• Title/Summary/Keyword: Fan heater

Search Result 59, Processing Time 0.035 seconds

Automatic Control System of Vertical Agitation Heater for Controlling Temperature of Greenhouse (시설하우스 온도 조절을 위한 수직형 교반 히터 자동제어 시스템)

  • Kwak, Yun-Ah;Park, Kyoung-Wook;Kim, Eung-Kon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.5
    • /
    • pp.623-628
    • /
    • 2015
  • As the current heating control of the greenhouse is located in specifically designed place, there is an inevitable difference in degrees depending on the latitude in it. Even though it is necessary to maintain the proper temperature in the greenhouse producing vegetables and fruit plants, the difference between ups and downs in the facilities results in the increasing energy consumption to both warm and cool down the facilities. The newest heating method, automatic control system of vertical agitation heater, which manipulates the inner air circulation efficiently, is suggested in this paper. The proposed system utilizes both the upper temperature and the lower temperature, and controls the air circulation fan and heating independently, so that maximizes the efficiency of heating with the minimum energy and implements predictable planning of farm products.

Reduction of Temperature Variation at Measurement Points of Semiconductor Test Handler (반도체 테스트 핸들러 측정점간의 온도 편차 감소)

  • Kim, Jae-Yong;Cho, Su-Young;Kang, Tae-Sam;Lee, Ho-Joon;Koh, Kwang-Ill
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.10
    • /
    • pp.77-84
    • /
    • 1998
  • The temperature difference occurs at the test points of chamber, because the traditional Test Handler consists of a heater and a fan. To reduce the temperature variation at different points in the chamber, we divided the heater to three parts which are controlled independently. First, we identified the chamber's parameter and then designed a LQG controllers by the identification model. RTD sensors and VME system were used to construct the temperature control system. In our experiment for the proposed control system, the temperature variation was reduced from ${\pm}1.5^{\circ}C$ to ${\pm}0.35^{\circ}C$ at 50$^{\circ}C$ ${\cdot}$ 80$^{\circ}C$ and 120$^{\circ}C$.

  • PDF

A study on the Development of Smoke Detector Sensitivity Test Equipment (휴대용 연기감도시험기 개발에 관한 연구)

  • Kim, Hyeong-Gweon;Kwon, Seong-Pil;Yoon, Hun-Ju;SaKong, Seong-Ho
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.125-132
    • /
    • 2009
  • In this study we could contribute to the development of a precise checking tool with which the reliability of the automatic fire detection systems was enhanced and the safety of the people was ensured. In the same way as the domestic technical standard, the portable smoke sensitivity tester, which was developed in this work, could be used to check the capability of the smoke detectors installed in the field. Its heater inside was warmed up to $400^{\circ}C$ in 40 seconds and the paper as a smoke source was burned to produce smoke for the test. With the Photoelectric smoke detector it was possible to measure and control the smoke concentration in a range from 0%/m to 25%/m. With the adjustment of rpm of the fan, it was possible to keep a constant wind velocity in a range from 20cm/sec to 40cm/sec.

Enhancement of Burner Performance of Household Gas Fired Absorption Chiller/Heaters (가정용 가스 냉난방기용 연소기의 성능개선 연구)

  • Yoon, Young-Seok;You, Hyun-Seok;Kim, Tae-Han;Lee, Joong-Seong;Han, Jeong-Ok
    • 한국연소학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.111-115
    • /
    • 1999
  • In order to enhance the burner performance of household gas fired absorption chiller/heaters, the operating condition(excess air $\approx$ 10%) of the burner currently being used was required to be optimized. In this regard, we examined where the $CO_{\min}$. emission limit was located between blow off and yellow tip limit and how much amount of excess air was exhausted by means of observing blow off and yellow tip limit. It was found that the $CO_{\min}$ limit(excess air ${\approx}$ 4%) was determined near the yellow tip limit. The effect of exhaust pressure on the $CO_{\min}$. limit was that, if exhaust pressure was higher than that in steady condition, higher air blower fan rpm is demanded to maintain the $CO_{\min}$ limit. Therefore, it was necessary to optimize the operating condition of burner in terms of a thermal efficiency and safety.

  • PDF

Design and Implementation of Real-Time Information Appliance Control Simulator Based on TMO Scheme (TMO 스키마 기반의 실시간 정보가전 제어 시뮬레이터의 설계 및 구현)

  • Jung, Eun-Jae;Shin, Chang-Sun;Joo, Su-Chong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2003.05a
    • /
    • pp.149-152
    • /
    • 2003
  • 본 논문에서는 분산 실시간 서비스를 지원하는 TMO(Time-triggered Message-triggered Object) 객체를 기반으로 정보가전 기기들을 관리하기 위한 실시간 정보가전 제어 시뮬레이터를 설계 및 구현한다. TMO객체는 기존 객체를 확장한 실시간 특성을 자체적으로 가지는 객체를 UCI의 DREAM연구소에서 제안한 분산 실시간 객체이다. 이러한 TMO 객체를 기반으로 TMOSM(TMO Support Middelware) 상에서 실시간 정보가전 제어를 위한 TMO 객체들의 상호 동작과 실시간 속성을 설계하여 보장된 실시간 서비스를 지원하도록 한다. 본 시뮬레이션 모델은 온도제어, 조도제어, 방법제어 서비스를 지원하는 컴포넌트들로 구성된다. 온도제어 서비스를 위해 Fan_TMO와 Air_Conditioner_TMO, Heater_TMO가 상호 작용하여 적정 실내 온도를 유지하도록 하며, 조도제어 서비스를 위해 Light_TMO가 조도의 변화에 따라 동작하여 일상생활에 적당한 조명 환경을 제공한다. 또한 방범제어서비스를 위해 Camera_TMO가 정해진 시간을 주기적으로 동작하여 방범 활동을 수행한다. 그리고, 각각의 TMO 정보가전 객체들의 동작을 관리하고 서비스 수행 결과를 모니터링 하는 Home_Server_TMO가 존재한다. 마지막으로 설계된 시뮬레이션 환경을 구현하여 본 모델의 실시간 정보가전 제어 서비스를 정확하게 지원하는지를 검증한다. 제안한 시뮬레이션 환경은 일반 정보가전기기를 추가 작업 없이 실시간 서비스 지원 객체로 적용할 수 있는 모델이다.

  • PDF

A STUDY ON THE EXPLOSION SAFETY ASSESSMENT OF HYDROCARBON REFRIGERANT REFRIGERATOR

  • Oh, Kyu-Hyung;Kim, Min-Kyu;Chu, Euy-Sung;Lim, Byung-Han;Kim, Man-Hoe;Park, Yoon-Ser
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.289-296
    • /
    • 1997
  • This paper discribes an experimental explosion risk assessment study on refrigerators containing flammable hydrocarbon refrigerant. A refrigerator used in this study is a larder fridge type, 215 liter in volume. The hydrocarbon refrigerant used in the refrigerator is iso-butane(C$_4$H$_{10}$). For the explosion safety assessment of the refrigerator, temperature of compressor, cooling air circulation fan motor, defrost heater and inner lamp were measured during the operation. And to confirm the ignitablity of flammable gas by the electric spark of the switches of the refrigerator, ON-OFF test of all switches were conducted with compulsorily near the stoichiometric concentration atmosphere of iso-butane-air mixture. As the result of experiment above mentioned and another experiment for the explosion safety assessment, we can conclude that explosion hazard in connection with the use of hydrocarbon refrigerant was few.w.

  • PDF

Multichannel Liquid Phase Microextraction System (다채널 액상 미세 추출 시스템 설계 및 제작)

  • Zhang, XinJie;Cheng, Shuo;Piao, Xiang Fan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.10
    • /
    • pp.1-7
    • /
    • 2020
  • In this study, a multichannel gas-liquid microextraction system is designed by integrating the automatic elution of extraction line and multichannel gas-purging liquid phase microextraction. The system uses an injection pump and inert gas to push the extraction solvent to a sample bottle of a gas-phase color autosampler and then implements multichannel gas-liquid microextraction and gas chromatography-mass spectrometry. The system also employs a three-way integrated micro-high-temperature heater, syringe pump, and microflow controller to realize the simultaneous processing of multiple groups of samples, thus improving the sample pretreatment speed and reproducibility and reducing human error. Autoinjection experiments were implemented with polycyclic aromatic hydrocarbon standard samples. The experiments show that the average recovery rate of the system exceeds 70%, and the relative standard among the channels is less than 15%.

Prevention of Barn Rot during Curing of Burley Tobacco. II. Effect of Curing Conditions and Supplemental Heat. (버어리종 잎담배 건조시 부패방지 II. 건조조건과 보조화력의 영향)

  • 배성국;임해건;한철수
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.34 no.4
    • /
    • pp.331-334
    • /
    • 1989
  • This studies were carried out to investigate the effects of the management of curing barn and the use of supplemental heat on prevention of barn rot during the rainy season. The managemental methods of curing barn were combined with hanging spaces ranged from 15cm to 30cm and ventilating conditions. The supplemental heat was applied with oil burner and oil fan heater. Barn rot was reduced in the wider hanging spaces, and the effects of hanging spaces was larger with ventilating during curing. Barn rot decreased by ventilating condition than non-ventilation. The use of supplemental heat dropped to lower relative humidity in curing barn. Supplemental heat and forced-air movement greatly reduced barn rot in comparison with tobacco cured under natural conditions.

  • PDF

A study on the Development of Automatic Drying System of Ginseng (인삼의 자동건조시스템 개발에 관한 연구)

  • Kang, Hyun-Ah;Chang, Kyu-Seob;Chang, Dong-Il
    • Korean Journal of Food Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.764-768
    • /
    • 1993
  • This study was developed a computer-controlled automatic drying system. In order to control automatically the temperature, relative humidity weight of the sample, drying system with computer and connecting parts such as microcomputer, PC-Lab card, Op. Amp., and relay system were developed for controlling the heater, fan, humidifier and dehumidifier. Using this system, drying characteristic mechanism of ginseng were investigated. The increase of drying temperature decreased Hunter L value and increased a and b value. The hardness and shrinkage rate of white ginseng had a increasing tendency with the increase of drying temperature. Crude saponin content was not affected by drying temperature and relative humidity.

  • PDF

Development of Monitoring Program for Detecting Current and Voltage Signals for Series Arc (직렬아크에 대한 전류 및 전압 신호분석이 가능한 Monitoring Program 개발)

  • Kim, Doo-Hyun;Park, Jong-Young;Kim, Sung-Chul;Lee, Jong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.2
    • /
    • pp.29-34
    • /
    • 2010
  • This paper is aimed to develop monitoring software for detecting the characteristics of current and voltage signals for series arc on electric wire. In order to attain this purpose, the characteristics of series arc were analyzed by the current and voltage signals on electric wire which were installed, and also analyzed by the changes of RMS, instantaneous of waveform value in time domain and THD in frequency domain. Monitoring program which analyze the signal was developed by Labview which can analyze in time domain and frequency domain, and save data. Experimental setup for detecting verification of monitoring program was composed loads of a lamp, an electric heater and an electric fan loads which were usually using. Measurement points for detecting verification of monitoring program were selected at both the panel board and the arc generator at the same time. As results of the experiments by monitoring program, the arc current waveform showed the same characteristic in all measurement points of all load. But the arc voltage waveform was different in each measurement point. When arc occurred, the THD of current value increased above 20%. The results of this study will be effectively used in developing the preventive system of electric fire by series arc.