• Title/Summary/Keyword: False-negative results

Search Result 302, Processing Time 0.029 seconds

Clinical Characteristics of False-Positive Lymph Node on Chest CT or PET-CT Confirmed by Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration in Lung Cancer

  • Lee, Jongmin;Kim, Young Kyoon;Seo, Ye Young;Choi, Eun Kyoung;Lee, Dong Soo;Kim, Yeon Sil;Hong, Sook Hee;Kang, Jin Hyoung;Lee, Kyo Young;Park, Jae Kil;Sung, Sook Whan;Kim, Hyun Bin;Park, Mi Sun;Yim, Hyeon Woo;Kim, Seung Joon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.81 no.4
    • /
    • pp.339-346
    • /
    • 2018
  • Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a standard procedure to evaluate suspicious lymph node involvement of lung cancer because computed tomography (CT) and $^{18}F$-fluorodeoxyglucose positron emission tomography-CT (PET-CT) have limitations in their sensitivity and specificity. There are a number of benign causes of false positive lymph node such as anthracosis or anthracofibrosis, pneumoconiosis, old or active tuberculosis, interstitial lung disease, and other infectious conditions including pneumonia. The purpose of this study was to evaluate possible causes of false positive lymph node detected in chest CT or PET-CT. Methods: Two hundred forty-seven patients who were initially diagnosed with lung cancer between May 2009 and December 2012, and underwent EBUS-TBNA to confirm suspicious lymph node involvement by chest CT or PET-CT were analyzed for the study. Results: Of 247 cases, EBUS-TBNA confirmed malignancy in at least one lymph node in 189. The remaining 58 patients whose EBUS-TBNA results were negative were analyzed. Age ${\geq}65$, squamous cell carcinoma as the histologic type, and pneumoconiosis were related with false-positive lymph node involvement on imaging studies such as chest CT and PET-CT. Conclusion: These findings suggest that lung cancer staging should be done more carefully when a patient has clinically benign lymph node characteristics including older age, squamous cell carcinoma, and benign lung conditions.

Breast Magnetic Resonance Imaging Indications in Current Practice

  • Taif, Sawsan Abdulkareem
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.2
    • /
    • pp.569-575
    • /
    • 2014
  • Although mammography is the primary imaging modality for the breast, it has its limitations especially with dense breast parenchyma. Breast magnetic resonance imaging (MRI) has evolved into an important adjunctive tool as it is currently the most sensitive technique for breast cancer detection. Despite this high sensitivity, overlap in the appearances of some benign and malignant breast lesions results in additional unnecessary intervention with negative results. These false positives, in addition to high cost and limited availability, necessitate establishing proper indications for breast MRI. The literature was here reviewed for recent clinical trials, meta-analyses and review papers which have studied this important subject. PubMed; the US national library of medicine, was utilized to review the literature in the last twenty years. Using the obtained information, current uses of breast MRI are discussed in this paper to determine the indications which are relevant to clinical practice.

Internal Amplification Control for a Cryptosporidium Diagnostic PCR: Construction and Clinical Evaluation

  • Hawash, Yousry;Ghonaim, M.M.;Al-Hazmi, Ayman S.
    • Parasites, Hosts and Diseases
    • /
    • v.53 no.2
    • /
    • pp.147-154
    • /
    • 2015
  • Various constituents in clinical specimens, particularly feces, can inhibit the PCR assay and lead to false-negative results. To ensure that negative results of a diagnostic PCR assay are true, it should be properly monitored by an inhibition control. In this study, a cloning vector harboring a modified target DNA sequence (${\approx}375bp$) was constructed to be used as a competitive internal amplification control (IAC) for a conventional PCR assay that detects ${\approx}550bp$ of the Cryptosporidium oocyst wall protein (COWP) gene sequence in human feces. Modification of the native PCR target was carried out using a new approach comprising inverse PCR and restriction digestion techniques. IAC was included in the assay, with the estimated optimum concentration of 1 fg per reaction, as duplex PCR. When applied on fecal samples spiked with variable oocysts counts, ${\approx}2$ oocysts were theoretically enough for detection. When applied on 25 Cryptosporidium-positive fecal samples of various infection intensities, both targets were clearly detected with minimal competition noticed in 2-3 samples. Importantly, both the analytical and the diagnostic sensitivities of the PCR assay were not altered with integration of IAC into the reactions. When tried on 180 randomly collected fecal samples, 159 were Cryptosporidium-negatives. Although the native target DNA was absent, the IAC amplicon was obviously detected on gel of all the Cryptosporidium-negative samples. These results imply that running of the diagnostic PCR, inspired with the previously developed DNA extraction protocol and the constructed IAC, represents a useful tool for Cryptosporidium detection in human feces.

Agreement between Colposcopic Diagnosis and Cervical Pathology: Siriraj Hospital Experience

  • Tatiyachonwiphut, Molpen;Jaishuen, Atthapon;Sangkarat, Suthi;Laiwejpithaya, Somsak;Wongtiraporn, Weerasak;Inthasorn, Perapong;Viriyapak, Boonlert;Warnnissorn, Malee
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.1
    • /
    • pp.423-426
    • /
    • 2014
  • Aim: To evaluate the agreement between colposcopic diagnosis and cervical pathology a retrospective chart review was performed. Materials and Methods: This study included 437 patients who underwent colposcopy and cervical biopsy or conization at Siriraj Hospital from October 2010 - December 2012. The patient clinical characteristics, cervical cytology results, colposcopic diagnoses, cervical pathology results were recorded and correlations between variables were analyzed. Results: Agreement of colposcopic diagnosis and cervical pathology was matched in 253 patients (57.9%). The strength of agreement with weighted Kappa statistic was 0.494 (p<0.001). Colposcopic diagnoses more often overestimated (31.1%) than underestimated (11%) the cervical pathology. Agreement of colposcopic diagnosis and cervical pathology within 1 grade was found in 411 patients (94.1%). Positive predictive value (PPV) of high grade colposcopy or more was 75.5%, whereas the negative predictive value (NPV) of insignificant and low grade colposcopy was 83.8%. False positives of high grade colposcopy or more were 21%. False negatives of insignificant or low grade colposcopy were 19.1%. Conclusions: Strength of agreement between colposcopic diagnosis and cervical pathology was found to be only moderate. A biopsy at colposcopy should be performed at a gold standard level to detect high grade lesions.

Nonspecific Mouse Hepatitis Virus Positivity of Genetically Engineered Mice Determined by ELISA

  • Han, Dae Jong;Kim, Hyuncheol;Yeom, Su-Cheong
    • Biomedical Science Letters
    • /
    • v.21 no.1
    • /
    • pp.9-14
    • /
    • 2015
  • Mouse hepatitis virus (MHV) is a major pathogen in laboratory mice that usually leads to fatal diseases, such as hepatitis, multiple sclerosis, encephalitis, and respiratory disease. MHV has a high infection rate, and it needs to be detected as soon as possible to prevent its spread to other facilities. However, MHV detection by enzyme-linked immunosorbent assay (ELISA) often gives false positives; thus, it is very important that the results are confirmed as true positives in the early infection stage or distinguished as false positives with more accurate, reliable methods. Under microbiological screening, MHV ELISA-positive mice were found in four GFP-tagging transgenic mice. To verify the detection of the MHV antigen directly, reverse transcription polymerase chain reaction (RT-PCR) was performed, and the mice were determined to be MHV negative. Additional serum antibody-based screening was conducted with three different ELISA kits, and multiplexed fluorometric immunoassay (MFIA) was performed to confirm their accuracy/sensitivity. In brief, the ELISA kit for A59 nucleocapsid protein (MHV-A59N) revealed MHV ELISA positivity, while other ELISA kits (MHV-S lysate and MHV-JHM lysate) demonstrated MHV negativity. In MFIA, only the test for the recombinant A59 nucleocapsid antigen was MHV positive, which was consistent with the ELISA results. These results suggest that the ELISA kit with the recombinant A59 nucleocapsid antigen might induce non-specific MHV ELISA positivity and that confirmation is therefore essential.

A Study on Availability about Positron Emission Mammography of Breast Cancer (유방암 환자의 Positron Emission Mammography에서의 유용성에 관한 연구)

  • Kim, Seung-Jeong;Kim, Jae-Il;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.60-64
    • /
    • 2010
  • Purpose: Until now the general study for breast cancer patient has been mammography, breast sonography for anatomic diagnostics and $^{18}F$-FDG whole body PET for functional one. But the PEM (Positron Emission Mammography) was developed to increase sensitivity, specificity and accuracy to improve the disadvantage of each study. Therefore this present study aims to describe availability of PEM for improving diagnosis of breast cancer. Materials and Methods: During 3 months from January in 2010, PEM was performed on 100 patients who had history of breast cancer. Using Naviscan's PEM Flex Solo II scanner, PEM images of breast were acquired. And then we evaluated sensitivity, specificity and accuracy of PEM data by comparing results of PEM images with postoperative pathologic finding. Results: On the 100 patients, it could reveal 89 true positive, 9 false positive, 7 false negative and 87 true negative. Thus the results of sensitivity, specificity and accuracy for PEM was evaluated 92.7%, 90.6% and 91.7%. Conclusion: The sensitivity, specificity and accuracy have been reported 83.7%, 68.5% and 77.1% in mammography, and that was 89.1%, 79.1% and 83.4% in breast sonography. However the results of PEM were more increased than others. Therefore the results of this study will be available that PEM used diagnosis with breast cancer, used preoperative operation plan and helps to discovery of a part recurrence.

  • PDF

Contents Analysis of Media on Long-term Care Insurance (노인장기요양보험 관련 미디어 내용 분석)

  • Chin, Young-Ran;Lee, Hyo-Young
    • The Korean Journal of Health Service Management
    • /
    • v.10 no.2
    • /
    • pp.155-166
    • /
    • 2016
  • Objectives : This study confirmed the limitation of long-term care insurance by analyzing media contents. Methods : Articles and reviews were searched with the article searching system (KINDS) from July 2008 to December, 2015. Results : Among the 155 articles examined, 61.1% highlighted the faults of suppliers, and 25.2% indicated the responsibility of the insurer. As for their purpose, 56.8% reported on accidents, and 32.3% provided information. Furthermore, 74.2% reported on negative contents and only 25.8% on neutral contents. The negative contents consisted of requesting false insurance benefits, amending the range and price indicating the very low salaries of the care givers, limitations on the care grade assessment, and problems related with assistive devices. The majority of neutral articles is for providing information. Conclusions : There were many problems starting from the early stage of the insurance. We must pay attention to these problems. Moreover, we should try to handle and prevent these problems with supportive responses from authorities.

Imbalanced SVM-Based Anomaly Detection Algorithm for Imbalanced Training Datasets

  • Wang, GuiPing;Yang, JianXi;Li, Ren
    • ETRI Journal
    • /
    • v.39 no.5
    • /
    • pp.621-631
    • /
    • 2017
  • Abnormal samples are usually difficult to obtain in production systems, resulting in imbalanced training sample sets. Namely, the number of positive samples is far less than the number of negative samples. Traditional Support Vector Machine (SVM)-based anomaly detection algorithms perform poorly for highly imbalanced datasets: the learned classification hyperplane skews toward the positive samples, resulting in a high false-negative rate. This article proposes a new imbalanced SVM (termed ImSVM)-based anomaly detection algorithm, which assigns a different weight for each positive support vector in the decision function. ImSVM adjusts the learned classification hyperplane to make the decision function achieve a maximum GMean measure value on the dataset. The above problem is converted into an unconstrained optimization problem to search the optimal weight vector. Experiments are carried out on both Cloud datasets and Knowledge Discovery and Data Mining datasets to evaluate ImSVM. Highly imbalanced training sample sets are constructed. The experimental results show that ImSVM outperforms over-sampling techniques and several existing imbalanced SVM-based techniques.

Direction of Global Citizenship Education in the Age of Infodemic : A Case Study of the COVID-19 Pandemic in Korea

  • Jisu Park
    • International journal of advanced smart convergence
    • /
    • v.12 no.1
    • /
    • pp.82-91
    • /
    • 2023
  • In 2020 when the COVID-19 pandemic began in full-scale, the WHO Director-General warned of the dangers of an infodemic. The infodemic is a phenomenon in which false information spreads rapidly like an epidemic and causes chaos, and it was noted that the COVID-19 pandemic is not just limited to health problems, but also linked to a variety of issues such as human rights, economic inequality, various discrimination, hate speech, fake news, global governance etc. In the field of education, it is necessary to think about how to connect this global situation with school classes. Accordingly, this study suggested the direction for global citizenship education by analyzing how the infodemic spreads on Korean social media with the case of the recent global COVID-19 pandemic. According to the research results, the rate of negative emotions was higher than positive ones in the emotions that generate infodemic, while anxiety and anger were focused among negative emotions. In addition, the infodemic tended to spread widely with the feelings of anger rather than anxiety, and the feelings of anger led to advocating aggressive policies against certain country and regions. Therefore, global citizenship education is required to focus on a sense of duty and responsibility as a citizen, not on the level of national identity based on an exclusive sense of belonging. Furthermore, global citizenship education needs to lead to presenting a blueprint for education in a way that can enhance the awareness of the global community for joint response to global challenges and realize common prosperity based on sustainability and justice.

Improvement of non-negative matrix factorization-based reverberation suppression for bistatic active sonar (양상태 능동 소나를 위한 비음수 행렬 분해 기반의 잔향 제거 기법의 성능 개선)

  • Lee, Seokjin;Lee, Yongon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.4
    • /
    • pp.468-479
    • /
    • 2022
  • To detect targets with active sonar system in the underwater environments, the targets are localized by receiving the echoes of the transmitted sounds reflected from the targets. In this case, reverberation from the scatterers is also generated, which prevents detection of the target echo. To detect the target effectively, reverberation suppression techniques such as pre-whitening based on autoregressive model and principal component inversion have been studied, and recently a Non-negative Matrix Factorization (NMF)-based technique has been also devised. The NMF-based reverberation suppression technique shows improved performance compared to the conventional methods, but the geometry of the transducer and receiver and attenuation by distance have not been considered. In this paper, the performance is improved through preprocessing such as the directionality of the receiver, Doppler related thereto, and attenuation for distance, in the case of using a continuous wave with a bistatic sonar. In order to evaluate the performance of the proposed system, simulation with a reverberation model was performed. The results show that the detection probability performance improved by 10 % to 40 % at a low false alarm probability of 1 % relative to the conventional non-negative matrix factorization.