• Title/Summary/Keyword: Fan-beam CT

Search Result 17, Processing Time 0.022 seconds

The resolution recovery - Application to various CT systems

  • Kim, Hong-Suk;Lee, Soo-Young
    • Proceedings of the KIEE Conference
    • /
    • 1979.08a
    • /
    • pp.160-161
    • /
    • 1979
  • The degradation of image due to the finite size of sensing device has been one of the problems to all of the digital imaging systems. The improvement of the spatial resolution has been attempted by "differential method" with fixed sensor size and finer sampling. The computer simulations were carried out for the cases of PLF system (Parallel Linear Fan-beam) and SR(Stationary Ring) system and the results are presented.

  • PDF

Implementation of 3D Video using Time-Shortening Algorithm (시간단축 알고리즘을 통한 3D 동영상 구현)

  • Shin, Jin-Seob;Jeong, Chan-Woong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.6
    • /
    • pp.123-128
    • /
    • 2020
  • In this paper, we presents a new cone beam computerized tomography (CBCT) system for the reconstruction of 3 dimensional dynamic images. The system using cone beam has less the exposure of radioactivity than fan beam, relatively. In the system, the reconstruction 3-D image is reconstructed with the radiation angle of X-ray in the image processing unit and transmitted to the monitor. And in the image processing unit, the Three Pass Shear Matrices, a kind of Rotation-based method, is applied to reconstruct 3D image because it has less transcendental functions than the one-pass shear matrix to decrease a time of calculations for the reconstruction 3-D image in the processor. The new system is able to get 3~5 3-D images a second, reconstruct the 3-D dynamic images in real time. And we showed the Rotation-based method was good rather than existing reconstruction technique for 3D images, also found weakness and a solution for it.

Image Reconstruction of Sinogram Restoration using Inpainting method in Sparse View CT (Sparse view CT에서 inpainting 방법을 이용한 사이노그램 복원의 영상 재구성)

  • Kim, Daehong;Baek, Cheol-Ha
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.655-661
    • /
    • 2017
  • Sparse view CT has been widely used to reduce radiation dose to patient in radiation therapy. In this work, we performed sinogram restoration from sparse sampling data by using inpainting method for simulation and experiment. Sinogram restoration was performed in accordance with sampling angle and restoration method, and their results were validated with root mean square error (RMSE) and image profiles. Simulation and experiment are designed to fan beam scan for various projection angles. Sparse data in sinogram were restored by using linear interpolation and inpainting method. Then, the restored sinogram was reconstructed with filtered backprojection (FBP) algorithm. The results showed that RMSE and image profiles were depended on the projection angles and restoration method. Based on the simulation and experiment, we found that inpainting method could be improved for sinogram restoration in comparison to linear interpolation method for estimating RMSE and image profiles.

Digital Tomosynthesis for Patient Alignment System Using Half-fan Mode CBCT Projection Images (Half-fan 모드를 이용한 방사선치료환자 위치교정을 위한 디지털영상 합성영상기술에 관한 예비연구)

  • Park, Justin C.;Park, Sung-Ho;Kim, Jin-Sung;Han, Young-Yih;Ju, Sang-Gyu;Shin, Eun-Hyuk;Shin, Jung-Suk;Park, Hee-Chul;Ahn, Yong-Chan;Song, Willian Y.
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.360-366
    • /
    • 2010
  • To generate on-board digital tomosynthesis (DTS) for three-dimensionalimage-guided radiation therapy (IGRT) as an alternative to conventional portal imaging or on-board cone-beam computed tomography (CBCT), two clinical cases (liver and bladder) were selected to illustrate the capabilities of on-board DTS for IGRT. DTS images were generated from subsets of CBCT projection data (45, 162 projections) using half-fan mode scanning with a Feldkamp-type reconstruction algorithm. Digital tomosynthesis slices appeared similar to coincident CBCT planes and yielded substantially more anatomic information. Improved bony and soft-tissue visibility in DTS images is likely to improve target localization compared with radiographic verification techniques and might allow for daily localization of a soft-tissue target. Digital tomosynthesis might allow targeting of the treatment volume on the basis of daily localization.

Study of Scatter Influence of kV-Conebeam CT Based Calculation for Pelvic Radiotherapy (골반 방사선 치료에서 산란이 kV-Conebeam CT 영상 기반의 선량계산에 미치는 영향에 대한 연구)

  • Yoon, KyoungJun;Kwak, Jungwon;Cho, Byungchul;Kim, YoungSeok;Lee, SangWook;Ahn, SeungDo;Nam, SangHee
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.37-45
    • /
    • 2014
  • The accuracy and uniformity of CT numbers are the main causes of radiation dose calculation error. Especially, for the dose calculation based on kV-Cone Beam Computed Tomography (CBCT) image, the scatter affecting the CT number is known to be quite different by the object sizes, densities, exposure conditions, and so on. In this study, the scatter impact on the CBCT based dose calculation was evaluated to provide the optimal condition minimizing the error. The CBCT images was acquired under three scatter conditions ("Under-scatter", "Over-scatter", and "Full-scatter") by adjusting amount of scatter materials around a electron density phantom (CIRS062, Tissue Simulation Technology, Norfolk, VA, USA). The CT number uniformities of CBCT images for water-equivalent materials of the phantom were assessed, and the location dependency, either "inner" or "outer" parts of the phantom, was also evaluated. The electron density correction curves were derived from CBCT images of the electron density phantom in each scatter condition. The electron density correction curves were applied to calculate the CBCT based doses, which were compared with the dose based on Fan Beam Computed Tomography (FBCT). Also, 5 prostate IMRT cases were enrolled to assess the accuracy of dose based on CBCT images using gamma index analysis and relative dose differences. As the CT number histogram of phantom CBCT images for water equivalent materials was fitted with a gaussian function, the FHWM (146 HU) for "Full-scatter" condition was the smallest among the FHWM for the three conditions (685 HU for "under scatter" and 264 HU for "over scatter"). Also, the variance of CT numbers was the smallest for the same ingredients located in the center and periphery of the phantom in the "Full-scatter" condition. The dose distributions calculated with FBCT and CBCT images compared in a gamma index evaluation of 1%/3 mm criteria and in the dose difference. With the electron density correction acquired in the same scatter condition, the CBCT based dose calculations tended to be the most accurate. In 5 prostate cases in which the mean equivalent diameter was 27.2 cm, the averaged gamma pass rate was 98% and the dose difference confirmed to be less than 2% (average 0.2%, ranged from -1.3% to 1.6%) with the electron density correction of the "Full-scatter" condition. The accuracy of CBCT based dose calculation could be confirmed that closely related to the CT number uniformity and to the similarity of the scatter conditions for the electron density correction curve and CBCT image. In pelvic cases, the most accurate dose calculation was achievable in the application of the electron density curves of the "Full-scatter" condition.

Investigation of Ring Artifact Using Algebraic Reconstruction Technique (대수적 재구성 기법을 통한 링 아티팩트 조사)

  • Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.65-70
    • /
    • 2018
  • Computed tomography system is widely used on various fields because section image of an object can be acquired. During several step to obtain section image, artifacts by many error factors can be added on the image. Ring artifact induced by the CT system is examined in this study. A test phantom of $512{\times}512$ size was constructed numerically, and the ring artifact was investigated by the algebraic reconstruction technique. The computer program was realized using Visual C++ under the fan beam geometry with projections of 720 and detector pixel of 1,280. The generation of ring artifact was verified by applying different detection efficiency on detector pixels. The ring intensity became large as increasing the ring value, and the ring artifacts were strongly emphasized near the center of the reconstructed image. The ring artifact may be eliminated by tracking the position of ring artifact on the reconstructed image and by calibrating the detector pixel.

Comparison Study on Projection and Backprojection Methods for CT Simulation (투사 및 역투사 방법에 따른 컴퓨터단층촬영 영상 비교)

  • Oh, Ohsung;Lee, Seung Wook
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.323-330
    • /
    • 2014
  • Image reconstruction is one of the most important processes in CT (Computed tomography) technology. For fast scanning and low dose to the objects, iterative reconstruction is becoming more and more important. In the implementation of iterative reconstruction, projection and backprojection processes are considered to be indispensable parts. However, many approaches for projection and backprojection may result severe image artifacts due to their discrete characteristics and affects the reconstructed image quality. Thus, new approaches for projection and backprojection are highly demanded these days. In this paper, distance-driven approach was evaluated and compared with other conventional methods. The numerical simulator was developed to make the phantoms, and projection and backprojection images were compared using these approaches. As a result, it turned out that there are less artifacts during projection and backprojection in parallel and fan beam geometry.