• 제목/요약/키워드: Fatigue Crack Growth Test

검색결과 305건 처리시간 0.021초

1Cr-0.5Mo강 용접부 균열의 고온파괴거동 연구 (A Study on Elevated Temperature Fracture Behavior of Cracks in 1Cr-0.5Mo Steel Weld)

  • 신규인;윤기봉;최현창;박재학;이해무
    • 한국안전학회지
    • /
    • 제12권2호
    • /
    • pp.45-56
    • /
    • 1997
  • Fracture behavior of ex-serviced 1Cr-0.5Mo steel was measured at room($24^{\circ}C$) and elevated($538^{\circ}C$) temperature and compared with that measured with virgin 1Cr-0.5Mo steel. Compact C(T) specimens were machined from the base and welded test materials. In case of the C(T) specimens of the weld, fatigue precrack was introduced along the fusion line so that following crack growth should occurs along the region of heat affected zone. It was observed that the J-R curve of the serviced material was significantly lower than that of the virgin material at room temperature. Brittle fracture was observed in the serviced material. On the other hand, at elevated temperature no noticeable difference was found between the J-R curves of the virgin and the serviced material. The measured J-R curves were also compared with those of the 1.25Cr-0.5Mo steel obtained from the other literatures. Optical microscopy and SEM examination of the serviced material reveal the carbide in/along the grain boundary which shows material degradation due to long-term usage. An example of application of the measured J-R curves is shown.

  • PDF

취성재료의 장기 강도시험 중 미소파괴음 신호 분석 (Analysis of Acoustic Emission Signals during Long-Term Strength Tests of Brittle Materials)

  • 천대성;정용복
    • 터널과지하공간
    • /
    • 제27권3호
    • /
    • pp.121-131
    • /
    • 2017
  • 본 연구에서는 암석과 콘크리트의 정적 및 동적 장기강도시험을 통해 이들 재료의 시간 의존적 거동에 대해 연구했으며, 특히 장기강도시험 중 발생한 미소파괴음 신호를 분석하여 장기 안정성 평가에 활용하고자 하였다. 정적 장기강도시험의 경우 임계하 균열성장시험을 활용하여 Mode I과 Mode II에 대한 장기거동과 미소파괴음 발생특성을 분석하였으며, 동적 장기강도시험의 경우, 반복재하 4점 굴곡시험을 통한 장기강도의 한계와 미소파괴음 발생특성을 분석하였다. 미소파괴음 분석결과, 미소파괴음 히트 누적곡선 대 시간에 따른 곡선은 1차, 2차, 3차 구간이 있는 크립곡선의 모양과 유사한 모양을 보였다. 선형구간에 해당하는 미소파괴음 히트 누적곡선의 2차 구간의 기울기와 지연파괴시간과의 로그-로그 관계로부터 암석과 콘크리트의 정적 및 동적 장기 안정성을 평가하는 방안에 대한 가능성을 제시하였다.

피로시험시 발생하는 음향방출신호를 이용한 Type II Gas Cylinder의 손상평가 (Effect of Acoustic Emission During a Fatigue Test with Defect for Type II Gas Cylinder)

  • 지현섭;이종오;주노회;소철호;이종규
    • 한국가스학회지
    • /
    • 제16권2호
    • /
    • pp.18-24
    • /
    • 2012
  • 본 연구는 Type II 가스실린터의 20,000 회 피로시험과 파열시험시 음향방출시험을 병행하여 용기의 손상정도를 평가하고자 하였으며, 실험에 사용된 용기는 결함 크기가 $3mm{\times}3mm{\times}50mm$ (폭${\times}$깊이${\times}$길이)이고 결함 방향이 용기의 종방향 및 횡방향인 인공결함용기와 건전한 용기 등 세 종류이다. 피로시험시 발생된 음향방출신호는 종방향결함의 경우 전체 신호 중 결함에서 발생된 이벤트의 비율이 50 % 이상이며, 음향방출신호의 위치표정도 매우 정확하게 일치하였다. 또한 파열시험에서는 인공결함용기가 결함 위치에서 에상파열압력보다 낮은 압력으로 파열될거라는 예상과는 달리 인공결함용기의 파열압력은 건전한 용기와 큰 차이가 없었으며, 단지 종방향 인공결함용기의 경우 파열위치가 결함 위치와 근접하게 발생하였다. 이는 종방향 결함의 길이만큼 복합재료의 두께가 얇아지는 효과로 나타나게 되어 금속라이너의 피로반복시 결함 발생과 성장위치에 영향을 미친 것으로 판단된다.

다구찌 기법을 이용한 이종재료 경사 홀 클린칭 접합부 수평 방향 접합강도 예측 및 검증 (Prediction and Verification of Lateral Joining Strength for Tapered-Hole Clinching using the Taguchi Method)

  • 강동식;박으뜸;;강범수;송우진
    • 소성∙가공
    • /
    • 제25권1호
    • /
    • pp.36-42
    • /
    • 2016
  • Fiber metal laminates (FMLs) are well known for improved fatigue strength, better impact resistance, superior damage tolerance and slow crack growth rate compared to traditional metallic materials. However, defects and loss of strength of a composite material can occur due to the vertical load from the punch during the joining with a dissimilar material using a conventional clinching method. In the current study, tapered-hole clinching was an alternative process used to join Al 5052 and FMLs. The tapered hole was formed in the FML before the joining. For the better understanding of static and dynamic characteristics, a clinched joining followed by a tensile-shear test was numerically simulated using the finite element analysis. The design parameters were also evaluated for the geometry of the tapered hole by the Taguchi method in order to improve and compare the lateral joining strength of the clinched joint. The influence of the neck thickness and the undercut were evaluated and the contribution of each design parameter was determined. Then, actual experiments for the joining and tensile-shear test were conducted to verify the results of the numerical simulations. In conclusion, the appropriate combination of the design parameters can improve the joining strength and the cross-sections of the tapered-hole clinched joint formed in the actual experiments were in good agreement with the results of the numerical simulations.

음향방출법을 이용한 Type 1 및 Type 2 가스실린더의 정량적 평가기준에 대한 연구 (Study of Quantitative Assessment Standard for Type 1 and Type 2 Gas Cylinders Using Acoustic Emission Testing)

  • 김동현;이상범;김경훈;윤동진;배동명
    • 비파괴검사학회지
    • /
    • 제34권2호
    • /
    • pp.176-183
    • /
    • 2014
  • 음향방출법은 차량 내부에 장착된 실린더의 경우 분해없이 동작중에 실시간으로 측정이 가능하므로 다른 비파괴평가 방법보다 많은 장점을 가지고 있다. 이러한 장점을 가지고 음향방출법은 미국 교통부(DOT)로부터 수압시험의 대체로 압력용기의 안정성 평가 방법으로 승인되었다. 본 논문은 압력용기 제조사로부터 UT 결함용기 및 결함이 있는 이음매 없는 압력용기인 Type 1과 Type 2에 대한 정량적인 평가기준에 대한 연구를 수행하였다. Type 1의 경우, ASTM E 1419-02를 기준으로 113L 규격의 준비된 용기로 피로반복시험을 통해 크랙의 성장부터 누설까지 경향을 파악하였다. Type 2의 경우, ASTM E 2191-02를 기준으로 119L 건전한 용기와 수압가압으로 불량용기를 용기에 slow-fill 방법으로 검증하였다. 본 연구에서 음향방출법을 이용한 Type 1과 Type 2의 시험은 불량용기와 건전한 용기를 효과적으로 구분할 수 있었다.