• Title/Summary/Keyword: Faraday Induction Law

Search Result 11, Processing Time 0.028 seconds

Smart Passive System Based on MR Damper (MR댐퍼 기반의 스마트 수동제어 시스템)

  • Cho, Sang-Won;Jo, Ji-Seong;Kim, Chun-Ho;Lee, In-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.1 s.41
    • /
    • pp.51-59
    • /
    • 2005
  • Magnetorheological(MR) dampers are one of the most promising semi active control devices, because they have advantages such as small power requirement, reliability, and low price to manufacture. To reduce the responses of structures with MR dampers, a control system including power supply, controller, and sensors is required. However, when a mount of MR dampers are used to a large?scale civil structure such as cable stayed bridges, the control system becomes complex. Therefore, it is not easy to install and maintain the MR damper based control system. To resolve above difficulties, This paper proposes a smart passive system that consists of a MR damper and an electromagnetic induction(EMI) system. According to the Faraday’s law of induction, EMI system that is attached to the MR damper produces electric energy. The produced energy is supplied to the MR damper. Thus, the MR damper with EMI system does not require any power at all. Furthermore, the induced electric energy is proportional to external loads like earthquakes, which means the MR damper with EMI system is adaptable to external loads without any controller and corresponding sensors. Therefore, it is easy to build up and maintain the proposed smart passive system.

A Study on the Disk Type MHD Generator Using a Shock Tube (충격파관을 이용한 DISK형 MHD발전기에 관한 연구)

  • 배철오;신명철;김윤식;길경석
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.2
    • /
    • pp.447-453
    • /
    • 1999
  • In MHD power generation system, enthalpy of the working gas is convened to electric power directly through expansion in generator channel. It means that electric power can be generated without a moving mechanical linkage such as turbine blades. The principle of MHD generation is based on Faraday'law of induction that eletromotive force(u$\times$B) is generated when the working gas of velocity u flows a channel in which magnetic field of strength(B) exists. In this paper, helium gas seeded with cesium is used as working gas. There are two types of generator in MHD generation; linear type faraday and disk type hall generator. Rogowski coils having the bandwidth of the 100(Hz) ~ 20(kHz) were used for measuring current flowing MHD disk channel. Optimum load resistor value of the MHD generator studied was 2.5[$\Omega$]. Disk type hall generator's generation performance is the main target of this paper, which superiors to linear type Faraday generator in many points. Isentropic efficiency and enthalpy extraction rate of disk type shock tube driven hall generator is discussed here.

  • PDF

A Study on Enthalpy Extraction Rate and Isentropic Efficiency of the Disk Type Generator using a Shock Tube (충격파관을 이용한 DISK형 MHD발전기의 엔탈피추출율과 단열효율에 관한 연구)

  • Bae, C.O.;Kim, Y.S.;Park, Y.S.;Shin, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.1981-1983
    • /
    • 1998
  • The principle of the MHD generation is based on Faraday's law of induction that a eletromotive force(u ${\times}$ B) is generated when the working gas of velocity u flows a channel in which magnetic field of strength(B) exists. In MHD power generation system, enthalpy of the working gas is converted to electric power directly through expansion in generator channel. It means that electric power can be generated without moving mechanical linkage such as turbine blades. There are two types in the MHD generator; linear type Faraday and disk type hall generator. Disk type hall generator is the main target of this paper. Isentropic efficiency and enthalpy extraction rate of disk type shock tube driven hall generator is discussed here.

  • PDF

Study on the Magnetic Field Measurement Using the Ultrasonic Transducer (초음파진동자를 이용한 자계측정방법 연구)

  • 손은영;류주현;윤광희;정영호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.350-355
    • /
    • 1997
  • A new magnetic field measuring system with induced coil is reported. This system consists of air-cared coil that is forced by the ultrasonic transducer. Induction voltage of coil is proportional to the DC magnetic field and the driving frequency of ultrasonic transducer by the principle of Faraday's law. The experimental measuring system is setup, and the possibility of a new magnetic field sensors is confirmed.

  • PDF

Performance Evaluation of the New Smart Passive Control Device using Shaking Table Test (진동대 실험을 통한 신개념 스마트 수동제진장치의 제진성능 평가)

  • Jang, Dong-Doo;Jung, Hyung-Jo;Moon, Seok-Jun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.1
    • /
    • pp.27-35
    • /
    • 2010
  • This paper presents the vibration control performance of the smart passive control system to suppress the undesired vibration of the structure subjected to the earthquake loadings. Smart passive control system is the MR damper-based control system augmented with electromagnetic induction(EMI) device which consists of permanent magnets and solenoid coils. According to the Faraday's law of electromagnetic induction, an EMI device produces electrical energy from the mechanical energy due to the reciprocal motions of the structure and provide it to the MR damper. The smart passive control system can be the simple and easy to implement and maintain control system by replacing the feedback control system including sensors, controllers and external power sources of the conventional MR damper-based semiactive control system with the EMI device. The control performance of the smart passive control system is evaluated through the set of shaking table test considering the various historical earthquake loadings.

Seismic protection of base isolated structures using smart passive control system

  • Jung, Hyung-Jo;Choi, Kang-Min;Park, Kyu-Sik;Cho, Sang-Won
    • Smart Structures and Systems
    • /
    • v.3 no.3
    • /
    • pp.385-403
    • /
    • 2007
  • The effectiveness of the newly developed smart passive control system employing a magnetorheological (MR) damper and an electromagnetic induction (EMI) part for seismic protection of base isolated structures is numerically investigated. An EMI part in the system consists of a permanent magnet and a coil, which changes the kinetic energy of the deformation of an MR damper into the electric energy (i.e. the induced current) according to the Faraday's law of electromagnetic induction. In the smart passive control system, the damping characteristics of an MR damper are varied with the current input generated from an EMI part. Hence, it does not need any control system consisting of sensors, a controller and an external power source. This makes the system much simpler as well as more economic. To verify the efficacy of the smart passive control system, a series of numerical simulations are carried out by considering the benchmark base isolated structure control problems. The numerical simulation results show that the smart passive control system has the comparable control performance to the conventional MR damper-based semiactive control system. Therefore, the smart passive control system could be considered as one of the promising control devices for seismic protection of seismically excited base isolated structures.

Modeling of Magnetotelluric Data Based on Finite Element Method: Calculation of Auxiliary Fields (유한요소법을 이용한 MT 탐사 자료의 모델링: 보조장 계산의 고찰)

  • Nam, Myung-Jin;Han, Nu-Ree;Kim, Hee-Joon;Song, Yoon-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.2
    • /
    • pp.164-175
    • /
    • 2011
  • Using natural electromagnetic (EM) fields at low frequencies, magnetotelluric (MT) surveys can investigate conductivity structures of the deep subsurface and thus are used to explore geothermal energy resources and investigate proper sites for not only geological $CO_2$ sequestration but also enhanced geothermal system (EGS). Moreover, marine MT data can be used for better interpretation of marine controlled-source EM data. In the interpretation of MT data, MT modeling schemes are important. This study improves a three dimensional (3D) MT modeling algorithm which uses edge finite elements. The algorithm computes magnetic fields by solving an integral form of Faraday's law of induction based on a finite difference (FD) strategy. However, the FD strategy limits the algorithm in computing vertical magnetic fields for a topographic model. The improved algorithm solves the differential form of Faraday's law of induction by making derivatives of electric fields, which are represented as a sum of basis functions multiplied by corresponding weightings. In numerical tests, vertical magnetic fields for topographic models using the improved algorithm overcome the limitation of the old algorithm. This study recomputes induction vectors and tippers for a 3D hill and valley model which were used for computation of the responses using the old algorithm.

The measurement for contactless eddy-current conductivity on Si wafer (와전류(eddy-current)방법에 의한 비접촉 전기비저항 측정기술 개발)

  • Park, Jin-Sueb;Ryu, Kwon-Sang;Ryu, Je-Cheon;Yu, Kwang-Min
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.991-993
    • /
    • 1999
  • The method of measurement for contactless eddy-current conductivity using magnetic dipole field theory was suggested by M.C Chen[1], which calculate the eddy-current caused by exciting coil with Faraday's induction law. In this work, we have developed the apparatus for contactless measurement of conductivity or resistivity with the dipole field theory. The resistivity can be measured from several to a dozen $m{\Omega}{\cdot}cm$ range within maximum 30% error. At the high resistivity range above $100{\Omega}{\cdot}cm$, the standard deviation of measurement was very large as the induced voltage of sensing coil is small so it was difficult to measure the value precisely.

  • PDF

Seismic Performance Improvement of Base Isolated Buildings using Smart Passive Control System (스마트 수동 제어 시스템을 이용한 면진 건물의 내진 성능 개선)

  • Jung, Hyung-Jo;Jung, Chan-Kuk;Choi, Kang-Min;Lee, In-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.6 s.52
    • /
    • pp.37-46
    • /
    • 2006
  • In this study, the efficacy of the newly developed smart passive control system to improve seismic performance of base isolated building structures is numerically verified. The smart passive control system consists of a magnetorheological (MR) damper and an electromagnetic induction (EMI) part. The damping characteristics of an MR damper can be controlled by the current generated in an EMI part according to the Faraday's law of electromagnetic induction. An EMI part consisting of a permanent magnet and a solenoid coil could substitute a control system including sensors, a controller and an external power supply in a conventional smart control system. The benchmark control problem for a base isolated building presented by the american society of civil engineers is considered for numerical simulation. The control performance of the smart passive control system is compared to that of the conventional smart control system using MR dampers. It is demonstrated from the numerical simulation results that the smart passive control system is useful to improve the seismic performance of base isolated buildings.

Study on Vibration Energy Harvesting with Small Coil for Embedded Avian Multimedia Application

  • Nakada, Kaoru;Nakajima, Isao;Hata, Jun-ichi;Ta, Masuhisa
    • Journal of Multimedia Information System
    • /
    • v.5 no.1
    • /
    • pp.47-52
    • /
    • 2018
  • We have developed an electromagnetic generator to bury in subcutaneous area or abdominal cavity of the birds. As we can't use a solar battery, it is extremely difficult to supply a power for subcutaneous implantation such as biosensors under the skin due to the darkness environment. We are aiming to test the antigen-antibody reaction to confirm an avian influenza. One solution is a very small generator with the electromagnetic induction coil. We attached the developed coil to chickens and pheasants and recorded the electric potential generated as the chicken walked and the pheasant flew. The electric potential generated with physical simulator is equal to or exceeds the 7 V peak-to-peak at maximum by 560/min of flapping of wings. Even if we account for the junction voltage of the diode (200 mV), efficient charging of the double-layer capacitor is possible with the voltage doubler rectifier. If we increase the voltage, other problems arise, including the high-voltage insulation of the double-layer capacitor. For this reason, we believe the power generated to be sufficient for subcutaneous area of birds. The efficiency, magnetic 2 mm in length and coil 15mm in length, if axial direction is rectified, the magnetic flux density given to the coil could calculated to 7.1 % and generated power average 0.47mW. The improvements in size and wire insulation are expected in the future.