;임병수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.4
    • /
    • pp.136-140
    • /
    • 2002
  • High temperature fatigue crack growth behavior of P92 and STS 316L steel were investigated under four load conditions using CT type specimens. Loading and unloading times for the low wave forms were combinations of 1 sec. and 50 sec., which were two symmetric wave forms and two unsymmetric wave forms. Their behaviors are characterized using ΔK parameter. In STS 316L, Crack growth rate generally increases as frequency decreases. However, sensitivity of the loading rate to crack growth rate was fecund to be far greater than that of the unloading time. It is because as loading time increases, creep occurs at crack tip causing the crack growth rate to increase. However creep does not occur at the crack tip even if the unloading time is increased. In P92 steel, crack growth rate showed same behavior as in STS 316L. But the increase in loading or unloading time made almost no difference in crack growth rate, suggesting that no significant creep occurs in P92 steel even though loading time increases. After conducting high temperature tensile tests and comparing high temperature fatigue crack growth rates under various wave forms, it was proved that P92 steel has not only good high temperature properties but also improved, better high temperature fatigue properties than STS 316L.

Structural Safety Analysis on Bicycle Suspension Seat Post (자전거 서스펜션 안장봉에 대한 구조 안정성 해석)

  • Han, Moon-Sik;Cho, Jae-Ung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.4
    • /
    • pp.72-81
    • /
    • 2012
  • This study investigates structural, fatigue and modal analyses at bicycle suspension seat post. When weight is applied to the saddle, models 1 and 2 have the weakest strength at the part connected with saddle. And model 2 is greater total deformation and equivalent stress than model 1. Among the cases of nonuniform fatigue loads at models 1 and 2, 'SAE bracket history' with the severest change of load becomes most unstable but 'Sample history' becomes most stable. In case of 'Sample history' with the average stress of 0 to $-10^4MPa$ and the amplitude stress of 0 to $10^4MPa$, the possibility of maximum damage becomes 4%. This stress state can be shown with 5 to 7times more than the damage possibility of 'SAE bracket history' or 'SAE transmission'. Model 1 has better impulse relaxation and passenger sensitivity than model 2. The structural result of this study can be effectively utilized with the design of bicycle suspension seat post by investigating prevention and durability against its damage.

Fatigue Crack Propagation Analysis by P-version of Finite Element Method (P-Version 유한요소법에 의한 피로 균열 해석)

  • 우광성;이채규
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1992.04a
    • /
    • pp.30-35
    • /
    • 1992
  • Since many design problems in the railroad, aerospace and machine structures involve considerations of the effect of cyclic loading, manufacturing and quality control processes must fully account for fatigue of critical components. Due to the sensitivity of the Paris law, it is very important to calculate the ΔK numerically to minimize the error of predicted fatigue life in cycles. It is shown that the p-version of FEM based on LEFM analysis is far better suited for computing the stress intensity factors than the conventional h-version. To demonstrate the proficiency of the proposed scheme, the welded T-joint with crack problem of box car body bolster assembly and a crack problem emanating Iron a circular hole in finite strip have been solved.

  • PDF

Complex Leakage Probability Evaluation of Nuclear Pipes by Fatigue and Stress Corrosion Cracking (피로 및 응력부식균열에 의한 원전 배관의 복합누설확률 평가)

  • Kim, Seung Hyun;Goni, Nasimul;Chang, Yoon-Suk;Jang, Changheui
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.11 no.2
    • /
    • pp.25-30
    • /
    • 2015
  • In the present study, complex leakage probabilities of nuclear pipes due to fatigue and stress corrosion cracking are evaluated by using the PINTIN(Piping INTegrity INner flaws) that is developed based on the existing PRAISE(Piping Reliability Analysis Including Seismic Events) program. With regard to the aging and crack instability, small leak and big leak probabilities are calculated for several pipes in a reactor coolant system of domestic nuclear plant. Moreover, sensitivity analysis is also performed to find out the effect of parameters for the leakage of pipes, which shows the coolant temperature is the most influencing parameter.

Reliability of articulated tower joint against random base shear

  • Islam, Nazrul;Ahmad, Suhail
    • Structural Engineering and Mechanics
    • /
    • v.27 no.1
    • /
    • pp.33-48
    • /
    • 2007
  • An Articulated tower is one of the compliant offshore structures connected to the sea-bed through a universal joint which is the most vulnerable location of the tower that sustains the randomly fluctuating shear stresses. The time history response of the bottom hinge shear is obtained and presented in the spectral form. The fatigue and fracture reliability assessment of the tower joint against randomly varying shear stresses have been carried out. Non-linear limit state functions are derived in terms of important random variables using S-N curve and fracture mechanics approaches. Advanced First Order Reliability Method is used for reliability assessment. Sensitivity analysis shows the influence of various variables on the hinge safety. Fatigue life estimation has been made using probabilistic approach.

Clinical Usefulness of Fatigue Severity Scale for Patients with Fatigue, and Anxiety or Depression (피로와 우울.불안증 환자에서 Fatigue Severity Scale의 임상적 유용성)

  • Chung, Koo-In;Song, Chan-Hee
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.9 no.2
    • /
    • pp.164-173
    • /
    • 2001
  • Objectives : Fatigue is a common symptom in primary medical care and has nonspecific and highly subjective features. So it has been difficult to define and measure fatigue, especially those present without any organic diseases. This study was conducted to evaluate the validity of the Fatigue severity scale(FSS) in patients with persistent fatigue who were free of any organic diseases or psychiatric disorders of depression or anxiety. Methods : Subjects consisted of 45 controls, 44 fatigued patients and 43 psychiatric patients with depression or anxiety. They all completed the fatigue severity, modified Bepsi stress, and Hospital anxiety and depression scales. Chalder fatigue scale was administrated randomly in 30 of them. Data were analyzed for reliability and validity of the FSS. Results: Cronbach's a coeffient of FSS was 0.929, and the Pearson correlation coefficient for test-retest was 0.916(p<0.01). ANCOVA for discriminant validity revealed that there were significant differences in mean FSS values among the three groups. The fatigue group had significantly higher FSS value than the other two groups. The psychiatric group also had significantly higher FSS value than the control group. The Pearson correlation coefficient for convergent validity by comparing FSS with Chalder fatigue scale was 0.782(p<0.01). Using FSS index 3.22 as the cut-off point, sensitivity was 84.1% and specificity was 85.7% for the fatigue and control groups, respectively. Conclusion : Results suggested the clinical application of the FSS to be a useful measurement for distinguishing fatigue between patients with physiologic fatigue and psychiatric patients with depression or anxiety.

  • PDF

Reliability and responsiveness of Equivital Lifemonitor and photoplethysmography based wristwatch for the assessment of physiological parameters during a simulated fatigue task

  • Anwer, Shahnawaz;Li, Heng;Umer, Waleed;Antwi-Afari, Maxwell Fordjour;Wong, Arnold YL
    • International conference on construction engineering and project management
    • /
    • 2020.12a
    • /
    • pp.257-264
    • /
    • 2020
  • Objective: To investigate test-retest reliability and responsiveness of Equivital Lifemonitor and photoplethysmography based wristwatch tools in assessing physiological parameters during a simulated fatigue task. Methods: Ten university students (Mean age, 30.6 ± 1.7 years) participated in this pilot study. Participants were asked to perform a 30-minute of a simulated fatigue task in an experimental setup in a lab. The physiological parameters (e.g., heart rate, heart rate variability, respiratory rate, electrodermal activity, and skin temperature) were measured at baseline and immediately after the fatigue task. An intraclass correlation coefficient (ICC2,1) was used to evaluate the test-retest reliability of each tool in assessing physiological measures. In addition, the responsiveness of each tool to measure changes from baseline to posttest was calculated using a standardized response mean. Results: The Equivital Lifemonitor has shown good to excellent test-retest reliability for the assessment of heart rate (ICC, 0.97), heart rate variability (ICC, 0.86), respiratory rate (ICC, 0.77), and local skin temperature (ICC, 0.76). However, photoplethysmography based wristwatch showed moderate to good test-retest reliability for the assessment of heart rate (ICC, 0.71), heart rate variability (ICC, 0.73), electrodermal activity (ICC, 0.80), and skin temperature (ICC, 0.72). A large standardized response mean (>0.8) indicates that both tools can capture the changes in heart rate, heart rate variability, respiratory rate, skin temperature, and electrodermal activity after a 30-minute of fatigue task. Conclusions: The Equivital Lifemonitor and photoplethysmography based wristwatch devices are reliable in measuring physiological parameters after the fatigue task. Additionally, both devices can capture the fatigue response after a simulated construction task. Future field studies with a larger sample should investigate the sensitivity and validity of these tools in measuring physiological parameters for fatigue assessment at construction sites.

  • PDF

Sensitivity and Uncertainty Analysis of Fatigue Life of Offshore Structures (해양구조물의 피로수명 해석의 불확실성과 민감도)

  • 김도영
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.31 no.3
    • /
    • pp.77-80
    • /
    • 1994
  • 본 고에서는 해양구조물의 피로수명 해석의 불확실성의 요인들을 살펴보고, 간단한 모델을 사용 하여 각 요인들이 피로수명 해석에 미치는 영향을 살펴보고자 한다. 피로수명해석에는 일반적으 로 SN곡선을 이용하는 방법과 파괴역학을 이용하는 방법이 사용되고 있지만 여기서는 SN곡선을 이용하는 방법에 관해서만 논하기로 한다.

  • PDF

A Study on the Corrosion Susceptibility and Corrosion Fatigue Characteristics on the Material of Turbine Blade (Turbine Blade재료의 부식민감성과 부식피로특성에 관한 연구)

  • Jo, Seon-Yeong;Kim, Cheol-Han;Ryu, Seung-U;Kim, Hyo-Jin;Bae, Dong-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.3 s.174
    • /
    • pp.603-612
    • /
    • 2000
  • Corrosion characteristics on the 12Cr alloy steel of turbine blade was electro-chemically investigated in 3.5wt% NaCI and 12.7wt% Na2S04 solution, respectively. Electro-chemical polarization test, Huey test and Oxalic acid etching test were previously conducted to estimate corrosion susceptibility of the material. And, using the horizontal corrosion fatigue tester, corrosion fatigue characteristics of 12Cr alloy steel in distilled water, 3.5wt% NaCI solution, and 12.7wt%(1M) Na2S04 solution were also fracture-mechanically estimated and compared their results. Parameter considered was room temperature, 60'C and 90'C. Corrosion fatigue crack length was measured by DC potential difference method.Obtained results are as follows,1) 12Cr alloy steel showed high corrosion rate in 3.5wt% NaCI solution and Na2S04 solution at high tempratue.2) Intergranular corrosion sensitivity of 12 Cr alloy was smaller than austenitic stainless steel.3) Corrosion fatigue crack growth rate in 3.5wt% NaCI and 12.7wt%(IM) Na2S04 solution is entirely higher than in the distilled water, and also increased with the temperature increase.