압전세라믹 냉각팬에 의한 강제 공랭 모듈 주위의 유체유동과 열전달 특성 (Fluid Flow and Heat Transfer Characteristics around a Surface-Mounted Module Cooled by Forced Air Flow by Piezoelectric Cooling Fan)

  • 박규진;박상희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.272-277
    • /
    • 2003
  • This paper reports the fluid flow and heat transfer around a module cooled by forced air flow generated by a piezoelectric(PZT) cooling fan. A flexible PZT fan with distortion in a fluid transport system of comparatively simple structure which was mounted on a PCB in a parallel-plate channel($450{\times}80{\times}700mm^3$) accelerates surrounding fluid locally. Input voltages of 20-100V and a resonance frequency of 23Hz were used to vibrate the cooling fan. Input power to the module was 4W. The cooling effect using a PZT fan was larger than that of free convection. Fluid flow around the module were visualized by using PIV system. The temperature distribution around heated module were visualized by using liquid crystal film(LCF). We found that the flow type was y-shaped and the cooling effect was increased by the wake generated by a piezoelectric cooling fan.

  • PDF

Conceptual Design of a Ducted Fan for Helicopter Anti-Torque System

  • Hwang, Chang-Jeon
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제6권1호
    • /
    • pp.89-96
    • /
    • 2005
  • Ducted fans have advantages in noise as well as operational safety aspects compared to conventional tail rotors and are used as an anti-torque system for various classes of helicopters. The final goal of this study is to develop a ducted fan anti-torque system which can replace conventional tail rotors of existing helicopters to achieve safety enhancement and low noise level. In this paper, a conceptual design process and the results are described. Initially, the design requirement and the design parameter characteristics are analysed, and then initial sizing and configuration design are performed. There are several configuration changes due to specific technical reasons in each case. Finally, the required power and the pitch link load are predicted as an initial estimation. The conceptual design technique for the ducted fan in this study can be easily applied to the design of other ducted fans such as the lift fan for unmanned aerial vehicle.

급기가압 제연시스템의 송풍기에 대한 실규모 성능평가 실험 (Experiments on Performance of Fan used in Pressure Differential System for Smoke Management)

  • 김정엽
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.458-462
    • /
    • 2008
  • The fact that the major cases of life casualties are from smoke in the fire accidents and the expected steep increase of skyscrapers, huge spaces, multiplexes and huge scaled underground spaces demand establishment of efficient smoke countermeasure. The core technology for development of smoke management system is analysis tool of fan used in pressure differential system. The experiments on performance of sirroco-typed fan are carried out to evaluate the features of fan and present the experimental data for numerical analysis.

  • PDF

ATmega128 마이크로 컨트롤러를 사용한 스마트 선풍기 속도제어 (Speed Control of Smart Electric Fan using ATmega128 Microcontroller)

  • 원재혁;김정운;이성준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 에너지변화시스템부문
    • /
    • pp.281-283
    • /
    • 2009
  • This paper presents the smart fan which is operated by a small conventional motor and an ultrasonic sensor. The smart fan generates cool wind with regulated speed of wing by the distance between the user and the fan. In this research, an 8-bit microcontroller (ATmega128) and an ultrasonic sensor (NT-TS601) are utilized for the system control and sensing information. In order to obtain the speed information from the encoderless DC motor, a stroboscope is used, which provides the voltage variation by the motor speed. The proposed smart fan makes the user feel cool, convenient and safe at a low cost.

  • PDF

건축물 제연시스템의 송풍기에 대한 해석기술 개발 (Development of Analysis Technology on Fan in Pressure Differential System for Smoke Management)

  • 김정엽;김지석
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2009년도 춘계학술논문발표회 논문집
    • /
    • pp.352-357
    • /
    • 2009
  • The fact that the major cases of life casualties are from smoke in the fire accidents and the expected steep increase of skyscrapers, huge spaces, multiplexes and huge scaled underground spaces demand establishment of efficient smoke countermeasure. The core technology for development of smoke management system is analysis tool of fan used in pressure differential system. The development of analysis technology on sirroco-typed fan using experimental and numerical methods are carried out to evaluate the features and performance of fan used in pressure differential systems.

  • PDF

팬-모터의 구조 및 전자기적 특성을 고려한 선박용 원심 팬의 순음 저감 분석 (Analysis for the Reduction of Tonal Noise in the Centrifugal Fan for the Ship Considering Structural and Electromagnetic Characteristics of the Fan-Motor System)

  • 한형석;장천익;이상구;구자훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.359-367
    • /
    • 2008
  • The maximum sound pressure level in a ship is restricted by the international standard such as MIL-Std. 740-1 in order to protect hearing ability for the crew on a ship. Especially, the noise of a fan system is restricted by the maximum level of the sound power according to the military specification such as MIL-F-1900A. In this paper, the reduction of tonal noise for the fan-motor system on a ship is described related to the electrical as well as structural problems. For the electrical problems, the difference of the magnetic flux caused by the variation of the air-gap is described related to the bad concentricity of the motor housing and the shaft-bearing. And for the structural problem, the resonance of the fan motor system is described.

  • PDF

에어컨용 직교류홴 시스템의 성능특성에 대한 기본적 설계변수의 영향에 관한 실험적 연구 (An Experimental Study on the Influences of Some Basic Design Parameters on the Performance Characteristics of the Cross-Flow Fan System in Air-Conditioner)

  • 구형모
    • 대한기계학회논문집B
    • /
    • 제23권6호
    • /
    • pp.695-702
    • /
    • 1999
  • A cross-flow fan which constitutes a fan-duct system with a stabilizer and a scroll-casing is widely used in many air-ventilating and air-conditioning devices. The cross-flow fan system has many design parameters which have crucial influence on the performance and the noise characteristics of the devices, which means many difficulties during the design stage of the devices and the general design guide has not sufficiently established yet. This study presents the experimental results of the parameter investigation of some chosen design parameter values, which are the shapes of the stabilizers, the profiles of the scroll casing part, and the diffusion angles of the flow exit. The results are expressed by the varying performance characteristics with the values of the parameters. They are found to have considerable effects on the system performance and should be considered with care in the design stage. Finally some helpful guides for the design and manufacturing of the cross-flow fan system are proposed.

Head up Display용 냉각시스템 (The Cooling System for Head up Display)

  • 지용석;김영섭;안병만;임상민
    • 반도체디스플레이기술학회지
    • /
    • 제9권1호
    • /
    • pp.67-71
    • /
    • 2010
  • Head up display’s cooling system is auto-diagnosed resulting from the external environment. The quantity of heat depending on this Head up display’s cooling system layout determines the speed of FAN for system cooling. In other words, a system’s heat quantity is planned through the air density depending on altitude, the amount of wind in air depending on FAN control condition, and the algorithm that is proportional to delta temperature. To detect the altitude, we use the criteria of delta T, which is determined by the subtracted value of LED junction temperature, and atmospheric temperature that is recorded on the Head up display system. Depending on the classification of delta T value, the altitude section is determined. While we can use GPS as the tool to detect the altitude, we should predict the change of the air density as the altitude alters, and should not just measure the altitude. And the value of delta T is used as the criterion of detecting the altitude for increasing the cooling efficiency of the car’s inner Head up display system with reflecting the speed of the FAN dependent upon the air density. In our theory, altitude is depending on the value of delta T and stabilizing or maintaining the system’s temperature by changing FAN’s rpm depending on determined value of altitude.

가솔린 직접분사식 고압 슬릿 노즐의 팬형 분무 특성 고찰 (Fan-shaped Spray Characteristics of High Pressure Slit Nozzle in a Gasoline Direct Injection Engine)

  • 송범근;김종민;강신재
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.2239-2244
    • /
    • 2003
  • A new stratified charge combustion system has been introduced and developed for GDI engines. Before this new GDI system, the stratified mixture was formed by a high pressure swirl injector. But, the special feature of new system is employed of a thin fan-shaped fuel spray formed by a slit type nozzle. Also, this system has been adopted a shell-shaped piston cavity. We made high pressure gasoline injection system and investigated the fan-shaped spray characteristics such as spray tip penetration, spray angle, SMD and velocities of droplets using PDPA(Phase Doppler Particle Analyzer) system and spray visualization system to obtain the concept of the new design and the fundamental data for the next generation GDI system. The experiment was performed at the injection pressures of 5 and 9MPa under the atmospheric condition.

  • PDF

프로펠라 팬과 앞판과의 간격이 팬 성능에 미치는 영향에 관한 연구 (The Study on Performance of Propeller Fan according to Distance of Front Plate)

  • 엄윤섭;부정숙;윤인철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권4호
    • /
    • pp.494-501
    • /
    • 2000
  • A study on performance of a propeller fan according to the distance between the front plate and the fan was conducted experimentally. Different characteristics of performance were found on the performance curve. Flow measurements using the three dimensional LDV system show that the zone of recirculation exists around the fan. The differences of performance in changes of the distance occurs because the zone of recirculation is much wider at the distance of 24mm than at that of 30mm.

  • PDF