• 제목/요약/키워드: False detection

Search Result 1,195, Processing Time 0.031 seconds

Development of Rapid Analysis Method for Pesticide Residues by GC-MS/MS (GC-MS/MS를 이용한 잔류농약 신속검사법 개발)

  • Choi, Yong-Hoon;Nam, Hye-Seon;Hong, Hye-Mi;Lee, Jin-Ha;Chae, Kab-Ryong;Lee, Jong-Ok;Kim, Hee-Yun;Yoon, Sang-Hyeon
    • The Korean Journal of Pesticide Science
    • /
    • v.9 no.4
    • /
    • pp.292-302
    • /
    • 2005
  • Condition of Ion-Trap gas chromatography-mass spectrometry (GC-MS) for rapid screening of 206-pesticides residues in agricultural foodstuffs was optimized. As applying a wide-bore column (10 m${\times}$0.53 mm, DF 0.25 um) connected with a fused silica restrictor (0.6 m${\times}$0.1 mm), a significant retention time reduction was obtained. Additionally, the shape of peaks was sharper and higher than classical GC's and GC-MS's, which allowed lower detection limits. To easily manage many spectral data, both of Electron Ionization(EI) and Chemical Ionization(CI) techniques were adopted in screening procedure. At the following steps, MS-MS technique were used to confirm screened analytes in complicated matrices.

Abstraction Mechanism of Low-Level Video Features for Automatic Retrieval of Explosion Scenes (폭발장면 자동 검출을 위한 저급 수준 비디오 특징의 추상화)

  • Lee, Sang-Hyeok;Nang, Jong-Ho
    • Journal of KIISE:Software and Applications
    • /
    • v.28 no.5
    • /
    • pp.389-401
    • /
    • 2001
  • This paper proposes an abstraction mechanism of the low-level digital video features for the automatic retrievals of the explosion scenes from the digital video library. In the proposed abstraction mechanism, the regional dominant colors of the key frame and the motion energy of the shot are defined as the primary abstractions of the shot for the explosion scene retrievals. It is because an explosion shot usually consists of the frames with a yellow-tone pixel and the objects in the shot are moved rapidly. The regional dominant colors of shot are selected by dividing its key frame image into several regions and extracting their regional dominant colors, and the motion energy of the shot is defined as the edge image differences between key frame and its neighboring frame. The edge image of the key frame makes the retrieval of the explosion scene more precisely, because the flames usually veils all other objects in the shot so that the edge image of the key frame comes to be simple enough in the explosion shot. The proposed automatic retrieval algorithm declares an explosion scene if it has a shot with a yellow regional dominant color and its motion energy is several times higher than the average motion energy of the shots in that scene. The edge image of the key frame is also used to filter out the false detection. Upon the extensive exporimental results, we could argue that the recall and precision of the proposed abstraction and detecting algorithm are about 0.8, and also found that they are not sensitive to the thresholds. This abstraction mechanism could be used to summarize the long action videos, and extract a high level semantic information from digital video archive.

  • PDF

A Study on Response Characteristics of Photoelectric Type Smoke Detector Chamber Due to Dust Color (분진색상에 따른 광전식연기감지기 챔버의 응답특성에 관한 연구)

  • Lee, Ho-Sung;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.44-52
    • /
    • 2017
  • This paper is based on a study of the response characteristics of photoelectric type smoke detector chambers according to dust color. Due to an amendment to the Fire Safety Codes to automatic fire alarm systems and visual alarm device, the installation of indoor smoke detectors has become mandatory, but in Korea there is still insufficient research on the non-operation or false alarms that could arise in indoor environments by indoor dust and other environmental conditions etc. In light of this, for this study, research was conducted on the indoor adaptability of smoke detector under various colors of fiber dust that were judged to occur most frequently in among the common indoor dust, photoelectric smoke detector with the lattice-type smoke detection chamber that the smoke detector which is most popular in the country was used, and four colors of fiber dust (brown, white, gray and black) were used the test dusts for carrying out dust and sensitivity testing. Also, the voltage of the photocell part of the smoke chamber was measured, and the scattering phenomenon in the chamber was observed. The result of the testing showed that all four dust types were suitable for dust and sensitivity testing under conditions of pollution A. Yet, there were occasions, at pollution B or C, where the brown, white and gray dust would cause fail alarm during operation testing. And black dust was confirmed to cause non-operation during operation testing. In the case of brown and white dust, the voltage measurement result of the photocell part of the smoke chamber confirmed that the voltage increases as the pollution level increases, and in the case of gray and black dust, the voltage decreases.

Development of SCAR markers in Creeping bentgrass(Agrostis palustrics Huds.) cultivars (Creeping bentgrass(Agrostis palustrics Huds.) 품종별 SCAR markers 개발)

  • Jang, Duk-Hwan;Jung, Seung-Ho
    • Asian Journal of Turfgrass Science
    • /
    • v.23 no.2
    • /
    • pp.307-316
    • /
    • 2009
  • Creeping bentgrass (Agrostis palustrics Huds.) is cool season turfgrasse that is used for putting green in golf course. Creeping bentgrass cultivars are difficult to distinguish with the same species because of similar morphological characters and low level of genetic diversity. The SCAR markers using the specific DNA can be useful for differentiating between creeping bentgrass cultivars. Five RAPD primers were used for specific band detection among creeping bentgrass cultivars, penncross, penn A-4, crenshaw, L-93, CY-2, T-1. The pairs of SCAR primers for six cultivers were designed by the specific sequences of the bands that amplified by RAPD. Three of the six SCAR primers could not make the use as SCAR primers because the specific false bands were detected in all cultivars. The remaining pairs of SCAR primer, CY850F/R, T700F/R, L2900F/R, amplified the specific band at expected size for three cultivars, CY-2, T-1, L-93, respectively. The CY850F/R primer amplified a band of 850bp in CY-2 cultivar, the T700F/R primer amplified a band of 700bp in T-1 cultivar, and the L2900F/R primer amplified a band of 2.9kb in L-93 cultivar. In this study we developed the SCAR markers to identify and distinguish the inerseeded creeping bentgrass cultivars in a golf course green.

An Assessment of Applicability of Heat Waves Using Extreme Forecast Index in KMA Climate Prediction System (GloSea5) (기상청 현업 기후예측시스템(GloSea5)에서의 극한예측지수를 이용한 여름철 폭염 예측 성능 평가)

  • Heo, Sol-Ip;Hyun, Yu-Kyung;Ryu, Young;Kang, Hyun-Suk;Lim, Yoon-Jin;Kim, Yoonjae
    • Atmosphere
    • /
    • v.29 no.3
    • /
    • pp.257-267
    • /
    • 2019
  • This study is to assess the applicability of the Extreme Forecast Index (EFI) algorithm of the ECMWF seasonal forecast system to the Global Seasonal Forecasting System version 5 (GloSea5), operational seasonal forecast system of the Korea Meteorological Administration (KMA). The EFI is based on the difference between Cumulative Distribution Function (CDF) curves of the model's climate data and the current ensemble forecast distribution, which is essential to diagnose the predictability in the extreme cases. To investigate its applicability, the experiment was conducted during the heat-wave cases (the year of 1994 and 2003) and compared GloSea5 hindcast data based EFI with anomaly data of ERA-Interim. The data also used to determine quantitative estimates of Probability Of Detection (POD), False Alarm Ratio (FAR), and spatial pattern correlation. The results showed that the area of ERA-Interim indicating above 4-degree temperature corresponded to the area of EFI 0.8 and above. POD showed high ratio (0.7 and 0.9, respectively), when ERA-Interim anomaly data were the highest (on Jul. 11, 1994 (> $5^{\circ}C$) and Aug. 8, 2003 (> $7^{\circ}C$), respectively). The spatial pattern showed a high correlation in the range of 0.5~0.9. However, the correlation decreased as the lead time increased. Furthermore, the case of Korea heat wave in 2018 was conducted using GloSea5 forecast data to validate EFI showed successful prediction for two to three weeks lead time. As a result, the EFI forecasts can be used to predict the probability that an extreme weather event of interest might occur. Overall, we expected these results to be available for extreme weather forecasting.

Analysis on Normal Ionospheric Trend and Detection of Ionospheric Disturbance by Earthquake (정상상황 전리층 경향 분석 및 지진에 의한 전리층 교란검출)

  • Kang, Seonho;Song, Junesol;Kim, O-jong;Kee, Changdon
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.2
    • /
    • pp.49-56
    • /
    • 2018
  • As the energy generated by earthquake, tsunami, etc. propagates through the air and disturbs the electron density in the ionosphere, the perturbation can be detected by analyzing the ionospheric delay in satellite signal. The electron density in the ionosphere is affected by various factors such as solar activity, latitude, season, and local time. To distinguish from the anomaly, therefore, it is required to inspect the normal trend of the ionosphere. Also, as the perturbation magnitude diminishes by distance it is necessary to develop an appropriate algorithm to detect long-distance disturbances. In this paper, normal condition ionosphere trend is analyzed via IONEX data. We selected monitoring value that has no tendency and developed an algorithm to effectively detect the long-distance ionospheric disturbances by using the lasting characteristics of the disturbances. In the end, we concluded the $2^{nd}$ derivative of ionospheric delay would be proper monitoring value, and the false alarm with the developed algorithm turned out to be 1.4e-6 level. It was applied to 2011 Tohoku earthquake case and the ionospheric disturbance was successfully detected.

Analysis of the Optimal Window Size of Hampel Filter for Calibration of Real-time Water Level in Agricultural Reservoirs (농업용저수지의 실시간 수위 보정을 위한 Hampel Filter의 최적 Window Size 분석)

  • Joo, Dong-Hyuk;Na, Ra;Kim, Ha-Young;Choi, Gyu-Hoon;Kwon, Jae-Hwan;Yoo, Seung-Hwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.64 no.3
    • /
    • pp.9-24
    • /
    • 2022
  • Currently, a vast amount of hydrologic data is accumulated in real-time through automatic water level measuring instruments in agricultural reservoirs. At the same time, false and missing data points are also increasing. The applicability and reliability of quality control of hydrological data must be secured for efficient agricultural water management through calculation of water supply and disaster management. Considering the characteristics of irregularities in hydrological data caused by irrigation water usage and rainfall pattern, the Korea Rural Community Corporation is currently applying the Hampel filter as a water level data quality management method. This method uses window size as a key parameter, and if window size is large, distortion of data may occur and if window size is small, many outliers are not removed which reduces the reliability of the corrected data. Thus, selection of the optimal window size for individual reservoir is required. To ensure reliability, we compared and analyzed the RMSE (Root Mean Square Error) and NSE (Nash-Sutcliffe model efficiency coefficient) of the corrected data and the daily water level of the RIMS (Rural Infrastructure Management System) data, and the automatic outlier detection standards used by the Ministry of Environment. To select the optimal window size, we used the classification performance evaluation index of the error matrix and the rainfall data of the irrigation period, showing the optimal values at 3 h. The efficient reservoir automatic calibration technique can reduce manpower and time required for manual calibration, and is expected to improve the reliability of water level data and the value of water resources.

Sexual Behaviors, Estrus Detection and Conception of Heifers Synchronized by Progesterone Intravaginal Device(Prid) and Synchromate-B

  • Im, K.S.;Kim, C.K.;Voss, H.J.;Allen, S.;Zheng, X.;Foote, R.H.
    • Korean Journal of Animal Reproduction
    • /
    • v.9 no.2
    • /
    • pp.140-147
    • /
    • 1985
  • Seventy four Holstein heifers were randomly assigned over three trials to PRID-7+PG-6 and Synchromate B-9 regimens to synchronize estrus cycle for embryo transfer. Sexual behaviors; moounting, standing, orientation, chin-resting, sniffing, licking, rubbing and butting, vaginal swelling and mucus discharge were observed between 06-08, 12-14 and 18-20 h on 1st day and 00-02, 06-08, 12-14 and 18-20 h on 2nd day after removal of hormones. Synchromate-B treatment (81.6%) showed higher synchronized estrus rate than PRID treatment (77.8%) during observation period. Standing estrus was observed within 74 h after PG injection in PRID and within 52 h after removal of implant in Synchromate-B. About 68% of heifers in PRID and 74% of heifers in Synchromate-B showed standing estrus between 0-14 h on 2nd day after removal of the hormones. Synchromate-B resulted in a tighter synchrony of standing estrus than PRID. Incidence of average mounting and standing per head during observation period was 22.3 and 16.6 in PRID and 28.1 and 13.6 in Synchromate-B. The PRID showed peak in active mounting at 18-20 h on 1st day, however, the Synchromate-B showed at 0-2 h on 2nd day after removal of hormone. Active standing was shown between 18 h on 1st day to 20h on 2nd day in PRID, however, between 0-14 h on 2nd day after removal of hormone is Synchromate-B. There was slight difference in pattern of active mounting and standing during estrus between PRID and Synchromate-B. Conception rate of synchronized heifers transferred with fresh and frozen embryos by non-surgical and surgical methods was higher in synchromate-B (62.5%) than in PRID (38.5%). Chin-resting showed highest incidence among 6 sexual behavioral components in the both treatments. Synchromate-B showed higher incidence of chin-resting (16.6) than PRID (10.7). Synchromate-B group showed also higher incidence of orientation, sniffing and butting than PRID group. Synchromate-B resulted in more active sexual behaviors than PRID. The pattern of incidence of chin-resting, licking and butting was almost symmetrical in PRID with their peak values at 6-8 h on 2nd day, however in Synchromate-B chin-resting and sniffing was symmetrical with their peak values at 12-14 h on 2nd day after removal of hormone. There was tendency to increase vaginal swelling according to time passage of synchronized estrus in the both treatments. Incidence of mucus discharge in Synchromate-B was slightly higher than in PRID. Twenty to 40% was false negative in conception rate by tall painting before re-estrus day as judged by rectal palpation.

  • PDF

Convergence research on cytological diagnosis of gynecological diseases and genital HPV : Based on data from the Obstetrics and Gynecology Department of a general hospital located in Suwon-si (수원시 소재 일개 종합병원 산부인과에서 자궁경부 질환 검사의 실태조사 : HPV와 세포학적 검사의 융합연구)

  • Joung, You Hyun;Lee, Jun Min;Kim, Jong-Wan;Kim, Jae Kyung
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.1
    • /
    • pp.119-129
    • /
    • 2022
  • Cervical cytology has been widely used as a screening tool for cervical cancer. However, Human papillomavirus (HPV) detection and subtype testing are suggested to overcome the high false-negative rate associated with cytology. We aimed to investigate the clinical usefulness and infection rate in the HPV polymerase chain reaction (PCR) test performed in hospitals. HPV PCR data from 217 patients were analyzed. Analysis of variance revealed a significant difference in the infection rate among different age groups (P=0.015). The biopsy results showed that epithelial cell abnormalities and high HPV-positivity rate was observed in 1 (100%) subject aged <29 years, in 4 out of 5 (80%) patients in their 30s, and in 3 out of 4 (75%) patients aged ≥70 years. The prevalence of HPV infection was very high (46.1%). The highest prevalence (87.5%) was observed among patients in their <29, followed by those in their 30s (67.7%) and those in their 40s (31.9%).A high rate of epithelial cell abnormalities (≥ cervical intraepithelial neoplasia type 1, mild dysplasia) was observed in HPV-infected women aged<30 years. Therefore, extensive research and prevention activities are needed in this age group. HPV PCR testing is recommended to complement cervical cytology

Triple Detector SPECT Imaging with $^{99m}Tc-DMSA$ in Adult Patients with Urinary Tract Infection (성인 요로 감염 환자에서 $^{99m}Tc-DMSA$ 삼중검출기 SPECT 영상의 유용성)

  • Ryu Jin-Sook;Bae, Won-Gyu;Moon Dae-Hyuk;Lee, Myung-Hae;Kim, Soon-Bae,;Park, Su-Kil;Park, Jung-Sik;Hong, Chang-Gi D.;Cho, Kyung-Sik
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.290-298
    • /
    • 1992
  • Although early diagnosis of urinary tract infection is important, the radiologic evaluation is still controversial because of the low sensitivity and the lack of cost-effectiveness. This study was carried out to evaluate the clinical utility of high resolution triple head $^{99m}Tc-DMSA$ SPECT imaging in urinary tract infection. We prospectively performed $^{99m}Tc-DMSA$ planar and SPECT imaging, ultrasound of kidney (US), intravenous pyelography (IVP) and voiding cystourethrography (VCU) in all 60 adult patients with UTI [26 with first episode of acute pyelonephritis (APN), 22 with recurrent APN, and 12 persistent asymptomatic pyuria] and 25 normal persons. To assess reversibility of the renal cortical defect (RCD), $^{99m}Tc-DMSA$ SPECT was repeated 1 to 8 months later in those patients with abnormal initial findings. Overall detection rate of $^{99m}Tc-DMSA$ SPECT imaging was 83% (50/60), but planar, US, IVP and VCU showed abnormal findings in 68%, 28%, 32% and 13%, respectively. 25 out of 27 patients with normal or single RCD were all normal in other radioligic studies. Only two patients showed vesicoureteral reflux (VUR) on VCU (grade I) and mild hydronephrosis on IVP. But, high proportion of those with multiple RCD showed abnormal findings on US (17/33), IVP (18/33), and VCU (7/33): 67% in any of these 3 studies. Especially, 3 out 7 patients with VUR showed multiple RCD on $^{99m}Tc-DMSA$ SPECT without any abnormality on IVP or US. 25 normal persons showed normal findings in all studies except one false positive finding on $^{99m}Tc-DMSA$ SPECT imaging. Follow-up $^{99m}Tc-DMSA$ SPECT was done in 28 patients (13 with single RCD, 15 with multiple RCD). All 13 patients with single RCD showed improvement. Those with multiple RCD presented improvement in 4, no change in 10, and aggravation in 1 on follow-up studies. With these results, we conclude: 1) $^{99m}Tc-DMSA$ SPECT imaging is superior to planar imaging, US, IVP or VCU in detection of renal lesion in urinary tract infection. $^{99m}Tc-DMSA$ SPECT is useful as a initial diagnostic tool in adult patients with urinary tract infection. 2) The multiple RCD on $^{99m}Tc-DMSA$ SPECT represent the high probability of irreversible tissue change and need of extensive urological work-up.

  • PDF