• 제목/요약/키워드: Fast Spectrum

검색결과 453건 처리시간 0.023초

A Compact Tunable VCSEL and a Built-in Wavelength Meter for a Portable Optical Resonant Reflection Biosensor Reader

  • Ko, Hyun-Sung;Kim, Bong-Kyu;Kim, Kyung-Hyun;Huh, Chul;Kim, Wan-Joong;Hong, Jong-Cheol;Park, Seon-Hee;Yang, Seong-Seok;Jang, Ho-Jin;Sung, Gun-Yong
    • Journal of the Optical Society of Korea
    • /
    • 제14권4호
    • /
    • pp.395-402
    • /
    • 2010
  • This study reports a portable and precision photonic biosensor reader that can measure the concentration of a particular antigen using an optical resonant reflection biosensor (ORRB). To create a compact biosensor reader, a compact tunable vertical-cavity surface-emitting laser (VCSEL) and a compact built-in wavelength meter were manufactured. The wavelength stability and accuracy of the compact built-in wavelength meter were measured to be less than 0.02 nm and 0.06 nm, respectively. The tunable VCSEL emission wavelength was measured with the compact built-in wavelength meter, it has a fast sweep time (~ 10 seconds) and a wide tuning range (> 4 nm) that are sufficient for biosensor applications based on ORRB. The reflection spectrum of a plastic based ORRB chip was measured by the fabricated portable photonic biosensor reader using the VCSEL and wavelength meter. Although the reader is the size of a palmtop device, it could make a precise measurement of the peak wavelength on equal terms with a conventional bulky optical spectrometer.

DEEP-South: The Progress Report

  • Moon, Hong-Kyu;Kim, Myung-Jin;Park, Jintae;JeongAhn, Youngmin;Yang, Hongu;Lee, Hee-Jae;Kim, Dong-Heun;Roh, Dong-Goo;Choi, Young-Jun;Yim, Hong-Suh;Lee, Sang-Min;Kwak, SungWon
    • The Bulletin of The Korean Astronomical Society
    • /
    • 제43권1호
    • /
    • pp.42.1-42.1
    • /
    • 2018
  • Deep Ecliptic Patrol of the Southern Sky (DEEP-South) observation is being made during the off-season for exoplanet survey, using Korea Microlensing Telescope Network (KMTNet). An optimal combination of its prime focus optics and the 0.3 billion pixel CCD provides a four square degrees field of view with 0.4 arcsec/pixel plate scale which is also best suited for small body studies. Normal operation of KMTNet started in October 2015, and a significant portion of the allocated telescope time for DEEP-South is dedicated to targeted observation, Opposition Census (OC), of near-Earth asteroids for physical and taxonomic characterization. This is effectively achieved through multiband, time series photometry using Johnson-Cousins BVRI filters. Uninterrupted monitoring of the southern sky with KMTNet is optimized for spin characterization of a broad spectrum of asteroids ranging from the near-Earth space to the main-belt, including binaries, asteroids with satellites, slow/fast- and non-principal axis-rotators, and thus is expected to facilitate the debiasing of previously reported lightcurve observations. Our software subsystem consists of an automated observation scheduler, a pipelined data processing system for differential photometry, and an easy-to-use lightcurve analysis toolkit. Lightcurves, spin periods and provisional determination of class of asteroids to which the lightcurve belongs will be presented, using the dataset from first year operation of KMTNet. Our new taxonomic classification scheme for asteroids will also be summarized.

  • PDF

A Study on EEG based Concentration Transmission and Brain Computer Interface Application (뇌파기반 집중도 전송 및 BCI 적용에 관한 연구)

  • Lee, Chung-Heon;Kwon, Jang-Woo;Kim, Gyu-Dong;Hong, Jun-Eui;Shin, Dae-Seob;Lee, Dong-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • 제46권2호
    • /
    • pp.41-46
    • /
    • 2009
  • This research measures EEG signals which are generating on head skin and extracts brain concentration level related with brain activity. We develop concentration wireless transmission system for controlling hardware by using this signal. Two channels are used for measuring EEG signal on front head and Biopac system with MP100 and EEG100C was used for measuring EEG signal, amplifying and filtering the signal. LabView 8.5 was also used for FFT transformation, frequency and spectrum analysis of the measured EEG signals. As a result, SMR wave, Mid-Bata wave, $\Theta$ wave classified. We extracted the concentration index by adapting concentration extraction algorithm. This concentration uldex was transferred into logo automobile device by wireless module and applied for BCI application.

Planar measurements of OH and $O_{2}$ number density in premixed $C_{3}$H$_{8}$O$_{2}$ flame using laser induced pre-dissociative fluorescence (레이저 유도 선해리 형광법(LIPE)을 이용한 화염내 OH 및 $O_{2}$ 분자의 2차원 농도 분포 측정)

  • Jin, Seong-Ho;Nam, Gi-Jung;Kim, Hoi-San;Chang, Nae-Kak;Park, Seung-Han;Kim, Ung;Park, Kyoung-Suk;Shim, Kyoung-Hoon;Kim, Gyung-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제20권12호
    • /
    • pp.4044-4052
    • /
    • 1996
  • Planar images of OH and $O_{2}$ with tunable KrF excimer laser which has a) 0.5 $cm^{-1}$ / linewidth, b) 0.5 nm tuning range, c) 150 mJ pulse energy, and d) 20 ns pulse width are obtained to determine spatial distributions of OH and $O_{2}$ in premixed $C_{3}$H$_{8}$ /O$_{2}$ flame. The technique is based on planar laser induced pre-dissociative fluorescence(PLIPF) in which collisional quenching is almost avoided because of the fast pre-dissociation. Dispersed LIPF spectra of OH and $O_{2}$ are also measured in a flame in order to confirm the excitation of single vibronic state of OH and $O_{2}$, OH and $O_{2}$ are excited on the P$_{2}$(8) line of the $A^{2}$.SIGMA.$^{+}$(v'= 3)-X$^{2}$.PI.(v'||'||'&'||'||'quot;= 0) band and R(17) line of the Schumann-Runge band B$^{3}$.SIGMA.$_{u}$ $^{[-10]}$ (v'= 0)- X$^{3}$.SIGMA.$_{g}$ $^{[-10]}$ (v'||'||'&'||'||'quot;= 6), respectively. Dispersed OH and $O_{2}$ spectra show an excellent agreement with simulated spectrum and previous works done by other group respectively. It is confirmed that OH widely distributed around flame front area than $O_{2}$.

Quality Improvement of Low Bitrate HE-AAC using Linear Prediction Pre-processor (저 전송률 환경에서 선형예측 전처리기를 사용한 HE-AAC의 성능 향상)

  • Lee, Jae-Seong;Lee, Gun-Woo;Park, Young-Chul;Youn, Dae-Hee
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • 제34권8C호
    • /
    • pp.822-829
    • /
    • 2009
  • This paper proposes a new method of improving the quality of High Efficiency Advanced Audio Coding (HE-AAC). HE-AAC encodes input source by allocating bits for each scalefactor bands appropriately according to human ear's psychoacoustic property. As a result, insufficient bits are assigned to the bands which have relatively low energy. This imbalance between different energy bands can cause decreasing of sound quality like musical noise. In the proposed system, a Linear Prediction (LP) module is combined with HE-AAC as a pre-processor to improve sound quality by even bits distribution. To apply accurate human being's psychoacoustic property, the psychoacoustic model uses Fast Fourier Transform (FFT) spectrum of original input signal to make masking threshold. In its implementation, masking threshold of psychoacoustic model is normalized using the LP spectral envelope in prior to quantization of the LP residual. Experimental result shows that, the proposed algorithm allocates bits appropriately for insufficient bits condition and improves the performance of HE-AAC.

Design and BER Performance Evaluation for Digital Retrodirective Array Antenna systems (디지털 역 지향성 배열 안테나 시스템 설계와 성능 평가)

  • Kim, So-Ra;Lee, Seug Hwan;Shin, Dong Jin;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • 제38A권3호
    • /
    • pp.217-223
    • /
    • 2013
  • A digital retrodirective antenna system is easy to modify and upgrade because it can control the phase information of the output signal toward opposite direction to input signal without a priori knowledge of the arrival direction. Due to this advantage, it is possible to perform fast beam tracking. In this paper, a design digital retrosirective array antenna system according to the number of antenna array by using only one digital PLL which finds angle of delayed phase and we test BER performance of this system. When we transmit data at actual communication system, the data modulated onto carrier frequency in order to shift spectrum from base band to another band. So we simulate system considering carrier frequency according to the number of antenna array. As a result, carrier frequency has no impact on the performance.

Signal Processing for MoC Brake Rattle Noise of Moving Vehicles Using Prony Analysis (프로니 분석을 이용한 주행 환경에서의 브레이크 래틀 소음 발생 특성 분석)

  • Lee, Jaecheol;Kwak, Yunsang;Park, Junhong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • 제35권4호
    • /
    • pp.245-250
    • /
    • 2015
  • To verify the possibility of generating rattling noise from a motor on caliper brake system, a test was conducted using a caliper excited with vibrations similar to that in a vehicle running on actual roads; this test was conducted using a quiet shaker installed in an anechoic room. After several hours of external excitation, the test assembly was loosened, and the frequency of rattling noise generation increased. A microphone was used to record the generated noise. The measured signals were analyzed by conventional spectrum analysis. Since the noise is generated as an impact response, the advantages of employing Prony analysis was discussed, and the results were compared to those obtained using conventional fast Fourier transforms. The accuracy of Prony analysis was through endurance tests on different brake systems.

Creating Highly Sensitive and Selective Biochip Sensors for the Detection of Organophosphorus/carbamate Pesticides (고감도 및 고선택성의 유기인계/카바메이트계 농약 검출용 바이오칩 센서)

  • Sim, Hyerim;Kim, Suhee;Lee, Jaeyoung;Lee, Hye Jin
    • Applied Chemistry for Engineering
    • /
    • 제20권6호
    • /
    • pp.571-580
    • /
    • 2009
  • Biochip sensing technologies offering in-situ, fast and real-time measurements in addition to portability can be powerfully utilized in a wide spectrum of research areas including environmental science, food science, medical diagnostics and drug development. In this article, we introduce current research trends and economic aspects of the development of various optical biochip technologies for the analysis of organophosphorus/carbamate pesticides in environmental samples, which is of global importance with serious consequences for both current and future generations. In particular, we will highlight recent efforts made in the creation of highly sensitive and selective optical biochip sensors in conjunction with nanobiotechnologies and microfabrication for the rapid detection of organophosphorus/carbamate pesticides.

Source Localization Technique for Radar Pulse Emission by Using Scanning Method of Interest Area (관심영역 스캐닝기법을 이용한 레이더 펄스 발생원 위치 추정기법)

  • Choi, Kyong-Sik;Kim, Jong-Pil;Won, Hyeon-Kwon;Park, Jae-Hyun;Kim, In-Gyu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • 제39권9호
    • /
    • pp.889-895
    • /
    • 2011
  • In recent days, some techniques to prevent from radar detection have been applied on aircraft system. RWR(Radar Warning Receiver) can be used for estimating the source location of the aircraft which emits radar pulse. Current existing method of localizing radar pulse emission source is using AOA(Angle Of Arrival) and most techniques are focused on finding exact AOA to find exact location. In this case, however, the exact AOA does not always result in finding exact source location while target aircraft is moving fast. In this paper, a localization method using the phase delay of the radar pulse's low frequency applies and so a scanning method for the interest area does in order to estimate exact source location by using phase delay.

Use of Near Infrared Spectroscopy in the Meat Industry

  • Akselsen, Thorvald M.
    • Proceedings of the Korean Society for Food Science of Animal Resources Conference
    • /
    • 한국축산식품학회 2000년도 국제심포지엄 및 제26차 추계학술발표회
    • /
    • pp.1-14
    • /
    • 2000
  • The Near Infrared region of the energy spectrum was first discovered by Hershel in the year 1800. The principles of NIR is based on light absorption of specific organic chemical bonds. The absorption at each wavelength is measured and a spectre is obtained. The spectre is then treated mathematically and with the absorption data is converted to absolute units via a calibration. In the last two decades it has developed dramatically. With the invention of computers and the ability to treat a large amount of data in a very short time the use of NIR for many different purposes has developed very fast. During the last decade with the aid of very powerful PC's the application of NIR technology has become even more widespread. Now or days development of very robust calibrations can be done in a relatively short time with a minimum of resources. The use of Near Infrared Spectroscopy (NIR) in the Meat industry is relatively new. The first installations were taken into operation in the 80ties. The Meat Industry in often referred to as rather conservative and slow to embrace new technologies, they stay with the old and proven methods. The first NIR instruments used by the Meat Industry, and most other industries, were multipurpose build, which means that the sample presentation was not well suited to this particular application, or many other applications for that sake. As the Meat Industry grows and develops to meet the demands of the modern markets, they realise the need for better control of processes and final products. From the early 90 ties and onward the demand for 'rear time' rapid results starts growing, and some suppliers of NIR instruments (and instruments based on other technologies, like X-ray) start to develop and manufacture instrumentation dedicated to the particular needs of the Meat Industry. Today it is estimated that there are approximately 2000 rapid instruments placed in the Meat industry world-wide. By far most of these are used as at-line or laboratory installations, but the trend and need is moving towards real on-line or in-line solutions. NIR is the most cost effective and reproducible analytical procedure available for the twenty first century.

  • PDF