• 제목/요약/키워드: Fast magnetic resonance imaging (MRI)

검색결과 84건 처리시간 0.031초

Carotid Intraplaque Hemorrhage Imaging: Diagnostic Value of High Signal Intensity Time-of-Flight MR Angiography Compared with Magnetization-Prepared Rapid Acquisition with Gradient-Echo Sequencing

  • Ahn, Ji-eun;Kwak, Hyo Sung;Chung, Gyung Ho;Hwang, Seung Bae
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권2호
    • /
    • pp.94-101
    • /
    • 2018
  • Purpose: To determine the value of the appearance of the high signal intensity halo sign for detecting carotid intraplaque hemorrhage (IPH) on maximum intensity projection (MIP) of time-of-flight (TOF) MR angiography (MRA), based on high signal intensity on magnetization-prepared rapid acquisition with gradient-echo (MPRAGE) sequencing. Materials and Methods: A total of 78 carotid arteries in 65 patients with magnetization-prepared rapid acquisition gradient-echo (MPRAGE) positive on carotid plaque MR imaging were included in this study. High-resolution MR imaging was performed on a 3.0-T scanner prior to carotid endarterectomy or carotid artery stenting. Fast spin-echo T1- and T2-weighted axial imaging, TOF, and MPRAGE sequences were obtained. Carotid plaques with high signal intensity on MPRAGE > 200% that of adjacent muscle on at least two consecutive slices were defined as showing IPH. Halo sign of high signal intensity around the carotid artery was found on MIP from TOF MRA. Continuous and categorical variables were compared among groups using the Mann-Whitney test and Fisher's exact tests. Results: Of these 78 carotid arteries, 53 appeared as a halo sign on the TOF MRA. The total IPH volume of patients with a positive halo sign was significantly higher than that of patients without a halo sign ($75.0{\pm}86.8$ vs. $16.3{\pm}18.2$, P = 0.001). The maximum IPH axial wall area in patients with a positive halo sign was significantly higher than that of patients without a halo sign ($11.3{\pm}9.9$ vs. $3.7{\pm}3.6$, P = 0.000). Conclusion: High signal intensity halo of IPH on MIP of TOF MRA is associated with total volume and maximal axial wall area of IPH.

척추 전이암에서 확산강조 자기공명 영상을 이용한 치료반응의 평가 (Evaluation of Treatment Response Using Diffusion-Weighted MAI in Metastatic Spines)

  • 이장진;신세원
    • Journal of Yeungnam Medical Science
    • /
    • 제18권1호
    • /
    • pp.30-38
    • /
    • 2001
  • 본 연구는 골 전이암에 대한 치료에 통상적으로 이용되는 방사선치료 후 치료반응을 객관적으로 평가하는 데 필요한 새로운 영상진단 방법의 적용 가능성을 확인하기 위하여 시행되었다. 척추에 혈행성 전이를 일으킨 21명의 환자를 대상으로 방사선치료 전 후에 확산 강조 자기공명 영상을 시행한 10명의 환자에서 방사선치료 전 후에 골수 조직의 신호 강도의 변화가 현저하였으므로 기존의 진단방법인 단순 X-선 촬영, 방사성 동위원소 골 주사, 전산화 단층 촬영 및 스핀 에코 자기공명 영상진단을 보완할 수 있다는 가능성을 확인하였다. 그렇지만 대상 환자의 숫자가 적고 추적기간이 짧기 때문에 이 촬영기법이 척추에 혈행성 골 정기가 의심되는 환자에서 기본적인 검사방법으로 자리잡기 위해서는 더 많은 화자를 대상으로 가능한 병리조직학적 검사를 병행하여 장기간에 걸쳐 전향적인 검토가 필요하다고 생각되었다.

  • PDF

The Human Brain and Information Science: Lessons from Popular Neuroscience

  • Sturges, Paul
    • International Journal of Knowledge Content Development & Technology
    • /
    • 제3권1호
    • /
    • pp.19-29
    • /
    • 2013
  • Insights from the recent wealth of popular books on neuroscience are offered to suggest a strengthening of theory in information science. Information theory has traditionally neglected the human dimension in favour of 'scientific' theory often derived from the Shannon-Weaver model. Neuroscientists argue in excitingly fresh ways from the evidence of case studies, non-intrusive experimentation and the measurements that can be obtained from technologies that include electroencephalography, positron emission tomography (PET), functional magnetic resonance imaging (fMRI), and magnetoencephalography (MEG). The way in which the findings of neuroscience intersect with ideas such as those of Kahneman on fast and slow thinking and Csikszentmihalyi on flow, is tentatively explored as lines of connection with information science. It is argued that the beginnings of a theoretical underpinning for current web-based information searching in relation to established information retrieval methods can be drawn from this.

The fate of necrosis-avid MR contrast material (Gadophrin-2)-enhanced area of acute reperfused myocardial infarction as determined by MR imaging with Gd-DTPA enhancement and TTC staining after four weeks in a rabbit model

  • Choe, Yeon-Hyeon;Park, Jong-Min;Weinmann, Hanns J.
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2002년도 제7차 학술대회 초록집
    • /
    • pp.114-114
    • /
    • 2002
  • Purpose: To know the fate of Gadophrin-2-enhanced areas in hearts with acute reperfused myocardial infarction. Method: The left anterior descending branches of coronary arteries were occluded for 90 min and reperfused for 60 min in 15 rabbits. Then, Gadophrin-2 (0.05 mmol/kg) was injected via ear veins. Short-axial T1-weighted spin echo images and fast cine images were obtained 24 hours after injection of Gadophrin-2. After four weeks, short-axial cine MRI was performed and T1-weighted spin echo Images were obtained 5 min and 15 min after injection of Gd-DTPA (0.2 mmol/kg). The animals were sacrificed and short-axial slices of the specimen were stained with 1.5% triphenyltetrazolium chloride (TTC) solution.

  • PDF

An Automated Way to Detect Tumor in Liver

  • Meenu Sharma. Rafat Parveen
    • International Journal of Computer Science & Network Security
    • /
    • 제23권10호
    • /
    • pp.209-213
    • /
    • 2023
  • In recent years, the image processing mechanisms are used widely in several medical areas for improving earlier detection and treatment stages, in which the time factor is very important to discover the disease in the patient as possible as fast, especially in various cancer tumors such as the liver cancer. Liver cancer has been attracting the attention of medical and sciatic communities in the latest years because of its high prevalence allied with the difficult treatment. Statistics indicate that liver cancer, throughout world, is the one that attacks the greatest number of people. Over the time, study of MR images related to cancer detection in the liver or abdominal area has been difficult. Early detection of liver cancer is very important for successful treatment. There are few methods available to detect cancerous cells. In this paper, an automatic approach that integrates the intensity-based segmentation and k-means clustering approach for detection of cancer region in MRI scan images of liver.

The Feasibility of Event-Related Functional Magnetic Resonance Imaging of Power Hand Grip Task for Studying the Motor System in Normal Volunteers; Comparison with Finger Tapping Task

  • Song, In-Chan;Chang, Kee-Hyun;Han, Moon-Hee
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.111-111
    • /
    • 2001
  • 목적: To evaluate the feasibility of the event-related functional MR study using power grip studying the hand motor system 대상 및 방법: Event-related functional MRI was performed on a 1.5T MR unit in seven norm volunteers (man=7, right-handedness=2, left-handedness=5, mean age: 25 years). A single-shot GRE-EPI sequence (TR/TE/flip angle: 1000ms/40ms/90, FOV = 240 mm matrix= 64$\times$64, slice thickness/gap = 5mm/0mm, 7 true axial slices) was used for functiona MR images. A flow-sensitive conventional gradient echo sequence (TR/TE/flip angl 50ms/4ms/60) was used for high-resolution anatomical images. To minimize the gross hea motion, neck-holders (MJ-200, USA) were used. A series of MR images were obtained in axial planes covering motor areas. To exclude motion-corrupted images, all MR images wer surveyed in a movie procedure and evaluated using the estimation of center of mass of ima signal intensities. Power grip task consisted of the powerful grip of all right fingers and hand movement ta used very fast right finger tapping at a speed of 3 per 1 second. All tasks were visual-guid by LCD projector (SHARP, Japan). Two tasks consisted of 134 phases including 7 activatio and 8 rest periods. Active stimulations were performed during 2 seconds and rest period were 15 seconds and total scan time per one task was 2 min 14 sec. Statistical maps we obtained using cross-correlation method. Reference vector was time-shifted by 4 seconds an Gaussian convolution with a FWHM of 4 seconds was applied to it. The threshold in p val for the activation sites was set to be 0.001. All mapping procedures were peformed usin homemade program an IDL (Research Systems Inc., USA) platform. We evaluated the activation patterns of the motor system of power grip compared to hand movement in t event-related functional MRI.

  • PDF

Quantitative Analysis of Cerebellar Cortical Degeneration Using MRI in Dogs

  • Seok-Min Lee;A-Rim Lee;Young-Won Lee;Ho-Jung Choi
    • 한국임상수의학회지
    • /
    • 제40권3호
    • /
    • pp.225-229
    • /
    • 2023
  • In three dogs showing cerebellar ataxia, the onset of clinical signs varied from a young age of five months to age 13 years. Qualitative magnetic resonance imaging (MRI) revealed various degrees of cerebellar atrophy, and a tentative diagnosis of cerebellar cortical degeneration was made. Quantitative analysis using the brainstem to the cerebellar cross-sectional area ratio (BS:CBM ratio) and T2-signal intensity histograms were obtained to perform an objective evaluation. These techniques have the advantage of being easy and fast to evaluate. These quantitative analyses revealed the severity of cerebellar cortical degeneration in the three dogs as mild, moderate, and severe. Dogs 2 and 3 were identified as abnormal on the relative cerebrospinal fluid (CSF) space using T2-signal intensity histograms but were normal on the BS:CBM ratio. This suggests that the T2-signal intensity histograms may have higher sensitivity than BS:CBM ratio.

3T 고속스핀에코 T2강조영상에서 지방소거 반전회복기법의 유용성 연구 - SPAIR와 STIR와의 비교 - (Comparative Study on Usefulness of SPAIR and STIR Fast SE T2-weighted 3T Magnetic Resonance Imaging)

  • 이후민;윤준;여영복
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권1호
    • /
    • pp.45-50
    • /
    • 2010
  • 본 연구는 T2고속스핀에코 3.0T 자기공명영상에서 지방조직 소거기법인 SPAIR와 STIR기법의 임상적 유용성에 관한 비교연구를 시행하였다. SPAIR와 STIR 프로토콜을 사용하여 뇌의 축방향 영상(20개), 요추의 시상단면영상(20개), 고관절의 관상단면영상(17개), 무릎관절의 축방향 영상(25개)을 획득하였다. 검사부위별로 지방억제기법의 지방소거능력과 화질을 파악하기위해 지방조직의 신호강도와 불균일성을 측정하였다. 지방조직에서 불균일치는 측정된 지방 신호의 평균치(mean)에 대한 표준편차(SD)로서 그 산출은 SD/mean으로 계산하였다. 수집된 자료는 SPSS(Statistical Package for the Social Science) WIN 13.0 프로그램을 이용하여 분석한 결과 다음과 같은 결론을 얻었다. 첫째, 뇌 검사는 SPAIR가 STIR보다 지방억제능력과 화질면에서 우수한 결과를 나타냈으며, 둘째, 요추, 고관절, 무릎관절 검사는 지방의 신호억제능력은 STIR가 우수하고, 화질면에서는 SPAIR가 우수한 결과를 나타냈다.

자기공명 혈관조영술의 고찰 및 구현 (Review and Implementation of Magnetic Resonance Angiography)

  • 이윤;류택현;주희연;김시승;김일영;이만우;오창현;안창범;이흥규
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.223-226
    • /
    • 1997
  • X-Ray Angiography has been gold standard for imaging of blood flow. However, patients have to take many risks such as catheterization procedure, iodine contrast agent and ionizing X-rays. MR Angiography has been suggested as a substitute for its non-hazard to patient. But the resolution and contrast was inferior to that of X-ray Angiography. Recently the resolution and the contrast have been much improved due to the development of fast imaging technique. Here we report some preliminary results of the MR Angiography we have implemented on 1 Tesla MRI unit.

  • PDF

Effects of NEX on SNR and Artifacts in Parallel MR Images Acquired using Reference Scan

  • Heo, Yeong-Cheol;Lee, Hae-Kag;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • 제18권4호
    • /
    • pp.422-427
    • /
    • 2013
  • The aim of this study was to investigate effects of the number of acquisitions (NEX) on signal-to-noise (SNR) and artifacts in SENSE parallel imaging of magnetic resonance imaging (MRI). 3.0T MR System, 8 Channel sensitivity encoding (SENSE) head coils were used along with an in-vivo phantom. Reference sequence of 3D fast field echo (FFE) was consisted of NEX values of 2, 4, 6, 8, 10 and 12. The T2 turbo spin echo (TSE) sequence used for exams achieved SENSE factors of 1.2, 1.5, 1.8, 2.0, 2.2, 2.5, 2.8, 3.0, 3.2, 3.5, 3.8 and 4.0. Exams were conducted five times for each SENSE factor to measure signal intensity of the object, the posterior phase-encode direction and frequency direction. And SNR was calculated using mean values. SENSE artifacts were identified as background signal intensity in the phase-encoded direction using MRIcro. It was found that SNR increased but SENSE artifacts reduced with NEX of 4, 8 and 12 when the NEX increased in reference scan. It is therefore concluded that image quality can be improved with NEX of 4, 8 and 12 for reference scanning.