• 제목/요약/키워드: Fast magnetic resonance imaging

검색결과 142건 처리시간 0.023초

MR Imaging and Histological Findings of Experimental Cerebral Fat Embolism in Cats

  • Park Byung-Rae;Ko Seong-Jin;Kim Hwa-Gon
    • 대한의생명과학회지
    • /
    • 제10권3호
    • /
    • pp.285-291
    • /
    • 2004
  • To determine the magnetic resonance (MR) imaging findings and natural history of cerebral fat embolism in a cat model, and to correlate the MR imaging and histologic fmdings. Intemel carotid artery of 11 cats was injected with 0.1 ml of triolein. T2-weighted, T1-weighted and Gd-enhanced T1-weighted images were obtained serially for 2 hours, 1 days, 4 days, 1 week, 2 weeks and 3 weeks after embolization. Any abnormal signal intensity was evaluated. After MR imaging at 3 weeks, brain tissue was obtained for light microscopic (LM) examination using hematoxylin-eosin (HE) and Luxol fast blue staining, and for electron microscopic examination. The LM examination with HE staining revealed normal histological findings in the greater part of an embolized lesion. Cystic change was observed in the gray matter of 8 cats, while in the gray and white matter of 3 cats. At LM examination, Luxol fast blue, staining demonstrated demyelination around the cystic change occurring in the white matter, and EM examination of the embolized cortex revealed sporadic intracapillary fat vacuoles (n=11) and disruption of the blood-brain barrier (n=4). Most lesions were normal, however, and perivascular interstitial edema and cellular swelling were mild compared with the control side. The greater part of an embolized lesion showed reversible findings at MR and histological examination. Irreversible focal necrosis was, however, observed in gray and white matter at weeks 3.

  • PDF

Assessment of the Location of the Peroneus Longus Tendon in the Cuboid Groove Using 3D Isotropic Fast Spin-Echo MRI

  • Lee, Ji Yoon;Choo, Hye Jung;Lee, Sun Joo;Jung, Joon-Yong;Kim, Dong Wook;Baek, Jin Wook;Heo, Young Jin;Gwak, Heui-Chul
    • Investigative Magnetic Resonance Imaging
    • /
    • 제24권1호
    • /
    • pp.21-29
    • /
    • 2020
  • Purpose: To investigate normal location of the peroneus longus tendon (PL) in the cuboid groove by evaluating it between ankles with no significant abnormality (asymptomatic group) and those with retromalleolar PL dislocation (dislocation group) using three-dimensional isotropic fast spin-echo (3D-FSE) magnetic resonance imaging (MRI) of the ankle. Materials and Methods: Thirty-six and 32 3D-FSE ankle MRI were assigned to the asymptomatic group and the dislocation group, respectively. Using multiplanar reformatted 3D-FSE, qualitative PL location (i.e., outside, overlying, and inside in relation to the cuboid groove), quantitative PL location (i.e., distance between the proximal margins of PL and cuboid groove), and cuboid groove size were measured in lateral, middle, and medial levels of the cuboid groove. Results: In the asymptomatic group, 64%, 42%, and 11%, respectively, had the outside or overlying-located PL in lateral, middle, and medial levels of the cuboid groove and the quantitative location gradually decreased from lateral to medial level. Qualitative and quantitative PL locations were not significantly different between the asymptomatic group and dislocation group. Cuboid groove size showed significant negative correlation with quantitative PL location in both groups. Conclusion: Outside- or overlying-located PL in lateral and middle levels of the cuboid groove would be a normal finding, regardless of PL status at the retromalleolar level.

Dual Echo 영상의 동시 획득을 위한 새로운 Fast Spin Echo 자기 공명 영상법 (A New Fast Spin Echo MR Imaging Technique for the Simultaneous Dual Echo Image Acquisition)

  • 조민형;이수열
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권1호
    • /
    • pp.91-100
    • /
    • 1998
  • 자기 공명 영상에서 최근에 개발된 fast spin echo 영상법은 종래에 사용되었던 spin echo 영상법과 거의 같은 화질과 contrast를 제공하면서도 8-16배 이상 촬영 시간이 단축되어 임상적으로 많이 사용되는 촬영 방법 중의 하나로 자리 잡았다. 그러나 종래의 spin echo영상법과는 달리, 동시에 spin밀도 영상과T 강조 영상을 제공하는 dual echo 영상법은 fast spin echo의 경우, 촬영 시간이 2배로 늘어나기 때문에 그 중요한 장점을 잃어 버리게 되었다. 본 논문에서는 dual echo를 동시에 얻기 위한 현재의 fast spin echo 영상법의 이와 같은 단점을 해결하는 새로운 영상법을 제안한다. 새로운 영상법은 기존의 fast spin echo와 거의 같은 화질을 제공하면서도 dual echo 영상을 얻는데 추가 촬영 시간을 요구하지 않는다. 이를 입증하기 위하여 인체 실험을 수행하였고 그 결과를 기존의 방법으로 얻은 영상과 비교함으로써 그 유용성을 보인다.

  • PDF

회전 경사자계와 사상 재구성을 이용한 무소음 자기 공명 영상법 (Silent Magnetic Resonance Imaging Using Rotating and Projection Reconstruction)

  • 정성택;박세혁;조장희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.555-558
    • /
    • 1997
  • A new approach to silent MR imaging using a rotating DC gradient has been explored and experimentally studied. As is known, acoustic or sound noise has been one of the major problems in handling patients, mainly due to the fast gradient pulsings in interaction with the main magnetic field. The sound noise is also proportionally louder as the magnetic field strength becomes larger. In this article, we have described a new imaging technique using a mechanically rotating DC gradient coil as an approach toward silent MR imaging, i.e., a mechanically rotated DC gradient effectively replaces both the phase encoding as well as the readout gradient pulsings and data obtained in this manner provides a set of project ion data which later can be used or the projection reconstructionorwithsomeinterpolation techniques one can also perform conventional 2-D FFT (Fast Fourier Transform) image reconstruction. We found, with this new technique, that the sound noise intensity compared with the conventional imaging technique, such as spin echo sequence, is reduced down to -20.7 dB or about 117.5 times. The experimental pulse sequence and its principle are described and images obtained by the new silent MR imaging technique are reported.

  • PDF

A NOTE ON OPTIMAL RECONSTRUCTION OF MAGNETIC RESONANCE IMAGES FROM NON-UNIFORM SAMPLES IN k-SPACE

  • Lee, June-Yub
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제14권1호
    • /
    • pp.35-42
    • /
    • 2010
  • A goal of Magnetic Resonance Imaging is reproducing a spatial map of the effective spin density from the measured Fourier coefficients of a specimen. The imaging procedure can be done by inverse Fourier transformation or backward fast Fourier transformation if the data are sampled on a regular grid in frequency space; however, it is still a challenging question how to reconstruct an image from a finite set of Fourier data on irregular points in k-space. In this paper, we describe some mathematical and numerical properties of imaging techniques from non-uniform MR data using the pseudo-inverse or the diagonal-inverse weight matrix. This note is written as an easy guide to readers interested in the non-uniform MRI techniques and it basically follows the ideas given in the paper by Greengard-Lee-Inati [10, 11].

고속 DSP를 이용한 실시간 자기공명영상시스템 제어 (Real-time Interactive Control of Magnetic Resonance Imaging System Using High-speed Digital Signal Processors)

  • 안창범;김휴정;이흥규
    • 전자공학회논문지SC
    • /
    • 제40권5호
    • /
    • pp.341-349
    • /
    • 2003
  • 고속 디지털신호처리기를 사용한 자기공명영상 실시간 대화형 제어기(스펙트로미터)를 개발하였다. 개발린 제어기는 rf 파형과 경사자계 파형을 만들고, 신호 측정을 위한 다중 측정기를 제어한다. TMS320C6701과 간은 높은 계산 능력을 가진 디지털신호처리기를 사용함으로써 복잡한 경사자계파형의 실시간 계산 및 출력이 가능해졌다. 또한 회전 행렬을 실시간으로 계산함으로써 심장과 같이 움직임이 큰 장기의 실시간 영상에서 얻고자하는 평면을 대화식으로 조절이 가능해졌다. 개발된 스펙트로미터를 1.5 테슬라 전신자기공명 영상시스템에 성공적으로 적용하였다. 개발된 스펙트로미터를 고속스핀에코나 echo planar imaging(EPI) 등과 같은 초고속자기공명영상에 적용하여 성능을 검증하였다. 이것은 이들 초고속 자기공명영상기법들이 측정 시간을 단축해주는 대신에 스펙트로미터의 송신부와 수신부 또는 경사자계부간의 동기나 위상에 에러가 있을 경우 문제점을 크게 부각시켜 시스템의 성능 평가에 적합하기 때문이다.

부분적인 경사자계를 이용한 고속 자기공명 영상촬영기법 (Fast MR Imaging Technique by Using Locally-Linear Gradient Field)

  • 양윤정;이종권
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권1호
    • /
    • pp.93-98
    • /
    • 1996
  • The purpose of this paper is to propose a new localized imaging method of reduced imaging time luting a locally-linear gradient. Since most fast MR(Magnetic Resonance) imaging methods need the whole $\kappa$-space(Spatial frequency space) data corresponding to the whole imaging area, there are limitstions in reducing the minimum imaging time. The imaging method proposed in this paper uses a specially-made gradient coil generating a local ramp-shape field and uniform field outside of the imaging areal Conventional imaging sequences can be used without any RF/gradient pulse sequence modifiestions except the change in the number of encoding steps and the field of view.

  • PDF

Comparison of Contrast-Enhanced T2 FLAIR and 3D T1 Black-Blood Fast Spin-Echo for Detection of Leptomeningeal Metastases

  • Park, Yae Won;Ahn, Sung Jun
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권2호
    • /
    • pp.86-93
    • /
    • 2018
  • Purpose: Imaging plays a significant role in diagnosing leptomeningeal metastases. However, the most appropriate sequence for the detection of leptomeningeal metastases has yet to be determined. This study compares the efficacies of contrast-enhanced T2 fluid attenuated inversion recovery (FLAIR) and contrast-enhanced 3D T1 black-blood fast spin echo (FSE) imaging for the detection of leptomeningeal metastases. Materials and Methods: Tube phantoms containing varying concentrations of gadobutrol solution were scanned using T2 FLAIR and 3D T1 black-blood FSE. Additionally, 30 patients with leptomeningeal metastases were retrospectively evaluated to compare conspicuous lesions and the extent of leptomeningeal metastases detected by T2 FLAIR and 3D T1 black-blood FSE. Results: The signal intensities of low-concentration gadobutrol solutions (< 0.5 mmol/L) on T2 FLAIR images were higher than in 3D T1 black-blood FSE. The T2 FLAIR sequences exhibited significantly greater visual conspicuity scores than the 3D T1 black-blood sequence in leptomeningeal metastases of the pial membrane of cistern (P = 0.014). T2 FLAIR images exhibited a greater or equal extent (96.7%) of leptomeningeal metastases than 3D T1 black-blood FSE images. Conclusion: Because of its high sensitivity even at low gadolinium concentrations, contrast-enhanced T2 FLAIR images delineated leptomeningeal metastases in a wider territory than 3D T1 black-blood FSE.