• Title/Summary/Keyword: Fatigue limits

Search Result 83, Processing Time 0.023 seconds

Minimum Design Thickness of Prestressed Concrete Deck Slabs for Composite Two-Girder Bridges (강합성 2거더교 프리스트레스트 바닥판의 설계 최소두께)

  • Hwang, Hoon Hee;Joh, Changbin;Kwark, Jong Won;Lee, Yong Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.1A
    • /
    • pp.183-190
    • /
    • 2006
  • Minimizing the self weight of long-span deck slabs is one of the key factors for the practical and economic design of a composite two-girder bridge. In this paper, the minimum design thickness and rebar details of prestressed concrete deck slabs for composite two-girder bridges with girder span length from 4 m to 12 m are studied based on the safety and serviceability. The bridge deck slab with minimum thickness is designed as a one-way slab considering orthotropic behavior. Then fatigue safety of the deck slab is examined. Serviceability requirements for the deck slab such as deflection and crack width limits are also examined. The result shows that rebars with diameter less than 16 mm is recommended for the improved fatigue behavior, and, for the deck slab with span length longer than 8 m, the deflection limit governs the minimum design thickness. The result also shows that, for the deck slab with span length longer than 4 m, the distribution rebar requirement in the current Korea Highway Bridge Design Code is not sufficient to maintain the structural continuity in bridge axis as expected from the deck slab with span length shorter than 3 m.

Effect of Ganjeonggyeok Acupuncture and Saengkankunbi-tang Treatment in the Changes of LFT and Lipid-obesity Index Values (간정격 시술 및 생간건비탕 투여가 간기능 및 비만도 변화에 미치는 영향)

  • Lee, Seong-No;Kim, Sang-Joo;Lee, Jin-Seok;Kim, Eun-Geol;Jang, Suk-Geun
    • Journal of Acupuncture Research
    • /
    • v.25 no.6
    • /
    • pp.47-54
    • /
    • 2008
  • Objectives : This study was aimed to figure out how effectively acupuncture treatment and herb-medicine work on patients with elevation of LFT value and lipid-obesity index. Methods : The subject were 23 patients visited to Dept. of Acupuncture and Moxibustion, Kwangdong Oriental Medicine Hospital, who complained chronic fatigue and wandering pain from Oct. 2007. to Oct. 2008. Before treatments, they were tested for LFT, total cholesterol, triglyceride, body fat ratio and obesity index. They were treated with Ganjeonggyeok acupuncture weekly for 1 month. During acupuncture treatments, we applied Sangkankunbi-tang to all patients twice a day. After 1 month, they were retested for LFT, total cholesterol, triglyceride, body fat ratio and obesity index. Results : 1. After treatments, we could get the result of dropping means of AST, ALT and $\gamma$-GTP value. Statistical significance of ALT and $\gamma$-GTP were recognized before and after treatments, but AST was not recognized. 2. After treatments, we also could get the result of dropping means of total cholesterol, triglyceride, body fat ratio and obesity index. Statistical significance of all values were recognized before and after treatments. 3. Among 23 patients, 10 cases were reported that they were not within normal limits at least one in AST, ALT and $\gamma$-GTP. After treatments of those patients, we could get the result of dropping means of AST, ALT and $\gamma$-GTP value. Statistical significance of all values were recognized before and after treatments. 4. Among 23 patients, 19 cases were reported that they were not within normal limits at least one in total cholesterol, triglyceride, body fat ratio and obesity index. After treatments of those patients, we could get the result of dropping means of total cholesterol, triglyceride, body fat ratio and obesity index. Statistical significance of all values were recognized before and after treatments. Conclusions : Though further study is necessary, our finding suggest that the conduction of Ganjeonggyeok acupuncture and Sangkankunbi-tang treatments have helped to decrease the figures of LFT and lipid-obesity index in patients.

  • PDF

Study on the Exposure Levels of Organic Solvents and Subjective Symptoms of Dry-cleaning Workers (드라이클리닝 근로자들의 유기용제 폭로와 자각증상)

  • Kim, Soo-Young;Kim, Jeong-Yun;Lee, Yeon-Kyeng;Lee, Sok-Goo;Lee, Young-Soo;Cho, Young-Chae;Lee, Tae-Young;Lee, Dong-Bae
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.4 s.63
    • /
    • pp.628-643
    • /
    • 1998
  • To investigate the exposure levels of organic solvents and subjective symptoms of dry-cleaning workers, 77 male and 52 female dry-cleaning workers who had been worked in a small city of Chungnam province, and a large city, Taejon were selected for the study group. Air concentrations of organic solvents in the working environment were analyzed, and subjective symptoms of dry-cleaning workers were surveyed, from July to August 1996. The results obtained were as follows : 1. The concentrations of organic solvents in the working environment were within permissible TLV-TWA limits. 2. For the 13 symptom clusters, the most frequently complained symptom clusters were fatigue as 71.3%, and followed by depression and urinary disturbances as 53.5% and 51.9%. Other symptom clusters complained were below 50%. 3. Positive response rates of subjective symptoms were significantly higher in worker groups such as lived in a large city, female, higher education level, more frequently alcohol drinking, higher concentration of organic solvent in working environment, work in alone. 4. Workers who had used solvent B showed 2.3 point higher scores of subjective symptoms than those of solvent A. Of the subjective symptoms scores, amnesia and nervousness were higher in solvent B user group than solvent B user group. 5. As a result of factor analysis, 3 factors such as depression, urinary disturbance and neurologic disturbance were selected. 6. As a result of the logistic regression analysis, sex, the number of fellow workers, working time, region, job tenure, smoking, alcohol drinking, ventilating system, concentration of organic solvent in working environment and place of residence were selected for the related variables. For the conclusion, even though the concentrations of organic solvents in the working environments of dry-cleaning workers were within permissible limit of TLV-TWA, many dry-cleaning workers complained symptoms, such as fatigue, depression, urinary disturbances and so on. And the factors affecting to the symptoms of dry-cleaning workers were the number of fellow workers, work hours, region, job tenure, smoking and alcohol drinking.

  • PDF

Review on Clinical Trials of Chemotherapy Induced Toxicity with Acupuncture in PubMed Database (PubMed 검색을 통한 항암화학요법 부작용 관련 침 임상시험 현황 고찰)

  • Kim, Jong Yoon;Kim, Jin Youp;Kim, Nam Sik;Kim, So Jung;Oyungerel, Munkhgerel;Kim, Yong Suk;Choi, Do Young;Nam, Sang Soo
    • Journal of Acupuncture Research
    • /
    • v.30 no.2
    • /
    • pp.43-53
    • /
    • 2013
  • Objectives : The purpose of this study is to review of Clinical trials related to the treatment of chemotherapy induced-toxicity by acupuncture therapy. Methods : We searched PubMed by using word of "chemotherapy induced, acupuncture" (Limits : Full text available, 10 years, Clinical trials, Humans, English). We analyzed 15 research paper and examined published journals, years, countries, topic, study design, their results, interventions, participants and instruments of assessment. Results : Eleven journals with fifteen papers were searched. These papers were published in USA, Germany, etc. On the topic of these clinical trials, seven of them were about nausea(vomiting), two about peripheral neuropathy, two about hot flash, two about arthralgia and one about neutropenia, one about fatigue. Six of these studies were single blinded, randomized controlled trial. Twelve studies reported significant effect. The median for number of final participants was 35.5 persons. Assessment for outcomes were versatile questionnaire, nerve conduction studies, WBC, ANC, G-CSF examination, etc. Conclusions : Their median for impact factor was 3.650 and average modified Jadad score of six RCTs was 4.33. In order to provide appropriate evidence regarding the effectiveness of acupuncture in treatment for chemotherapy-induced toxicity, more rigorous and well-designed studies are necessary.

Fracture resistance of implant- supported monolithic crowns cemented to zirconia hybrid-abutments: zirconia-based crowns vs. lithium disilicate crowns

  • Elshiyab, Shareen H;Nawafleh, Noor;Ochsner, Andreas;George, Roy
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.1
    • /
    • pp.65-72
    • /
    • 2018
  • PURPOSE. The aim of this in vitro study was to investigate the fracture resistance under chewing simulation of implant-supported posterior restorations (crowns cemented to hybrid-abutments) made of different all-ceramic materials. MATERIALS AND METHODS. Monolithic zirconia (MZr) and monolithic lithium disilicate (MLD) crowns for mandibular first molar were fabricated using computer-aided design/computer-aided manufacturing technology and then cemented to zirconia hybrid-abutments (Ti-based). Each group was divided into two subgroups (n=10): (A) control group, crowns were subjected to single load to fracture; (B) test group, crowns underwent chewing simulation using multiple loads for 1.2 million cycles at 1.2 Hz with simultaneous thermocycling between $5^{\circ}C$ and $55^{\circ}C$. Data was statistically analyzed with one-way ANOVA and a Post-Hoc test. RESULTS. All tested crowns survived chewing simulation resulting in 100% survival rate. However, wear facets were observed on all the crowns at the occlusal contact point. Fracture load of monolithic lithium disilicate crowns was statistically significantly lower than that of monolithic zirconia crowns. Also, fracture load was significantly reduced in both of the all-ceramic materials after exposure to chewing simulation and thermocycling. Crowns of all test groups exhibited cohesive fracture within the monolithic crown structure only, and no abutment fractures or screw loosening were observed. CONCLUSION. When supported by implants, monolithic zirconia restorations cemented to hybrid abutments withstand masticatory forces. Also, fatigue loading accompanied by simultaneous thermocycling significantly reduces the strength of both of the all-ceramic materials. Moreover, further research is needed to define potentials, limits, and long-term serviceability of the materials and hybrid abutments.

Study of heavy fuel oil fly ash for use in concrete blocks and asphalt concrete mixes

  • Al-Osta, Mohammed A.;Baig, Mirza G.;Al-Malack, Muhammad H.;Al-Amoudi, Omar S. Baghabra
    • Advances in concrete construction
    • /
    • v.4 no.2
    • /
    • pp.123-143
    • /
    • 2016
  • Use of heavy fuel fly ash (HFFA) (diesel and cracked fuel) for power generation in Saudi Arabia has generated and accumulated large quantities of HFFA as a byproduct. In this research, HFFA is studied with the emphasis on the utilization of this waste material in concrete blocks and asphalt concrete mixes. Two types of mixes, one with low and other with high cement content, were studied for concrete blocks. Different mixes having varying percentages of HFFA (0% to 25%), as cement/sand replacement or as an additive, were studied. The performance of concrete blocks is evaluated in terms of compressive strength, water absorption, durability and environmental concerns. The results showed that blocks cannot be cast if more than 15% HFFA is used; also there is a marginal reduction in the strength of all the mixes before and after being exposed to the sulfate solution for a period of ten months. HFFA is studied in asphalt concrete mixes in two ways, as an asphalt modifier (3&5%) and as a filler (50%) replacement, the results showed an improvement in stiffness and fatigue life of mixes. However, the stability and indirect tensile strength loss were found to be high as compared to the control mix due to moisture damage, indicating a need of using antistripping agents. On environmental concerns, it was found that most of the concerned elements are within acceptable limits also it is observed that lower concentration of barium is leached out with the higher HFFA concentrations, which indicates that HFFA may work as an adsorbent for this leaching element.

Investigation of the Maintenance Criteria for the Rail Surface Defects in High-Speed Railways (고속철도 레일 표면 결함 관리기준에 관한 연구)

  • Yang, Sin-Chu;Jang, Seung-Yup
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.6
    • /
    • pp.535-544
    • /
    • 2011
  • The rail surface defects can cause the high impact load on the track and lead to the progress of the rail fatigue damage and the rail break. In case of the rail break, there is a great deal of risk for derailment, and thus the maintenance criteria for the rail surface defects are of great importance. In this study, using the dynamic train-track interaction analysis program, the impact wheel loads and rail bending stresses according to the depths of the surface defects have been calculated with the input data of the rail surface irregularities measured at 43 spots with surface defects in the ballasted track of high-speed railway. Considering the irregularity of track geometry, the allowable limits of wheel load and rail bending stress have been set, and the maintenance criteria for the rail surface defects was suggested by analyzing the relationship of the maximum values of wheel load and rail bending stress versus depth and width of rail surface defect. The analysis results suggest that the allowable depth of the surface defect is determined approximately 0.2mm from the limit of the impact wheel load.

Effect of Nitrogen, Titanium, and Yttrium Doping on High-K Materials as Charge Storage Layer

  • Cui, Ziyang;Xin, Dongxu;Park, Jinsu;Kim, Jaemin;Agrawal, Khushabu;Cho, Eun-Chel;Yi, Junsin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.6
    • /
    • pp.445-449
    • /
    • 2020
  • Non-volatile memory is approaching its fundamental limits with the Si3N4 storage layer, necessitating the use of alternative materials to achieve a higher programming/erasing speed, larger storage window, and better data retention at lower operating voltage. This limitation has restricted the development of the charge-trap memory, but can be addressed by using high-k dielectrics. The paper reviews the doping of nitrogen, titanium, and yttrium on high-k dielectrics as a storage layer by comparing MONOS devices with different storage layers. The results show that nitrogen doping increases the storage window of the Gd2O3 storage layer and improves its charge retention. Titanium doping can increase the charge capture rate of HfO2 storage layer. Yttrium doping increases the storage window of the BaTiO3 storage layer and improves its fatigue characteristics. Parameters such as the dielectric constant, leakage current, and speed of the memory device can be controlled by maintaining a suitable amount of external impurities in the device.

Influence of Implant Fixture-Abutment Connection and Abutment Design on Mechanical Strength (임플란트 고정체-지대주 연결부 및 지대주 디자인이 기계적 강도에 미치는 영향)

  • Chun, Mi-Hyun;Jeong, Chang-Mo;Jeon, Young-Chan;Eom, Tae-Gwan;Yoon, Ji-Hoon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.3
    • /
    • pp.269-281
    • /
    • 2008
  • Fatigue or overload can result in mechanical problems of implant components. The mechanical strength in the implant system is dependent on several factors, such as screw and fixture diameters, material, and design of the fixture-abutment connection and abutment. In these factors, the last rules the strength and stability of the fixture-abutment assembly. There have been some previous reports on the mechanical strength of the fixture-abutment assembly with the compressive bending test or short-term cyclic loading test. However, it is restrictive to predict the long-term stability of the implant system with them. The purpose of this study was to evaluate the influence of the design of the fixture-abutment connection and abutment on the mechanical strength and failure mode by conducting the endurance limit test as well as the compressive bending strength test. Tests were performed according to a specified test(ISO/FDIS 14801) in 4 fixture-abutment assemblies of the Osstem implant system: an external butt joint with Cemented abutment (group BJT), an external butt joint with Safe abutment (group BJS), an internal conical joint with Solid abutment (group CJO), and an internal conical joint with ComOcta abutment (group CJT). The following conclusions were drawn within the limitation of this study. Compressive bending strengths were decreased in order of group BJS(1392.0N), group CJO(1261.8N), group BJT(1153.2N), and group CJT(1110.2N). There were no significant differences in compressive bending strengths between group BJT and group CJT(P>.05). Endurance limits were decreased in order of group CJO(600N), group CJT(453N), group BJS(360N), and group BJT(300N). 3. Compressive bending strengths were influenced by the connection and abutment design of the implant system, however endurance limits were affected more considerably by the connection design.

A Study of Upper Airway Resistance Syndrome : Clinical and Polysomnographic Characteristics (상기도저항 증후군에 대한 연구 : 임상 및 수면다원검사 특징)

  • Yang, Chang-Kook;Clerk, Alex
    • Sleep Medicine and Psychophysiology
    • /
    • v.3 no.2
    • /
    • pp.32-42
    • /
    • 1996
  • Objectives : Upper airway resistance syndrome(UARS) is a sleep-related breathing disorder characterized by abnormal negative intrathoracic pressure during sleep. Abnormally increased negative intrathoracic pressure results in microarousal and sleep fragmentation which underlay UARS-associated complaints of daytime fatigue and sleepiness. Although daytime dysfunction in patients with UARS is comparable to that of sleep apnea syndrome, UARS has been relatively unnoticed in clinical setting. That is why UARS is apt to be excluded in diagnosing of sleep-related breathing disorders since its respiratory disturbance index and arterial oxygen saturation are within normal limits. The current study presents a summary of clinical and polysomnographic characteristics found in patients with UARS. The present study aims (1) to explore characteristics of patients diagnosed with UARS, (2) to characterize the polysomnographic findings of UARS patients, and (3) to enhance the understanding of UARS through those clinical and laboratory characteristics. Methods : This was a retrospective study of 20 UARS patients (male 15, female 5) and 30 obstructive sleep apnea (OSA) patients (male 21, female 9) at the Stanford Sleep Disorders Clinic. We diagnosed patients as having UARS when they met critenia, RDI < 5 characteristic findings of an elevated esophageal pressure($<-10\;cmH_2O$), frequent arousals secondary to an elevated esophageal pressure, and symptoms of daytime fatigue and sleepiness. We used polysomnographic value, which is standardized by Williams et al(1974), as normal control. Statiotical test were done with student t-tests. Results : (1) Mean age of UARS was $41.0\;{\pm}\;14.8$ years and OSA was $50.9\;{\pm}\;12.0$ years. UARS subject was significantly younger than OSA subject (p<0.05). (2) The total score of Epworth Sleepiness Scale (ESS) was UARS $9.7\;{\pm}\;6.3$ and OSAS $11.2\;{\pm}\;6.3$. There was no significant difference between two groups. (3) The mean body mass index was UARS $28.1\;{\pm}\;5.7\;kg/m^2$ and OSAS $32.9\;{\pm}\;7.0\;kg/m^2$. UARS had significantly lower meen body man index than OSAS subjects (p<0.05). (4) The polysomnographic parameters of UARS were not significantly different from those of OSA except RDI(p<0.001), $SaO_2$ (p<0.001) and slow wave sleep latency (p<0.05). (5) Compared with normal control, Total sleep time in UARS subjects was significantly shorter (p<0.001), sleep efficiency index was significantly lower (p<0.001), total awakening percentage was significantly higher (p<0.001), and sleep stage 1 (p<0.001) were significantly higher. (6) OSA patients showed poor sleep quality and distinct abnormal sleep architectures compared with normal control. Conclusions : Conclusions from the above results are as follows : (1) UARS patients were younger and had lower body mass index when umpared with OSA patients. (2) The quality of sleep and sleep architectures of the UARS and OSA patients are significantly different from those of normal control. (3) ESS scores and awakening frequencies of UARS are similar with those of OSA, suggesting that daytime dysfunction of UARS patients may be comparable to those of OSA patients. (4) The RDI and the $SaO_2$ which are important indicators in diagnosing sleep-related breathing disorders, of UARS subjects are close to normal value. (5) According to the the above results, we unclude that despite the absence of $SaO_2$ drops and the absence of an elevated number of apnea and hypopnea, subjects developed clinical complaints which were associated with laborious breathing, elevated Pes nadir, and frequently snoring. (6) Accordingly, we suggest including LIARS in the differential diagnosis list when sleep related breathing disorder is suspected clinically and overnight polysomnographic findings except snoring and frequent microarousal are within normal limits.

  • PDF